JASC 3320

Service difficulty reports · 2,972

Reports filed under 3320 · Passenger Compartment Lighting, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA13041389232Ballast · failedAFT F/A WITNESSED SMOKE AND ELECTRICAL ODOR FROM OVERHEAD LAST ROW OF SEATS. MX FOUND CEILING LIGHT BALLAST FORWARD END AT 37CDE BURNED/SHORTED TO MOUNT SCREW. R & R BALLAST IAW MM. OPS CHECKED NORMAL.Aug 26, 2013 · N932DN · Doug MD9030SDR HNAA2013082600475Unknown · odorELECTRICAL BURNING ODOR APPEARS TO BE COMING FROM OVERHEAD LIGHTS AT ROW 7DF. R & R LAMP HOLDER, BULB AND BALLAST. OPS CHECKED GOOD.Aug 26, 2013 · N815EX · Dhav DHC8102SDR SWIA201334403Cover · missingRED COVER MISSING ON FORWARD FACING MID CABIN FLIGHT ATTENDANT CALL LIGHT. FLT#5505 REPLACED RED COVER ON FORWARD FACING MID CABIN FLIGHT ATTENDANT CALL LIGHT.Aug 25, 2013 · N652BR · Cndair CL6002B19SDR CHQA20130823325Ballast · inoperativeDURING TAXI, CREW REPORTED A BURNING ODOR AND VISIBLE SMOKE IN THE CABIN COMING FROM THE CABIN LIGHTING BALLAST AT ROW 1. RETURNED TO GATE, REPLACED BALLAST. NO FURTHER DEFECTS HAVE BEEN NOTED.Aug 23, 2013 · N271SK · Emb EMB145LRSDR HNAA2013082200471Socket · overheatedHOT ELECTRICAL ODOR OVER ROW 4. INSPECTED AND FOUND OVERHEAD LIGHT 3DF OVERHEATING AT SOCKET AND BASE. REMOVED BULB, PULLED AND COLLARED CIRCUIT BREAKERS S1, S2 AND R2. CABIN INTERIOR NORMAL LIGHTING SYS, R & R SOCKET AT LAMP ASSY ON ROW 3DF. OPS CHECKED GAug 19, 2013 · N839EX · Dhav DHC8102SDR HNAA2013081900470Socket · failedOVERHEAD LIGHT AT ROW 8 IS INOPERATIVE. REMOVED PANEL, FOUND MELTED SOCKET, R & R SOCKET AND BALLAST. REINSTALLED PANEL. OPS CHECKED GOOD IAW CMM 33-21-19.Aug 19, 2013 · N935HA · Dhav DHC8102SDR CALA2013090490985Light · inoperativeLT COVER AT GALLEY LT 609 AT ECONOMY GALLEY 431 BURNT. REPLACED LENS 560-3997 & RELAMPED IAW MM, OPERATIONS CHECKED OK.Aug 16, 2013 · N120UA · Boeing 747422SDR CALA2013081990514Control Panel · shortedCABIN LIGHTS KEEP GOING OUT, CONTROL PANEL BY L1 DOOR SEEMS TO HAVE SHORT. REPLACED PANEL WITH PANEL FROM 5413.Aug 16, 2013 · N524UA · Boeing 757222SDR CA130815008Socket · burned(CAN) DEFECT-1128460, OVERHEAD CEILING LIGHT ASSY SHOWING SIGNS OF ARCING AT 5DF. RESOLVED ON W/O: 396234 TASKCARD, NR-00009. OVERHEAD BIN AT 5DF LOWERED FOR ACCESS, AND RE-INSTALLED. LAMP HOLDER ASSY REPLACED AT 5DF AND LAMP REPLACED. OVERHEAD LIGHTS AT 5DAug 15, 2013 · Dhav DHC8311SDR DXTA2013081505476Switch · failedAFTER LANDING, CABIN INTERIOR LIGHTS WERE TURNED ON. WHEN THE AIRSTAIR DOOR