JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13041389232Ballast · failedAFT F/A WITNESSED SMOKE AND ELECTRICAL ODOR FROM OVERHEAD LAST ROW OF SEATS. MX FOUND CEILING LIGHT BALLAST FORWARD END AT 37CDE BURNED/SHORTED TO MOUNT SCREW. R & R BALLAST IAW MM. OPS CHECKED NORMAL.SDR HNAA2013082600475Unknown · odorELECTRICAL BURNING ODOR APPEARS TO BE COMING FROM OVERHEAD LIGHTS AT ROW 7DF. R & R LAMP HOLDER, BULB AND BALLAST. OPS CHECKED GOOD.SDR SWIA201334403Cover · missingRED COVER MISSING ON FORWARD FACING MID CABIN FLIGHT ATTENDANT CALL LIGHT. FLT#5505 REPLACED RED COVER ON FORWARD FACING MID CABIN FLIGHT ATTENDANT CALL LIGHT.SDR CHQA20130823325Ballast · inoperativeDURING TAXI, CREW REPORTED A BURNING ODOR AND VISIBLE SMOKE IN THE CABIN COMING FROM THE CABIN LIGHTING BALLAST AT ROW 1. RETURNED TO GATE, REPLACED BALLAST. NO FURTHER DEFECTS HAVE BEEN NOTED.SDR HNAA2013082200471Socket · overheatedHOT ELECTRICAL ODOR OVER ROW 4. INSPECTED AND FOUND OVERHEAD LIGHT 3DF OVERHEATING AT SOCKET AND BASE. REMOVED BULB, PULLED AND COLLARED CIRCUIT BREAKERS S1, S2 AND R2. CABIN INTERIOR NORMAL LIGHTING SYS, R & R SOCKET AT LAMP ASSY ON ROW 3DF. OPS CHECKED GSDR HNAA2013081900470Socket · failedOVERHEAD LIGHT AT ROW 8 IS INOPERATIVE. REMOVED PANEL, FOUND MELTED SOCKET, R & R SOCKET AND BALLAST. REINSTALLED PANEL. OPS CHECKED GOOD IAW CMM 33-21-19.SDR CALA2013090490985Light · inoperativeLT COVER AT GALLEY LT 609 AT ECONOMY GALLEY 431 BURNT. REPLACED LENS 560-3997 & RELAMPED IAW MM, OPERATIONS CHECKED OK.SDR CALA2013081990514Control Panel · shortedCABIN LIGHTS KEEP GOING OUT, CONTROL PANEL BY L1 DOOR SEEMS TO HAVE SHORT. REPLACED PANEL WITH PANEL FROM 5413.SDR CA130815008Socket · burned(CAN) DEFECT-1128460, OVERHEAD CEILING LIGHT ASSY SHOWING SIGNS OF ARCING AT 5DF. RESOLVED ON W/O: 396234 TASKCARD, NR-00009. OVERHEAD BIN AT 5DF LOWERED FOR ACCESS, AND RE-INSTALLED. LAMP HOLDER ASSY REPLACED AT 5DF AND LAMP REPLACED. OVERHEAD LIGHTS AT 5DSDR DXTA2013081505476Switch · failedAFTER LANDING, CABIN INTERIOR LIGHTS WERE TURNED ON. WHEN THE AIRSTAIR DOOR WAS OPENED AND LOCKED IN THE FULL DOWN POSITION ALL THE ENTRY AND CABIN INTERIOR LIGHTS WENT OUT. TROUBLESHOT TO FAULTY GALLEY SWITCH PANEL. R & R SWITCH ASSY IAW MM. SYS OPS CHESDR CALA2013081400566Socket · wornONE OF THE SOCKETS FOR FLUORESCENT MIRROR LIGHT BURNED OUT IN LAV "L", CAUSING ELECTRICAL SMOKE. SOCKET NEEDS TO BE REPLACED. DOME LIGHT WORKS OK. LAV USEABLE. TOMC UPDATE: CHANGED ITEM 33-21-1 TO NEW HARMONIZED ITEM ITEM DEFERRED IAW MEL 33-21-1, CN 651188SDR IPXA13179807Lamp · inoperativeLAV MIRROR LIGHT INOPERATIVE IN DIM. REPLACED LAMPS IAW AMM 