JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011110305956Light · defectiveHOT ELECTRICAL SMELL, -NO SMOKE- OBSERVED. LOWER LOBE W-LIGHT TURNED ON. SAMC TEXT: IT IS THE READING LIGHT ONLY FOR THE UPPER-AFT- MOST BUNK IN THE LOWER LOBE. NO OTHER LIGHTS ARE CREATING THE SMELL. AREA LIGHT NOT AFFECTED. RELAMPED READING LIGHT, MONSDR ZZDA2011924Light · damagedREADING LIGHT 11D BROKEN COVER MISSING AND LIGHT SMOKES WHEN TURNED ON. UPON ARRIVAL TO A/C, NO UNUSUAL SMELLS NOTED & NO C/B'S WERE FOUND OPEN. FOUND READING LIGHT 11D DAMAGED. REMOVED LAMP ASSY & DISCONNECTED REF AMM 33-23, NO HISTORY IN LAST 30 DAYS. A/SDR DALA1161020665Light · inoperativeELECTRIC ODOR REPORTED IN FORWARD GALLEY. POWER WAS REMOVED FROM GALLEY COMPONENTS. SMELL DISSIPATED. FLIGHT CONTINUED TO MSP AND LANDED WITHOUT INCIDENT. FOUND 2 EA GALLEY OVERHEAD LIGHTS BLACK AND NOT WORKING. PERFORMED RELAMP OF BULBS AND OPS CHECKS NOSDR TRBA201130403Ballast · smokeNR 1 AND NR 2 CARGO COMPARTMENT ELECTRICAL SMOKE ODOR CONTINUES. REPLACED ROW 3 A-B LATERAL LIGHT BALLAST IAW JIC 33-21-21.SDR UALA2011102805852Power Supply · failedELECTRICAL ODOR NEAR EMERGENCY EXIT ROWS. FOUND BURNING ODOR EMANATING FROM READING LIGHT POWER UNIT LOCATED AT SEAT 21DEF. REPLACED UNIT AND CHECKED OPERATION PER AMM. OPS CHECKED NORMAL.SDR MASA2011102663912Lamp · inoperativeCEILING FLOOD LIGHTS INOPERATIVE. RELAMPED LIGHT.SDR AALA20111018TUL12Light · brokenMCO - INFLIGHT MIA-BOS. CREW REPORTED ELECTRICAL ODOR IN CABIN. EMERGENCY DECLARED FLIGHT DIVERTED MCO LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND LAMP HOLDERS AT FIRST CLASS GALLEY OVERHEAD LIGHT BROKEN. REPLACED LIGHT SOCKETS, LAMPS, BASDR CALA2011101800668Ballast · faultySMOKED FILLED THE CABIN BETWEEN DOOR 2 AND EMERGENCY WINDOW EXIT FOR ABOUT 1 MIN WITH AN ODOR ACRID SIMILAR TO ROTTEN EGGS/ A STINK MULCH WHICH LASTED ABOUT 4 MIN AT FL380 IN CIRRUS CLOUD INSP A/C PER AMM05-51-58 PG-901-801 AND AMM05-51-31 PG BLOCK 20 1 FOUND SDR SWAA117366Ballast · inoperativeRT READING LIGHT AT ROW 19 BURNED OFF. SMOKING POWER TO LIGHT TURNED OUT FIRST OFFICERS SIDE. REMOVED AND REPLACED BALLAST PER MM.SDR A6WA201140905Light · odorSTRONG ELECTRICAL SMELL IN CABIN, APPROX AT ROWS 5-8 ON GROUND. R & R PAX SIDEWALL LIGHT AT SEATS 7DF IAW AMM 33-21-07. R & R PAX CEILING LIGHT AT SEATS 7DF IAW AMM 33-21-01. R & R SIDEWALL LIGHT AND CEILING POWER UNITS IAW 33-21-04. OPS CHECK GOOD.SDR SWIA201128183Light · defectiveSMOKE IN THE CABIN ON APPROACH. (FLT 5316) REPLACED THE LIGHT FIXTURE, BALLAST AND LAMP NEAR SEAT 7A.SDR CHQA201100401Ballast · faultyCREW REPORTED AN ELECTRICAL BURNING ODOR FROM LIGHT 2A DURING FLIGHT. MAINTENANCE REMOVED LIGHT 2A . CHANGED THE 2A CEILING LIGHT BALLAST. OPS CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.SDR UALA2011101005474Module · failedCABIN