WAS OPENED AND LOCKED IN THE FULL DOWN POSITION ALL THE ENTRY AND CABIN INTERIOR LIGHTS WENT OUT. TROUBLESHOT TO FAULTY GALLEY SWITCH PANEL. R & R SWITCH ASSY IAW MM. SYS OPS CHEAug 15, 2013 · N679QS · Cessna 560XLSDR CALA2013081400566Socket · wornONE OF THE SOCKETS FOR FLUORESCENT MIRROR LIGHT BURNED OUT IN LAV "L", CAUSING ELECTRICAL SMOKE. SOCKET NEEDS TO BE REPLACED. DOME LIGHT WORKS OK. LAV USEABLE. TOMC UPDATE: CHANGED ITEM 33-21-1 TO NEW HARMONIZED ITEM ITEM DEFERRED IAW MEL 33-21-1, CN 651188Aug 14, 2013 · N37018 · Boeing 777224SDR IPXA13179807Lamp · inoperativeLAV MIRROR LIGHT INOPERATIVE IN DIM. REPLACED LAMPS IAW AMM 33-51-21-401.Aug 13, 2013 · N168UP · Airbus A300F4622RSDR A6WA2013081200001Light · odorLEFT 14TH DUCT FAILS DUCT TEST. ANIT-ICE PAGE SHOWS DARK-DUCT FROM LEFT VALVE TO LEFT COWL. TEST CAUSES STRONG BURNING ODOR. TROUBLESHOT AND FOUND CONNECTOR P83WK WIRE DISCONNECTED, R&R'D CONNECTOR P83WK PER ESPM 20-17-11 AND PERFORMED OPS CK PER AMM 36-21-00Aug 10, 2013 · N408AW · Cndair CL6002B19SDR CALA2013080990299Cover · burnedAFT GALLEY LIGHT COVER BURNED. FLT DIVERTED.Aug 9, 2013 · N120UA · Boeing 747422SDR CALA2013080700546Socket · burnedF/A REPORTED ODOR OF ELECTRICAL SMOKE FROM LAVATORY "L", AFTER INVESTIGATION, IT WAS REPORTED THAT BALLAST FOR FLUORESCENT LIGHT WAS HOT TO TOUCH. AFTER CONSULTING WITH MX, DISCONNECTED BULBS. EVIDENCE OF SCORCHING AT BASE OF ONE BULB. BALLAST COOLED IMMEDAug 6, 2013 · N37018 · Boeing 777224SDR SWIA201334157Ballast · failedSTRONG ODOR OF HOT PLASTIC IN FRONT SECTION OF CABIN. FLT#6499 REPLACED CEILING LIGHT BALLAST AT ROW 1A.Aug 5, 2013 · N748SK · Cndair CL6002C10SDR AALA20130804004Ballast · faultyJFK FLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR IN AFT RT LAVATORY 4F-R. FLIGHT LANDED JFK WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND MIRROR LIGHT SOCKET MELTED. REMOVED BULBS & DISCONNECTED BALLAST. DEFERRED MIRROR LIGHT IAW MEL 33-4Aug 4, 2013 · N760AN · Boeing 777223SDR USAA2013080600001Switch · failedENROUTE, WHEN FWD LAV DOOR WAS CLOSED AND LOCKED, THE FLUORESCENT LIGHT IN LAVATORY WENT OUT. BLACK SMOKE CAME THRU DOOR FRAME. MX FOUND THE FWD LAV DOOR FRAME LIGHT SWITCH MELTED AND SHORTED. MX REPLACED THE FWD LAV DOOR FRAME LIGHT SWITCH. OPS CHECKED OKAug 4, 2013 · N939UW · Boeing 7572B7SDR A6WA201308054027Ballast · odorELECTRICAL ODOR FROM ROWS 1-4 IN CEILING. INSPECTED ROWS 1-5 ABOVE CEILING PANELS FOR EVIDENCE OF ODOR/ANY SIGN OF DISCOLORED AREAS ON WIRES AND INSULATION. FOUND