SDR ASOA20121025086CLight · odorTHE CREW REPORTED SMOKE ODOR IN THE CABIN. MX TIGHTENED LOOSE WIRE ON ROW 8A LIGHT ASSY. OPS CHECKS WERE GOOD.SDR UALA2012101905980Light · faultySMOKE SMELL AROUND SEATS 23-24 ABC. OVERHEAD LIGHTS TURNED OFF AND SMELL DISSIPATED. SAMC TEXT: NEED TO ACP CHECK PER MM. CONSULTED WITH CREW VERBAL INFORM SMELL DISSIPATED WHEN READING LIGHT TURNED OFF. SURROUND AREA CEILING PANEL DROP DOWN AND INSPECTIONSDR HNAA2012101701015Bulb · damagedCABIN OVERHEAD LIGHTS AT ROW 12DF SMOKING. DAMAGED BULB REMOVED AND CABIN OVERHEAD LIGHTNING DEACTIVATED, PULLING CIRCUIT BREAKERS S1, S2 AND R2 ON RT MAIN BUSS. PULLED BULB AND CABIN OVERHEAD LIGHTNING DEACTIVATED. AT NEXT RUN, R & R ASSOCIATED BALLAST, BULSDR A6WA20121011508Ballast · malfunctionedLAV BURNING SMELL NOTICED. REMOVED AND REPLACED BALLAST ASSY AND ALL LAMPS. ALSO REPAIRED GROUND TERM. SYS TEST OK PER AMM 33-25-07. NO SMELL AFTER TEST.SDR A6WA20121011507Power Unit · faultySTRONG BURNING SMELL EMITTING IN REAR OF A/C STRONGEST NEAR LAV. FOUND LAV LIGHT POWER UNIT BURNT. REMOVED AND REPLACED POWER UNIT REF CRJ AMM 33-25-07. OPS CHECKS GOOD AT THIS TIME. STRONG SMELL DISSIPATED.SDR TRBA20121007001Socket · brokenF/A REPORTED A HEAVY ODOR OF ELECTRICAL SMOKE IN THE FORWARD CABIN. ACFT REMOVED FROM SERVICE. INSPECTED AREA AND FOUND THE OVERHEAD CEILING LIGHT SOCKET BROKEN CAUSING A BAD CONNECTION. R & R THE OVERHEAD CEILING LIGHT SOCKET 3 &4 AB IAW MM 33-21-23. ACSDR SWAA2012100808308Light · arcedELECTRICAL SMELL IN AFT GALLEY AREA. REMOVED AND REPLACED AFT GALLEY CEILING LIGHT ASSY PER MM.SDR SIMA20121003006Ballast · defectiveON FLIGHT 4569 THE FLIGHT ATTENDANT REPORTED THAT WHEN THE GALLEY LIGHT IS ON HIGH THERE IS AN ELECTRICAL SMELL IN GALLEY AREA. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE GALLEY AREA LIGHTS BALLAST IAW AMM 33-21-04. THE OPERATIONAL CHECSDR A6WA20121004505Ballast · defectiveSTRONG ELECTRICAL / PLASTIC ODOR ROW 10. REF W/O 191295. REMOVED AND REPLACED PAX SIDEWALL LIGHTS 9, 10 & 11 AND BALLAST FOR EACH. OPS CHECK GOOD. RAN FOR 1 HOUR WITH NO SMELL.SDR ASOA20121001128Light · odorDURING POST FLIGHT INSPECTION, CREW REPORTED A STRONG ELECTRIC BURNING ODOR IN CABIN. FOUND TO BE CEILING LIGHTS 14A-18A. OPENSDR A6WA20121001504Ballast · malfunctionedSTRONG ELECTRICAL SMELL IN LAV. REMOVED AND REPLACED LAVATORY LIGHT ASSY BALLAST IAW AMM 33-23-00. NO BURN ELECTRICAL SMELL NOTICED.SDR ASOA20120930079Light · burnedTHE CREW REPORTED SMOKE ODOR IN COCKPIT. MX INSPECTED AND FOUND CABIN SIDE WALL LIGHT ASSY BURNED. THE LIGHT ASSY WAS DISCONNECTED. MX INSPECTED AND REPLACED 6A SIDEWALL LIGHT