JASC 3320
Service difficulty reports · 2,971
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20261012422Light · inoperativeLEFT FWD OVERWING EMERGECY EXIT DOOR HANDLE LIGHT INOP. OPENSDR SCNA20261012421Light · inoperativeLEFT AFT OVERWING EMERGENCY EXIT DOOR HANDLE LIGHT INOPERATIVE. OPENSDR DALA2026101305620Lamp · inoperativeOVERWING EMERGENCY EXIT HANDLE LIGHTS INOPERATIVE ALL 4 DOORS. RELAMPED, OPS NORMAL. (LP 9099331 - AIRCRAFT WAS GROUNDED)SDR CALA2026100520069Light · inoperativeFWD GALLEY OVERHEAD LIGHT INOPERATIVE. SUFFICIENT LIGHT IN GALLEY. AFFECTED LIGHT IS THE WORK LIGHT ABOVE DOOR 1R. FOUND WORK LIGHT WITH BURNED CONTACTS IN LIGHT ASSEMBLY. REMOVED THE LAMP. WORK ACCOMPLISHED IAW AMM 33-26-02-960-801. CAPPED AND STOWED BASDR CALA2026100520106Ballast · faultedCREW REPORTS ELECTRICAL BURNING ODOR IN AFT GALLEY, DURING GROUND OPS. PERFORMED SMOKE/ODOR CONDITIONAL INSPECTION IAW AMM 05-51-26. FOUND AFT GALLEY OVERHEAD LIGHT BALLAST M1843 TO BE THE CAUSE. PULLED, CAPPED AND STOWED CONNECTOR FROM BALLAST IAW GMM 05-SDR CALA2026092919981Light · inoperativeCABIN LIGHTS , OPS CHECK PROCEDURE, SIDEWALL WINDOW LIGHT AT EMERGENCY EXIT ROW 21ABC INOPERATIVE. REMOVED AND REPLACED EMERGANCY EXIT ROW 21ABC WINDOW LIGHT. OPS CHECK GOOD. IAW AMM 33-21-00-960-807.SDR CALA2026092819849Light · abnormalROW 21DEF EMERGENCY EXIT DOOR FLOURESENT LIGHT IS FLICKERING REQUESTING MEL FOR RT. SIDE WINDOW LIGHTS INOP. RESET NO HELP. C/B PULLED ON P92 E-11 RT WINDOW LTS. VERIFIED EMERG. EXIT LIGHTS WORKING PROPERLY TOMC APPROVED IAW MEL 3302B CONFIRMED EMERGENCY EXIT SDR SWAA2026092573795Light · inoperativeCABIN SIDEWALL LIGHTING ADJACENT TO ROWS 25, 26, 27 SEATS DEF WERE INOPERATIVE. R & R WINDOW LIGHTS AT ROWS 23DEF & ROW 16DEF IAW AMM 33-21-00.SDR SWAA2026092237909Light · smokeFA OBSERVED A BURNING ODOR IN AFT GALLEY AT GATE AFTER LANDING NEAR SERVICE DOOR. COMPLIED WITH SMOKE/FUMES IN CABIN CONDITIONAL INSP IAW MM 05-51-56 RELAMPED AFT GALLEY ENTRY LIGHT IAW MM 33-29-00. NO OTHER DEFECTS FOUNDS.SDR CALA2026091519443Lamp · failedUPPER SIDE PANEL LITES OUT OVER SEATS 14F 18F 9A 3F 1A CONFIRMED SIDEWALL LIGHTS ARE OUT AT SEATS 14F, 18F, 9A,3F & 1A. CABIN INTERIOR ILLUMINATION SYSTEM LIGHTING IS SUFFICIENT FOR CABIN ATTENDANTS TO PERFORM THEIR DUTIES AND AT LEAST 75 PERCENT OF THE NIGHTSDR CALA2026091719494Light · faultedOVERWING EMERGENCY EXIT DOOR WINDOW LIGHT GOING BAD AND FLICKERING ON 21DEF FO SIDE. PLACED ON MEL. PULLED BREAKER TO PREVENT FLICKERING (P92 E13) IAW WDM 33-21-11. SUFFICIENT LIGHTING REMAINS FOR FLIGHT CREW TO PERFORM DUTIES. TOMC APPROVED MEL 3321A FOR 21DSDR SWIA2026082876970Ballast · failedPASSENGER LIGHT OVER 1 A BEGAN FLICKERING AND SMOKE BEGAN TO COME OUT OF THE LIGHT AREA. (FLIGHT 4324)TROUBLESHOT SMOKE IN CABIN IAW FIM 21-22-00-810-806. PERFORMED OPS CHECK OF AC DISTRIBUTION SYSTEM IN REFERENCE