SDR AALA20130518007Ballast · failedF/A REPORTED ELECTRICAL ODOR NEAR AFT GALLEY. EMERGENCY DECLARED, AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. FOUND AFT OVERHEAD GALLEY LIGHT BALLAST WITH STRONG ELECTRICAL ODOR. REPLACED LIGHT CONTROL RELAY AND BALLAST ASSEMBLY FOR AFT GALLEY SDR ASOA2013052203642Light · shortedCLIMBING THRU 15K, BOTH THE F/O AND CAPT SMELLED HOT ELECTRICAL/ BURNING PLASTIC ODOR. DIVERTED, ONE OF THE GALLEY OVERHEAD LIGHTS HAD A SHORTED, CAUSING THE ODOR AS NOTED. R & R LIGHT ASSY IAW AMM 33-26-01. OPS CHECKED GOOD.SDR UALA2013051603412Light · unsecureFLOOR LIGHT AT EDGE OF CARPET BY SECURITY GATE IS LIFTING. SECURED LIGHT.SDR WX0A2013051571580Ballast · malfunctionedSMOKE IN THE CABIN NEAR ROW 20 A-C. RECIRC FAN CIRCUIT BREAKER WAS PULLED. REMOVED & REPLACED UPPER SIDEWALL LIGHT BALLAST & RE-SECURED RECIRC FAN CIRCUIT BREAKER.SDR CA130510006Light · corroded(CAN) WHILE PERFORMING AN INTERNAL GENERAL VISUAL INSPECTION OF THE PASSENGER DOOR FOR ZONAL TASK 823, THE AME FOUND ALL 4 OF THE AIRSTAIR LIGHT ASSEMBLIES WITH SIGNIFICANT CORROSION ON THE BACKSHELL. WHEN REMOVED FOR A CLOSER INSPECTION, THE CORROSION FOUND SDR UALA2013050903244Light · inoperativeBUSINESS CLASS CROSS AISLE LIGHT INOP IN FULL OK IN DIM. RELAMPED OKAY.SDR ASOA20130504033Ballast · faultyTHE CREW REPORTED A BURNING SMELL IN THE GALLEY AREA DURING FLIGHT. MX INSPECTED AND REPLACED THE NR 1 CEILING LIGHT BALLAST. OPS CHECKS WERE GOOD.SDR SWIA201333365Ballast · faultyLIGHT ABOVE SINK IN LAV IS DIM AND HAS A SLIGHT ELECTRICAL SMELL. (FLT 6234) REPLACED LAVATORY LIGHT BALLAST.SDR UALA2013050203088Ballast · inoperativeSIDE WALL LIGHTS AT 8F AND 40A INOP. REPLACED SIDEWALL BALLAST AT 8F AND 40A, OPS CHECK GOOD.SDR CA130508009Ballast · overheated(CAN) ELECTRICAL BURNING ODOR REPORTED IN THE CABIN. MAINTENANCE R & R BURNED BALLAST PS63 ON RT AFT SIDE OF CEILING. OPS CHECKED GOOD REF AMM 33-21-03.SDR UALA2013050203092Light · inoperativeUPPER DECK GALLEY FWD CEILING LIGHT INOP. RELAMPED, OPS CHECKED OKAY.SDR UALA2013042402842Light · inoperativeLAVATORY LIGHTS INOP AT DOOR-1L FWD-CAB LAV. LIGHT INOP IN FWD LAV. RELAMPED INCANDESCENT. CHECKS OK.SDR UALA2013042302807Module · faultyUNABLE TO DIM CABIN CEILING LIGHTS BACK 1-2 BUSINESS +ECON PLUS. REPLACED NR 2 ZMU.SDR JJBA20130418009Light · smokeSHORTLY AFTER PUSH BACK FROM THE GATE, CREW NOTICED SMOKE COMING FROM THE NR 2 STEP LIGHT ON THE MAIN CABIN DOOR. MX R & R THE LIGHT COVER. ALL OPS CHECKS WERE SATISFACTORY.SDR CA130418003Ballast · overheated(CAN) CLIMBING THROUGH 12000, THE F/A REPORTED AN ELECTRICAL ODOR AROUND ROW 17. ACFT RETURNED TO DEPARTURE POINT. MAINTENANCE ACTION DETERMINED THAT THE SIDEWALL LIGHTING BALLAST AT ROW 