ASSY. OPS CHECKS WERE GOOD.SDR SIMA20120930006Light · inoperativeON FLIGHT 3536 THE CREW REPORTED THAT A PASSENGER REPORTED A LIGHT BLUB BURNED OUT AT SEAT 5A WITH A BURNING SMELL AND AREA AROUND LIGHT SOCKET WAS OVERHEATED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE 5A READING LIGHT BLUB IAW EMB 145 SDR SWIA201231887Fixture · defectiveELECTRICAL SMELL COMING FROM AFT CABIN. SMELL SLOWLY DISSIPATED ONCE CABIN LIGHTS WERE TURNED OFF. (FLT 7799) REPLACED SIDEWALL LIGHT FIXTURE AT SEAT 7D IN REFERENCE TO EMB 120 AMM. P/N: BC1-0047-005 S/N OFF: N/A.SDR ASOA20120927088Light · odorELECTRICAL BURNING ODOR IN CABIN REPORTED BY CREW. MX R & R THE LIGHT ASSY ABOVE ROW 15-16.SDR WX0A071342Light · shortedPILOT: SMELL OF ELECTRICAL SMOKE REPORTED BY F/A'S BEFORE LANDING BUT NO VISIBLE SMOKE SEEN, REPORTED FROM FRONT TO BACK OF CABIN. FOUND LIGHT BULB ON OVERHEAD SIDE WALL ROW 28DEF SHORTING OUT. RELAMPED OVERHEAD SIDE WALL LIGHT IAW MM 33-21-03. OP'S CHECK NSDR ASOA20120927127HLight · burnedDURING CRUISE THE CREW RPORTED AN ELECTRIC BURNING ODOR IN THE CABIN. THE ACFT LANDED WITHOUT INCIDENT WHERE MX INSPECTED THE ACFT AND R & R THE LIGHT ASSY ABOVE ROW 15-16. OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20120920353Ballast · sparksCREW REPORTED THAT THE CEILING LIGHT OVER SEAT 1A WAS SPARKING. THE LIGHT BALLAST WAS PLACED ON MEL AND THE FINAL CORRECTIVE ACTION AND PART INFORMATION WILL BE SUBMITTED AS A SUPPLEMENT TO THIS REPORT.SDR SWIA201231790Light · brokenPASSENGER IN 10D HAD GLASS SHARDS FALL ON THEM. ALSO REPORTED BURNING SMELL AFTER GLASS FELL ON THEM. (FLT 6497) CABIN FLUORESCENT LIGHT AT 10D WAS BROKEN. REPLACED THE SIDEWALL LIGHTS AT SEAT 9D AND 10D IAW AMM.SDR YENA20120908601Power Unit · defectiveFLT 852 SJU-BOS, DURING CRUISE, IN-FLIGHT CREW REPORTED A BURNING SMELL ADJACENT TO ROW 23-25. ALL COCKPIT INDICATIONS WERE NORMAL. AS PRECAUTION THE FLIGHT CREW REMOVED POWER FROM THE AFT AVIONICS POWER RACK. IN-FLIGHT CREW MEMBERS REPORTED THE DISCOVERY OSDR ASOA20120906120HLight · overheatedTHE CREW REPORTED A STRING ELECTRICAL BURNING ODOR AROUND ROW 14. MX INSPECTED THE ACFT AND R & R THE SIDEWALL LIGHT ASSY AT ROW 15 RT, OPS TESTED WITH NO DFECTS, AND THE ACFT WAS APPROVED OFR RETURN TO SERVICE.SDR UALA2012090505001Light · inoperativeLAVATORY LIGHTS INOP AT DOOR 3L AFT CABIN FWD LAV. RELAMPED, OPS CHECK GOOD.SDR SIMA20120901012Light · inoperativeDURING MAINTENANCE INSPECTION FOUND THE NR 1 EMERGENCY LIGHT FLOOR STRIP INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 1 EMERGENCY LIGHT STRIP IAW EMB 145 AMM 33-50-12. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURSDR ASOA20120901072Light · odorREPORTED BURNING ODOR FROM CABIN LIGHT OVER 11A SIDEWALL LIGHT. MX R & R CEILING LIGHT ASSY OVER 11A WITH OPS CHECK SUCCESSFUL. ACFT APPROVED FOR RETURN TO SERVICE.SDR A6WA201240819Ballast · overheatedSTRONG ELECTRICAL BURNING ODOR AT ROW 1 AND AFT. INVESTIGATED AND FOUND TO BE OVERHEATED BALLAST FOR SIDEWALL LIGHTS ABOVE BIN 1D AND 2D. SEE 250417/3 FOR MEL. INSTALLED NEW BALLAST ASSY - OPS CHECKS GOOD, REMOVED PLACARD/MEL.SDR SIMA20120827001Ballast · unserviceableFLIGHT 3695, NR 2 FLIGHT ATTENDANT REPORTED A STRONG "BURNING" ODOR FROM THE VENTS OVER SEAT 18 A/B. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED PS62 BALLAST IAW MM 33-21.03. AIRCRAFT RETURNED TO SERVICE.SDR HNAA2012082700930Ballast · failedELECTRICAL ODOR IN CABIN MID TO AFT AREA, ROW 7. R & R PUSH BUTTON SOCKET END FOR CABIN OVERHEAD LIGHT AT 7AC. R & R BALLAST FOR OVERHEAD LIGHT. OPS CHECKED GOOD.SDR UALA2012082704806Controller · faultyC & D ZONE CABIN LIGHTS WILL NOT SHUT OFF. REPLACED LAC2, OPS CHECK GOOD.SDR SIMA20120824004Ballast · failedON FLIGHT 3753, THE CREW REPORTED A STRANGE ODOR IN THE FLIGHT DECK. IT SMELLED LIKE SOMETHING ELECTRIC WAS BURNING. THE ODOR WAS BURNING THE CAPTAIN’S AND FIRST OFFICER’S EYES. THE AIRCRAFT WAS REMOVED FROM SERVICE. INSPECTED AIRCRAFT AND FOUND ENTRANCE LSDR UALA2012082204683Light · inoperativeFWD AFT LAV NO LIGHTING WORKS.SDR AALA20120819010Light · shortedMIA - CREW REPORTED ELECTRICAL SMELL FROM POWER PORT/LIGHT AT SEAT 4B. LIGHT BETWEEN SEATS 5A/B FLICKERED TOGETHER ON AND OFF. TURNED POWER PORT OFF BUT SMELL CAME BACK. EMERGENCY DECLARED FLIGHT RETURNED MIA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SDR TRBA20120817001Bulb · inoperativeFOUND NO SMOKING SIGN IN ROW 8 AB INOPERATIVE. REPLACED BULBS IAW 36-26-21. OPS CHECKED OK.SDR QXEA2012081600818Light · looseFLOURESCENT STRIP NEAR DOOR IS LOOSE. REMOVED LOOSE STRIP, CLEANED AREA AND REINSTALLED WITH NEW TAPE. RETURNED TO SERVICE.SDR TRBA20120816001Light · inoperativeFOUND NO SMOKING SIGN FOR 12CD ARE INOPERATIVE. ACFT REMOVED FROM SERVICE. REPOSITIONED NO SMOKING SIGN 12 CD IAW JIC 33-20-00. OPS CHECKED OK. ACFT RETURN TO SERVICE.SDR F3LA2012081500777Ballast · failedODOR COMING FROM AFT CABIN. R & R BALLAST ASSY COVE LIGHT AT ROW 24 DEF. OPS CHECK GOOD, NO TROUBLE NOTED REF AMM 33-21-11, PAGE BLOCK 401.SDR ASOA20120813129Bulb · burnedACFT RETURN TO THE GATE WHEN A BURNING ODOR IN THE CABIN WAS DETECTED. MX FOUND THE 2A LIGHT BURNED OUT. ACFT WAS THEN RELEASED TO SERVICE.SDR DALA1246300685Transformer · defectiveSHIP 685 EXPERIENCED A CHEMICAL SMELL COMING FROM THE