SDR AALA202603182527Light · burned outAIRCRAFT WAS GROUNDED: 4L LAV AS STRONG ODOR OF SMOKE, NO SMOKE PRESENT, TOILET WAS BLOCKED/PAPER REMOVED AND H20 POURED INTO TRASH BIN NO INDICATION IN COCKPIT. MAINTENANCE FOUND LAV MIRROR LIGHT PARTIALLY MELTED AND BURNED. REPLACED 4L LAV MIRROR LIGHT ASSY.SDR CALA2026031014480Switch · stickingFA CREW REST HAS NO POWER OR LIGHTS FOUND LIGHTING CONTROL PANEL AT OHAR ENTRY DOOR BUTTONS STICKING. DOES NOT BREAK FOR SWITCH ASSY. INDIVIDUAL SWITCHES ARE SODERED IN FOUND THE SWITCHES ON THE OHAR CONNTROL PANEL STICKING. PULLED OUT EACH SWITCH CAP AND CSDR CALA2026022013946Ballast · faultedMOMENTARY SMOKE OUT OF 1ST CLASS OVERHEAD ENTRY LIGHT, NO EVIDENCE OF FIRE LOCATED SOURCE OF SMOKE ODOR TO FORWARD ENTRY BALLAST. REMOVED AND REPLACED FWD ENTRY LIGHT BALLAST REF AMM 33-29-00. OPS CHECKED GOOD, NO SMOKE PRESENT.SDR IXXA20260218013Lamp · malfunctionedEMERGENCY DOORS DISCRETE LIGHT FLICKERS ON IN FLIGHT. IAW FIM 32-09 FAULT TREE 803, NO FAULTS NOTED. VERIFIED S192 AND S193 . RESEATED THE LAMPS IN EMERGENCY DOOR ANNUNCIATOR IAW AMM 33-16-02. OPS CHECKED GOOD.SDR SWAA2026021771061Psu · faultedREADING LIGHT AT SEAT 11A WILL NOT TURN OFF, HEAT ODOR. CW SMOKE IN CABIN INSPECT IAW FIM 21-00, TASK 806. NO DEFECTS FOUND. REMOVED PSU AT SEAT 11A IAW AMM 25-23-61, INSPECT AND REINSTALLED, NO DEFECTS NOTED. ACFT OK FOR SERVICE.SDR DALA2026021701069Light · not reportedAFT MIDDLE LAVATORY LAV 203 LOWER VANITY SINK LIGHT REMOVED FOR ODI EVENT. LAV 203 LOWER VANITY SINK LIGHT REMOVED AND CONNECTOR CAPPED AND STOWED PER ER/A 3259-1451749 REV. ORIGINAL. PLACING LIGHT ON MEL 33-50-06. NO "M" PROCS. REQUIRES P/N: 8200001623PBL23 SDR DALA2026021701068Light · overheatedELECTRICAL BURNING ODOR COMING FROM LAV 203. ALL LIGHTS REPORTING TO BE INOP. C/W NO GO ODI CHECK LIST, PERFORMED STEPS 1-4 OF W/C 0550-2002. SMOKE AND FUMES FORM SUBMITTED BY CREW. FOUND C/B J1 @ 2000VU PANEL POPPED, FOUND LAV 203 MIRROR LIGHT OVERHEATED. CSDR CALA2026021713850Lamp · burned outAFT ENTRY ANNUNCIATOR LIGHT BURNED OUT. REPLACED THE LAMPS OVERHEAD PANEL AFT ENTRY ANNUNCIATOR LIGHT IAW AMM 33-18-00-960-801. LIGHT ILLUMINATES OPS CHECKED GOOD, OK FOR SERVICE.SDR SCNA20260210065Light · looseFA STATES ROW 12 ABC FLOOR WALKWAY ILLUMINATING STRIPS BUCKLED AND COMING UP. TAPED ROW ABC WALKWAY ILLUMINATING STRIP IAW AMM 25-63-00SDR IPXA20260209570Lamp · inoperativeTHREE MDCC LOADING AREA LIGHTS INOPERATIVE. REMOVED AND REPLACED THE THREE LIGHT LAMPS IAW 33-34-41. OPS CHECK GOOD, NO DEFECTS NOTED.SDR CALA2026012813404Light · inoperative20A EMERGENCY EXIT WINDOW LIGHT INOPERATIVE. RELAMPED TWICE, CHANGED FUSE, NO HELP. WINDOW LIGHT OVERWING EXIT. EMERGECY LIGHTS WORK, WINDOW LIGHT DOES NOT. REQUEST MEL APPROVED NEW BALLAST ASSEMBLY, FWD TO MEL 3302B, REPLACED THE LT FWD OVERWING EMERGENCSDR CALA2026012313183Light · malfunctionedLIGHT ON 21F. ALL OTHER INDICATIONS NORMAL. LIGHT IN QUESTION IS 25F SIDEWALL LIGHT, NOT EMERGENCY LIGHT. CYCLED CB FOR RT SIDEWALL LIGHTS. SIDEWALL AND EMERGENCY LIGHT OPERATION NORMAL AND AS COMMANDEDSDR CALA2026012113124Bulb · failedFA REPORTS POSSIBLE VAPOR OR SMOKE VISIBLE BEHIND OVERHEAD LIGHT LENS IN AFT GALLEY. PERFORMED A VISUAL INSPECTION FOR EVIDENCE OF BURNING OR ARCING. FOUND THE AFT CENTER FLUORESCENT LIGHT BUZZING & FLICKERING. FOUND THE AFT GALLEY NIGHT LIGHT BURNT OUT, RESDR CALA2026012313184Light · damagedSEAT 3D EMERGENCY EXIT LIGHT DAMAGED, INOP. REQUESTING MEL. ALL OTHER LIGHTS OK. MEL 3351V APPROVED SECURED LIGHT. PLACED ON MEL. INSTALLED NEW EMERGENCY EXIT LIGHT, AISLE SIDE, AT SEAT 3D AND EMERGENCY LIGHT AT 3D OPS CHECKED GOOD.SDR SWAA2026011962034Light · inoperativeLIGHT WAS FLICKERING ON CAPTAIN SIDE AROUND ROW 11 LIGHT WAS FLICKERING ON CAPTAIN SIDE AROUND ROW 11.FLIGHT ATTENDANT NOT SURE IF IT BURNT OUT BUT STRONG ODOR OF SOMETHING THAT MAY HAVE BURNT OUT.FLIGHT ATTENDANTS TURNED OFF LIGHTS AND SMELL DISSIPATED. REPSDR SCNA20260116030Light · failedELECTRICAL FUMES STRONGLY FILLED THE CABIN AFTER TAKEOFF. CABIN LIGHTS(OVERHEAD LIGHTS) IMEDIATLEY FAILED WITH FUMES. (PASSENGERS REPORTED A HAZE IN CABIN) REF. LP 826002 ITEM 2 IDG SERVICED CORRECTLY AND HIGH POWER RUN C/W REF. AMM 71-00-00 NO DEFECTS NOTED OSDR CALA2026011613008Bulb · burned outON TAXI OUT, FA SAYS A STRONG ODOR OF BURNED RUBBER OR GAS APPARENT FROM ROW 38 AFT. DID NOT DISAPATE. PERFORMED CABIN INSPECTION, IAW AMM 05-51-58-910-801-C1. FOUND BURNED LIGHT BULB AT LOCATION ROW 38 RT OVERNEAD BIN , IAW FA, IT WAS LIKE RUBBER OR ELECTRISDR SWAA2026020660197Light · inoperativeEMERGENCY WINDOW LT SIDEWALL LIGHT INOPERATIVE. PERFORMED EXIT SIGNAL EMERGENCY WINDOWS LT SIDEWALL LIGHT OPS TEST IAW AMM 33-51-00-710-801, TEST PASSED.SDR SWAA2026011259231Lens · detachedSIDEWALL LIGHT