Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MASA2012030934544Light · inoperativePAX DOOR STEP LIGHT INOP. RELAMPED PAX DOOR STEP.SDR CALA2012030900175Light · inoperativeF/A REPORTED "BURNT PEANUT" FUMES IN FWD COACH CABIN, WITH RECIRC FANS OFF, THE ODOR WENT AWAY. ANOTHER F/A REFERRED TO SMELL AS BURNT RUBBER. F/A IN AFT GALLEY REPORTED NO FUMES. PERFORMED TASK 05-51-26-800-801C1 WITH ENG RUNS AND RECIRC FAN TEST NO DEFECTSDR UALA2012030501365Light · defectiveCEILING LIGHT ASSY L33146 LOCATED AT 84IN OVERDOOR FAIRING M33200 AT STA 1520 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD NO 3321-01018 REV B PG 8 STEP 19. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2012030501361Light · defectiveCEILING LIGHT ASSY L33146 LOCATED ABOVE LAV AT STA 830 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD 3321-0 1018 REV B PG 6 STEP 2. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2012030501359Light · defectiveCEILING LIGHT ASSY L33145 LOCATED ABOVE LAV AT STA 830 RBL 90, CONNECTOR IS NON COMPLIANT PER FCD NO 3321- 01018 REV B PG 9 STEP 21 BY- 138136. REPLACED LIGHT ASSY PER MM.SDR UALA2012030501358Light · faultyRIGHT AFT LAV WIRE BUNDLE W236 ON OTBD 35IN FAIRING M33036 AT STA 1990 RBL 90, CONNECTOR DM33036B IS NON COMPLIANT PER FCD NO 3321-01019 REV A PG 39 STEP 21. REPLACED LIGHT ASSY PER MM. PLANE SIDE CONNECTOR STILL NON COMPLIANT.SDR UALA2012030501357Light · defectiveCEILING LIGHT ASSY L33145 OVER DOOR 2L FAIRING AT STA 760 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD NO 3321 -01018 REV B STEP 11 PG 4. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2012030501356Light · defectiveCEILING LIGHT L33146 OVER DOOR 2L FAIRING AT STA 760 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD NO 3321-0101 8 REV B STEP 10 PG 4. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2012030501366Connector · faultyCABIN LIGHTING HARNESS W6169 LOCATED ON STR CLIP BETWEEN STA 1580 & 1601 ON STR 12R, CONNECTOR D5188P IS NON COMPLIANT PER FCD NO 3321-01019 REV A PG 41 STEP 4. REPLACED CONNECTOR. TESTS OKAY.SDR ASOA20120224027Ballast · overheatedDURING PRE-FLIGHT INSPECTION THE CREW REPORTED A BURNING ODOR FROM THE GALLEY AREA. MX R & R THE LIGHTING BALLAST AT SEAT 2A, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CA120228016Ballast · overheated(CAN) AIRCRAFT RETURNED TO DEPARTURE AIRPORT DUE TO AN ELECTRICAL ODOR IN THE FORWARD LAVATORY. CREW PULLED APPROPRIATE CIRCUIT BREAKERS TO ISOLATE AND RETURNED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTION DISCOVERED THE FORWARD L1 LAVATORY LIGHT BALLASTSDR HNAA2012022000594Bulb · out of positionBURNING ODOR WITH LOWER GALLEY LIGHTS ON (BUFFET LIGHTS), NO ODOR WITH LIGHTS OFF. INSPECTED LIGHT ASSY'S AND FOUND BULB TOUCHING LENS ON AFT POSITION. REPOSITIONED, OK FOR SERVICE. NO ODOR DETECTED WITH LIGHTS