GASPERVENT FORWARD GALLEY RIGHT SIDE. NO DEVIATION FROM NORMAL OPERATING PROCEDURES. MAINTENANCE DETERMINED THE CAUSE TO BE THE LEFT CEILING LIGHTING TRANSFORMER. REMOVED AND REPLACED THE LIGHTING TRANSFSDR HNAA2012081300916Fixture · burnedCABIN O/H LIGHT AT 6D/F FWD FIXTURE END SMOKING. MX INSPECTED AND FOUND FWD END BURNED AND PULLED AND COLLARD CIRCUIT BREAKERS S1, S2, AND R2 PER SP 33.1.SDR USAA2012081300032Ballast · shortedCLT FLT 725 EN ROUTE DUB TO CLT. ODOR AROUND AFT LEFT LAV ELECTICAL SMELL FROM MIRROR LIGHT BALLAST. REMOVED AND REPLACED AFT LEFT LAV LIGHT BALLAST.SDR DALA1245151809Light · failedON PUSH BACK, FLIGHT ATTENDANT AT R3 DOOR DETECTED AN ELECTRICAL ODOR. FIRST OFFICER WENT BACK AND FOUND FLOURESCENT LIGHT AT R3 DOOR OUT WITH PLASTIC COVER MELTED AT SOCKET POINT. FOUND FLOURESCENT LIGHT ASSY SOCKET END DAMAGED. REMOVED AND REPLACED LIGHT SDR ASOA20120806068Ballast · failedTHE CREW REPORTED SMOKE FROM 4C SIDEWALL LIGHT. MX REPLACED 4 B & C LIGHT ASSY AND 4 B&C LIGHT BALLAST. OPS CHECKS WERE GOOD.SDR CA120813024Ballast · overheated(CAN) STRONG BURNING ODOR NOTICED IN FRONT SECTION OF PAX CABIN. FOUND A BAD BALLAST AT STORAGE BIN 4AB. R & R BALLAST.SDR ASOA20120803058RBulb · smokeCREW REPORTED SMOKE FROM 4C SIDEWALL LIGHTS. MX REMOVED BULB. OPENSDR UALA2012073004114Controller · inoperativeFLIGHT ATTENDANT UPPER DECK LIGHTING CONTROL PANEL INOPERATIVE, REPLACED NR 4 LAC AND RELOADED ACCESS SOFTWARE.SDR SWAA2012072706229Ballast · faultyFORWARD GALLEY LIGHT FILLED GALLEY WITH SMELL OF SMOKE. REMOVED AND REPLACED LIGHT BALLAST PER MM.SDR UALA2012072604062Light · odorCREW REPORTS BURNING ODOR IN VICINITY OF THE FWD AFT LAVATORY. ODOR COMING FROM HALOGEN LIGHT FIXTURE AS IDENTIFIED IN DF131 AND DF130. REPLACED LIGHT FIXTURE REF IPC 33-24-04 ITEM 17-10. ALSO INSPECTED ABOVE LAV, OTHER AREAS OF THE LAV AND AFT GALLEY. NO ODOSDR UALA2012072504044Lamp · inoperativeDURING M CHECK, FOUND CEILING LIGHT AT 34K INOP. REPLACED LAMP.SDR UALA2012072303959Socket · faultyUPPER DECK CEILING LIGHT AT SEAT 17 IS INOPERATIVE. REPLACED LIGHT SOCKETS. CHECKS NORMAL.SDR RAIA201207210001Ballast · burnedDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED A BURNING ODOR IN THE PASSENGER COMPARTMENT. MAINTENANCE INSPECTED AND FOUND THE SMELL COMING FROM THE BALLAST FOR THE OVERHEAD LIGHT AT SEAT 9A. THE BALLAST WAS DISCONNECTED AND THE LIGHT WAS DEFFERED PESDR ASOA20120720100HBulb · failedTHE CREW REPORTED A BURNING ODOR IN THE CABIN FROM THE SIDEWALL LIGHTS IN ROW 3 & 4. R & R LIGHT BULB AT SEAT 3BC, OPS TESTED WITH NO DEFECTS, ACFT WAS APPROVED FOR RETURN TO SERVICE.
Back to JASC 3320