33-51-21-401.SDR A6WA2013081200001Light · odorLEFT 14TH DUCT FAILS DUCT TEST. ANIT-ICE PAGE SHOWS DARK-DUCT FROM LEFT VALVE TO LEFT COWL. TEST CAUSES STRONG BURNING ODOR. TROUBLESHOT AND FOUND CONNECTOR P83WK WIRE DISCONNECTED, R&R'D CONNECTOR P83WK PER ESPM 20-17-11 AND PERFORMED OPS CK PER AMM 36-21-00SDR CALA2013080990299Cover · burnedAFT GALLEY LIGHT COVER BURNED. FLT DIVERTED.SDR CALA2013080700546Socket · burnedF/A REPORTED ODOR OF ELECTRICAL SMOKE FROM LAVATORY "L", AFTER INVESTIGATION, IT WAS REPORTED THAT BALLAST FOR FLUORESCENT LIGHT WAS HOT TO TOUCH. AFTER CONSULTING WITH MX, DISCONNECTED BULBS. EVIDENCE OF SCORCHING AT BASE OF ONE BULB. BALLAST COOLED IMMEDSDR SWIA201334157Ballast · failedSTRONG ODOR OF HOT PLASTIC IN FRONT SECTION OF CABIN. FLT#6499 REPLACED CEILING LIGHT BALLAST AT ROW 1A.SDR AALA20130804004Ballast · faultyJFK FLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR IN AFT RT LAVATORY 4F-R. FLIGHT LANDED JFK WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND MIRROR LIGHT SOCKET MELTED. REMOVED BULBS & DISCONNECTED BALLAST. DEFERRED MIRROR LIGHT IAW MEL 33-4SDR USAA2013080600001Switch · failedENROUTE, WHEN FWD LAV DOOR WAS CLOSED AND LOCKED, THE FLUORESCENT LIGHT IN LAVATORY WENT OUT. BLACK SMOKE CAME THRU DOOR FRAME. MX FOUND THE FWD LAV DOOR FRAME LIGHT SWITCH MELTED AND SHORTED. MX REPLACED THE FWD LAV DOOR FRAME LIGHT SWITCH. OPS CHECKED OKSDR A6WA201308054027Ballast · odorELECTRICAL ODOR FROM ROWS 1-4 IN CEILING. INSPECTED ROWS 1-5 ABOVE CEILING PANELS FOR EVIDENCE OF ODOR/ANY SIGN OF DISCOLORED AREAS ON WIRES AND INSULATION. FOUND ROWS 2-3 LIGHT BULBS BLOWN SUSPECT BAD BALLAST. R & R BALLAST AND BULBS IAW AMM 33-21-04 ANDSDR CALA2013082290684Light · improper partDR 1L FWD THRESHOLD LIGHT INOPERATIVE. FOUND INCORRECT LAMP WITH SPEED TAPE ON BASE TERMINAL INSTALLED. RELAMPED IAW SSM LAMP USAGE CHART 33-00-01 PG 101 & MM 33-22-00-201, OPERATIONS CHECKED OKAY.SDR DALA1317220668Ballast · damagedF/A REPORTED ELECTRICAL SMOKE ODOR IN FORWARD JUMPSEAT GALLEY AREA. FOUND OVERHEAD GALLEY LIGHTS BALLAST BAD AND CREATING ODOR. R AND R BALLAST AND LAMPS. CKS GOOD, AMM 25-31 AND AMM 33-27.SDR CHQA20130722184Ballast · failedAN ELECTRICAL BURNING ODOR IN CABIN NEAR ROW 2 DURING FLIGHT. MX FOUND THE SIDEWALL BALLAST AT ROW 1A TO BE AT FAULT. REPLACED BALLAST. OPS CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.SDR UALA2013071705010Socket · damagedFWD GALLEY OVERHEAD LIGHT ASSY HAS FOUR INBD BULB SOCKETS DAMAGED DUE TO AGE.SDR UALA2013071705025Ballast · malfunctionedHIGH PITCHED NOISE COMING FROM AREA ABOVE 26KL. REPLACED SIDEWALL LIGHT BALLAST, CHECKED OK.SDR