JASC 3320

Service difficulty reports · 2,972

Reports filed under 3320 · Passenger Compartment Lighting, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASOA20140611081HBallast · overheatedTHE CREW REPORTED A BURNING ODOR IN THE REAR OF ACFT. MAINTENANCE INSPECTED THE ACFT AND FOUND THE LIGHT BALLAST BEHIND THE LAV MIRROR TO BE OVERHEATED. R & R THE LIGHT BALLAST, OPS TESTED WITH NO DEFECTS. ACFT APPROVED FOR RETURN TO SERVICE.Jun 11, 2014 · N11137 · Emb EMB145XRSDR CALA2014060591210Circuit Board · burnedAT CRUISE 38000' FLIGHT ATTENDANT`S ADVISED OF BURNING SMELL IN THE AFT CABIN. AFTER INVESTIGATING FOUND BURNING, RUBBER SMELL BETWEEN FWD LAVATORY & LAST TWO ROWS OF SEATS. WORK TSM 24-00-00-810-823-A & 05-50-00-810-831-A. FOUND OVEN TRAY WITH BURNED FOOD Jun 3, 2014 · N820UA · Airbus A319131SDR ASOA20140529059Light · arcedCREW REPORTED SMOKE AND SMALL FLAMES COMING OUT OF THE OVERHEAD LIGHTS NEAR ROW 9 & 10. CONTRACT MAINTENANCE PLACED ON MEL 33-20-00-2 AND REMOVED LAMP. MX R & R THE CABIN CEILING LIGHT ASSY ABOVE SEATS 9 & 10 WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURMay 29, 2014 · N11150 · Emb EMB145XRSDR SWIA201437813Ballast · failedELECTRICAL BURNING ODOR IN FLIGHT DECK AND FIRST CLASS. NO SMOKE REPORTED. NO EMERGENCY LANDING DECLARED. REPLACED LIGHT BALLAST.May 28, 2014 · N754SK · Cndair CL6002C10SDR SIMA20140525009Ballast · faultySTRONG ELEC BURNING SMELL EMANATING FROM THE CABIN, NO VISIBLE SMOKE PRESENT. TRANSFERRED TO NRWC 519-ORD-01489. R & R BALLAST PS-75 & R & R FLUORESCENT TUBES ON ROWS 6CD IAW AMM 33-21-09 & 33-21-07. OPERATIONS CHECKED IAW AMM 33-21-00 FOUND GOOD IAW NRWC 5May 25, 2014 · N519AE · Cndair CL6002C10SDR SWIA201437819Light · inoperativeSIDE WALL LIGHT OVER LEFT REAR EMERGENCY EXIT INOPERATIVE. REPLACED SIDE WALL LIGHT.May 24, 2014 · N709SK · Cndair CL6002C10SDR ASOA20140524043CLight · smokeTHE CREW REPORTED SMOKE FROM GALLEY LIGHTS. MAINTENANCE INSPECTED AND REPLACED THE GALLEY LIGHT ASSEMBLY. OPS CHECKED GOOD.May 24, 2014 · N11150 · Emb EMB145XRSDR USAA2014052300001Light · burnedFLIGHT ATTENDANTS REPORTED A MELTING PLASTIC SMELL IN FWD GALLEY DURING TAKEOFF. PERFORMED A330 TROUBLESHOOT CABIN AIR QUALITY JOB CARD. INSPECTED FWD CABIN, LAVATORIES, GALLEYS & CREW REST AREAS FOR SOURCE OF REPORTED SMELL, NONE FOUND. DID INSPECTION OF CMay 22, 2014 · N282AY · Airbus A330243SDR SWIA201437677Ballast · failedBURNED PLASTIC ODOR AROUND ROW 2, OVERHEAD LIGHTS AT SEATS 7A & 7B WENT OUT. REPLACED BALLAST AT ROW 7 A&B.May 21, 2014 · N751SK · Cndair CL6002C10SDR WX0A071947Ballast · defectiveON TAXI OUT FAS CALLED THE FLIGHT DECK REPORTING SMOKE IN THE CABIN COMING FROM THE