LIGHTING MALFUNCTIONED. LIGHT MODULE PANEL MR23368 REMOVED. REPLACED NR 1 LAC AND CMU. REPLACED MODULE PANEL AT 1L, ALL LIGHTS OPERATED NORMAL. REPLACED UPPER DECK LIGHT MODULE PANEL. OPS CHECKED OKAY.SDR AALA20111008BOS01Light · shortedBOS - FLIGHT ATTENDANTS REPORTED SLIGHT BURNING ODOR IN MAIN CABIN. UTILITY BUSES TURNED OFF AND SMOKE DISSIPATED. FOUND LIGHT BALLAST AT SEAT 3A WITH EVIDENCE OF ODOR AND LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY AT SEAT 3A. SYSTEM GROUND CHECK NORMAL OPSDR REXA201100685Light · intermittentOVERHEAD EMERGENCY LIGHTS OVER ROW 8, FLIGHT ATTENDANT NOTIFICATION LIGHTS INTERMITTENT IN FLIGHT (LOWER LEFT CORNER). COULD NOT DUPLICATE DISCREPANCY. FLT ATT CALL LIGHTS OP TEST OK IAW AMM 33-22-03. OK FOR SERVICE.SDR N6WA20111005Light · burned outUPPER MOST STAIR LIGHT HALF BURNED OUT. DEFFERED UPPER STAIR LIGHT IAW MEL 33-21-02, CAT D ON DMI 19383.SDR DALA1157200942Ballast · defectiveFLIGHT CREW REPORTED SMOKE IN CABIN ORIGINATING APPROXIMATELY MID-CABIN FROM OVERHEAD. MAINTENANCE FOUND CEILING SIDE WALL BALLAST AT ROW 21 DE BURNT. REMOVED AND REPLACED BALLAST PER MAINTENANCE MANUAL. PERFORMED OPERATION 5088. CHECKS OKAY.SDR TRBA20111005001Bulb · odorDURING DESCENT, F/A REPORTED BURNING ODOR COMING FROM BETWEEN ROW 2 AND 3 ON RT SIDE OF ACFT. SMELLED LIKE WOOD BURNING. NO SMOKE. R & R 1AB AND 1CD LATERAL LIGHT BULBS IAW JIC 33-21-23. PERFORMED OPS CK OF CABIN AIR DISTRIBUTION IAW JIC 21-22-00 AND NO ABSDR TRBA201127803Bulb · failedUPON LANDING, THE FAS INFORMED ME THAT THE SAW AND SMELLED SMOKE IN THE FORWARD PART OF THE CABIN. R & R READING BULBS AT 1A, B AND 3 C, D IAW STANDARD PRACTICES 20-45-1.SDR TRBA201127601Light · failedON FINAL APPROACH, F/A CALLED AND ADVISED UD THERE WAS SMOKE IN THE CABIN. TOLD HER TO PREPARE FOR AN EVAC. ONCE WE STOPPED ACFT ON GROUND, SMOKE DISSAPATED. SMOKE COMING FROM SEAT 9A. R & R LIGHT ASSY AT SEAT 9A IAW/JIC 33-25-21 RAI 10000 OPTS CHECK GOSDR UALA2011092805247Lamp · inoperativeFWD LAVATORY DARK UNTIL LOCKED. RELAMPED FWD LAVATORY.SDR MASA2011092663746Light · inoperativeCELING FLOOD LIGHT INOP ROW 10. RELAMPED FLOOD LIGHT.SDR HYIA3249MSMOKEDimmer · failedPILOT REPORTED THAT DURING NIGHT TRAINING FLIGHT, THE ODOR OF SMOKE WAS NOTED IN THE CABIN. NOTED SMOKE COMING FROM OVERHEAD LIGHTS. PILOT PERFORMED "CABIN ELECTRICAL FIRE OR SMOKE" MEMORY ITEMS, CONTACTED ATC, AND LANDED WITHOUT INCIDENT. UPON INSPECTION, THSDR A6WA201140857Ballast · failedCABIN SMELLS OF ELECTRICAL SMOKE. ODOR IS STRONGER NEAR LAV. R & R LAV LIGHT BALLAST.SDR WX0A070936Ballast · defectiveFLIGHT CREW PERSONNEL REPORTED, HOT ELECTRICAL ODOR FROM FRONT LAV. MAINTENANCE DEPARTMENT PERSONNEL FOUND SMELL COMING FROM P4-32 BALLAST. REMOVED AND REPLACED LIGHT BALLAST, OPERATIONAL CHECK OF SYSTEM NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR CALA2011091600602Light · wrong partSTRONG BURNING RUBBER ODOR IN FLIGHT BETWEEN ROWS 12-16. CORRECTED DATE & STA TO 15 SEP 11 & IAD (16 SEP 11 & DCA ENTERED IN ERROR) PERFORMED FIM TASK 05-51-26-800-801C1 SMOKE / ODOR IN THE FLIGHT DECK/ CABIN CONDITIONAL INSPECTION. FOUND WRONG BULBS INSTALLSDR CA110916004Potentiometer · burned(CAN) ON CLIMB OUT CREW DETECTED A SMOKE/BURNING - SHORTLY AFTER CABIN FILLED WITH SMOKE. ACFT SHUT ELECTRIAL POWER OFF, SQUAWKED EMERGENCY ON TRANSPONDER AND LANDED WITH OUT INCIDENT.SDR RAIA201109130001Ballast · burnedDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED A BURNING SMELL IN CABIN BY ROW 12. MAINTENANCE INSPECTED AND DEFERRED THE SIDEWALL LIGHT AT 12A ON DMI 64446, MEL 33-20-00-2.SDR SWIA201127603Ballast · failedSMOKE SMELL IN CABIN. (FLT 5371) GALLEY LIGHT BALLAST BURNED UP WHEN IT FAILED. REPLACED AFT GALLEY LIGHT BALLAST.SDR QXEA2011091200813Light · odorELECTRICAL ODOR COMING FROM THE AFT GALLEY. REPLACED LT GALLEY LIGHTS, NO FURTHER DEFECTS FOUND. RETURNED TO SERVICE.SDR UALA2011090904888Module · faultyLIGHTS IN BACK ZONE OF ECONOMY WON'T COME ON. REPLACED ZMU NR 3 PER MM.SDR SWAA116431Light · damagedDECLARED EMERGENCY - RT OVERHEAD CEILING LIGHT BASE DAMAGED BY SHORTED WIRE BETWEEN ROW 6 TO ROW 7. REMOVED AND REPLACED LIGHT BASE PER MM.SDR C2XA11IA197Ballast · overheatedIAH - FLIGHT 2469, DURING POST FLIGHT THE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE CABIN. MAINTENANCE REMOVED AND REPLACED THE SIDEWALL BALLAST AT SEAT 3A/4A, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR UALA2011090504765Light · inoperativeLOCATION 421, BUSINESS AUX GALLEY, LIGHT ABOVE MOVEABLE BIN INOP. BULB REMOVED. FOUND ONE LAMP STILL INSTALLED, SOCKET BURNT AND LAMP WELDED TO SOCKET. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR WX0A070928Ballast · defectiveLIGHT SMOKE AND ELECTRICAL FUMES COMING FROM PSU 30AC. MX NOTE; DURING TROUBLESHOOTING FOUND SIDEWALL LIGHT BALLAST BURNT, NO OTHER DEFECTS NOTED. REMOVED AND REPLACED BALLAST ON ROW 30AC IAW AMM 33-21-03, OPS CHECK GOOD, AIRCRAFT RETURNED TO SERVICE.SDR FDEA201108313594Ballast · failedLIGHT OVER LEFT ENTRY DOOR COMES ON IF YOU CYCLE EMERGENCY LIGHT SWITCH IT GOES OFF. AFTER A PERIOD OF TIME COMES BCACK ON. TROUBLESHOT TO A BAD ENTRY DOOR LIGHT BALLAST. R & R ENTRY DOOR LEFT BALLAST IAW MM 33-32-01-2 AND SYS OPS. CHECKED NORMAL, ACFT OK SDR SWIA201127423Ballast · malfunctionedELECTRICAL SMOKE FILLED CABIN. (FLT 5330) REPLACED LIGHT FIXTURE AND LIGHT BALLAST AT 5A.SDR DALA1151019227Ballast · malfunctionedFLIGHT CREW REPORTED ELECTRICAL SMELL IN FORWARD GALLEY. TURNED OFF GALLEY POWER AND SMELL DISSIPATED. MAINTENANCE REPLACED FORWARD GALLEY OVERHEAD LIGHT BALLAST. OPERATION CHECKS GOOD.SDR CHQA201100354Socket · burnedCREW REPORTED AN ELECTRICAL BURNING SMELL COMING FROM ROW 4 DURING FLIGHT. THE AIRCRAFT LANDED WITHOUT INCIDENT AT ITS INTENDED DESTINATION, KPHL. MAINTENANCE FOUND THE LIGHT SOCKETS AT ROW 4, SEATS D AND F TO HAVE BURN MARKS. MAINTENANCE DISCONNECTED THE SSDR SIMA201124204Socket · out of positionON FLIGHT 3560 THE CREW REPORTED AN ODOR OF ELECTRICAL BURNING AND LIGHT SMOKE OBSERVED NEAR SEATS 4 B & C AND THE AFT GALLEY AREA. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPOSITIONED LATERAL LIGHT SOCKET AT ROW 4A-B/C. THE OPERATIONAL TEST CHECK WAS GOOD ISDR HNAA2011090100267Socket · crackedDURING TAXI, ELECTRIC SMELL IN CABIN AND FLIGHT DECK. OVERHEAD LIGHTS AND C/B'S ARE ACTIVATED. FOUND OVERHEAD POWER STRIP FIXED, END SOCKET CRACKED. R & R LIGHT STRIP AT ROW 2DF. OPS CHECKED GOOD. CABIN INTERIOR NORMAL LIGHTING SYS, COMPLIED WITH SPECIAL SDR UALA2011082604564Ballast · faultySMELL IN AFT GALLEY, FLIGHT DIVERTED. FOUND BAD COUNTER LIGHT BALLAST AND SOME BURNT DEBRIS ON COUNTER HOTPLATE. REMOVED DEBRIS FROM HOTPLATE AND REPLACE BALLAST. TALKED TO SAMC AND GOT OKAY.SDR IPXA11168941Light · inoperativeLAV AUX / MIRROR LIGHT INOPERATIVE. RELAMPED AND TESTED GOOD IAW MM 33-51-21-04.SDR TRBA201124102Socket · failedF/A REPORT ODOR OF SMOKE ON THE CABIN. REPLACED FLOURESCENT TUBE SOCKET 12AB IAW JIC 20-27-17, OPS CHECK FOUND SYS WORKING PROPERLY IAW WC EX-332000-OPT-10000-006.SDR 2011FA0000550Housing · arcedDURING DESCENT, THE F/A REPORTED A FAINT SMOKE OR ELECTRICAL ORDER AND FLICKERING LIGHTS IN THE GALLEY AREA. INSPECTED ON GROUND FOUND SIGNIFICANT DAMAGE TO A LIGHT ASSY DUE TO ELECTRICAL ARCING. NO RECENT MAINTENANCE HAS BEEN PREFORMED ON THE LIGHT ASSY. SDR UALA2011082404532Light · faultySMOKE OR FUMES IN CABIN - SOURCE UNKNOWN. CREW COMMENTS: ROWS 40 THRU 45 ON RIGHT SIDE OF CABIN HAS ELEC SMOKE SMELL. SAMC TEXT: FUMES CLEARED WITH IFE SWITCHED OFF AND CABIN LTS IN NIGHT MODE. CLEANED COFFEE WARMER, FOUND BURNT PLASTIC ON HOT PLATE AFT RISDR TRBA201123501Socket · burnedBURNING ODOR COMING FROM THE AIR CONDITIONING VENTS. R & R BURNED SOCKETS 294 LGB & 231 LGA. OPS CHECKED OK IAW JIC 33-21-23. NO BURNING ODOR NOTICE AT THIS TIME.SDR A6WA201140773Ballast · burnedBURNING ODOR IN CABIN BETWEEN ROWS 5-7. FOUND BALLAST ABOVE SEAT A/C BURNED (CTR AISLE LIGHT) R & R BALLAST IAW AMM 33-21-01. OPS CHECKED GOOD.SDR TRBA201123101Socket · damagedAFTER TAKEOFF A STRONG ELECTRICAL BURNING ODOR IN THE CABIN. R & R FLUORESCENT TUBE SOCKET FIN 295LG IAW JIC 20.00.00. OPS CK FOUND SYS WORKING PROPERLY IAW EX-3322000-OPT-006.SDR USAA2011081600045Ballast · smokeBOS - FLT 749 EN ROUTE MAD TO CLT. F/A REPORTED SMOKE/FUMES IN CABIN. DIVERTED TO BOS. AFTER TURNING OFF UTILITY/BUSES, CABIN STARTED CLEARING. ACCOMPLISHED CABIN AIR QUALITY CHECK. CHECKED C/B CKPT + EEBAY, RECIRC FANS GALLEYS AND LAVS AND DID VISUAL SE
Back to JASC 3320