TO AMM 21-51-00 PER FIM. NO SMOKE OR ABNORMALSDR IPXA2026082163543Bulb · burned outLAV AUX LIGHT INOPERATIVE. REPLACED LAV AUX LIGHT BULB IAW AMM 33-51-21, OPS CHECKED GOOD.SDR SWIA2026081976926Ballast · odorSMOKE FUME ODOR IN FLIGHT DECK (FLIGHT 4976) CORRECTIVE ACTION REPORTED SMOKE/FUME SMELL IN FLIGHT DECK WAS TROUBLESHOOT IAW FIM 21-21-00 AND 79-30-00. VERIFIED NO VISIBLE SMOKE PRESENT, ODOR ONLY, & NO 30 DAY HISTORY. REF CP 32864233 FOR PRESSURIZATION CHECSDR DXTA2026082009327Light · inoperativeREADING LIGHT ABOVE THE LAV SEAT IS INOPERATIVE WITH THE EMERGENCY LIGHT ON; HOWEVER, THE LIGHT DOES ILLUMINATE WITH THE PUSH BUTTON DIRECTLY BELOW THE LAV FLUSH BUTTON. PREFORMED OPS CHECK OF EMER LIGHTS. OPS CHECK GOOD. THE LAV READING LIGHT IS NOT APART OSDR AALA202608122622Light · shortedAIRCRAFT WAS NOT GROUNDED: LED LIGHT STRIP INSIDE CHILLER OF GALLEY 2 HAS BURNT OUT AND CAUSED A SHORT WITH EXPOSED WIRE. MAINTENANCE REPLACED LED LIGHT STRIP IAW CMM 25-24-22.SDR U5QA202608060174Ballast · odorSTRONG ELECTRICLAL BURNGING ODOR EMINATING IN AFT LAV AREA. SOURCE UNKNOWN. REMOVED AFT LAV VANITY MIRROR DIFFUSER/SURROUND AND SIDE WALL PANEL. FOUND THE VANITY MIRROR LEFT SIDE AND BOTTOM FLUORESCENT TUBE INOPERATIVE. IAW WM 33-28-50-001 BOTH LAMPS POWERED SDR SWAA2026081009820Lamp · inoperativeOVERWING EXIT DOOR LIGHT RT SIDE, INOPERATIVE. OK TO CONTINUE IAW MEL 33-2-03. SP1B, MDDR 333138. REPLACED THE LAMPS IN THE RT OVERWING EXIT DOOR WINDOW LIGHT IAW AMM 33-21-00. OPS CHKD GOOD.SDR DXTA2026080709142Light · inoperativeTOE KICK LIGHTING UNDERNEATH TOILET ALONG FLOOR IN VANITY AREA INOP. REINSERTED GROUND PIN. OPS CHECK GOOD. IAW CITATION SPM 20-30-20SDR CALA2026080618340Light · faultedEMERGENCY EXIT LIGHT OUT ROW 20 ACFT RT PICTURE OF LIGHT, LIGHT WORKS WHEN EMERGENCY LIGHTS TURNED ON. LIGHT DOES NOT WORK WHEN EMERGENCY LIGHTS OFF. DEFERRED IAW MEL 3321A, EMERGENCY LIGHTS NOT AFFECTED, SEE AMM 33-21-00-960-802, R & R OVERWING WINDOW LIGSDR DALA2026073004420Light · inoperativeFOUND FWD AISLE LIGHT INOP. R & R AISLE LIGHT PER AMM 33-21. OP CKS GOOD. ACFT OK FOR SVC. (9223777) AIRCRAFT GROUNDED.SDR AALA202607307783Light · odorAIRCRAFT WAS GROUNDED: FA S REPORTED ELECTRIC SMELL IN AFT GALLERY CAUSES HEADACHES AND NAUSEA. MAINTENANCE FOUND AFT GALLEY WORK LIGHTS DEFECTIVE ( ELECTRICAL SMELL ) ABD REPLACED LIGHTS IAW AMM 33-26-02.SDR AALA202607277022Lamp · burned outAIRCRAFT WAS NOT GROUNDED: 5L FLIGHT ATT JUMP SEAT WORK LIGHT NR 1 INOPERATIVE. MAINTENANCE RELAMPED USING ONBOARD SPARE LAMP FROM SPARE LAMPS CHK OK REF AMM 33-23-00.SDR IPXA2026072435588Bulb · inoperativeLAV AUX LIGHT INOP REMOVED AND REPLACED LAV AUX LIGHT BULB REF AMM 33-51-21, OPS CHECK GOOD.SDR CALA2026071217675Channel · corrodedLEFT AFT CARGO COMPARMENT ZEE CHANNEL BS 727 TO 847. REMOVED AND REPLACED AFT CARGO LT SIDE ZEE CHANNEL SIDE PLATE