JASC 3320
Service difficulty reports · 2,973
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MASA2007427Light · inoperativeASH 7121 MDT. MID CABIN EMERGENCY CALL LIGHT INOP. MX RELAMPED LIGHT.SDR 2007UALA02660Ballast · overheatedLAV 100 MIRROR LIGHT ASSY SHOWED SIGNS OF OVERHEATING. [08-07-07] REPLACED LIGHT ASSY AND BALLAST. OP CK GOOD.SDR 2007UALA02538Light · fireSMOKE ODOR DOWNSTAIRS AND THEN FIRE FORWARD OF UPPER DECK GALLEY IN THE CEILING. ONE HALON EXTINGUISHER FIRED. [08-08-07] FOUND FLUORESCENT LITE SOCKETS WITH HEAT DAMAGE. REPLACED UPPER DECK CEILING FLUORESCENT LIGHT SOCKETS. ALSO REPLACED BALLAST. ALLSDR TRBA2007042Light · burned outDURING DEPLANING THE LAST PAX AND F/O SAW AND SMELLED SMOKE ABOVE THE OVERHEAD BIN AT PAX SEAT 7AB. THE BURN MARKS ARE VISIBLE ON THE UPPER PART OF THE OVERHEAD BIN DOOR. REMOVED FLUORESCENT TUBE AT ROW 7AB IAW JIC NR 33-21-23 AND ITEM DEFERRED ON MEL 33-02 SDR ASAA0771844Socket · meltedBURNING SMELL AT ROW 21 RT SIDE OF AIRCRAFT WITH NIGHT LIGHT TURNED ON. SMELL NO LONGER PRESENT WITH NIGHT LIGHT TURNED OFF. FOUND NIGHT LIGHT SOCKET MELTED AT ROW 21R. REPLACED SOCKET ASSY. SYSTEM OPS OK.SDR ASAA0751826Light · odorELECTRICAL TYPE SMELL IN CABIN DURING FLIGHT. F/A'S REPORT MOST NOTICEABLE AT ROWS 9, 11 AND NEAR AFT GALLEY VENT. SLIGHTLY NOTICEABLE IN COCKPIT. TURNED OFF CABIN LIGHTING AND SMELL DISSIPATED. CHECKED AFT GALLEY OVENS COFFEEMAKERS HOT PLATES FOR DEBRIS NSDR C2XA07IA143Light · shortedIAH - FLIGHT 2091, DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL AT ROW 3A. MAINTENANCE REMOVED AND REPLACED THE SIDEWALL LIGHT ASSY, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR QXEA200700963Lens · dislodgedSEA FLIGHT NR 2026 PLASTIC PIECE FELL OFF FROM CEILING ABOUT 6" LONG. REPORTED BY FLIGHT ATTENDANT. MAINTENANCE RESECURED SIDE WALL LIGHT LENS. PERFORMED GUI OF LENS. NO DEFECT NOTED. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.SDR NOCA13307Ballast · sparksF/A COMPLAINED THAT A SPARK FELL OUT THE FRONT GALLEY FROM THE TOP CEILING AREA. REMOVED AND REPLACED BALLAST M660 PER WDM 33-22-11, ALL OPS OK. AS PRECAUTION INSPECTED ABOVE GALLEY CEILING AREA FOR ANY CHAFED WIRES, BURNED SMELL. NO FAULTS FOUND. PERFORMESDR SWAA072982Light · faultyF/A REPORTED BURNING SMELL FROM OVERHEAD CABIN LIGHT AT ROW 19 DEF. REMOVED AND REPLACED LIGHT BALLAST AND LIGHT ASSY PER MM.SDR DL76L070715Switch · brokenCREW REPORTS CABIN OVERHEAD LIGHTS FLICKERING ON AND OFF THROUGH ENTIRE CABIN. PULLED C/BS ON P-33 PANEL TO STOP FLASHING RETURNED TO JFK FOR REPAIRS AFTER ISOLATED PROX BOX FAULTS CARD 06. REPLACED PSEU. OPS OK. FND SW S 527 P19 BROKEN. INSPECTED RT GEN SDR C2XA07IA141Light · malfunctionedIAH - FLIGHT 2830, THE CREW REPORTED THAT THE READING LIGHT AT SEAT 5A FLICKERED ON AND OFF AND CREATED SMOKE. THE F/A PUSHED THE RESET BUTTON AND THE LIGHT WOULD NOT TURN OFF. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AFFECSDR GUUA06080701Lamp · inoperativeAT SCHEDULED INSPECTION, DETERMINED EMERGENCY LIGHT ABOVE ROW SIX TO BE INOPERATIVE. REPLACED LAMP.SDR BAQA200700015Dimmer · burned outIN CRUISE FLIGHT MEDICAL CREW REPORTED A DIMMING OF THE CABIN FLOOD LIGHTING FOLLOWED BY AN "ELECTRICAL BURNING SMELL".SDR MWEA070121Ballast · inoperativeFLIGHT ATTENDANT REPORTED STRANGE SMELL & LIGHT HAZE. REMOVED AND REPLACED BALLEST AT ROW 21.SDR C2XA07IA121Light · burnedIAH - FLIGHT 2008, THE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE COCKPIT ON DESCENT, AN EMEREGENCY WAS DECLARED, AND THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE SIDEWALL LIGHT AT SEAT 7A. SDR 2007Ballast · defectiveFLIGHT ATTENDANT REPORTED A ELECTRICAL ODOR IN FRONT OF CABIN. REMOVED AND REPLACED GALLEY CEILING LIGHT BALLAST IAW EMB MM. OPS CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR 200714202Ballast · blownFLIGHT ATTENDANT REPORTED ELECTRICAL SMELL IN FRONT OF CABIN. REMOVED AND REPLACED GALLEY AREA CEILING LIGHT BALLAST IAW EMB AMM. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR 200714201Bulb · brokenFLIGHT ATTENDANT NOTICED RUBBER BURNING SMELL FROM AROUND ROW 17. REMOVED AND REPLACED BROKEN CEILING LIGHT BULB IAW CRJ AMM. OPS CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR HNAA0700083Socket · burnedELECTRICAL ODOR NOTICED AT ROW 3 RIGHT HAND SIDE. PERFORMED HIDDEN DAMAGE INSPECTION, REPLACED LIGHT SOCKET AT 3 AC, OPS CHECK GOOD.SDR C2XA07IA100Ballast · burnedHRL - FLIGHT 2002, DURING PREFLIGHT INSPECTION THE CREW REPORTED A POSSIBLE BURNING SMELL IN THE GALLEY WHEN THE AIRCRAFT WAS POWERED UP. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE CABIN LIGHT BALLAST A SEAT 1A TO BE BURNT. THE BALLAST WAS DISCONNECTEDSDR 2007UALA01320Lamp · inoperativeLAVS SYSTEM 2 LIGHTS CB POPPED AGAIN. REPEAT GRIPE. FOUND PROBLEM ISOLATED TO AFT CABIN LAVS. CK'D ALL DR SWITCHES AND HANDICAPPED LIGHT SWITCH. ALL CHECKED GOOD. FOUND "OCCUPIED" SIDE OF LAV OCCUPIED SIGN LIGHT BULBS SHORTED. RELAMPED, CKS GOOD. OK FOR RETSDR HNAA0700066Light · malfunctionedON TAXI OUT - F/A REPORTED SMOKE COMING FROM AIRSTAIR DOOR STEP LIGHTS (MIDDLE 2 LIGHTS).SDR SIMA200709901Light · shortedBURNING ODOR NOTICED ON LANDING COMING FROM AROUND THE MAIN DOOR AREA. INSPECTED AREA AND FOUND LIGHT ABOVE SEAT 3A SHORTED OUT. REMOVED THE BULB AND DEFERRED PER MEL 33-02.SDR 070090Ballast · odorFLIGHT 452 LAS/ICT, THE FLIGHT CREW REPORTED THAT A FLIGHT ATTENDANT REPORTED A STRONG ELECTRICAL SMELL IN FLIGHT BETWEEN ROW 10 AND 11 (LEFT). PASSENGER SERVICE PANEL AND OVERHEAD STOWAGE BIN IMMEDIATELY ABOVE FELT WARM. PHASE OF FLIGHT ASSUMED TO BE CRUISESDR CIEA200700002Resistor · burnedSHUTDOWN THE ENGINES, NOTICED LIGHT