SDR HNAA2013012800022Socket · burnedSTRONG ELECTRICAL ODOR COMING FROM AROUND ROW 6. INSPECTED AND FOUND DAMAGED OVERHEAD LIGHT SOCKET AT ROW 8 AND 9DF. R & R SOCKET ASSY AT ROW 8 AND 9DF. OPS CHECKED GOOD.Jan 28, 2013 · N333EN · Dhav DHC8311SDR UALA2013012500452Socket · burnedSMOKE IN GALLEY, RETURNED TO FIELD. ISOLATED SOURCE OF SMOKE, FOUND TWO LAMP SOCKETS BURNED, DEACTIVATED CIRCUIT BREAKER C023 PULLED. REPLACED LIGHT ASSY, SYSTEM CHECKS NORMAL.Jan 25, 2013 · N177UA · Boeing 747422SDR CA130121003Ballast · overheated(CAN) IN CRUISE, CREW REPORTED A RUBBER ORDER AT SEAT 29K. THE NEON BALLAST UNIT WAS FOUND WITH BURNED SPOTS AND ODOR. BALLAST WAS REPLACED IAW AMM AND TESTED SERVICEABLE.Jan 19, 2013 · Airbus A330342SDR SIMA20130117003Ballast · defectiveFOR FLIGHT 4128 THE FLIGHT ATTENDANT REPORTED AFTER LANDING SHE NOTICED AN ELECTRICAL ODOR EMITTING FROM THE TOILET SECTION (ELECTRICAL BURNING SMELL). THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED GENERAL VISUAL INSPECTION OF LAV LIGHTS /BALLAST AND LAV Jan 17, 2013 · N639AE · Emb EMB145LRSDR CA130201002Ballast · odor(CAN) DURING FLIGHT, ODOR OF ELECTRICAL BURNING WAS DETECTED IN ROW 8 OF THE CABIN NEAR THE SIDE WALL LIGHTS. THE LT AND RT SIDE WALL LIGHT FIXTURE ASSEMBLIES WERE REPLACED AND SYSTEM CHECKED SERVICEABLE. NO MORE ELECTRICAL BURNING ODOR IN THE CABIN.Jan 16, 2013 · Dhav DHC8102SDR SWIA201332563Light · burnedSMOKE REPORTED IN CABIN. (FLT 5363) FOUND OVERHEAD LIGHT FIXTURE ASSEMBLY BURNED AT ONE END NEAR ROW 9 B/C. REPLACED LIGHT ASSEMBLY.Jan 16, 2013 · N585SW · Emb EMB120ERSDR N6WA2013011607Ballast · burnedELECTRICAL ODOR, & BURNING PLASTIC ODOR OBSERVED IN AFT CABIN. REPLACED AFT BALLAST IAW REO 670-33-25-001.Jan 16, 2013 · N168GJ · Cndair CL6002C10SDR UALA2013011600267Module · faultyCABIN SYSTEMS CONTROL PANEL AT 1L UNABLE TO CONTROL TEMP OR LIGHTS. CSCP L1 GIVING INVALID DATA L2 CACP WORKING & CONTROLLING THE LIGHT NORMAL. REPLACED ZMU1, ALL LIGHTS CONTROLLABLE.Jan 15, 2013 · N217UA · Boeing 777222SDR SIMA20130115008Light · defectiveON FLIGHT 3273 THE CREW REPORTED THE READING LIGHT AT 8C SMELLED HOT. REMOVED AND REPLACED THE READING LIGHT LAMP AT SEAT 8C IAW EMB 145 AMM 33-25-02. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.Jan 15, 2013 · N684JW · Emb EMB145LRSDR UALA2013011600256Cids · malfunctionedCABIN LIGHTS FLASHING THROUGHOUT BACK HALF OF AIRCRAFT. INSTALLED NEW CIDS DIRECTOR, OPS CHECKED NORMAL.Jan 14, 2013 · N452UA · Airbus A320232SDR HNAA2013011400005Ballast · smokeSMOKE NOTICED AROUND ROW 1DF OVERHEAD LIGHT ASSY. REPLACED BALLAST.Jan 14, 2013 · N808EX · Dhav DHC8102SDR UALA2013011400218Ballast · failedDUE TO REPORTED ELECRICAL ODOR IN CABIN, SMOKE ODOR IN CABIN. FLIGHT ATTENDANT TURNED OFF SIDEWALL LIGHTS AND ODOR DISSIPATED AND IS NO LONGER PRESENT. REPLACED LIGHT BALLAST AT ROW 14 D, E, F PER AMM. FOUND EVIDENCE OF ARCING, BURNED TERMINAL ENDS AND SOMJan 12, 2013 · N589UA · Boeing 757222SDR UALA2013011100187Light · inoperativeCEILING LIGHTS INOPERATIVE. NO CIDS 1 DATA INTERMITTENT. PFR SHOWED CIDS 1 AS INTERMITTANT. CIDS 1 WILL NOT GO INTO BITE. REPLACED CIDS 1 CONTROLLER. BITE TEST IS GOOD. ALL INDICATIONS NOW NORMAL. REPLACED ACARS MU PER AMM, OPS CHECKED OKAY.Jan 10, 2013 · N405UA · Airbus A320232SDR UALA2013011100182Unknown · unknownALL CABIN OVERHEAD LIGHTS ARE FLICKERING ON AND OFF. PERFORMED A VISUAL INSPECTION OF NR 2 GEN FEEDER FIREWALL DISCONNECT. NO DEFECTS FOUND. ACP DEU A AND CIDS TEST NORMAL.Jan 10, 2013 · N436UA · Airbus A320232SDR ASOA20130104001Ballast · faultyBURNING ODOR REPORTED IN CABIN. MX INSPECTED CABIN AND FOUND SIDEWALL LIGHT BALLAST AT 14A TO BE THE CAUSE. MX R & R BALLAST, OPS CHECKED SUCCESSFUL AND NO FURTHER BURNING ODORS. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jan 4, 2013 · N21144 · Emb EMB145XRSDR SIMA20130103005Ballast · unserviceableON FLIGHT 3435 THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN THE GALLEY, THE GALLEY LIGHT WAS HOT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE GALLEY LIGHT BALLASTS AND LIGHT BULBS IAW AMM 33-29-05. THE OPERATIONAL CHECK WAS GOODJan 3, 2013 · N848AE · Emb EMB135KLSDR REXA2013010100053Light · burned outON FLIGHT 4378 (GSP TO DTW) AN AIR RETURN WAS PERFORMED DUE TO SMOKE TOILET MESSAGE ON CLIMBOUT OF GSP. AN EMERGENCY WAS DECLARED AFTER FOLLOWING CFR AND THE AIRCRAFT LANDED SAFELY. INSPECTED LAVATORY AND FOUND BURNED OUT BULBS IN RETURN TO SEAT SIGN. REMOVJan 1, 2013 · N8736A · Cndair CL6002B19SDR HNAA2012122801134Socket · damagedCENTER ISLE LIGHT AT 1DF STARTS TO SMOKE. CIRCUIT BREAKERS S1, S2 AND R2 WERE PULLED AND COLLARED.Dec 28, 2012 · N809EX · Dhav DHC8102SDR CA130103006Ballast · failed(CAN) BURNING ODOR EMANATING FROM A3 LAVATORY, L2 BAR AREA. GALLEY POWER SHUTDOWN, VIDEO SCREENS POWER SHUTDOWN IAW ADVISE FROM MOC. MAINTENANCE TRAVELING ON THE FLIGHT PERFORMED AN INSPECTION RECOMMENDED SHUTTING DOWN LAVATORY LIGHTING CIRCUIT. FOUND AFT GDec 25, 2012 · Boeing 767375SDR A6WA201212314J057Light · looseSTRONG ELECTRICAL