OVERHEAD BINS. THE SMOKE COULD NOT BE CONTROLLED & THE ACFT WAS EVACUATED. STRONG SMELL, CHEMICAL SMELL, COMING FROM ROWS 15 - 20. BALLAST AT 19L & 20L INOPERATIVE & SMELLSMay 19, 2014 · N415NV · Doug MD83SDR FDEA201405181069Light · inoperativeDURING SERVICE CHECK FOUND LAVATORY EMERGENCY LIGHT NOT ILLUMINATING. REPLACED LAVATORY EMERGENCY LIGHT BULB IAW AMM P TO F SUPPLEMENT 33-26-00 REV 3 4, NOW OK.May 18, 2014 · N920FD · Boeing 75723ASDR ASOA20140516040Light · burnedTHE CREW REPORTED BURNING ODOR COMING FROM LIGHTS ABOVE SEAT 1A, 2A. MAINTENANCE INSPECTED AND REPLACED 1ST 2 LIGHTING ASSEMBLIES FOR OVERHEAD LIGHTS IAW 33-21-06. OPS CHECKED GOOD.May 16, 2014 · N16147 · Emb EMB145XRSDR HNAA2014051400153Socket · damagedOVERHEAD LIGHT AT ROW 4DF IS SPARKED AND SMOKED. CREW POWERED DOWN ACFT. OVERHEAD LIGHTS AND CIRCUIT BREAKER DEACTIVATED. INSPECTED OVERHEAD LIGHTING FOUND ONE SOCKET AT 4DF DAMAGED. REMOVED BULB IAW SP 33.1 AND DEACTIVATED SYSTEM.May 12, 2014 · N810EX · Dhav DHC8102SDR A6WA201441535Ballast · defectiveBURNING WIRE SMELL FROM OVERHEAD BIN ROW 10 RT SIDE. INSPECTED OVERHEAD BIN & FOUND BALLAST AT OVERHEAD BIN ROW 10 D/F INOPERATIVE WITH BURNT SMELL. R & R BALLAST AT OVERHEAD BIN ROW 10 D/F IAW SUPP 13-096, OPERATIONS CHECKED GOOD.May 1, 2014 · N404AW · Cndair CL6002B19SDR A6WA201441465Light · inoperativeROW 13AC CEILING LIGHT INOPERATIVE. CAN SMELL ELEC BURNING ON GND AT GATE.Apr 29, 2014 · N447AW · Cndair CL6002B19SDR CHQA20140428126Ballast · inoperativeCREW REPORTED STRONG BURNING ODOR IN THE FLIGHT DECK & FWD PAX CABIN WITH NO SMOKE PRESENT WHILE EN ROUTE. AN EMERGENCY WAS DECLARED & AN UNSCHEDULED LANDING WAS SUCCESSFULLY PERFORMED. FOUND THE OVERHEAD LIGHTING ABOVE ROWS ONE & TWO WAS FOUND TO BE INOPERAApr 28, 2014 · N372SK · Emb EMB135KLSDR MASA2014042731062Switch · shortedLIGHT SMOKE AND FUMES IN COCKPIT AND CABIN. MAINTENANCE FOUND GALLEY LIGHT SWITCH SHORTED & REPLACED IT.Apr 27, 2014 · N926LR · Cndair CL6002D24SDR ASOA20140419048RControl Module · shortedPILOT REPORTED A STRONG BURNING ODOR NEAR SEAT 1A WHEN THE ACFT WAS POWERED UP. MX R & R THE CABIN LIGHTING CONTROL MODULE ASSY WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 19, 2014 · N16151 · Emb EMB145XRSDR N6WA2014413002Light · inoperativeSTAIR LIGHTS INOPERATIVE. DEFERRED STAIR LIGHTS IAW MEL 33-21-02 CAT D.Apr 13, 2014 · N367CA · Cndair CL6002C10SDR SIMA20140413005Light · inoperativeEMERGENCY LIGHTS OVER FLIGHT ATTENDANT`S SEAT NOT WORKING. R & R COURTESY LIGHT LAMP IAW AMM 33-26-04. OPERATIONS CHECKED GOOD. LAMP USED FROM SPARE BULB KIT.Apr 13, 2014 · N604AE · Emb EMB145LRSDR DXTA2014041405727Light · shortedWHILE OPENING THE