JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2012072001945Socket · failedSTRONG ODOR OF ELECTRICAL SMOKE IN COCKPIT. F/A, F/O AND CAPTAIN NOTICED. F/A STATES SOME HOT SPOTS ON WALL NEAR OR BEHIND COFFEEMAKER. STRONGEST ODOR IN COCKPIT NEAR F/O'S CEILING CIRCUIT BREAKER PANEL. ENROUTE, ACFT DIVERTED, EMERGENCY DECLARED. INSPECTED SDR REXA2012071601159Power Supply · failedELECTRICAL BURNING ODOR IN BACK OF CABIN. NOTED OVERHEAD LIGHT POWER UNIT DIMMER AT 8-9AD FAILED, CAUSING ODOR. REPLACED POWER UNIT IAW AMM 33-21-04 AND REPLACED OVERHEAD LTS ABOVE 8-11AB PER AMM 33-21-01. OPS CHECKED GOOD.SDR SIMA20120709003Ballast · burnedFLIGHT 3355, CREW REPORTED THEY NOTICED AN ODOR NEAR THE COCKPIT AND GALLEY. THE FLIGHT ATTENDANT TURNED OFF LIGHTS AND COFFEEMAKER AND THE ODOR DISAPPEARED. AIRCRAFT REMOVED FROM SERVICE. FOUND SIDEWALL BALLAST ON ROW 18BC SMELLING BURNED. REMOVED AND RSDR UALA2012070603637Ballast · failedFLIGHT ATTENDANTS REPORTED AN ELECTRICAL ODOR IN AFT GALLEY. INSPECTED AFT GALLEY ELECT COMPONENTS, COFFEEMAKERS, OVENS, WORK LIGHTS, FOUND BURNED BALLAST FOR 24LG RT ENTRY LIGHT AT DOOR 2. DISCONNECTED BALLAST AT 7206VC DISCONNECT, VENTILATED CABIN TO DISSISDR SIMA20120704006Ballast · defectiveON FLIGHT 3329 THE FLIGHT ATTENDANT NOTIFIED THE CREW OF AN ELECTRICAL ODOR IN THE GALLEY. THE CREW RAN THE CABIN/COCKPIT SMOKE/FIRE CHECKLIST IN AOM VOL 1. THE CREW DECLARED AN EMERGENCY AND DIVERTED TO SAT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRSDR FDEA201207032478Light · shortedDURING CRUISE, FOUND CIRCUT BREAKER LABLED "FIN & ENG" TRIPPED. AIRSTAIR AREA LT MID LIGHT ASSY SHORTED OUT. INSTALLED LIGHT ASSY TO EXISTING WIRES PER SWPM 20-30-12. OPS CHECKED GOOD PER AMM 33-30-000-0. LIGHT ILLUMINATED FOR 30 MINUTES WITH NO BREAKERS TRSDR UALA2012062903432Ballast · odorFLIGHT ATTENDANT REPORTED SMOKE ODOR INSIDE FWD LAV. REPLACED BALLAST IN FWD LAV, NO DAMAGE FOUND OTHER THAN BALLAST, CHECKED ASSOCIATED WIRING OK.SDR SWIA201231141Ballast · defectiveAN ELECTRICAL SMELL IN LAVORATORY. (FLT 4688) REPLACED LAVORATORY LIGHT BALLAST IN REFERENCE TO AMM.SDR UALA2012062903478Light · inoperativeFLIGHT ATTENDANT REPORTED SMOKE ODOR INSIDE AFT FWD LAV. REPLACED BALLAST IN AFT FWD LAV, NO DAMAGE FOUND OTHER THAN BALLAST, CHECKED ASSOCIATED WIRING OK. MIRROR LIGHT INOP, DOME LIGHTS OPS GOOD.SDR UALA2012062903470Ballast · defectiveFLIGHT ATTENDANT REPORTED SMOKE ODOR INSIDE AFT FORWARD LAV. REPLACED BALLAST IN AFT FORWARD LAV, NO DAMAGE FOUND OTHER THAN BALLAST, CHECKED ASSOCIATED WIRING OK. REPLACED BULBS NO HELP. MIRROR LIGHT INOP, DOME LIGHTS OPS GOOD. SEE PTT 7602003 FOR CORRECTSDR VNAA2012062500009Ballast · defectiveCREW REPORTED SLIGHT BURNING SMELL IN AREA OF ROWS 1-3. MAINTENANCE INSPECTED, REMOVED AND REPLACED BALLAST AND BULBS FOR BOARDING LIGHTS AND PERFORMED CHECKS USING AIRCRAFT MAINTENANCE