18 TO BE AT FAULT. THE BALLAST WAS THEN REMOVED, THE CONNECTORS WERE STSDR UALA2013041602609Light · overheatedFLIGHT ATTENDANT REPORTED VISIBLE SMOKE AND SMOKE ODOR COMING FROM AFT CABIN. FOUND HEAT SIGNATURE COMING FROM LIGHT ABOVE TISSUE HOLDER IN AFT AFT LAVATORY. REPLACED AFT LAVATORY LIGHT ASSY FOUND OVERHEATING.SDR UALA2013041502564Ballast · inoperativeAFT LAVATORY FLUORESCENT LIGHT INOPERATIVE. REPLACED BALLAST. AFT LAVATORY LIGHTS OPERATE NORMALLY.SDR JJBA20130411003Cover · burnedCREW REPORTED A STRONG ODOR OF BURNING RUBBER OR PLASTIC IN FLIGHT DECK. MX R & R THE TOP AIR STAIR DOOR LIGHT COVER.SDR UALA2013040902394Lens · missingDOOR 2L THRESHOLD LIGHT IS MISSING THE LENS COVER. LAMP REMOVED REF IPC 33-20-51-002 NEED ITEM 238. P/N 25-1116-1. COMPLIED WITH MEL. INF- :170-4384 IS THE BEZEL ASSY. REPAIR- :INSTALLED LAMP AND BEZEL ASSY, OPS CHECKED NORMAL.SDR SWAA2013041014632Terminal · damagedSTRONG ELECTRICAL SMELL IN FWD GALLEY. RE-TERMINATED FWD GALLEY WORK LIGHT TERMINAL IAW WDM.SDR SIMA20130402003Module · defectiveON FLIGHT 3838 THE CREW REPORTED A BURNING SMELL IN THE MAIN CABIN AROUND ROW 'S 6 AND 7. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE DIMMING MODULE PS 76 IAW CRJ 700 AMM 33-21-03. THE OPERATIONAL TESTS WERE GOOD. NO FURTHER SMELL NOTEDSDR HNAA2013040300198Socket · damagedSMOKE NOTED FROM OVERHEAD LIGHTS AT ROW 1AC. INSPECTED AND FOUND DAMAGE SOCKET. OVERHEAD LIGHT CIRCUIT BREAKERS S1, S2 AND R2 ARE DEACTIVATED. R & R BALLAST AND LIGHT SOCKET. REACTIVATED OVERHEAD LIGHTS. OPS CHECKED GOOD.SDR UALA2013040402232Ballast · inoperativeWINDOW LIGHT AT ROW 24 LEFT INOPERATIVE. REPLACED BALLAST AT ROW 24 LEFT PER MM, OK FOR SERVICE.SDR UALA2013040302173Ballast · faultyHOT WATER BUTTON IN F-C GALLEY WHEN DEPRESSED CAUSES F-C GALLEY LIGHTS TO DIM. REPLACED BALLAST 9019ML1 REF WDM 25-31-01. INSPECTED WIRING AND NO ISSUES FOUND. GALLEY LIGHTS WORKING NORMALLY.SDR UALA2013040102086Socket · arcedF/A'S REPORT ODD ELECTRICAL TYPE ODOR IN AFT LAV. CONFIRMED DOME LIGHT IS OPERATIVE. MIRROR LIGHT BULBS REMOVED. FOUND LIGHT BULB SOCKET ARCHING. NOT TIME TO CHANGE. REMOVED BULBS.SDR UALA2013032902030Controller · faultedAFTER ACFT POWER UP, CHECKED "E" ZONE BETWEEN DOOR 4 AND 5, CEILING AND SIDEWALL LIGHTS KEEPS ON, CANNOT TURN OFF. RESET E & E BAY P414 E-ZONE CEILING & SIDEWALL LIGHT CIRCUIT BREAKER TWICE, CEILING & SIDEWALL LIGHTS BEEN TURN OFF. E-ZONE SOME SEATS READING SDR CHQA20130324090Light · defectiveCREW REPORTED THAT DURING LANDING THERE WAS AN ELECTRICAL SMELL COMING FROM THE LIGHTING BALLAST AT ROWS 5 AND 6. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE BULBS AT ROWS 5 AND 6. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTESDR UALA2013032501863Socket · burnedELECT BURNING ODOR FROM DR 4 AFT GALLEY AREA. FLIGHT ATTENDANT DESELECTED MASTER POWER SWITCH AND ODOR CLEARED. FOUND ECLASS GALLEY POSITION 6, GALLEY LIGHT FLUORESCENT LIGHT SOCKET MELT. NEED TO REPLACE LIGHT GALLEY CEILING ASSY. PULL CB AND SECURE FOR GSDR VNAA2013032300019Unknown · malfunctionedCREW RECEIVED SMOKE TOILET MESSAGE WITH VISIBLE SMOKE IN CABIN AT FL210 IN DESCENT. CREW LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE FOLLOWING: PSU PCB (PASSENGER SERVICE UNIT PRINTED CIRCUIT BOARD) ON ROW 11 D/F (BURNTSDR SWIA201333002Light · burnedFIRST CLASS CLOSET LIGHT FIXTURE IS BURNT WITH BROKEN WIRES. (SERVICE) REMOVED AND REPLACED WARDROBE LIGHTING FIXTURE IAW AMM. P/N: CDEL1006-505SDR QXEA2013031000579Lamp · inoperativeREAR EXIT SIGNS CALL LIGHT IS INOPERATIVE. REPLACED LAMP. LIGHT CHECKED GOOD. RETURNED TO SERVICE.SDR CA130308010Sign · overheated(CAN) ABOUT ONE MINUTE AFTER TAKEOFF THE CREW RECEIVED A LAVATORY SMOKE INDICATION IN THE COCKPIT. THERE WAS ALSO A ODOR REPORTED IN THE LAVATORY BUT NO VISIBLE SMOKE. THE SMOKE INDICATION WENT OFF AFTER ABOUT 3 MINUTES. THE ACFT RETURNED TO THE DEPARTURE AIRSDR USAA2013030700001Light · defectiveTHE 27H READING LIGHT WAS HOT AND APPEARED TO BE SMOKING. MAINTENANCE REPLACED 27H READING LAMP OPERATIONAL CHECK IS SATISFACTORY.SDR VNAA2013022800018Power Unit · faultyCREW REPORTED THE LAVATORY LIGHT INOP WITH A STRONG ELECTRICAL SMELL. MAINTENANCE TROUBLESHOT, REMOVED, REPLACED, AND OPERATIONAL CHECKED THE LAVATORY POWER UNIT / DIMMER USING AIRCRAFT MAINTENANCE MANUALS. AIRCRAFT WAS RELEASED FOR SERVICE.SDR ASOA20130221015Control Module · odorELECTRICAL BURNING ODOR REPORTED COMING FROM FRONT OF CABIN. R & R THE PASSENGER CABIN LIGHTS CONTROL MODULE ASSY WITH OPS CHECK SUCCESSFUL. ACFT WAS APRROVED FOR RETURN TO SERVICE.SDR UALA2013022001017Ballast · failedDURING APPROACH, AN ELECTRICAL ODOR NEAR 1L AND LAV WAS DETECTED. FOUND SOURCE OF ODOR TO BE BALLAST AT CEILING LIGHT ABOVE SEAT 1A, FOUND FLUORESCENT TUBES AT 1A LOOSE AND INTERMITTENT, REMOVED TUBES FROM 1A & 2A CEILING LIGHTS, REMOVED BALLAST AT 1A DISCOSDR SWIA201332841Ballast · odorELECTRICAL BURNT SMELL COMING FROM LAV. (FLT 5631) REPLACED LAV LIGHT BALLAST, OLD BALLAST HAD SMELL.SDR REXA2013021900359Light · inoperativeTHREE COLORED INDICATOR LIGHTS ON BACK OF MID CABIN EXIT SIGN DID NOT ILLUMINATE. RELAMPED AIRCRAFT FACING LIGHTED CEILING EXIT SIGN (FLIGHT ATTENDANT CALL LIGHTS 3 ) IAW AMM 33-51-14.SDR CA130219003Light · overheated(CAN) DURING THE CLIMB THE CREW RECEIVED A LAVATORY SMOKE WARNING INDICATION. THE F/A NOTICED A LEATHER ODOR IN THE LAVATORY BUT NO EVIDENCE OF SMOKE OR FIRE. THE ACFT RETURNED TO THE DEPARTURE