BURNING OR MELTING PLASTIC ODOR IN COCKPIT IMMEDIATELY AFTER LANDING GOES AWAY AFTER 5 MINUTES. INSPECTED AND FOUND TOP GALLEY SERVICE LIGHT BULB LOOSE IN CARRIER CAUSING INTERMITTENT SHORT. REMOVED BULB, OK TO CONTINUE ON MEL 33-21-01 REF Dec 24, 2012 · N453AW · Cndair CL6002B19SDR CA130107005Socket · failed(CAN) RT AFTER DEPARTURE THE F/A ADVISED THE CREW THAT SMOKE WAS PRESENT IN THE CABIN ALONG WITH AN ELECTRICAL SMELL. ACFT RETURNED TO DEPARTURE AIRPORT. EMERGENCY WAS DECLARED. F/A TURNED OFF CABIN LIGHTS AND ODOR STARTED TO CLEAR. CREW REPORTED WHEN MAINTDec 20, 2012 · Cndair CL6002B19SDR UALA2012122107329Light · missingOUTSIDE WALL OF LAV 'D', FWD AFT LAV, CALL LIGHT ASSY IS MISSING. REF 23-73-09-55 ITM 40. PCN 565-1476. REPLACED LAV CALL LIGHT, LAV 'D' & FWD AFT LAV PER AMM.Dec 20, 2012 · N831UA · Airbus A319131SDR HALA2014012200014Lamp · inoperativeFWD ENTRY DOOR LIGHT IS OUT. REPLACED LAMP , OPS CHECKED NORMAL.Dec 19, 2012 · N597HA · Boeing 767332SDR DALA12016520920Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE OVERHEAD EMERGENCY PATHWAY LIGHTING AT ROWS 12-15 AND ROWS 29-31 WERE INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Dec 15, 2012 · N920DL · Doug MD88SDR UALA2012121407249Light · inoperativeFOUND ON NR 2 SERVICE LAV SMOKE CHECK, CALL LIGHT FOR LAV F DOES NOT ILLUMINATE (591RH6) ASM23-73-18. ALSO CIDS CLASS 3 FAULTS "PAX CALL LAMP LAV F" FAULTED. SWAPPED LAMPS WITH KNOWN GOOD LAMPS, NO HELP. FOUND WIRES BEHIND LIGHT ASSY NOT CONNECTED. SECUREDDec 14, 2012 · N463UA · Airbus A320232SDR 2012FA0000824Power Supply · burnedPASSENGER SMELLED AND SAW A SMALL AMOUNT OF SMOKE COMING FROM THE LT FORWARD FACING SEAT WINDOW FLUORESCENT LIGHT. FOUND FLUORESCENT LIGHT POWER SUPPLY ASSY MELTED AND BURNED.Dec 10, 2012 · N11SN · Beech C90SDR CALA2012121700860Ballast · shortedF/A REPORTED AN ELECTRICAL BURNING ODOR AROUND L2 DOOR,M DID NOT SEE SMOKE. TROUBLESHOT IAW 05-51-58-910-801C1. FOUND FLOOR LIGHT BULBS IN MID LAVATORY BLACK. TRACED ODOR TO BALLAST FOR FLOOR LIGHTS. REMOVED WIRE NR 6 FROM DOOR LATCH SWITCH STOWED.Dec 7, 2012 · N17128 · Boeing 757224SDR REXA2012120701752Cover · unknownF/A NO SMOKING/FASTEN SEAT BELT SIGN IN GALLY NEEDS COVER REPLACED. 