ON (NO DAMAGE TO LENS).SDR UALA2012022701151Light · inoperativeD' ZONE SEATS A-G READING LIGHTS INOP. D-ZONE CTR SECTION ROWS 34-41DEFG INOP^18FEB SFO INF- :ZONES C+D CENTER COLUMN UNCONTROLLABLE. RPL'D LAC NR 2, NO HELP. P :FOUND DAMAGED CABLE NEAR 34D FROM FLOOR TO SEU. INSTALLED ANOTHER CABLE. PROBLEM STILL EXISTSSDR SWAA2012022001552Light · inoperativeAFT GALLEY SMOKE ODOR DETECTED. ODOR GONE WITH GALLEY LIGHTS EXTINGUISHED. REMOVED AND REPLACED AFT GALLEY WORK LIGHT ASSY PER M/M.SDR SIMA201204801Ballast · failedON FLIGHT 4458, CREW REPORTED THAT WHILE POWERING UP AT THE GATE THE FLIGHT ATTENDANT’S LIGHTING PANEL DID NOT WORK. AN ODOR OF BURNING WIRE WAS COMING FROM THAT AREA. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FORWARD CEILING BALLASTS SDR SWAA2012021301396Ballast · faultyVISIBLE SMOKE IN CABIN ROW 19 20 21 CAPTAINS SIDE. FOUND DEFECTIVE BALLAST AT ROW 19ABC. REMOVED AND REPLACED SIDEWALL LIGHT BALLAST PER MM.SDR CA120208006Light · shorted(CAN) SIDEWALL LIGHT 4F SHORTED OUT AND SPARKED CAUSING SLIGHT SMOKE IN CABIN. CONSIDERABLE CONDENSATION NOTICED. RESOLVED ON WO: 323780 TASKCARD: NR-00001, SIDEWALL LIGHT ASSY, PN, BCI -0065-003, AT ROW 4DF REPLACED AND TESTED SERVICEABLE. LIGHTING FIXTURESDR UALA2012020700726Light · inoperativeAISLE STAND FLOOD LIGHT(S) - DO NOT COME ON. REPLACED LAMP AS PER AMM, OKAY.SDR MASA2012020394387Light · inoperativeASH FLIGHT 2731 REPORTED AN INOPERATIVE CABIN FLOOD LIGHT UPON TESTING IT. THE LIGHT WAS PLACED ON MEL.SDR DALA1205510175Ballast · malfunctionedCABIN CREW REPORTS SEVERAL FWD CABIN LIGHTS WENT OUT ELECTRICAL SMELL IN CABIN. FOUND BAD BALLAST D02690 M00671. REPLACED BALLAST P/N 05814-16 PER AMM B767-300 33-21. PVHD PNL RE-INSTALLED FWD CABIN OVHD LIGHTS, OP NORMAL. ETOPS CATEGORY 'E': PROBLEMS WITSDR VNAA2012020600017Ballast · malfunctionedCREW REPORTED ODOR COMING FROM CEILING ABOVE EXIT ROW. MAINTENANCE INSPECTED CABIN, REMOVED AND REPLACED OVERHEAD LIGHT BALLAST AT ROW 12 A/C AND PERFORMED CHECKS USING AIRCRAFT MAINTENANCE MANUALS. AIRCRAFT RELEASED FOR SERVICE.SDR UALA2012013000588Light · defectiveBOTH AFT LAV VANITY LIGHT COVERS DISCOLORED TO THE POINT THAT ITS DARK IN LAVS. STILL ALLOWS SATISFACTORY LIGHT TO PASS, COVERS NEED REPLACEMENT WITHIN 20 DAYS. REPLACED LENS BOTH LAVS.SDR ASOA20120119004Ballast · shortedSTRONG ODOR OF SOMETHING BURNING COMING FROM CABIN WITH NO SMOKE OR VISIBLE FLAME. MX R & R BALLAST ABOVE ROW 3 IAW AMM 33-21-05 WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20120116010Ballast · overheatedTHE CREW REPORTED A STRONG BURNING SMELL IN THE COCKPIT AND CABIN. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MX INSPECTED THE ACFT AND R & R THE LIGHTING BALLAST ABOVE ROW 1A, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPRSDR ASOA20110111008HBallast · defectiveTHE CREW REPORTED A BURNING ODOR IN THE CABIN BY SEAT 1A. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MX INSPECTED THE ACFT, R & R THE CONTROL MODULE, PC BOARD, AND LIGHT BALLAST AT SEAT 1A, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE SDR SWIA201229305Fixture · odorOVERHEAD CABIN LIGHT FIXTURE AT 7C IS GIVING OFF ELECTRICAL SMELL. (SERVICE) REPLACED CABIN LIGHT FIXTURE AT 7C.SDR UALA2012010900160Relay · faultyCEILING LIGHTS ENTIRE RIGHT SIDE WILL NOT GO OUT WHEN TURNED OFF. REPLACED RELAY K10073 PER WD 33-21-11, OPS NORMAL.SDR SWIA201229137Ballast · malfunctionedGALLEY LIGHT IS OUT WITH PLASTIC BURNING SMELL IN GALLEY. (FLT 6373) REPLACED LIGHT BALLAST IN AFT GALLEY.SDR ASOA201200050Ballast · failedELECTRICAL BURNING ODOR IN LAVATORY. FOUND LAVATROY VANITY LIGHT BALLAST TO BE SOURCE OF ODOR, DISCONNECTED BALLAST IAW AMM 33-25-02. (SDR SIMA201136205Printed Ckt Board · faultyIN CRUSE 7B CALL LIGHT FLICKERED THE STARTED SMOKING AND SMELL /RESET PSU SMOKE AND SMELL DISSIPATED NO EMERGENCY DECLARED. REMOVED AND REPLACED PSU PRINTED CIRCUIT BOARD AT 9BC, 7BC, 8A, AND 9A IAW EMB 145 AMM 33-25-04, OPS CHECK GOOD.SDR WRLA20111226529Ballast · defectiveELECTRICAL SMOKE SMELL IN A ZONE. PULLED CEILING LIGHTS OUTBOARD CIRCUIT BREAKER AND THE SMELL WENT AWAY. FWD CABIN LIGHT INOP. ITEM PUT IN DMI LOG DMI M33DE2011-214 MEL 33-10-01-01 CAT "C", DUE ON -01-12 C ON BALLAST DISC AND C/B PULLED ON CEILING LIGHT POSDR ASOA20111222017Lamp · burnedDURING POST FLIGHT THE CREW NOTED AN ELECTRICAL SMELL AROUND ROW 4 OF THE CABIN. READING LIGHTS WERE DETERMINED TO BE THE SOURCE OF THE ODOR. MX REPLACED THE READING LIGHT LAMPS AT ROW 4, OPS CHECKED THE SYS AND NO ODOR DETECTED.SDR HNAA2011122000435Light · failedOVERHEAD LIGHT AT ROW 2DF FAILED. R & R LAMP HOLDER, BULB AND BALLAST AT SEAT 2DF. OPS CHECKED GOOD.SDR UALA2011121906981Ballast · faultyG1 GALLEY LIGHT REPORTED FLASHING. AREA INSPECTED. NO ODOR OR EVIDENCE OF ARCING. INSPECTED BEHIND CIRCUIT BREAKER PANEL. NO ODOR OR EVIDENCE OF ARCING. RELAMPED LIGHT ASSY. NO HELP. CIRCUIT BREAKER PULLED AND COLLARED. ALL OTHER COMPONENTS OPS NORMAL. . REPLASDR MASA2011121964236Light · inoperativeCEILING LIGHT ROW 11 INOP. R2 LIGHT BULB.SDR UIEA2011121000711Bulb · failedUPON LANDING, CREW REST SOM L/E EICAS MESSAGE DISPLAYED ACCOMPLANIED BY SMOKE ODOR. NO VISIBLE SMOKE, PERFORMED "SMOKE OR FUMES IN CABIN, SOURCE UNKNOWN INSPECTION IAW FIM TASK 21-00 AND FOUND BURNED LIGHT BULB. NO OTHER DEFECTS NOTED. REPLACED LIGHT BULBSDR SWIA201128808Reflector · damagedSMOKE AND SIZZLING COMING FROM A LIGHT OVER GALLEY. (FLT 5609) REPLACED FORWARD GALLEY LIGHT REFLECTOR.SDR UALA2011120906766Ballast · failedTHE 17JK CEILING LIGHT INOP. RELAMPED, NO HELP. REPLACED BALLAST (585-4794) AND OP CHECKED GOOD.SDR CA111206003Ballast · overheated(CAN) THE FLIGHT CREW REPORTED A BURNING ODOR IN