FROM BS 727 TO 847 IAW SRM 51-40-02-0G-0, SRM 53-00-53-2R-5, PAR. 4,D., SRM 51-40-05-0G-0, SRM 51-40-08-0G-0.SDR IPXA2026070192800Light · no discrepancySMALL LIGHT IN LAV INOP. FOUND SMALL AUX LAV LIGHT TO BE OPERATIONAL WHEN DOOR IS LOCKED. IAW AMM 33-51-21SDR IPXA2026062992800Light · inoperativeSMALL LIGHT IN LAV INOP.SDR CALA2026062217223Ballast · inoperativeCONTROL CABIN AND PASSENGER CABIN VISUAL INSPECTION. SIDEWALL LIGHT FOR AFT OVERWING EMERGENCY EXIT. INOP RELAMPED NO HELP, REPLACED BALLAST FOR R/H AFT OVERWING EMERGENCY EXIT SIDEWALL LIGHT, REF AMM 33-21-30. OP CHECK GOODSDR A6WA202606058892Ballast · odorINTERMITTENT SMELL OF HOT WIRING BETWEEN ROWS 8-12 ON THE GRD. AIRCRAFT REMOVED FROM SERVICE. R & R LIGHT BALLAST AT ROW 10AB IAW AMM 33-21-04 AND UNUSUAL ODOR. OPS CHKD GOOD.SDR KCSA2026053131Control Unit · faulted100288228: BUNK LIGHTS INOP. REMOVED AND REPLACED ZONE MANAG. UNIT (ZMU) IAW IAI B777-300 AMM 23-39-04 OPS CK GOOD.SDR SWAA2026060207582Lamp · inoperativeRH SIDEWALL LT ABOVE EMERGENCY EXIT INOP. REPLACED THE RH EMER EXIT WINDOW LIGHT LAMP IAW AMM 33-21-00. OPS CHECKED GOOD.SDR CALA2026052816593Bulb · faultedSEAT 43L OVERHEAD LIGHT BULB OVERHEATED AND STARTED TO SMOKE..FA. SHUT IT OFF. MOVED PAX TOO. PERFORMED 15 MINUTE OPS CHECK OF THE READING LIGHTS, SIDEWALL, LIGHTS & OVERHEAD LIGHTS. NO SMOKE WAS DETECTED. ALL LIGHTS ARE WORKING. NO FURTHER ACTION REQUIREDSDR VNAA2026052018201Ballast · unserviceableBURNING ODOR COMING FROM OVERHEAD BIN VENT 1-3A. PERFORMED ABNORMAL SMELL IN CABIN INSPECTION IAW FIM 21-22-00-810-806. SIDEWALL LIGHTS OVER SEATS 2 AND 3 ARE OUT AND WITH RECERT FAN OFF SMELL DECREASED SIGNIFICANTLY. REMOVED AND REPLACED BOTH BALLAST OVER SESDR DALA2026051903076Light · failedWE HAD A LOT OF WATER COME OUT OF GASPERS AT 16DF. PAX REPORTED SPARK FROM OVERHEAD LIGHT. NOW THAT LIGHT IS OUT. INSPECTED THE OVERHEAD PANEL AT 16DEF NOT FAULTS DETECTED PER AMM 33-20, ACFT OK FOR SERVICE. (LP: 8880930). AIRCRAFT WAS GROUNDEDSDR CALA2026051416226Light · inoperativeRT OVERWING EMERGENCY DOOR WINDOW LIGHT INOP REMOVED AND REPLACED RH OVERWING EMERGENCY EXIT DOOR WINDOW LIGHT IN REF TO AMM 33-21-00-960-806. OPS CHECK GOODSDR CALA2026051216189Light · faultedCENTER AND FORWARD HALO LIGHTS IN CABIN DO NOT TURN OFF WHEN TU RNED OFF. ELECTRC SMELL REPORTED R&R CELING LIGHT ABOVE LEFT-HAND EXIT DOOR. OPS CHECK GOOD. IRW AMM 33-22-00/20.PARTS USED: 29-3322-3-0031, QTY :1SDR IPXA2026051102957Bulb · burned outLAV AUXILIARY LIGHT INOP. RELAMPED LAV AUXILIARY LIGHT REF AMM 33-51-00, OPS CHECK GOOD.SDR AALA202605061264Bulb · burned outAIRCRAFT WAS GROUNDED: ELECTRICAL SMOKE SMELL DURING FLIGHT AT FL340 ABOUT 3-5 MINS DURATION. THEN COMPLETELY DISSIPATED. SMELL CAME FROM AREA OF 2F-1RLAV AND THERE WAS EXCESSIVE "FAN" NOISE DURING THE EVENT WHICH ALSO WENT AWAY WHEN THE SMELL DID. MAINTENANCESDR