2LA007353-50. OPS CHECK OK. REMOVED AND REPLACED F/A GALLEY NO SMOKING LIGHT IAW CRJ200 AMM 33-24-00. THIS CLOSES OUT DM 76112.Dec 7, 2012 · N829AY · Cndair CL6002B19SDR HNAA2012120301086Socket · failedSEAT 2DF HAS SMOKE COMING FROM OVERHEAD LIGHT. R & R LAMP HOLDER AT ROW 2DF IAW AMM 33-20-00 AND LIGHT BALLAST IAW AMM 33-21-02. OPS CHECKED GOOD.Dec 3, 2012 · N330EN · Dhav DHC8311SDR SWIA201232272Power Unit · failedSEATS 13 A/B AISLE LIGHTS FLICKERING. (SERVICE) REPLACED POWER UNIT DIMMER AND FLUORESCENT LIGHT BULBS.Dec 1, 2012 · N917SW · Cndair CL6002B19SDR VNAA2012120100001Power Unit · defectiveCREW REPORTED LIGHT ABOVE BIN AT SEATS 10A/C INOPERATIVE AND SMELL OF ELECTRICAL ODOR. MAINTENANCE INSPECTED, REMOVED AND REPLACED CEILING LIGHT POWER UNIT / DIMMER AT SEATS 10A/C AND PERFORMED CHECKS USING AIRCRAFT MAINTENANCE MANUALS. AIRCRAFT RELEASED FORDec 1, 2012 · N245PS · Cndair CL6002B19SDR IPXA2176368Lamp · inoperativeLAVATORY MIRROR LIGHT OUT. LAMPED AND OPS CHECKED GOOD IAW AMM 33-51-21-0401.Nov 30, 2012 · N160UP · Airbus A300F4622RSDR UALA2012112806808Ballast · faultyELECTRICAL ODOR UPPER DECK STAIRWAY LIGHT. CHECKED FOUND THE ODOR IS FROM THE LIGHT L2976, REMOVED THE LIGHT L2976 AND DEACTIVATED BALLAST M7564, SO THE LIGHT L2977 IS INOP ALSO. PLZ REF TO WDM 33-29-21. DF DUE TIME. FOUND ONE OF THE LAMP SOCKETS BURNT AND Nov 28, 2012 · N171UA · Boeing 747422SDR UALA2012120406968Socket · defectiveELECTRICAL ODOR UPPER DECK STAIRWAY LIGHT. CHECKED FOUND THE ODOR IS FROM THE LIGHT L2976, REMOVED THE LIGHT L2976 AND DEACTIVATED BALLAST M7564, SO THE LIGHT L2977 IS INOP. FOUND ONE OF THE LAMP SOCKETS BURNT AND CRACKED.Nov 28, 2012 · N171UA · Boeing 747422SDR UALA2012112806829Ballast · defectiveON CM CHECK FOUND SEAT 17JK SIDEWALL WASH LIGHT REAR LAMP HOLDER BURNT OFF. TUBE REMOVED. NO SPARE SOCKET IAW MM. BALLAST SUPPLY PWR PLUG DISCONNECTED AND PROTECTED, NO PWR TO BALLAST AND TUBES, TWO TUBES INVOLVED. REPLACED LAMP HOLDER. REINSTALLED LAMP, Nov 27, 2012 · N179UA · Boeing 747422SDR AALA20121126018Ballast · failedORD - CREW REPORTED LEFT OVERHEAD LIGHT BALLAST BEHIND ROW 8AB FAILED WITH FUMES AND ELECTRICAL SMELL. PER EMERGENCY PROCEDURE, PULLED CIRCUIT BREAKERS L6, J7, L19, L20, L21 AND F6. EMERGENCY DECLARED FLIGHT RETURNED ORD LANDED WITHOUT INCIDENT. AIRCRAFT RENov 26, 2012 · N581AA · Doug DC982SDR SWIA201232247Ballast · faultyF/AS REPORT STRONG BURNING SMELL IN OVERHEAD BIN 13-15. (FLT 4831) RESIDUAL SMOKE SMELL FROM REPLACED 13A/B CEILING LIGHT BALLAST.Nov 25, 2012 · N692CA · Cndair CL6002D24SDR DJFA20121118001Ballast · failedCREW REPORTED STRONG ODOR OF HOT ELECTRICAL OR RUBBER IN CABIN. MX FOUND BALLAST FOR PASSENGER LIGHTING BAD.Nov 20, 2012 · N910FL · Emb EMB135BJSDR SIMA20121119002Light · inoperativeON FLIGHT 3225 AFTER LANDING THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL BURNING SMELL IN THE CABIN. THE CREW NOTICED A FAINT SMELL IN THE COCKPIT THEN DISSIPATED. THE FLIGHT ATTENDNANT SAID THE ODOR LINGERED IN THE CABIN. THE AIRCRAFT WAS REMOVED FROM SERVICNov 19, 2012 · N604AE · Emb EMB145LRSDR HNAA2012111901063Socket · burnedOVERHEAD LIGHTING AT ROW 6AC SMOKING WITH BURNING ODOR. OVERHEAD LIGHTS DEACTIVATED IAW SP 33.1. INSPECTED AND FOUND OVERHEAD LIGHT HOLDER SOCKET BETWEEN 5C-6C BURNED UP. R & R HOLDER SOCKET AND BALLAST FOR OVERHEAD LIGHT AT 5C/6C IAW STANDARD PRACTICE.Nov 19, 2012 · N330EN · Dhav DHC8103SDR CA121116008Socket · burned(CAN) SMOKE FROM 9F SIDEWALL LIGHT. REPLACED LIGHT ASSY .Nov 15, 2012 · Cndair CL6002B19SDR UALA2012111606622Light · faultyCEILING LIGHT ABOVE 8H. RELAMPED, CHECKS OKAY.Nov 15, 2012 · N779UA · Boeing 777222SDR A6WA20121107515Light · odorDEFECT DESCRIPTION - LAV LIGHT INOP, BURNING SMELL NOTED IN LAV NEAR LIGHT. REMOVED AND REPLACED THE LAV LIGHT ASSEMBLY IAW CRJ AMM 33-25-07 OPS CHECK GOOD. NOTE: THE WHOLE ASSEMBLY WAS CHANGED DUE TO HARDWARE ISSUES - THE SMELL WAS THE BALLAST.Nov 7, 2012 · N435AW · Cndair CL6002B19SDR SIMA20121104002Light · inoperativeDURING B INSPECTION FOUND THE FURTHEST AFT CEILING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LAMP IN FURTHEST AFT CEILING EMERGENCY LIGHT IAW EMB AMM TASKS 33-50-08-000-801-A AND 33-50-08-400-801-A. THE OPERNov 4, 2012 · N803AE · Emb EMB135KLSDR SWIA201232123Ballast · malfunctionedBURNING SMELL FROM OVERHEAD BIN ROW 2 A/B SIDE. (FLT 5207) REPLACED LIGHT BALLAST.Nov 3, 2012 · N774SK · Cndair CL6002C10SDR CHQA20121031397Control Module · faultyCREW REPORTED AN ELECTRICAL BURNING ODOR FROM THE FRONT OF THE CABIN DURING FLIGHT. MAINTENANCE REPLACED THE CABIN LIGHTING CONTROL MODULE. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.Oct 31, 2012 · N293SK · Emb EMB145LRSDR SWIA201232095Ballast · inoperativeLAVATORY LIGHT BALLAST BURNED OUT. (FLT 6227) REPLACED BALLAST.Oct 30, 2012 · N919SW · Cndair CL6002B19SDR UALA2012103006252Light · unsecureROW 3B STRIP LIGHT FELL OFF. SECURED STRIP ON SEAT 3B.Oct 30, 2012 · N666UA · Boeing 767322SDR MASA2012102852255Light · inoperativeROW 13 EMERGENCY CALL LIGHT INOP. MX REPLACED BULB.Oct 28, 2012 · N916MJ · Cndair CL6002D24SDR A6WA20121101510Ballast · malfunctionedELECTRICAL ODOR AT OVERHEAD ROW 3-4. INVESTIGATED AND FOUND TO BE SIDEWALL LIGHTING BALLAST AT ROW 3-4 OVER HEAD. SEE 237265/1 FOR MEL.Oct 26, 2012 · N457AW · Cndair CL6002B19
Back to JASC 3320