MANUAL. AIRCRAFT RELEASED FOR SERVICE.SDR UALA2012062903413Lamp · inoperativeFWD LAVATORY LIGHTS INOPERATIVE. RELAMPED, OPS CHECKED GOOD.SDR VNAA2012062300006Power Unit · malfunctionedCREW REPORTED STRONG ODOR COMING FROM AROUND ROW 3, POSSIBLY BURNING PLASTIC. MAINTENANCE INSPECTED AND FOUND POWER UNIT DIMMER AT ROW 4A/C TO HAVE STRONG BURNING SMELL. MAINTENANCE REMOVED AND REPLACED POWER UNIT AND PERFORMED CHECKS USING AIRCRAFT MAINTENASDR RAIA201206220001Ballast · malfunctionedCREW REPORTED A SMOKE SMELL COMING FROM OVERHEAD LIGHT BALLAST AT ROW 2, DURING CRUISE. AFTER MAKING ITS SCHEDULE LANDING, MAINTENANCE INSPECTED AND DEFERRED THE CABIN LIGHTING AT ROWS 3 AND 4.SDR SIMA20120620013Light · defectiveDURING B INSPECTION FOUND THE READING LIGHT ASSEMBLY ABOVE SEAT 11A IS EMITTING A BURNING ODOR AS SMOKE IS VISIBLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. LIGHT BULB REMOVED. ENTIRE LIGHT ASSY NEEDS REPLACEMENT. PARTS NOT AVAILABLE. DEFERRED AS NEF 25-21CSDR SWIA201231071Light · odorELECTRICAL BURNING ODOR IN MAIN CABIN BETWEEN ROWS 3 AND 6. (FLT 5265) REPLACED BURNT LIGHTS AND POWER UNIT/DIMMERS AT ROW 3D AND 6D.SDR USAA2012062200011Ballast · odorEN ROUTE PLS, FLIGHT ATTENDANT AND PASSENGERS REPORTED ELECTRICAL SMELL AROUND ROW 18, 19, & 20. FLIGHT ATTENDANT TURNED OFF OVERHEAD READING LIGHTS. ODOR STARTED TO DISSIPATE. REMOVED AND REPLACED SIDEWALL LIGHT AND BALLAST AT ROWS 18 & 19 RIGHT PER AMM 33SDR UALA2012062203353Ballast · inoperativeTHE 13JK SIDEWALL LIGHT INOP. RELAMPED, NO HELP. BALLAST REPLACED AND LIGHT TUBE REPLACED, NIL HELP. NEED MORE TIME FOR TROUBLESHOOTING. REPLACED BALLAST. OPS OK.SDR UALA2012062203335Switch · out of positionDOOR 2L LAV OCCUPIED LIGHT DOESN'T GO OUT. RETURNED LAV 2L DOOR SWITCH TO NORMAL CONFIGURATION. CHECK OK.SDR QXEA2012061200436Light · overheatedPOSSIBLE ELECTRICAL TYPE ODOR IN AFT GALLEY AREA. COMPLIED WITH AIR CONTAMINATION CHECKLIST, WAS ABLE TO DETECT A VERY SLIGHT ELETRICAL ODOR FROM AFT GALLEY UPPER BULKHEAD VENTS. PERFORMED INSPECTION OF AFT CARGO BAY AREA, FOUND ELECTRCAL ODOR COMING FROM ASDR QXEA2012061100437Light · burnedSTRONG ELECTRICAL BURNING ODOR IN ROW 4 & 5 AFTER SHUTDOWN IN THE GATE. INSPECTED CABIN, PERFORMED GVI UNDER CENTER FLOOR PANELS, CEILING LIGHTING, CARGO COMPARTMENTS, HOT JUGS, APU SHUNT, FOUND BURNED READING LIGHT AT 7B. REPAIRED. RETURNED TO SERVICE.SDR CHQA20120609183Ballast · failedCREW REPORTED AN ELECTRICAL ODOR FROM THE CEILING LIGHT AT SEAT 1A. REMOVED AND REPLACED CEILING LIGHT BALLAST. OPS CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.SDR ASOA201201772Ballast · overheatedCOCKPIT FILLED WITH ELECTRICAL FUMES IN FLIGHT. CONSISTENT DISPERSION INCREASE AND DECREASE WITH THRUST LEVERS, EMERGENCY DECLARED, DIVERTED. FOUND GALLEY LIGHT BALLAST OVERHEATED. R & R LIGHT BALLAST IAW AMM 33-26-05.SDR UALA2012060303061Oxygen