SMOKE COMING FROM UNDER INSTRUMENT PANEL & AN ODOR LIKE ELECTRICAL BURNING. MAINT INSPECTED AC & WHEN MASTER SWITCH WAS TURNED ON, A RESISTOR MOUNTED TO FWD BULKHEAD UNDER PILOTS INSTRUMENT PANEL FOUND TO BE GLOWING RED & ESDR DXTA200702080Light · odorOVERHEAD LIGHTS IN LAV ARE INTERMITTENT. AFTER TURNING LIGHTS ON AND OFF SEVERAL TIMES A BURNING ODOR WAS NOTED. REMOVED RT AND LT OVERHEAD LIGHT PANELS IN LAV. INSPECTED LIGHT AND BALLAST ASSY. FOUND R/H TOP LIGHT TO BE BURNT AND PLASTIC END MELTED. REMOVEDSDR QXEA200700447Cover · dislodgedPDX FLIGHT NR 2248, DURING TAXI OUT, PLASTIC LIGHT COVER FELL DOWN. MAINTENANCE REINSTALLED PLASTIC LIGHT COVER. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.SDR HNAA0700051Ballast · defectiveSMOKE COMING FROM AROUND RIGHT FWD FILLER PANEL ABOVE EMERGENCY EXIT DOOR. TROUBLESHOT TO SHORTED BALLAST ON RIGHT FORWARD FILLER PANEL PERFORMED HIDDEN DAMAGE INSPECTION NO DEFECTS NOTED. REPLACED BALLAST ASSEMBLIES (2).SDR VNAA0703016Light · odorCREW REPORTED A STRONG ELECTRICAL ODOR COMING FROM THE LAVATORY AREA. MAINTENANCE INSPECTED THE LAV AND SURROUNDING AREA INCLUDING OPS TESTING THE LAV LIGHT IN ACCORDANCE WITH THE AIRCRAFT MAINTENANCE MANUAL. OPS TEST GOOD, NO DEFECTS NOTED AT THIS TIME. MASDR SWIA200718058Ballast · failedFOUND SMOKE IN THE CABIN WITH LIGHTS FLICKERING AT ROWS 2 AND 3 AB SIDE. REPLACED LIGHT BALLAST AT ROW 3. OPERATIONAL CHECKS GOOD.SDR SIMA200707805Ballast · failedSEVERAL OVERHEAD CABIN LIGHTS INOPERATIVE ABOVE ROWS 16 AND 17A, SMOKE SMELL REPORTED. REMOVED AND REPLACED BALLAST FOR CEILING LIGHTS AT 16 AND 17A IAW EMB AMM 33-21-00. OPERATIONAL CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR CA070315002Socket · burned(CAN) REF LOG PAGE NR 593976. F/A REPORTS ELECTRICAL SMELL IN FORWARD CABIN, AROUND ROW 2 AND 3. 4FD SIDEWALL LIGHT HOLDER FOUND AT FAULT, CBP2 C/B S5 OPENED AND SECURED. SIDEWALL LIGHT INOP, DEFERRED IAW MEL 33-21-01 CAT (C). SOCKET ASSY P/N BB1-0020-02-58 (SDR CA070313003Power Supply · overheated(CAN) DURING CRUISE, FLIGHT CREW OBSERVED WHAT APPEARED TO BE WHITE SMOKE EMANATING FROM READING LIGHT (PSU) PANEL ASSEMBLY ABOVE SEAT 30 AB. CREW SWITCHED OFF READING LIGHTS AND SMOKE STOPPED. ON ARRIVAL TO THE STATION, MAINTENANCE FOUND ONE TRANSFORMER PRINTSDR MASA200700141Socket · burnedASH 2800 BUR - AIRCRAFT DIVERTED WAS EN ROUTE FROM BUR TO LAS WHEN THE SMOKE FORMED IN THE COCKPIT. MX FOUND GALLEY LIGHT SOCKET BURNED AND PLACED ON DEFERRAL. CREW PULLED CVR AND FDR CIRCUIT BREAKERS.SDR SWAA071019Light · shortedSPARKS FROM FWD GALLEY POWER PANEL. FOUND GALLEY POWER LIGHT ASSY SHORTED. REMOVED AND REPLACED LIGHT ASSY PER MM.SDR TRBA2007006Light · burned outWHILE IN TAXI, NR2 F/A REPORTED ELECTRICAL SMOKE SMELL. AC RETURNED TO STTFOR CHECK. REPLACED FLUORESCENT LIGHT BULB AND FOUND IT WORKING