AIRPORT. ALL WIRING IN THE VICINITY OF THE LAVATORY WAS CHECKED SDR REXA2013021700302Charger · inoperativeFLOOR TRACK LIGHTING 2-5 INOPERABLE. REPLACED NR 2 CHARGER IAW CRJ 200 AMM 33-51-05.SDR HNAA2013021500059Socket · burnedSTRONG ELECTRICAL ODOR COMING FROM REAR OF CABIN OVERHEAD LIGHT AT ROW 7AC SOCKET BURNED. DE-ACTIVATED CABIN INTERIOR NORMAL LIGHT SYS IAW SPECIAL PRECEDURE 33.1. FOUND O/H LIGHT SOCKET BURNED AT ROW 7AC. REMOVED AND REPLACED LIGHT SOCKET AND BALLAST AT ROW SDR REXA2013021200290Light · inoperativeAFT BLUE CALL LIGHT ON CENTER CABIN EMERGENCY EXIT SIGN IS INOPERABLE. REMOVED AND REPLACED BULB PN 6839 AS REQUIRED. OPS CHECK GOOD.SDR CA130311019Socket · sparks(CAN) ELECTRICAL ODOR IN REAR GALLEY. ENGINEERS DISCOVERED THAT AN OVERHEAD CABIN SIDE WALL BULB, 21B WAS BEGINNING TO SPARK AND SMOULDER, PRODUCING A PLASTIC BURNING SMELL, SIMILAR TO THE SAME ODOR EXPERIENCED BEFORE. BULB REMOVED AND SURROUNDING AREA EXAMISDR CA130212024Light · corroded(CAN) F/A NOTICED SMOKE COMING FROM AIRSTAIR DOOR, UNABLE TO FIND CONCLUSIVE CAUSE OF THE ARCING IN THE AIR STAIR. FOUND THE WATER DAMAGE ON ALL 4 LED LIGHT ASSY, PN 2LA285028-01. REPLACED WITH PRE-EO DH8-5210-A08052, AIR STAIR LIGHT ASSY, PN 10-1180-1) DUSDR IPXA13177001Lamp · inoperativeINSPECTION TYPE :ASE, LAVATORY AUX LIGHT INOPERATIVE. REPLACED LAMP & TESTED GOOD IAW AMM 33-50-00.SDR YENA20130204030Socket · defectiveFLT 1740 SJU-JAX, CREW DECLARED EMERGENCY AND AIRCRAFT DIVERTED TO PLS DUE PERCEPTABLE SMOKE FROM BEHIND READING LIGHT ROW 24DEF. FLIGHT ATTENDANT SAW AND SMELLED SMOKE. FLIGHT ATTENDANT TURNED OFF READING LIGHT ON FWD CIDS PANEL AND VISIBLE SMOKE DISSIPATEDSDR CA130214009Ballast · overheated(CAN) JUST PRIOR TO LINING UP TO PARK AT THE GATE, SMELLED AN ELECTRICAL BURNING ODOR IN COCKPIT. THE F/A FORWARD SMELLED IT FIRST. NO VISUAL INDICATIONS AFTER SHUTDOWN ODOR QUICKLY STOPPED. FOUND BALLAST HOT AND SMELLING LIKE ELECTRICAL BURNING.SDR SWIA201332698Ballast · defectiveELECTRICAL BURNING SMELL IN THE COCKPIT. AFTER SHUT DOWN ODOR QUICKLY STOPPED. (FLT 4487) REPLACED SIDEWALL AND CEILING LIGHT BALLAST AT ROW 1C/D.SDR UALA2013013000565Ballast · odorFLT ATTENDANTS REPORTED ELECTRICAL ODOR ON DESCENT. DISSIPATED AFTER 5-10 MINUTES NO SMOKE OR FIRE. NO VISIBLE SMOKE OR FUMES. PER TSM 24-00-00-810-823A FOUND SIDEWALL LIGHT AT ROW 26F INOPERATIVE. REMOVED LAMP AND BALLAST HAD BURNED ODOR. REPLACED BALLASDR WX0A071501Ballast · failedFLIGHT ATTENDANT NOTICED SMOKE BY SEAT 19A. PASSENGER STATED SHE NOTICED SMOKE AFTER AN OVERHEAD SIDWALL LIGHT WENT OUT. AFTER TROUBLESHOOTING SYSTEM A BAD BALLAST AT ROW 19 LEFT FOR THE LOWER SIDEWALL LIGHTS. REMOVED AND REPLACED THE BALLAST SYSTEM. OPERA
Back to JASC 3320