Mask · unwanted deploy32ABC O2 MASK DEPLOYED ON LANDING. STOWED DROPPED MASKS AT LOCATION 32ABC.SDR DALA1235000967Ballast · failedREPORT OF STRONG ELECTRICAL BURNING ODOR IN THE MIDDLE TO AFT CABIN AREAS. MAINTENANCE REPLACED A CABIN LIGHTING BALLAST AND BULB.SDR UAL2012F00003Ballast · defectiveELECTRICAL BURNING ODOR NEAR DOOR 2. FOUND AFT FWD LAVATORY MIRROR LIGHT BALLAST DEFECTIVE AND LIGHTS OUT. ODOR DISSIPATED. BALLAST AND BULBS REPLACED, RAN BOTH ENGINES AND FOUND NO BURNING ODOR.SDR UALA2012060103056Ballast · defectiveELECTRICAL BURNING SMELL NEAR DOOR 2. FOUND AFT FWD LAV MIRROR LIGHT BALLAST DEFECTIVE & LIGHTS OUT. SMELL DISSIPATED. BALLAST CONNECTOR REMOVED, TAPED & SECURED. DEFER ITEM ENTERED IN ERROR. SMC 01 CREATED FOR THIS DEFECT. BALLAST AND BULBS REPLACED, RASDR ASOA20120522079Light · burned outTHE CREW REPORTED SMOKE IN THE CABIN NEAR SEAT 2A & NEAR THE GALLEY COMING FROM CEILING PANELS. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MX INSPECTED THE ACFT AND FOUND THE FORWARD GALLEY LIGHT BURNED OUT WITH NO OTHER EVIDENCE OF BURSDR VNAA2012052300020Ballast · defectiveCREW REPORTED GALLEY SMELLS LIKE ELECTRICAL BURNING. MAINTENANCE TROUBLESHOT, FOUND FORWARD BALLAST BAD, REMOVED AND REPLACED BALLAST AND PERFORMED CHECKS OF GALLEY LIGHTS USING AIRCRAFT MAINTENANCE MANUAL. AIRCRAFT RELEASED FOR SERVICE.SDR UALA2012052102845Ballast · odorBURNING SMELL FROM AFT GALLEY W- COFFEE AND CHILLERS ON. FOUND AFT FA PANEL LOCKED UP, CYCLED POWER AND FAULT CLEARED. REPLACED BOTH AFT OVERHEAD LIGHTS ASSEMBLIES & BALLAST AND RELAMPED. GROUND CHECKED OKAY.SDR REXA2012052000762Light · inoperativeFLIGHT ATTENDANT CALL LIGHT INDICATION ON EMERGENCY EXIT (MID CABIN) LIGHT INOP. REMOVED AND REPLACED FLIGHT ATTENDANT CALL LIGHT INDICATION, OP CHECK GOOD IAW AMM 33-51-14. OK FOR SERVICE.SDR EE4Y2012060500239Light · failedUPPER FUSELAGE PAX CABIN ILLUMINATION TEST SHOWS CLASS 3, FAILURE. REPLACED AND TESTED PAX CABIN READING LIGHTS AT POSITIONS 25C AND 25D IAW THE AMM TASK REF: 23-73-64-000-001-A AND 23-73-64-400-001-A SASTISFACTORY CONDITION.SDR ASOA20120515075Control Module · inoperativeDURING PREFLIGHT INSPECTION THE CREW REPORTED SMOKE IN THE CABIN ABOVE SEAT 1A. CONTRACT MX INSPECTED THE ACFT AND R & R THE CABIN LIGHT CONTROL MODULE, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CALA2012050700329Light · intermittentRAN IFE /PASS SUPPLY CHECK LIST TO HELP RESTORE IFE, NR 3 FLT ATT REPORTED INTERMITTENT FLUORESCENT LIGHTS FLICKER IN CABIN AND A ODOR OF ELECTRICAL SHORT NEAR DOOR 3R TURNED OFF IFE INSPECTED NOTED AREA AROUND 3R DOOR ALSO OPERATED (CSAP) COMPARTMENT CHECK ALSDR ASOA201201643Fixture · burnedBURNING ODOR IN COCKPIT AND GALLEY AREA. (WORK LIGHTS) R & R BURNED GALLEY LIGHT FIXTURE. OPS CHECKED GOOD IAW AMM 33-26-047.SDR WX0A071175Ballast · malfunctionedFLIGHT CREW PERSONNEL REPORTED