LENS ROW 8 DEF FELL OFF. SECURED WINDOW LIGHT LENS IN PLACE IAW SIP.SDR SCNA20251226506Lens · deterioratedRIGHT FWD EMERGENCY EXIT DOOR ROW 15DEF LIGHT LENS DERIORATED.DECRATIVE PAINT CHIPPED. TOUCH UP PAINT LIGHT AT ROW 15 DEF IAW AMM 51-21-99.SDR SCNA20251218495Lamp · inoperativeNO SMOKING LIGHTS INOP AT THE FOLLOWING SEAT LOCATIONS: 6D, 11D, 29D, 10A, 19A RELAMPED NO SMOKING LIGHTS 6D, 11D, 29D,10A,AND 19A REF AMM 33-25-00. OK FOR SERVICESDR DALA2025121209109Light · failedENROUTE FA'S NOTIFIED OF BURNING SMELL NEAR DOOR 2L. INDENTIFIED FUME COMING FROM CEILING NEAR LIGHTS. NO SMOKE. INSTRUCTED FAS TO TURN OFF CABIN LIGHTS SMELL DISAPIATED. QRH 8.4 COMPLIED WITH. PERFORMED OPS TEST OF CEILING LTS, FOUND BURNING SMELL FROM OVERSDR SCNA20251208464Lamp · inoperative14DEF NO SMOKING LIGHT INOPERATIVE. REMOVED AND REPLACED 14DEF NO SMOKING LAMPS IAW 33-25-00, OPS CHECKED GOOD.SDR CALA2025120511786Light · inoperativeOVERWING EMERGENCY EXIT CABIN WINDOW LIGHT 20A INOPERATIVE. REPLACED OVERWING EXIT WINDOW LIGHT ASSY IAW AMM 32-21-00-960-802. OPS CHECKED GOOD.SDR SWAA2025120140319Lamp · inoperativePASSENGER CALL LIGHT IN THE AFT GALLEY INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-01. OPS CHECKS GOOD.SDR 2025FA0000786Switch · meltedPASSENGER READING LIGHT CONTROL STARTED SMOKING AFTER IT WAS SELECTED ON, SWITCH PLASTIC CONTINUED TO MELT DURING TAKEOFF ROLL. TAKEOFF WAS ABORTED AIRCRAFT POWER REMOVED AND SMOKE STOPPED IMMEDIATELY.SDR FDEA202511192190Lamp · inoperativeR1 DOOR SLIDE LIGHT INOPERATIVE. RELAMPED R1 DOOR SLIDE LIGHT IAW AMM 33-51-06-2. OPS CHKD SERVICEABLE.SDR REXA2025112000986Light · odorFA REPORTS FLOOR LIGHT BY MAIN CABIN DOOR BURNT OUT. ASSOCIATED W/ EMER LIGHTS. REMOVED AND REPLACED FLOOR LEVEL EMERGENCY FLOOD LIGHT IAW CRJ700 AMM 33-51-11. ALL CHECKS GOOD.SDR CALA2025110610937Light · no discrepancyOVERHEAD LIGHTING AT L1 DOOR FOUND INOPERATIVE ON ARRIVAL AT GATE, PROBLEM WAS RESOLVED. OPERATED FWD GALLEY LIGHTS WITH SLIDE ARMED & DISARMED, AS WELL AS WITH FLIGHT DECK DOOR OPEN AND CLOSED. ALL WORKS PROPERLY. GOOD FOR SERVICE.SDR SWAA2025110631261Light · inoperativeSIDEWALL LIGHTS INOPERATIVE FOLLOWING LOCATIONS: ROW 12 & 18 RH SIDE, ROW 14 LT SIDE. REPLACED THE LAMPS 12 AND 18 DEF AND 14 ABC SIDEWALL LIGHTS IAW AMM 33-21-00.SDR SWAA2025112630874Battery Pack · inoperativeINOPERATIVE BATTERY PACK BELOW SIDEWALL PANEL 232YHW AT PASSENGER CABIN. REPLACED BATTERY PACK BELOW SIDEWALL PANEL 232YHW AT PASSENGER CABIN IAW AMM 33-51-06-960-805, EXCEPT TO STEP 4.E.