ASOA20130715112Light · burnedTHE CREW REPORTED A BURNING ODOR IN THE CABIN. MX INSPECTED THE ACFT AND FOUND THE SIDEWALL LIGHT ASSY AT ROW 10 TO BE BURNED. MX R & R THE AFFECTED LIGHT ASSY, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SWIA201333932Ballast · defectiveLAVATORY LIGHT HAS A BURNING SMELL. FLT#5476 REPLACED THE LAVATORY LIGHT BALLAST.SDR DALA13034329260Bulb · contaminatedF/A REPORTED PLASTIC BURNING ODOR ON FINAL IN FORWARD RT GALLEY. MX FOUND WIRE TAG MELTED TO WORK LIGHT BULB IN RT GALLEY. REPLACED CEILING LIGHT. OPS CHECKED GOOD. NO ODOR NOTED.SDR DALA13035069258Light · overheatedFLIGHT CREW REPORTED READING LIGHT AT 28A OVERHEATING AND STRONG BURNING PLASTIC ODOR. MX R & R LIGHT ASSY 28A IAW AMM. OPS CHECKS OK.SDR UALA2013071004811Ballast · inoperativeBALLAST BETWEEN SEAT 1A AND 1B IS INOPERATIVE. 1A SIDEWALL LIGHT IS INOPERATIVE. SIDEWALL LIGHT AT SEAT 1A IS INOPERATIVE. CONNECTOR HAS BEEN REMOVED AND SECURED. THE DISCONNECTION WAS PROMPTED BY A HIGH PITCH NOISE AT SEAT 1A.SDR REXA2013070801340Ballast · odorCREW REPORTED ELECTRICAL ODOR COMING FROM OVERHEAD BIN 13AB. FOUND ODOR COMING FROM CEILING & SIDEWALL LIGHTS POWER UNIT DIMMERS/BALLASTS. R & R CEILING & SIDEWALL BALLAST/POWER UNIT DIMMERS IAW AMM 33-21-04 & AMM 33-21-10. OPS CHECKED GOOD.SDR A6WA201307084023Ballast · failedSTRONG BURNING ODOR IN CABIN NEAR ROW 3. R & R LIGHT BALLAST ABOVE BIN 5/6 FD IAW AMM 33-10. RESEALED ALL BIN ACCESS DOORS PER AMM SUP 13-018A.SDR UALA2013070504676Lamp · odorF/A REPORTED AN ELECTRICAL ODOR AROUND OVERWING EXITS. IMPROVED WITH FLORESCENT BULBS OFF. REPLACED LAMPS IN CEILING LIGHTS AT ROW 23.SDR HNAA2013070100378Socket · burnedELECTRICAL ODOR IN FWD CABIN AREA. INSPECTED AND FOUND LIGHT SOCKET AT 3AC BURNED. DEACTIVATED IAW SP33.1. CIRCUIT BREAKERS B1, P3 AND Q3 WERE PULLED AND COLLARD. LIGHTS WILL BE CHANGED.SDR N6WA2013062701Cover · missingF/A CALL LIGHT COVERS AFT CEILING EXIT SIGN, RED AND WHITE COVERS MISSING.SDR ASOA20130626064Lamp · failedPILOT REPORTED A BURNING ODOR IN THE CABIN APPEARING TO BE COMING FROM THE AIR CONDITIONING PACKS. MX PERFORMED AN OPS CHECK OF THE AIR CONDITIONING PACKS SUCCESSFULLY WITH NO ABNORMAL ODORS COMING FROM THE PACKS. UPON FURTHER INVESTIGATION MX DID DISCOVER ASDR UALA2013062004298Light · burnedAFT GALLEY TABLE TOP LIGHT CAUGHT FIRE, CIRCUIT BREAKER OFF, SMOKE GONE. FOUND LIGHT CASING BURNED, REPLACED LIGHT ASSY IAW MM, OPS CHECKED GOOD.SDR UALA2013061904258Power Supply · failedELECTRICAL ODOR IN CABIN. REPLACED GOOSE NECK LIGHT POWER SUPPLY THAT SMELLED OF SMOKE. OP CHECKED GOOD.SDR ASOA201306180049Light · burnedCREW REPORTED AN