SMOKE FROM ROW 36 DEF FROM PASSENGER SERVICE UNIT. MAINTENANCE DEPARTMENT REMOVED AND REPLACED LIGHT BALLAST IAW MD80 AMM 33-50. AIRCRAFT RETURNED TO SERVICE.SDR UALA2012042002393Lamp · inoperativeSEAT BELT AND NO SMOKE SIGN INOPERATIVE. REPLACED LAMPS, OPS CHECKED OKAY.SDR UALA2012041502276Conduit · unsecureCREW REPORT: STILL HAVE OCCASIONAL LOUD HUMMING IN FWD GALLEY ONCE PRIOR TO LEVEL OFF AND JUST AFTER DESCENT. OPENED CEILING PANELS IN FWD GALLEY FOUND ENTRY LIGHT CONDUITS NOT SECURED, SECURED CONDUITS. NO OTHER DEFECTS FOUND. REINSTALLED PANELS.SDR UALA2012041202204Light · shortedSTRONG ODOR IN AFT GALLEY OF BURNING ELECTRICS, WHEN POWER CUT. FOUND AFT LAVATORY OCCUPIED LIGHT ASSY SHORTED OUT. REPLACED SIGN ASSY AND LENS. OP'S CHECKED GOOD, NO BURNING ODOR.SDR REXA2012040800486Bulb · inoperativeREAR INTERIOR EMERGENCY CABIN CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED BULB IAW AMM 33-20-00, OPS CHECKED GOOD.SDR UALA2012040502101Light · malfunctionedBLUE PASS CALL LIGHTS ON IN COACH CABIN WITH NO SEAT CALL BUTTON ILLUMINATED. CHIME OK. CYCLED CABIN POWER. LIGHT EXTINGUISHED AND OPS CHECK GOOD AT ALL SEATS.SDR UALA2012040502112Module · faultyUNABLE TO CONTROL ZONE CABIN LIGHTING. SWAPPED ZMU NR 1 WITH ZMU NR 3 PER AMM, OK.SDR MASA201204054655Lamp · inoperativeCABIN OVERHEAD LIGHT INOPERATIVE ON PRE FLIGHT INSPECTION. MX REPLACED LAMP IN THE LIGHT ASSY.SDR SWIA201230319Light · odorFLT 5320, HOT PLASTIC ODOR IN LAVATORY. FOUND LAVATORY LIGHT ASSEMBLY TO HAVE BURNING ODOR. REPLACED LAVATORY LIGHT ASSEMBLY IAW AMM.SDR NSVA20120331495Socket · burnedPAX REPORTED ELECTRICAL ODOR FROM ROW 8. REMOVED AND REPLACED ROW 8 SIDEWALL LIGHTING SOCKET ASSY AND BULB. OPS CHECKED GOOD.SDR UIEA2012032900108Light · malfunctionedINDIRECT CEILING LIGHTS AT ROW 2 AND ROW 12 AND ROW 30 INTEMITTENTLY INOPERATIVE INBD AND OTBD.SDR WX0A071136Ballast · malfunctionedFLIGHT CREW REPORTED READING LIGHTS IN ROW 27 D- E- F PRODUCE SMOKE WHEN TURNED ON. MAINTENANCE PERSONNEL INSPECTED AND FOUND UPPER SIDEWALL LIGHT BALLAST AND UPPER LIGHTS INOP. REMOVED AND REPLACED BALLAST IAW AMM 33-21-03, OPS CHECK GOOD. READING LIGHTS OSDR UALA2012032601914Lamp · inoperativeRETURN TO SEAT LIGHT INOPERATIVE AT 1L. RELAMPED FASTEN SEAT BELT SIGN AT DOOR 1L, CHECKED OKAY.SDR CHQA20120322086Ballast · faultyCREW REPORTED, DURING FLIGHT THERE WAS AN ELECTRICAL BURNING SMELL AROUND ROW 15. MAINTENANCE FOUND THE OVERHEAD LIGHT BALLAST AT ROW 15 TO BE INOPERATIVE. THE LIGHT WAS DISCONNECTED AND DEFERRED. THE DEFERRAL WAS CLEARED ON 3/23/2012 BY REPLACING THE LIGHTSDR AALA20120320018Ballast · defectiveATL - FLIGHT ATTENDANTS REPORTED ELECTRICAL BURNING SMELL AND SMOKE IN AFT CABIN. EMERGENCY DECLARED FLIGHT RETURNED ATL LANDED WITHOUT INCIDENT. REPLACED BALLAST AT SEAT 26AB THAT WAS BAD. SYSTEM GROUND CHECK NORMAL OPERATION.
Back to JASC 3320