(3)(A)(F) AND STEP 4.F.(1)(4) TEST IS OK.SDR SCNA20251104429Lamp · inoperativeSEVERAL NO SMOKING / FASTEN SEAT BELT LIGHTS OUT. RELAMPED PER MM 33-25-00. OK FOR SERVICE.SDR CALA2025102410476Light · malfunctionedEMER EXIT LIGHT OVERWING RIGHT SIDE AND OVERWING FORWARD POSITIO N ON CONTINUOUSLY. CYCLED BREAKERS LIGHTS EXTINGUISHED AND FUNCTION NORMALSDR VNAA2025102411101Light · odorELECTRICAL BURNING ODOR IN BETWEEN SEAT 3 AND 8 DF / REMOVED AND REPLACED SIDE WALL LIGHT SEAT 8AC AND 9AC IAW SWPM 20-16-00 AND AMM 33-21-07-000/400-801-A01 OPERATIONAL TEST GOOD. NO BURNING ODOR NOTICED.SDR CALA2025102010305Light · malfunctionedCABIN ENTRY LIGHT NEAR DOOR 1R FLASHES RED INTERMITTENTLY RESET LIGHTS FOR FWD ENTRY DOOR, PROFORMED OPS CHECK REF AMM 33-21-00-710-001-A, NO FAULTS NOTED, OK TO CONTINUE.SDR SCNA20251021399SBattery Pack · no testR1 EXIT SIGNS AND SLIDE LIGHT EMERGENCY LIGHTS DO NOT COME ON DURING TEST. REMOVED, REPLACED AND PERFORMED SATISFACTORY OPS CHECK AT BATTERY PACK FOR R1EXIT SIGN AND SLIDE EMERGENCY LIGHT IAW B737AMM 33-51-06SDR SCNA20260218088Light · inoperativeFWD & AFT GALLEY NO SMOKING SIGNS ARE NOT ILLUMINATED. NO SMOKING LIGHTS DEACTIVATED FOR SKY INTERIOR REF AMM 33-20-00SDR CALA2025100109502Battery Pack · dischargedOFCR BACKUP POWER SUPPLY BATTERY, FOUND TO HAVE LOW CAPACITY. REPLACED OFCR BACKUP POWER SUPPLY BATTERY PACK AND TESTED NORMAL IAW AMM 33-29-10-960-810, REV 104.SDR AALA202510021533Ballast · failedAIRCRAFT WAS GROUNDED: FUME EVENT, AT ABOUT 12 MILE FINAL, 3000 FT FLIGHT ATTENDANTS IN THE REAR REPORTED AN ELECTRICAL SMELL FOR 5 MINUTES WHICH EVENTUALLY CLEARED AFTER SELECTING BLOWER AND EXTRACT TO OVRD. MAINTENANCE FOUND AFT GALLEY RH WORKING LIGHT BALLASDR IXXA20280925055Bulb · inoperativeFORWARD FLIGHT ATTENDANT'S EMERGENCY CALL LIGHT IS INOPERATIVE. PLACED ON DEFERRAL 66475 MINIMUM EQUIPMENT LIST 23-41-01-04 CATEGORY B. DUE 28 SEPTEMBER 2025. REPLACED BULB AD ACCOMPLISHED SYSTEM TEST IN ACCORDANCE WITH B757 AIRCRAFT MAINTENANACE MANUAL 23-42-SDR AALA202509230122Light Sys · inoperativeAIRCRAFT IN BASE MAINTENANCE: THE AFT LEFT LAV LIGHTS ARE INOPERATIVE. DECESION MADE TO RETURN TO CLT DUE TO FWD LAV ON MEL. EMREGENCY DECLARED AND AIRCRAFT LANDED OVERWEIGHT WITHOUT