ELECTRICAL ODOR WHILE TAXIING TO RUNWAY. MX INSPECTED AND REPLACED THE CABIN LIGHT ASSY AT SEATS 3B/C AND 4B/C. ALL OPS CHECKS WERE GOOD.SDR ASOA20130615089Control Module · overheatedTHE CREW REPORTED A PLASTIC ODOR FROM THE CABIN DOOR ENTRYWAY. MX VERIFIED THE ODOR TO BE COMING FROM THE F/A CABIN LIGHT CONTROL MODULE, DEACTIVATED THE MODULE AND PLACED ON MEL, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE. MX R & R THE AFFECTED CABIN LSDR CA130620009Socket · burned(CAN) A FEW MINUTES AFTER TAKING OFF, THE CABIN CREW MEMBER INFORMED THE FLIGHT CREW THAT THERE WAS A BURNING ODOR AND THAT SHE WAS GOING TO CHECK THE CABIN. AFTER LEVELING OFF AT FL 80, WE TURNED OFF THE SEATBELT SIGN AND WHEN SHE WAS READY TO START THE SERVSDR MASA2013061154278Ballast · failedBURNING OIL ODOR IN AFT CABIN, LAST 5000 FEET IN FLIGHT. MX FOUND A FAILED LIGHTING BALLAST AT ROW 6 AND REPLACED IT.SDR ASOA20130610048Lamp · inoperativeTHE CREW REPORTED CABIN SMOKE IN FLIGHT. ALSO REPORTED A GRINDING SOUND NEAR ROW 9 ON RT SIDE OF ACFT. MX INSPECTED AND REPLACED SIDEWALL LAMPS AT ROW 9 AND 10 ALSO REPLACED CEILING, LIGHT LAMP AT ROW 10 & 11. OPS CHECKS WERE GOOD.SDR ASOA20130531042Socket · burnedCREW REPORTED A BURNED ODOR AT ROW 16A, 17A, 18A. MX INSPECTED AND FOUND BURNED LIGHT SOCKETS.SDR DALA1314643605Ballast · inoperativeDURING FLIGHT, THE F/A REPORTED A ELECTRICAL ODOR AT SEAT 26 AREA. MX INSPECTED ACFT AND FOUND SIDEWALL LIGHT BALLAST BAD AT SEAT 16L. REPLACED BALLAST, OPS CHECKED OK.SDR ASOA20130528054RLamp · arcedF/A REPORTED A BURNING ODOR COMING FROM CEILING LIGHT IN GALLEY ONCE TURNED OFF, THE ODOR DISSAPATED. MX R & R THE GALLEY CEILING LIGHT LAMP WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR UALA2013053003777Sign · overheatedREPORT ELECTRICAL ODOR IN FWD CABIN DURING DESCENT. FOUND CENTER AISLE LAVATORY LIGHT SIGN WITH EVIDENCE OF OVERHEATING. REPLACED SIGN, OPS CHECK GOOD.SDR REXA2013052700921Light · inoperativeLIGHT ON THE EMEGENCY EXIT SIGN MID CABIN DOES NOT LIGHT UP WHEN PASSENGER PUSHES F/A CALL BUTTON. R & R BULB IAW AMM 33-51-14. OPS CHECK GOOD. OK FOR SERVICE.SDR SWAA2013052216331Ballast · faultyAIR TURNBACK, STRONG ELEC/RUBBER BURNING SMELL AFTER T/O. DID NOT DECLARE EMERGENCY. NO OVERWEIGHT LANDING. R & R BALLAST IAW MM.SDR ASOA20130520080Control Module · overheatedTHE CREW REPORTED AN ELECTRICAL BURNING ODOR BETWEEN THE GALLEY AND COCKPIT. MX INSPECTED THE ACFT AND R & R THE CABIN LIGHT CONTROL MODULE, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR REXA2013051900892Light · inoperativeFLIGHT ATTENDANT OVERHEAD PANEL EMERGENCY CALL LIGHT WILL NOT ILLUMINATE.
Back to JASC 3320