CATERING DRAWER THE FWD LED LIGHTING STRIP GOT CAUGHT IN THE DRAWER & PULLED THE LIGHT STRIP PARTIALLY OUT OF THE PROTECTIVE SLEEVE. IT THEN BEGAN SPARKING & SMOKING BEFORE COMPLETELY SHORTING OUT. THE CABIN MASTER SWITCH IN THE COCKPIT IS Apr 11, 2014 · N599QS · Cessna 560XLSDR REXA2014041000370Light · inoperativeMID CABIN FLIGHT ATTENDANT EMERGENCY CALL & AUDIO LIGHT BURNED OUT. REPLACED MID CABIN FLIGHT ATTENDANT EMERGENCY CALL & LAVATORY LIGHTS IAW AMM 33-51-14. PERFORMED OPERATION CHECK OF LIGHTS IAW AMM 33-51-00. OPERATIONS CHECKED NORMAL AT THIS TIME, ACFT OK Apr 10, 2014 · N8946A · Cndair CL6002B19SDR CALA2014041090801Ballast · defectiveBURNING SMELL AROUND ROW 22. TURNED OFF CEILING & SIDEWALL LIGHTS & SMELL WENT AWAY. REPLACED BAD BALLAST AT SIDEWALL 20A IAW IPC 33-21-00 & AT 21F IAW IPC 33-51-51.Apr 9, 2014 · N551UA · Boeing 757222SDR ASOA20140403032Socket · burnedTHE CREW REPORTED CABIN SMOKE. MAINTENANCE INSPECTED AND REPLACED THE SIDE WALL LIGHT FIXTURE BRACKET AT SEAT 10A. OPS CHECKED WERE GOOD.Apr 3, 2014 · N16151 · Emb EMB145XRSDR DALA14020400615Ballast · overheatedFLIGHT DIVERTED DUE TO ACRID ODOR FROM AFT RIGHT SIDE GALLEY. NO SMOKE OR FUMES BUT A ODOR RESEMBLING PLASTIC BURNING. FOUND CHAR MARKS ON OVERHEAD CEILING PANELS AT ROWS 42 ABC AND 40 DEF CAUSED BY OVERHEAD LIGHT BALLASTS. R & R OVERHEAD LIGHT BALLASTS IAWApr 2, 2014 · N615DL · Boeing 757232SDR USAA2014040100008Lens · dislodgedCREW REPORTED THE PLASTIC COVER FOR FIRST CLASS LOW LEVEL LIGHTING FELL OFF. REPLACED MISSING LIGHT LENS 3L AS REQUIRED, OPERATIONS OK.Mar 31, 2014 · N172US · Airbus A321211SDR CALA2014032800402Battery Pack · failedM732 BATTERY PACK TEST FAILED. M732 BATTERY PACK REPLACED & TESTED NORMAL IAW AMM 33-51-07 & AMM 33-51-00.Mar 26, 2014 · N67052 · Boeing 767424ERSDR A6WA201441305Ballast · malfunctionedON A REPO FLIGHT, NO SMOKE OR FLAMES WERE SEEN, NO ODOR WAS DETECTED. THERE WAS NO FLIGHT ATTENDANT AVAILABLE TO GO CHECK THE LAVATORY, SO AN EMERGENCY WAS DECLARED. ON APPROACH AT 5000' RECEIVED SMOKE TOILET MASTER CAUTION, IAW QRH DECLARED EMERGENCY. MSG Mar 22, 2014 · N435AW · Cndair CL6002B19SDR SIMA20140320001Dimmer · burned outELECTRICAL SMELL IN THE FWD GALLEY AREA. PERFORMED TROUBLESHOOTING IAW CRJ FAULT ISOLATION MANUAL 21-22-00. FOUND GALLEY LIGHT POWER DIMMER BURNED OUT, RT. R & R IAW 23-26-03 AM, OPERATIONS CHECKED GOOD.Mar 20, 2014 · N506AE · Cndair CL6002C10SDR CALA2014032090658Light · inoperativeEMERGENCY ESCAPE PATH LIGHT AT SEAT 8B INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY ON MOUNTED SEAT, OPERATIONS CHECKED GOOD.Mar 19, 2014 · N641UA · Boeing 767322SDR CA140317005Power Supply · burned(CAN) CREW