PROPERLY IAW MM 33-21-23. (K)SDR DL777070121Electronic Unit · inoperativeWORK LIGHTS INOPERATIVE AT 3L/3R. OEU M23406 AT 3R DOOR FAILED ON CABIN ALL TEST. FOUND OEU SHOWS EVIDENCE OF BURN MARK. REMOVED AND REPLACED OEU. COULD NOT COMPLETE SOFTWARE UPLOAD. FWD OEU SOFTWARE LOAD TOMCO AND PLAC PER MEL 25-20-01I. LOADED CONFIG ASDR HNAA0700232Psu · burnedFLIGHT ATTENDANT NOTICED SMOKE COMING FROM AROUND PSU AT 2AC. FOUND CIRCUIT CARD BURNED, REMOVED AND REPLACED PSU AT 2AC.SDR SIMA200703001Ballast · failedELECTRICAL SMELL IN CABIN AFTER OVERHEAD LIGHTS SELECTED OFF. REMOVED AND REPLACED BALLAST AT LEFT GALLEY AND ROW ONE IAW EMB AMM 33-21-03. OPERATIONAL CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR SWAA070340Light · faultyCABIN REPORTED SMOKE, ELECTRICAL SMELL ON GROUND. SECURED CABIN CEILING LIGHTS SMOKE SMELL DISSIPATED. INSPECTED CABIN LIGHTS, RT AND LT PACKS, RAN GASPER AND RECIRC FANS, NO FAULTS NOTED. REMOVED AND REPLACED AFT GALLEY WORK LIGHT BULBS PER MM.SDR 2007UALA00166Relay · faultyAFT GALLEY LTS, WINDOW AND SIDEWALL LIGHTING WHEEL WELL LIGHTS, WING ILLUMINATION LIGHTS AND EMERGENCY EXIT LIGHTS ARE INOPERATIVE ON APU GENERATOR AND ENGINE GENERATOR POWER. ALSO, THE NORMAL EQUIPMENT COOLING FAN IS INOP. EXCEPT WHEN EXTERNAL POWER IS CONNSDR SWIA200717686Bulb · overheatedELECTRICAL SMELL AT ROW 7 IN CABIN. REPLACED CABIN OVERHEAD BULBS AT ROW 7. OPERATIONAL CHECKS GOOD.SDR HNAA0600221Carrier Assy · burnedELECTICAL BURNING ODOR AT ROW 9 LEFT SIDE, CREW FOUND SIDEWALL LIGHT SOCKET BURNED. REPLACED LAMP CARRIER.SDR CA070106001Receptacle · faulty(CAN) DURING CLIMBOUT PASSENGER ALERTED FA TO SMOKE SMELL IN REAR OF CABIN , SMOKE WAS THEN VISIBLY OBSERVED BY PASSENGERS AND FA. FLIGHT RETURNED TO DEPARTURE AIRPORT AND ERS WAS REQUESTED. AIRCRAFT WAS APPROX. 2000 LBS OVERWEIGHT BUT LANDED AND TAXIED TO THESDR CA061229002Receptacle · damaged(CAN) DURING CLIMB, PASSENGER ALERTED FA TO SMOKE SMELL IN REAR OF CABIN. SMOKE WAS THEN VISIBLY OBSERVED BY PASSENGERS AND FA. FLIGHT RETURNED TO DEPARTURE AIRPORT AND ERS WAS REQUESTED. AIRCRAFT WAS APPROX 2000 LBS OVERWEIGHT BUT LANDED AND TAXIED TO THE GATSDR HNAA0600211Socket · burnedFOUND SOCKET FOR OVERHEAD LIGHT AT SEAT 4AC BURNED. REPLACED SOCKET.SDR COMA0660730Relay · faultyFLIGHT 5681 - EN ROUTE ACY - MCO, F/A REPORTED SMELL OF SMOKE IN CABIN NEAR 4A/B, FLIGHT DIVERTED TO ORF. REPLACED SIDEWALL LIGHT RELAY R102.SDR SIMA200635403Socket · damagedELECTRICAL BURNING SMELL NOTED IN CABIN AROUND ROW 6. RETURNED TO GATE. REMOVED AND REPLACED WALL LIGHT SOCKET, REPAIRED WIRE IAW EMB AMM 33-21-06. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR SWIA200617442Ballast · odorELECTRICAL SMELL COMING FROM ROW 2 LEFT SIDE OVERHEADS. REMOVED AND REPLACED LT ROW 2 CEILING BALLAST IAW 35-21-03. OPS CHECK GOOD.
Back to JASC 3320