ROWS 2-3 LIGHT BULBS BLOWN SUSPECT BAD BALLAST. R & R BALLAST AND BULBS IAW AMM 33-21-04 ANDAug 3, 2013 · N440AW · Cndair CL6002B19SDR CALA2013082290684Light · improper partDR 1L FWD THRESHOLD LIGHT INOPERATIVE. FOUND INCORRECT LAMP WITH SPEED TAPE ON BASE TERMINAL INSTALLED. RELAMPED IAW SSM LAMP USAGE CHART 33-00-01 PG 101 & MM 33-22-00-201, OPERATIONS CHECKED OKAY.Aug 2, 2013 · N120UA · Boeing 747422SDR DALA1317220668Ballast · damagedF/A REPORTED ELECTRICAL SMOKE ODOR IN FORWARD JUMPSEAT GALLEY AREA. FOUND OVERHEAD GALLEY LIGHTS BALLAST BAD AND CREATING ODOR. R AND R BALLAST AND LAMPS. CKS GOOD, AMM 25-31 AND AMM 33-27.Aug 2, 2013 · N668DN · Boeing 757232SDR CHQA20130722184Ballast · failedAN ELECTRICAL BURNING ODOR IN CABIN NEAR ROW 2 DURING FLIGHT. MX FOUND THE SIDEWALL BALLAST AT ROW 1A TO BE AT FAULT. REPLACED BALLAST. OPS CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.Jul 22, 2013 · N372SK · Emb EMB135KLSDR UALA2013071705010Socket · damagedFWD GALLEY OVERHEAD LIGHT ASSY HAS FOUR INBD BULB SOCKETS DAMAGED DUE TO AGE.Jul 17, 2013 · N523UA · Boeing 757222SDR UALA2013071705025Ballast · malfunctionedHIGH PITCHED NOISE COMING FROM AREA ABOVE 26KL. REPLACED SIDEWALL LIGHT BALLAST, CHECKED OK.Jul 16, 2013 · N664UA · Boeing 767322SDR ASOA20130715112Light · burnedTHE CREW REPORTED A BURNING ODOR IN THE CABIN. MX INSPECTED THE ACFT AND FOUND THE SIDEWALL LIGHT ASSY AT ROW 10 TO BE BURNED. MX R & R THE AFFECTED LIGHT ASSY, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 15, 2013 · N11150 · Emb EMB145XRSDR SWIA201333932Ballast · defectiveLAVATORY LIGHT HAS A BURNING SMELL. FLT#5476 REPLACED THE LAVATORY LIGHT BALLAST.Jul 12, 2013 · N582SW · Emb EMB120ERSDR DALA13034329260Bulb · contaminatedF/A REPORTED PLASTIC BURNING ODOR ON FINAL IN FORWARD RT GALLEY. MX FOUND WIRE TAG MELTED TO WORK LIGHT BULB IN RT GALLEY. REPLACED CEILING LIGHT. OPS CHECKED GOOD. NO ODOR NOTED.Jul 10, 2013 · N960DN · Doug MD9030SDR DALA13035069258Light · overheatedFLIGHT CREW REPORTED READING LIGHT AT 28A OVERHEATING AND STRONG BURNING PLASTIC ODOR. MX R & R LIGHT ASSY 28A IAW AMM. OPS CHECKS OK.Jul 9, 2013 · N958DN · Doug MD9030SDR UALA2013071004811Ballast · inoperativeBALLAST BETWEEN SEAT 1A AND 1B IS INOPERATIVE. 