THE CABIN IN THE AREA OF ROWS 14-17. THE EMERGENCY LIGHTS IN ROWS 14-17 ILLUMINATED BY THEMSELVES AND WERE UNABLE TO BE SHUTOFF, ALSO, OF A CHLORINE ODOR IN THE AFT CABIN. R & R BALLAST IAW AMM 33-21-11, PB 401SDR DALA1165520922Light · odorWHILE IN CRUISE AT FL350, THE FLIGHT ATTENDANT REPORTED A "BURNING SMELL" NEAR SEAT ROW 27. THE UPPER & LOWER SIDEWALL CABIN LIGHTS WERE TURNED-OFF AND THE GALLEY POWER WAS SECURED. FURTHER REPORTS WERE THAT THE SMELL HAD DISSIPATED BY DESCENT TIME. LANDINGSDR UALA2011112206419Lamp · inoperativeLAVATORY LIGHTS INOPERATIVE AT DOOR-3L AFT-CABIN AFT LAVATORY. RELAMPED DOME LIGHT.SDR MASA2011112164065Ballast · malfunctionedLAV SMOKE DET WARNING. R2 LIGHT BALLAST IN THE FWD LAV.SDR USAA2011111800030Ballast · defectiveFLIGHT ATTENDANT REPORTED AN ELECTRICAL SMELL IN MID CABIN. MAINTENANCE PERFORMED INSPECTION AND FOUND BURNED OUT LAMP AND BALLAST AT ROW 22/23 LT. REPLACED SAME WITH NO FURTHER SMELL NOTED.SDR UALA2011111006138Light · faultyELECTRICAL SMELL ROW 32. PROG TEXT: - ITEM ROLLED FORWARD. SAMC TEXT CONTACT SAMC, ALSO CHECK UNDER SEAT WIRING HARNESSES IN AREA FOR ANY EVIDENCE OF ELECTRICAL DAMAGE. INSPECTED AREA FOR DAMAGE. FOUND SIDEWALL LIGHT AT SEAT ROW 32ABC INOP. REPLACED SIDEWSDR UALA2011110906109Module · faultyLIGHTS IN BUSINESS CLASS WILL NOT DIM. REPLACED ZMU IN ZONE 2 PER MM, SYSTEM OPS CHECKED GOOD.SDR CHQA201100425Ballast · defectiveCREW REPORTED THAT ON DESCENT THERE WAS AN ELECTRICAL ODOR IN THE CABIN. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE LIGHTING BALLAST AT ROW 3 AND ROW 5. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA2011313004Light · malfunctionedON FLIGHT 3305 THE CREW REPORTED THE SIDE LIGHTING IN CABIN, RIGHT SIDE FROM 5TH ROW THRU 12 ROW AND 15 ROW THRU 18, AND LEFT SIDE FROM ROW 9 THRU 11 AND 15 THRU 18 STOPPED WORKING; ACRID SMELL ACCOMPANIED. THE AIRCRAFT WAS REMOVED FROM SERVICE. INSPECTED SISDR SIMA2011312001Printed Ckt Board · malfunctionedON FLIGHT 3900 THE CREW REPORTED THE FLIGHT ATTENDANT CALL BUTTON LIGHTS FOR ROWS 7, 8, 9, 10 CAME ON UNCOMMANDED FOLLOWED BY REPORTS OF FUMES AND POSSIBLE LIGHT SMOKE. THE LIGHTS REMAINED ON UNTIL AIRCRAFT POWERED DOWN. THE AIRCRAFT LANDED WITHOUT INCIDENT.SDR SIMA201131101Ballast · inoperativeFOR FLIGHT 9301 THE CREW REPORTED THAT AS THEY PARKED AT GATE THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN GALLEY. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED LIGHT BALLAST RT8426 IAW AMM CH 33-21-03. THE OPERATIONAL CHECK WAS GOOD. SDR SIMA201130809Printed Ckt Board · burnedON FLIGHT 3900 THE CREW REPORTED THE FLIGHT ATTENDANT CALL BUTTON LIGHTS FOR ROWS 7, 8, 9, 10 CAME ON UNCOMMANDED FOLLOWED BY REPORTS OF FUMES AND POSSIBLE LIGHT SMOKE. LIGHTS REMAINED ON UNTIL AIRCRAFT POWERED DOWN. THE AIRCRAFT WAS REMOVED FROM SERVICE. F
Back to JASC 3320