ISSUE. MAINTENANCE FOUND LAVS POWER SWITCHED OFF ON THE FWD LIGHT ATTENDANT PSDR CALA2025091108754Control Panel · malfunctionedLIGHT ON PANEL 2L INOPERATIVE, CONFIRMED LT CONTROL PANEL AT L2 DOOR WOULD NOT COMMAND THE AFT ENTRY LIGHTS ON. RESET CONTROL PANEL. AFT ENTRY LTS NOW COMMAND NORMAL. IAW AMM 33-21-00-710-801SDR CALA2025091008710Lamp · inoperativeDOOR 1R ENTRY LT INOP. REQUESTING MEL 3320A MEL 3320A APPROVED STICKER APPLIED. RELAMPED OPS CHECK GOOD.SDR VNAA2025090511101Power Unit · overheatedBURNING SMELL ABEAM WARDROBE / T/S PER FIM 21-22-00-810-806-A01 AND CEILING LIGHT POWER UNIT/DIMMER AT SEAT ROW 1A FOUND OVERHEATED, REMOVED AND REPLACED POWER UNIT/DIMMER IAW AMM 33-21-03-000/400-801-A01. PERFORMED OPERATIONAL TEST OF PAX COMPARTMENT LIGHT ISDR CALA2025090408477Light · detachedTRIM PIECE WITH LIGHT ON OVERHEAD AT 30ABC IS LOOSE. HANGING B Y WIRE. CURRENTLY SECURED IN O/H RESECURED OVERHEAD BIN/PSU BULLNOSE TRIM AT 30-32ABC. NO DEFECTS NOTED AT THIS TIME.SDR CALA2025090208348Lamp · failedSMOKE SMELL INTERIOR AFT LEFT MUST FOLLOW AND REFERENCE AMM 05-51-50 CONDITIONAL INSPECTION - SMOKE OR FUMES IN CABIN. ALSO SUBMIT REQUIRED SMOKE/ODOR IN THE PLAN QUESTIONNAIRE FORM 46-6020 PERFORMED ALL TEST. ALL LIGHTS OPS NORMAL IN THE CABIN. FOUND ROM 46ASDR AALA202508158691Ballast · burned outAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORT BURNT SMELL IN AFT GALLEY. PERFORMED JOB CARD 08L00021001. DURING TROUBLESHOOTING TRACED ODOR TO AFT GALLEY CEILING LIGHT ELECTRONIC BALLAST. ALSO, FOUND BALLAST OVERHEATING. REPLACED BALLAST, PER AMM 33-26-02. OSDR SWAA2025091500067Light · inoperativeFOUND AN AISLE LIGHT INOPERATIVE BETWEEN ROWS 18-19 DEF. REPLACED LAMP AISLE LIGHT BETWEEN ROW 18-19 DEF AND GOOD TEST IAW AMM 33-51-03-960-802.SDR SWIA2025080500001Ballast · failedBURNING ELECTRICAL SMELL THROUGH OUT THE AIRPLANE. (FLIGHT 6240) UPON ARRIVAL TO AC, INTERROGATED EVIDENCE OF ELECTRICAL BURNING SMELL AND COULD NOT SMELL OR SEE ANY EVIDENCE OF SAID ELECTRICAL SMELLS IN AC. HAD SERVAL MXS COME ON BOARD TO VERIFY, AND EVERY MSDR ASAA2025073159855Sign · meltedAFTER TAEKEOFF PASSING 4000' FLIGHT ATTENDANT IN AFT CALLED TO REPORT AFT NO SMOKING SIGN FLICKERED AND WAS HOT TO THE TOUCH. ALSO SMELLED BURNING PLASTIC SMELL. GROUNDED - YES. UNABLE DUPLICATE THE DEFECTS PLASTIC BURNING ODOR THAT FLT ATT REPORTED. GVI NO DI
Back to JASC 3320