1A SIDEWALL LIGHT IS INOPERATIVE. SIDEWALL LIGHT AT SEAT 1A IS INOPERATIVE. CONNECTOR HAS BEEN REMOVED AND SECURED. THE DISCONNECTION WAS PROMPTED BY A HIGH PITCH NOISE AT SEAT 1A.Jul 9, 2013 · N655UA · Boeing 767322SDR REXA2013070801340Ballast · odorCREW REPORTED ELECTRICAL ODOR COMING FROM OVERHEAD BIN 13AB. FOUND ODOR COMING FROM CEILING & SIDEWALL LIGHTS POWER UNIT DIMMERS/BALLASTS. R & R CEILING & SIDEWALL BALLAST/POWER UNIT DIMMERS IAW AMM 33-21-04 & AMM 33-21-10. OPS CHECKED GOOD.Jul 8, 2013 · N8604C · Cndair CL6002B19SDR A6WA201307084023Ballast · failedSTRONG BURNING ODOR IN CABIN NEAR ROW 3. R & R LIGHT BALLAST ABOVE BIN 5/6 FD IAW AMM 33-10. RESEALED ALL BIN ACCESS DOORS PER AMM SUP 13-018A.Jul 8, 2013 · N466AW · Cndair CL6002B19SDR UALA2013070504676Lamp · odorF/A REPORTED AN ELECTRICAL ODOR AROUND OVERWING EXITS. IMPROVED WITH FLORESCENT BULBS OFF. REPLACED LAMPS IN CEILING LIGHTS AT ROW 23.Jul 4, 2013 · N812UA · Airbus A319131SDR HNAA2013070100378Socket · burnedELECTRICAL ODOR IN FWD CABIN AREA. INSPECTED AND FOUND LIGHT SOCKET AT 3AC BURNED. DEACTIVATED IAW SP33.1. CIRCUIT BREAKERS B1, P3 AND Q3 WERE PULLED AND COLLARD. LIGHTS WILL BE CHANGED.Jul 1, 2013 · N329EN · Dhav DHC8311SDR N6WA2013062701Cover · missingF/A CALL LIGHT COVERS AFT CEILING EXIT SIGN, RED AND WHITE COVERS MISSING.Jun 27, 2013 · N153GJ · Cndair CL6002C10SDR ASOA20130626064Lamp · failedPILOT REPORTED A BURNING ODOR IN THE CABIN APPEARING TO BE COMING FROM THE AIR CONDITIONING PACKS. MX PERFORMED AN OPS CHECK OF THE AIR CONDITIONING PACKS SUCCESSFULLY WITH NO ABNORMAL ODORS COMING FROM THE PACKS. UPON FURTHER INVESTIGATION MX DID DISCOVER AJun 26, 2013 · N22971 · Emb EMB145LRSDR UALA2013062004298Light · burnedAFT GALLEY TABLE TOP LIGHT CAUGHT FIRE, CIRCUIT BREAKER OFF, SMOKE GONE. FOUND LIGHT CASING BURNED, REPLACED LIGHT ASSY IAW MM, OPS CHECKED GOOD.Jun 20, 2013 · N120UA · Boeing 747422SDR UALA2013061904258Power Supply · failedELECTRICAL ODOR IN CABIN. REPLACED GOOSE NECK LIGHT POWER SUPPLY THAT SMELLED OF SMOKE. OP CHECKED GOOD.Jun 18, 2013 · N557UA · Boeing 757222SDR ASOA201306180049Light · burnedCREW REPORTED AN ELECTRICAL ODOR WHILE TAXIING TO RUNWAY. MX INSPECTED AND REPLACED THE CABIN LIGHT ASSY AT SEATS 3B/C AND 4B/C. ALL OPS CHECKS WERE GOOD.Jun 18, 2013 · N12157 · Emb EMB145XRSDR ASOA20130615089Control Module · overheatedTHE CREW REPORTED A PLASTIC ODOR FROM THE CABIN DOOR ENTRYWAY. MX VERIFIED THE ODOR TO BE COMING FROM THE F/A CABIN LIGHT CONTROL MODULE, DEACTIVATED THE MODULE AND PLACED ON MEL, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE. MX R & R THE AFFECTED CABIN LJun 15, 2013 · N16944 · Emb EMB145EPSDR CA130620009Socket · burned(CAN) A FEW MINUTES AFTER TAKING OFF, THE CABIN CREW MEMBER INFORMED THE