TURNED ON POWER TO CARRY OUT PREFLIGHT CHECKS, A STRONG BURNING ODOR WAS NOTICED COMING FROM THE MAIN CABIN. THE CREW TURNED OFF ALL POWER AND NOTIFIED MAINTENANCE. WHEN MAINTENANCE TURNED POWER ON TO TROUBLESHOOT THE PROBLEM IT WAS NOTED THAT 1 SMar 16, 2014 · Bag JETSTM3212SDR ASOA20140308033Light · arcedA BURNED PLASTIC ODOR REPORTED IN CABIN BY SEAT 2A. MX INSPECTED ACFT CABIN AND FOUND SEAT 6A LIGHT TO BE THE CAUSE. MX R & R SEAT 6A CEILING LIGHT ASSY WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 8, 2014 · N14542 · Emb EMB145LRSDR HNAA2014030700073Socket · damagedCABIN OVERHEAD LIGHT AT 8 A/C INTERMITTENT WITH LIGHT ODOR. FOUND LT SOCKET DAMAGED. CABIN OVERHEAD LIGHTS DEACTIVATED CIRCUIT BREAKERS S1, S2 & R2. CABIN INTERIOR NORMAL LIGHTING SYSTEM, SPECIAL PROCEDURE 33.1 HAS BEEN COMPLIED WITH.Mar 5, 2014 · N333EN · Dhav DHC8311SDR CA140307001Socket · burned(CAN) UPON ARRIVAL AT THE ACFT FLIGHT CREW REPORTED AN ELECTRICAL ODOR IN THE CABIN. MAINTENANCE FOUND A BURNED FIX LAMP HOLDER ON ONE OF THE CABIN SIDEWALL FLUORESCENT LAMP FIXTURE. THE LAMP ASSY WAS DISABLED AND THE ACFT RELEASE UNDER MEL. LAMP HOLDER WAS Mar 3, 2014 · Dhav DHC8102SDR CALA2014030390532Socket · damagedELECTRICAL BURNING SMELL AT ROW 16 UPPER DECK. FOUND MELTED SOCKET AT SIDE WALL LIGHT 15A. REMOVED FLUORESCENT LIGHT BULB TO ISOLATE EVIDENCE OF SMELL, INSPECTED AREA IAW FIM 21-00-810, NO MORE SMELL NOTED. REPLACED BURNED SOCKET & RELAMPED, LIGHTS INOPERATFeb 28, 2014 · N178UA · Boeing 747422SDR CALA2014030390526Ballast · inoperativeROWS 37KL & 38KL LOWER SIDEWALL LIGHT INOPERATIVE DUE TO BAD BALLAST. REPLACED BALLAST M764 ON CEILING ABOVE SEAT 38KL IAW WDM 33-21-35. SIDEWALL LIGHTS BY SEATS 37KL & 38KL OPERATIONS CHECKED NORMAL.Feb 28, 2014 · N664UA · Boeing 767322SDR REXA2014022800251Ballast · faultySMOKE TOILET CAUTION MSG ON GND LAVATORY SMOKE DETECTOR SOUNDED. FAINT BURNING SMELL, QRH COMPLETED & SMOKE TOILET CAUTION MSG EXTINGUISHED. DEFERRED, R & R LAVATORY LIGHT BALLAST IAW AMM 33-25-07. OPERATIONS CHECKED GOOD MM02. UPDATED PLACARD REMOVED DMI Feb 28, 2014 · N8928A · Cndair CL6002B19SDR ASOA20140228020Control Module · failedTHE CREW REPORTED F/A AND PASSENGER SMELLED SMOKE IN THE FRONT OF CABIN. MAINTENANCE INSPECTED AND REPLACED THE CABIN LIGHT CONTROL MODULE. OPS CHECKS WERE GOOD.Feb 28, 2014 · N11194 · Emb EMB145XRSDR ASOA20140227025Light · failedSMOKE WAS REPORTED COMING OUT OF CABIN SIDEWALL LIGHTS AT ROW 5BC. MX R & R THE SIDEWALL LIGHT ASSEMBLY AND OPS CHECKED GOOD. ACFT APPROVED FOR RETURN TO SERVICE.Feb 27, 2014 · N11194 · Emb EMB145XRSDR N6WA20140227001Power Supply · overheatedSMOKE IN AFT LAVATORY WARNING