JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200718983Light · burnedCAPTAIN REPORTS BURNING ODOR AND SMOKE IN CABIN. REPLACED CABIN LIGHT FIXTURE WITH A SERVICEABLE UNIT. OPS CHECKS GOOD.
SDR HNAA0800004Ballast · defectiveELECTRICAL SMELL IN CABIN, MORE NOTICEABLE AT ROW 7. PERFORMED HIDDEN DAMAGE INSPECTION, FOUND OVERHEAD LIGHT ASSEMBLY AT 7C BURNT. REPLACED LAMP HOLDER BV03300-12-150 AND BALLAST, OPERATIONAL CHECK GOOD.SDR SWIA200718929Inverter · inoperativeFLT 6681 - AFT FLOOR LEVEL LIGHT STRIP IS INOP. REPLACED AFT INVERTER. OPS CHECK GOOD.
SDR COMA0760709Light · burnedFLIGHT 5377 - NOTICED ELECTRICAL SMELL AND LIGHT SMOKE IN COCKPIT. REPLACED GALLEY LIGHT ASSEMBLY. NO FURTHER DEFECTS.SDR 2007UALA04979Ballast · failedRTFL DUE TO SMOKE IN AFT GALLEY. FOUND FAILED BALLAST. REPLACED BALLAST.SDR TRBA2007107Bulb · burned outBURNING ODORIN FWD PORTION OF CABIN. FOUND LIGHT BULBS BURNT AT ROW 1AB AND 6CD. REMOVED LIGHT BULBS (CEILING) IAW ATR72 JIC 33-10-00.SDR SIMA200733209Ballast · malfunctionedSTRONG PLASTIC MELTING OR BURNING SMELL COMING FROM GALLEY AREA. FOUND BALLAST OVER GALLEY GOING OUT REMOVED AND REPLACED BALLAST IAW EMB AMM 33-28-07. OPS CHECK GOOD, AIRCRAFT RETURNED TO SERVICE.
SDR K5L2007F00002Power Supply · failedAWAITING TAKEOFF, PILOT TURNED ON CABIN LIGHTS AND NOTICED SMOKE FUMES IN COCKPIT AND CABIN. TURNED OFF VENT BLOWED AND CABIN LIGHTS AND RETURNED TO RAMP. IT WAS DETERMINED THAT THE POWER SUPPLY (BALLAST) HAD FAILED AND CAUSED THE SMOKE. POWER SUPPLY WAS RESDR NWAA073825816Ballast · smokeDURING FLIGHT THE LAV AT DOOR 3 LEFT A PASSENGER NOTICED THAT THE LIGHTS FLICKERED AND WENT OUT. THIS WAS FOLLOWED BY SOME SMOKE FROM OVERHEAD THE SMELL OF BURNING PLASTIC. FLIGHT CONTINUED ON AND LANDING WAS UNEVENTFUL. MAINTENANCE REMOVED AND REPLACED LAVSDR HNAA0700273Socket · burnedSTRONG ELECTRICAL ODOR IN CABIN WITH SMOKE. INSPECTED CABIN AND FOUND THE OVERHEAD LIGHT AT ROW 8DF LIGHT SOCKET BURNT. PERFORMED HIDDEN DAMAGE INSPECTION NO OTHER DAMAGE NOTED. REPLACED LAMP HOLDER SOCKET.SDR 2007UALA04723Wire · burnedCREW REPORTED AN ELECTRICAL ODOR FROM REAR GALLEY AREA. RECIRC FANS AND GALLEY POWER TURNED OFF AND ODOR DISSIPATED. GALLEY AREA CHECKED AND NO OBVIOUS FAULTS FOUND. CHECKED FOR ODOR IN GALLEY CEILING AREA, UNDER FLOOR AND CHECKED WIRING IN AREA AND NO FAUSDR YENA2007100Light · inoperativeFLT 309, IAD-SAN, APPROX BETWEEN 13:30Z-15:09Z SEAT 12E READING LIGHT OUT. PAX OBSERVED SMOKE AS LIGHT WENT OUT. REMOVED OVERHEAD PANEL 12 DEF, INSP WIRING AND CIRCUIT BOARD, FOUND NO EVIDENCE OF ELECT BURNING, RESECURED PANEL. RE-SET CIDS, PERFORMED OPERATSDR 2007UALA04712Light · shortedBC GALLEY WHEN CEILING LIGHTS ARE TURNED ON SMOKE AND ELECT ODOR IS PRESENT. FOUND SHORTED LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR DL764071513Lamp · inoperativeRI DOOR SLIDE LIGHT INOP. RELAMP LIGHT INDICATOR IAW DALB767-400 MM 33-13-00. OPS CHECK GOOD IAW DAL B767-400 MM 52-73-00 STEP E1-E9.SDR DL764071514Light · inoperativeSLIDE LIGHT AT 1L DOOR INTERMITENT. RELAMP SLIDE LIGHT IAW DAL B767-400 33-13-00. OPS CHECK GOOD IAW B767-400 MM 52-73-00 STEP E1-E9.SDR SIMA200731804Ballast · smokeABOUT 500' AFTER TAKEOFF 'LAV SMOKE' WARNING ILLUMINATED. WARNING LIGHT WENT OFF ON FINAL APPROACH, FA REPORTED SMOKE IN CABIN. TOUCHDOWN WAS SOFT. REMOVE AND REPLACED BOTH LAVATORY BALLAST IAW 140 AMM 33-28-02. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICSDR A6WA200740613Ballast · faultyELECTRICAL SMOKE ODOR IN AREA OF ROW 3, AT GATE NO PASSENGERS ONBOARD. IDENTIFIED BAD BALLAST FOR 4DF CEILING LIGHT. REMOVED AND REPLACED CEILING LIGHT 4DF POWER UNIT/DIMMER (111B) IAW CRJ200 AMM 33-21-04. OPS CHECK GOOD. (M)SDR AALA20072168Light · misinstalledMIA INFLIGHT T2160/08NOV - FLIGHT ATTENDANTS REPORTED FIRE IN OVERHEAD ROW 11. FLIGHT ATTENDANTS USED HALON EXTINGUISHER WHICH CREATED SMOKE IN CABIN. AIRCRAFT RETURNED TO MIA AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND FLUORESCENT LIGHT AT RIGHT SEAT RSDR 2007FA0001000Power Supply · burnedDISCREPANCY WAS CABIN INDIRECT LIGHTING IS INTERMITTENT. FOUND SHORTED WIRING AT AFT LT SIDE VALANCE, 2 BURNED POWER SUPPLIES AND SEVERAL CRACKED LAMP FIXTURES. CUSTOMER STATED THIS IS THE 3RD TIME THE POWER SUPPLIES WERE FOUND BURNED.SDR HNAA0700256Ballast · defectiveTHE FLIGHT ATTENDANT REPORTS ELECTRICAL BURNING SMELL IN CABIN. AIRCRAFT RETURNED TO GATE AND THE LIGHTS WERE DEACTIVATED. A HIDDEN DAMAGE INSPECTION WAS PERFORMED AND REMOVED BULB FROM THE SIDE WALL LIGHT AT ROW 7AC. THE BALLAST AND BULB HOLDER WERE REPLACSDR SMIA200730201Ballast · failedSTRONG ELECTRICAL BURNING ODOR DURING TAXI. CREW RETURNED TO GATE. REMOVED AND REPLACED BALLAST AT SEAT 1A IAW EMB 145 AMM 33-12-03. OPERATIONAL CHECK GOOD IAW EMB145 AMM 33-21-50. AIRCRAFT RETURNED TO SERVICE.SDR C2XA07RI092Ballast · defectiveFLT 2322 - EWR - DURING TAXIING OUT OF THE GATE, CREW REPORTED A BURNING ODOR IN CABIN AND GALLEY AREA. CREW RETURNED TO GATE AND EWR MX FOUND BALLAST IN GALLEY AREA DEFECTIVE. MX REMOVED AND REPLACED BALLAST IN GALLEY AREA AND PERFORMED OPERATIONAL TEST SUCSDR SIMA200729503Ballast · failedSLIGHT ODOR COMING FROM CABIN CEILING LIGHTS. FLIGHT ATTENDANT SAID WHEN DIMMED THE LIGHTS ROW 2 AND ONE LIGHT WENT FULL BRIGHT. THAT IS WHEN SMELL STARTED. NO SMOKE. REMOVED BULB AT ROW 2 AND ISSUED MEL 33-02. REMOVE AND REPLACE CARGO LIGHT BALLAST AT SESDR SIMA200728901Psu · odorPASSENGER SERVICE UNIT LIGHTS FLICKERED DURING TAXI FOLLOWED BY ELECTRICAL ODOR IN CABIN AND COCKPIT. REMOVED AND REPLACED PASSENGER SERVICE UNIT ASSY PER AMM 25-22-05. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE.SDR C2XA07IA223Light · burnedIAH - FLIGHT 2481, ON POST FLIGHT INSPECTION THE CREW REPORTED AN ELECTRICAL ODOR IN THE CABIN. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE LIGHT ASSEMBLY ABOVE SEAT 6A, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED SDR SIMA200728303Fixture · odorON TAXI IN, PAX AND FLIGHT ATTENDANT NOTICED A BURNING ODOR AROUND ROW 3. REMOVED AND REPLACED LIGHTNING FIXTURE IAW AMM 33-21-06. MEL RESTORED. AIRCRAFT RETURNED TO SERVICE.SDR HNAA0700213Light · odorELECTRICAL BURNING ODOR NOTICED IN AFT CABIN AREA, REQUESTED MDT MAINTNANCE FOR HELP. SWAPPED 804EX WITH 807EX REMOVED AND REPLACED OVERHEAD LIGHT ASSY ABOVE SEAT POSITION 2AC, OPS CHECK GOOD. OK FOR SERVICE IAW 33-25-00. MORE TO FOLLOW.SDR WRLA2007103Ballast · failedEDDP/OKBK ROW 10 & 11 SEATS A, B & C OVERHEAD CEILING LIGHT ABOVE & BEHIND LUGGAGE BIN WAS HOT WITH BURNING PLASTIC ODOR LIGHT WAS DISCONNECTED. 10-18-07 R & R BALLAST.SDR DLM90071294Ballast · shortedFLT ATTENDANT REPORT STRONG ODOR OF SMOKE LIKE MATCH BEING LIT BETWEEN 19-25. NOR VISUAL IND OF SMOKE. IT DISSIPATED AFTER 5 MIN. NO ABNORMAL INDICATIONS NO SMOKE DETECTOR ALARMS. OP VIDEO SYS, CKS NML O2 GENERATORS AND VDUS INSP. INSPECTED BATTERY PACKS SDR 74509272007Relay · failedODOR OF BURNING INSULATION DETECTED IN CABIN. NO SMOKE PRESENT. CHECKED FOR TRIPPED CIRCUIT BREAKERS. NONE FOUND. RECYCLED/RESET BOTH GENERATORS TO CHECK LOAD ON EACH. NO PROBLEMS DETECTED AND RESTORED BOTH GENERATORS. CONTINUED TO FINAL LANDING AT BASE SDR TRBA2007081Ballast · failedFLIGHT ATTENDANT ADVISED OF ELECTRICAL BURNING ODOR ON TAKEOFF. REPLACED BURNED CEILING LIGHT BALLAST CONVERTER PER JIC 32-21-21 ON SEAT 9/10CD. PERFORMED ENGINE RUN-UP AND FOUND AC ACW AND DC ELECTRICAL SYSTEM WORKING PROPERLY, NO BURNING ODOR NOTICED PER MSDR HNAA0700173Psu · hotBURNING ODOR AT AFT CABIN, NOTICED BY CREW MEMBERS & AFT F/A CONTROL PANEL APPEARS TO BE HOT TO TOUCH. INSPECTED F/A PANEL NO DEFECT NOTED CREW GROUND RAN AIRCRAFT WITH BLEEDS ON, NO ABNORMAL ODOR NOTED. DEACTIVATED PSU AT 8DF DUE TO INTERMIT CHIM ACTIVATIONSDR SWAA074645Lens · contaminatedDECLARED EMERGENCY, FLIGHT ATTENDANT SAW SMOKE FROM READING LIGHT AT ROW 22F. FOUND READING LIGHT BULB AND LENS SOILED WITH CANDY. REMOVED AND REPLACED LIGHT BULB AND LENS PER MM.SDR 2007UALA03738Ballast · faultyFWD GALLEY OVERHEAD LIGHT EMITTED ODOR WHILE ON BUT WENT AWAY. LEFT IT OFF FOR REMAINDER OF FLIGHT. 10-9-07 REPLACED BALLAST M660, OP CHECKS OK.FOR SERVICE.SDR C2XA07RI082Light · defectiveFLT 2754 - YOW - CREW REPORTED ELECTRICAL ODOR FROM SEAT 1A AREA. MX FOUND FLUORESCENT LIGHT ARCING AT CONTACT. MX REMOVED AND REPLACED LIGHT ASSEMBLY AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR DL764071184Bulb · burned outLIGHT/BRIEF ODOR OF SMOKE NOTICED AROUND SEATS 23A/B. THIS OCCURED AT 3.5 AND 7 HRS INTO FLIGHT AT CRUISE. NO VISIBLE SMOKE SEEN OR DETECTED. F/A'S REPORT SLIGHT ODOR OF BURNING MATCH, CAR BACKFIRE, RUBBER. FOUND SEAT 21A READING LIGHT BURNED OUT. REPLACEDSDR SIMA200725305Bulb · odorELECTRICAL BURNING SMELL AT ROWS 6 AND 7A. REMOVED AND REPLACED WINDOW SIDE LIGHT BULBS IAW AMM 33-20-00. OPS CHECK OK. AIRCRAFT RETURN TO SERVICE.SDR 200725305Bulb · odorELECTRICAL BURNING ODOR AT ROWS 6 AND 7A. REMOVED AND REPLACED