FLIGHT CREW THAT THERE WAS A BURNING ODOR AND THAT SHE WAS GOING TO CHECK THE CABIN. AFTER LEVELING OFF AT FL 80, WE TURNED OFF THE SEATBELT SIGN AND WHEN SHE WAS READY TO START THE SERVJun 13, 2013 · Dhav DHC8102SDR MASA2013061154278Ballast · failedBURNING OIL ODOR IN AFT CABIN, LAST 5000 FEET IN FLIGHT. MX FOUND A FAILED LIGHTING BALLAST AT ROW 6 AND REPLACED IT.Jun 11, 2013 · N929LR · Cndair CL6002D24SDR ASOA20130610048Lamp · inoperativeTHE CREW REPORTED CABIN SMOKE IN FLIGHT. ALSO REPORTED A GRINDING SOUND NEAR ROW 9 ON RT SIDE OF ACFT. MX INSPECTED AND REPLACED SIDEWALL LAMPS AT ROW 9 AND 10 ALSO REPLACED CEILING, LIGHT LAMP AT ROW 10 & 11. OPS CHECKS WERE GOOD.Jun 10, 2013 · N18120 · Emb EMB145XRSDR ASOA20130531042Socket · burnedCREW REPORTED A BURNED ODOR AT ROW 16A, 17A, 18A. MX INSPECTED AND FOUND BURNED LIGHT SOCKETS.May 31, 2013 · N21537 · Emb EMB145LRSDR DALA1314643605Ballast · inoperativeDURING FLIGHT, THE F/A REPORTED A ELECTRICAL ODOR AT SEAT 26 AREA. MX INSPECTED ACFT AND FOUND SIDEWALL LIGHT BALLAST BAD AT SEAT 16L. REPLACED BALLAST, OPS CHECKED OK.May 30, 2013 · N305DQ · Boeing 737732SDR ASOA20130528054RLamp · arcedF/A REPORTED A BURNING ODOR COMING FROM CEILING LIGHT IN GALLEY ONCE TURNED OFF, THE ODOR DISSAPATED. MX R & R THE GALLEY CEILING LIGHT LAMP WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.May 28, 2013 · N13964 · Emb EMB145LRSDR UALA2013053003777Sign · overheatedREPORT ELECTRICAL ODOR IN FWD CABIN DURING DESCENT. FOUND CENTER AISLE LAVATORY LIGHT SIGN WITH EVIDENCE OF OVERHEATING. REPLACED SIGN, OPS CHECK GOOD.May 28, 2013 · N819UA · Airbus A319131SDR REXA2013052700921Light · inoperativeLIGHT ON THE EMEGENCY EXIT SIGN MID CABIN DOES NOT LIGHT UP WHEN PASSENGER PUSHES F/A CALL BUTTON. R & R BULB IAW AMM 33-51-14. OPS CHECK GOOD. OK FOR SERVICE.May 27, 2013 · N8444F · Cndair CL6002B19SDR SWAA2013052216331Ballast · faultyAIR TURNBACK, STRONG ELEC/RUBBER BURNING SMELL AFTER T/O. DID NOT DECLARE EMERGENCY. NO OVERWEIGHT LANDING. R & R BALLAST IAW MM.May 21, 2013 · N410WN · Boeing 7377H4SDR ASOA20130520080Control Module · overheatedTHE CREW REPORTED AN ELECTRICAL BURNING ODOR BETWEEN THE GALLEY AND COCKPIT. MX INSPECTED THE ACFT AND R & R THE CABIN LIGHT CONTROL MODULE, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.May 20, 2013 · N12175 · Emb EMB145XRSDR REXA2013051900892Light · inoperativeFLIGHT ATTENDANT OVERHEAD PANEL EMERGENCY CALL LIGHT WILL NOT ILLUMINATE. May 19, 2013 · N8924B · Cndair CL6002B19
Back to JASC 3320