DALA2026050502843Light · burned outFA SMELLED FAINT ELECTRIC BURING SMELL NEAR 24+25 DEF IN CRUISE. SMELL DISSAPATED AS WE CONTINUED. FOUND OVERHEAD LIGHT ABOVE ROWS 24+25 PARTIALLY BURNED OUT. REMOVED AND REPLACED LED ASSY PER B737 AMM 33-22. (LOG 7603676 - AIRCRAFT WAS GROUNDED).SDR SWAA2026043093126Light · faultedWALL LIGHT AT 6F IS FLASHING ON AND OFF. OK TO CONTINUE PER MEL 33-2-04; SP1B. REMOVED AND REPLACED IAW AMM 33-21-00-960-804-NG.SDR CALA2026042715726Battery · malfunctionedLLAR BACKUP LIGHTING FOUND INOPERATION REF HAECO NR NO.9455659,SDR A6WA202604218886Ballast · failedFA REPORTED HOT ELECTRICAL SMELL DURING AIRCRAFT WALK THROUGH POST FLIGHT. FIRE DEPARTMENT NOTED WARM SPOTS IN OVERHEAD BINS 3-6 BOTH SIDES AND SOME BROWN SPOTS ON WIRES. ***AIRCRAFT REMOVED FROM SERVICE ***** R&R LIGHT BALLAST OVER ROW 8AB IAW AMM 25-28-01 OSDR AALA202604077998Light · inoperativeDURING TAKEOFF ROLL, WHEN TAKEOFF POWER WAS SET A STRONG ELECTRICAL BURNING SMELL FILLED THE CABIN FLIGHT DECK AND CABIN TEMPERATURE SPIKED JUST BEFORE ROTATION. REMOVED AND REPLACED SIDEWALL LIGHTS ASSEMBLY AT 3A (AALA202604063262), 4A (AALA202604077998), ANSDR AALA202604074876Light · inoperativeDURING TAKEOFF ROLL, WHEN TAKEOFF POWER WAS SET A STRONG ELECTRICAL BURNING SMELL FILLED THE CABIN FLIGHT DECK AND CABIN TEMPERATURE SPIKED JUST BEFORE ROTATION. REMOVED AND REPLACED SIDEWALL LIGHTS ASSEMBLY AT 3A (AALA202604063262), 4A (AALA202604077998), ANSDR AALA202604073262Light · inoperativeDURING TAKEOFF ROLL, WHEN TAKEOFF POWER WAS SET A STRONG ELECTRICAL BURNING SMELL FILLED THE CABIN FLIGHT DECK AND CABIN TEMPERATURE SPIKED JUST BEFORE ROTATION. REMOVED AND REPLACED SIDEWALL LIGHTS ASSEMBLY AT 3A (AALA202604063262), 4A (AALA202604077998), ANSDR IPXA2026032784468Ballast · inoperativeALL LIGHTS IN THE LAVATORY FOUND TO BE INOPERATIVE, NOT JUST THE CEILING LIGHT. BALLAST CONNECTION RESET AND LAMPS RESET C/OUT, FOUND OPS NORMAL.SDR SWAA2026032582825Ballast · overtempPLASTIC BURNING SMELL IN AFT GALLEY. PERFORMED CONDITIONAL INSPECTION 05-51-56. FOUND AFT ENTRY LIGHT BALLAST OVERHEATED. REMOVED AND REPLACED BALLAST AND LAMPS PER AMM 33-29-00SDR SWAA2026032583093Ballast · overtempPLASTIC BURNING ODOR IN AFT GALLEY. PERFORMED CONDITIONAL INSPECTION 05-51-56. FOUND AFT ENTRY LIGHT BALLAST OVERHEATED. REMOVED AND REPLACED BALLAST AND LAMPS PER AMM 33-29-00SDR SCNA20260325137Light · no discrepancyR1 LAVATORY EMERGENCY EXIT LIGHT INOPERATIVE. PERFORMED OPS CHECK OF LAV CALL LIGHT REF. AMM 33-20-00, NO DEFECTS NOTED. OK FOR SERVICE.SDR AALA202603182527Light · burned outAIRCRAFT WAS GROUNDED: 4L LAV AS STRONG ODOR OF SMOKE, NO SMOKE PRESENT, TOILET WAS BLOCKED/PAPER REMOVED AND H20 POURED INTO TRASH BIN NO INDICATION IN COCKPIT. MAINTENANCE FOUND LAV MIRROR LIGHT PARTIALLY MELTED AND BURNED. REPLACED 4L LAV MIRROR LIGHT ASSY.
Back to JASC 3320