WITH VISIBLE SMOKE, AN EMERGENCY WAS DECLARED. INSPECTED & FOUND AFT LAVATORY LIGHT POWER SUPPLY HEATING EXCESSIVELY. R & R LAVATORY LIGHT POWER SUPPLY & ALL OF THE VANITY LIGHT BULBS IAW CRJ700 AMM 33-25-03 & 33-25-05. PERFORMFeb 27, 2014 · N163GJ · Cndair CL6002C10SDR CALA2014022790491Ballast · defectiveROWS 37KL & 38KL LOWER SIDE WALL LIGHT INOPERATIVE DUE TO BAD BALLAST.Feb 27, 2014 · N664UA · Boeing 767322SDR ASOA20140224020Light · burnedCREW REPORTED SMOKE COMING FROM CABIN OVERHEAD LIGHTS AT SEAT 23A. MX INSPECTED AND FOUND LIGHT RECEPTACLE BURNED. R & R SIDEWALL LIGHT ASSY WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Feb 24, 2014 · N14143 · Emb EMB145XRSDR SWAA2014022525528Light · defectiveDIVERSION DECLARED EMERGENCY BURNING RUBBER, FOLLOWED BY ELECTRICAL SMELL AROUND ROW 2 FWD TO OF GALLEY. DIVERTED TO KLIT & DECLARED EMERGENCY. REPAIRED LIGHT IAW MM.Feb 22, 2014 · N296WN · Boeing 7377H4SDR QMLA2014022214017Light · malfunctionedDURING STRAIGHT & LEVEL FLIGHT, THE FLIGHT CREW HAD BOTH THE CABIN REAR NVG LIGHTS ON FOR ABOUT 30 MINUTES OF THE 40 MINUTE FLIGHT. AT 30 MINUTES THEY NOTICED SPARKS & A SMALL PUFF OF SMOKE COME OUT OF THE LIGHT SOCKET AREA. NOTICED SMOKE RESIDUE AROUND THE Feb 22, 2014 · N4497Y · Urocop AS365N3SDR REXA2014022100231Bulb · inoperativePASSENGER CALL LIGHT IN THE OVERHEAD EMERGENCY EXIT SIGN OVER ROW 8 IS INOPERATIVE. THE REAR LIGHT IS INOPERATIVE, THE FWD LIGHT IS FUNCTIONING PROPERLY. REPLACED BULB. OPS TESTED OK IAW AMM 33-22-03.Feb 21, 2014 · N8412F · Cndair CL6002B19SDR SWIA201436349Light · faultyBURNING SMELL IN LAVATORY. FLT 2591 REPLACED LAVATORY LIGHT ASSEMBLY.Feb 16, 2014 · N466SW · Cndair CL6002B19SDR ASOA20140215014RControl Module · faultyPILOT REPORTED THE MAIN CABIN LIGHTS WOULD NOT TURN OFF WITH A STRONG ELECTRICAL ODOR COMING FROM SEAT 1A. MX R & R THE CONTROL MODULE ASSY FOR THE CABIN LIGHTING WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Feb 15, 2014 · N14907 · Emb EMB145LRSDR REXA2014021400207Cover · missingFLIGHT ATTENDANT`S CALL LIGHT COVER ON EMERGENCY EXIT SIGN MISSING. INSTALLED FLIGHT ATTENDANT`S CALL LIGHT COVER IAW AMM 33-51-14.Feb 14, 2014 · N8976E · Cndair CL6002B19SDR SWIA201436072Ballast · defectiveSTRONG ELECTRICAL SMELL IN THE LAVATORY. FLT4547 REPLACED LAVATORY LIGHT BALLAST ASSEMBLY.Jan 19, 2014 · N440SW · Cndair CL6002B19SDR ASOA20140113009Ballast · failedTHE CREW REPORTED AN ELECTRICAL ODOR IN THE BACK OF THE CABIN. MAINTENANCE INSPECTED THE ACFT AND R & R THE LIGHT BALLAST AT ROW 28 ON THE RT SIDE. OPS CHECKS PERFORMED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jan 13, 2014 · N22971 · Emb EMB145LR
Back to JASC 3320