WINDOW SIDE LIGHT BULBS IAW AMM 33-20-00, OPS CHECK OK.SDR C2XA07IA192Ballast · defectiveIAH - FLIGHT 2857, THE CREW REPORTED THAT THE BALLAST ABOVE SEAT 4A SMELLED BURNT. MAINTENANCE INSPECTED THE AIRCRAFT, AND PLACED THE LIGHTING IN MEL 33-210-00/1 CAT C CONTROL 128447, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. THE AIRCRAFT RETURNEDSDR SIMA200724701Ballast · burnedBURNED SMOKE ODOR IN CABIN. REMOVED AND REPLACED ROW 3A LIGHTING BALLAST IAW EMB AMM 33-21-03. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR CA070827004Ballast · burned(CAN) CREW REPORTED WHEN THEY APPLIED EXT AC POWER TO THE AIRCRAFT AND TURNED ON THE SWITCH IN THE COCKPIT, THEY COULD SMELL SOMETHING BURNING AND SAW A BLUE HAZE IN THE AIR. THEY IMMEDIATELY TURNED POWER OFF AND CALLED MAINTENANCE CONTROL. MAINTENANCE INSPECSDR CHQA200700041Ballast · burned outJFK TO IND JUST AFTER LIFT OFF RECEIVED THE "LAV SMOKE" WARNING. FA CHECKED FOR SMOKE OR FIRE AND NOTICED A HOT ELECTRICAL BURNING SMELL IN THE REAR OF THE CABIN. THE SMELL QUICKLY DISSIPATED. FLIGHT CREW DECLARED AN EMERGENCY AND RAN THROUGH THE APPROPRIATSDR 2007UALA03208Unknown · unknownCABIN LIGHTS FLICKER AND EMERGENCY LIGHT RIGHT SIDE WINDOW INTERMITTENT. CYCLING SWITCH DIDN`T FIX. CREW REPORTING LIGHTS FLICKING THROUGHOUT CABIN ON BOTH LT AND RT SIDES WITH RESET NO HELP, AND FLT ATTENDANT STATED APPEARED TO BE FLASHING WITH SPEED CHANGESDR CALA0700439Ballast · malfunctionedSMOKE WITH AN ELECTRICAL ODOR WAS NOTED BY F/A'S IN AREA OF MID GALLEY WHILE AT CRUISE PORTION OF FLIGHT. BOTH UTILITY BUSSES WERE DEACTIVATED AND THE SMOKE STOPPED. THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. MAINTENANCE INSPECTED THE MID GALLEY AREASDR SIMA200722204Ballast · burnedELECTRICAL ODOR IN CABIN AT SEAT 1A. FOUND BALLAST RT8425 AND RT8400 BURNED. REMOVED AND REPLACED BALLAST IAW EMB AMM 33-21-03. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR SWIA200718568Ballast · odorFLIGHT NR 3968, FLIGHT ATTENDANT SMELLED ELECTRICAL SMOKE NEAR AN OVERHEAD BIN. REPLACED SIDEWALL LIGHT BALLAST IAW 33-21-10. OPS CHECKED GOOD.SDR SIMA200721402Control Module · burnedBURNING ODOR FROM GALLEY AREA. REMOVED AND REPLACED LIGHT BALLAST IAW EMB AMM 33-21-05 AND REMOVED AND REPLACED CONTROL MODULE ASSEMBLY IAW EMB AMM 33-21-01, BOTH COMPONENTS OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR CA070801006Light · overheated(CAN) CABIN OVERHEAD FLOURESCENT LIGHTING FIXTURE OVERHEATED. BURNED OUT BULB FOUND AND CONTACTS IN FIXTURE THAT CONDUCT ELECTRICITY TO BULB FOUND LOOSE AND OVERHEATED, CAUSING PLASTIC PART OF ASSY TO OVERHEAT. PARTS REPLACED AND A/C RELEASED TO SERVICE WITHOSDR FDKA200707339Ballast · malfunctionedFDM 6023 JFK-BWI (1544 PHX LCL) - CAPTAIN REPORTED BURNING SMELL IN REAR CABIN. REMOVED AND REPLACED ROW 7DF SIDEWALL BALLAST AND OPS CHECKED GOOD.SDR MASA2007427Light · inoperativeASH 7121 MDT. MID CABIN EMERGENCY CALL LIGHT INOP. MX RELAMPED LIGHT.
Back to JASC 3320