JASC 3320
Service difficulty reports · 2,973
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA060628004Socket · overheated(CAN) LAMP SOCKET P/N BVO3202-04-114 OVERHEATED AND SMOKE SMELL NOTED AT R/H CABIN SIDE WINDOW LIGHT. LAMP SOCKET REPLACED. TESTED SERVICEABLE. (TC# 20060628004)SDR SIMA200617704Ballast · defectiveFLIGHT ATTENDANT SMELLED BURNING SMOKE SMELL AROUND FONT CLOSET, EXIT SIGN VERY HOT. MAINTENANCE FOUND FORWARD BALLAST IN LAV VERY HOT AND HAD SOME TYPE OF SMELL, REPLACED BALLAST ASSY. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR SIMA200617702Ballast · defectiveORD - FLT 3968 - FLIGHT CREW REPORTS ELECTRIC SMELL IN AFT PASSENGER CABIN. REPLACED TWO CEILING LIGHT BALLAST. OPS CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR HNAA0600055Socket · burnedELECTRICAL SMELL IN CABIN. FOUND LIGHT SOCKET AT 2D BURNED. C/W MP&P VOL 2 33.1SDR DLM90060487Ballast · burnedSMOKE COMING OUT OF PSU UNIT 26 CDE FOR 2 MINUTES, SMOKE THEN DISSIPATED. FOUND ONE SIDEWALL FLUORESCENT LAMP INOP AT ROW 26R. REMOVED PANEL AND INSPECTED SAME. RISIDUAL SMELL PRESENT WITH NO OTHER PROBLEMS FOUND. SUSPECT LIGHT BALLAST. FWD TO MCO AND PLASDR C2XA06TY035Light · burnedCLT, FLIGHT ATTENDANT REPORTED SMOKE IN CABIN, ELECTRICAL ODOR, CREW DID AN AIR RETURN, OVERWEIGHT LANDING, NORMAL LANDING AND ROLL OUT. MAINTENANCE FOUND SOURCE OF SMOKE AND ELECTRICAL ODOR TO BE COMING FROM THE READING LIGHTS AT SEATS 6A AND 7A, MAINTENANCESDR MASA200601566Socket · defectiveASH 6326 PHX - OVERHEAD LIGHTING FLICKERING AND SMOKE AT ROW 5 C AND D. MX REPLACED LAMP SOCKET.SDR QXEA200601418Socket · corrodedSEA - FLIGHT 2412: F/A ADVISED A ELECTRICAL SMELL TOWARD THE BACK 1/3 OF THE CABIN PRIOR TO PUSHBACK. MAINTENANCE FOUND AFT CARGO CEILING COMPARTMENT LIGHT BURNT OUT, SOCKET CORRODED. CLEANED SOCKET AND RELAMPED. OPS CHECK GOOD. INSPECTED ALL CABIN INTERISDR DL757060477Power Supply · burnedAFTER LEVEL OFF THE F/A CALL LIGHT AT 30A BEGAN SMOKING. CABIN LIGHTS WERE SECURED AND A DEADHEADING CREW MEMBER OPENED THE PANEL AND DISCONNECTED THE SHORTING LEADS FROM THE LIGHT. FOUND CTR READING LIGHT PWR SUPPLY MODULE BURNT. REPLACED OVHD PSU, CHECKS SDR MASA200601550Light · inoperativeASH 6015 PHX. AIRSTAIR DOOR BOARDING LIGHT INOPERATIVE. MX RELAMPED. OP'S CHECK GOOD.SDR 1322060706Light · malfunctionedDURING FLIGHT FLUORESCENT LIGHT ABOVE LAV SINK EMITTED ACRID SMELL AND MELTED ITS SOCKET.SDR 1322060706ABallast · malfunctionedDURING FLIGHT FLUORESCENT LIGHT ABOVE LAV SINK EMITTED ACRID SMELL AND MELTED ITS SOCKET.SDR MASA200601535Circuit Breaker · trippedASH 6550 ONT. SMOKE SMELL COMING FROM FWD LAV AREA. MX FOUND C/B POPPED FOR SIDEWALL LIGHTING. MX RESET C/B AND INSPECTED. NO SMELL OF SMOKE NOTED.SDR SIMA200615804Ballast · faultyELECTRICAL TYPE ODOR IN ROWS 6 AND 7. REPLACED CEILING LIGHT BALLAST OVER SEAT 6A IAW EMB 145 AMM 33-21-05. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR C2XA06IA088Ballast · burnedIAH - FLIGHT 2866, DURING CLIMB THE CREW REPORTED SMOKE IN THE GALLEY. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE GALLEY LIGHT BALLAST, OPERATIONALLY CHECKED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVEDSDR BTA2006F00001Power Supply · unserviceableFOLLOW-UP REPORT: SMOKE REPORTED INT THE CABIN. FOUND LT FWD FLUORESCENT LIGHT PROTECTED POWER SUPPLY, SHOWS SIGNS OF OVERHEATING. REMOVED PROTECTED POWER SUPPLY PN TR992, SN 35608, INSTALLED PN AL-5112, SN 40763. PRECAUTIONARY CHANGED THE INVERTER CONNECTESDR COMA0660356Light · inoperativeFLIGHT 9454 - LAST THREE ROWS OF EMERGENCY LIGHTS NOT FUNCTIONING. FERRIED AIRCRAFT TO CVG, PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTING SYSTEM, NO DISCREPANCIES NOTED.SDR SIMA200614203Ballast · odorELECTRICAL SMELL AT SEATS 8A AND 9A. RAI BALLAST AT SEAT 8A. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR TRAX200600238Light · inoperativeASD LAMP LIGHT INOP.SDR C2XA06CL051Ballast · burnedCLE FLIGHT 3156 THE CREW REPORTED A ELECTRICAL BURNING SMELL IN THE REAR OF THE AIRCRAFT. MAINTENANCE INSPECTED AND REPLACED THE LIGHT BALLAST AT ROW 18. OPERATIONAL CHECKS WERE GOOD.SDR AALA20060306Socket · inoperativeDFW - REPORTED SMOKE AND SMELL IN THE CABIN. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. FOUND FORWARD UPPER SIDEWALL LIGHT LAMP SOCKET AT SEAT 6AB DAMAGED. REPLACED LAMP SOCKET FOR FORWARD UPPER SIDEWALL LIGHT LAMP HOLDER AT SEAT 6AB. SYSTEM GROUND CHECKSDR MASA200601310Socket · faultyASH 6346 PHX - CEILING LIGHT ROW 4A/B SMOKING. MX DISCONNECTED LIGHT ASSY FROM POWER SUPPLY AND REMOVED AND REPLACED SOCKETS.SDR HNAA0600037Socket · arcedELECTRIC SMELL IN CABIN. FOUND BULB SOCKET BURNED AT SIDEWALL LIGHTING AT ROW 9 RT SIDE.SDR CA060509008Ballast · overheated(CAN) LAMP SOCKET OVERHEATED AT BALLAST 27LG CAUSING SMOKE ODOR IN CABIN. (TC NR 20060509008)SDR 2006FA0000450Light · burned outFLUORESCENT LIGHT ASSY FAILED AND DISPERSED SMOKE IN CABIN. POWER SUPPLY GOT HOT AND DAMAGED ADJACENT INSULATION. LIGHT ASSY WAS REPLACED WITH FACTORY NEW.SDR 2006FA0000449Light · burned outFLUORESCENT LIGHT ASSY FAILED AND DISPERSED SMOKE IN CABIN. POWER SUPPLY GOT HOT AND DAMAGED ADJACENT INSULATION. LIGHT ASSY WAS REPLACED WITH FACTORY NEW.SDR DL777060343Light · sparksFLORESCENT LIGHT SPARKED. FOUND LIGHT BULB CONTACT AND LIGHT ASSY CONTACT BOTH ARCED, FWD TO MCO AND PLAC PER MEL. REMOVED AND REPLACED LIGHT ASSY. REMOVED AND REPLACED BALLAST AND OEU 3-2-1. REPOSITIONED LAMP, OPS OKAY.SDR TRAX200600146Bulb · inoperativeGALLEY SERVICE DOOR EMER EXIT LIGHT HAS BULBS INOP.SDR DL777060317Ballast · odorOVERHEAD LIGHT BALLAST IN FLT ATTENDANT CREW REST AREA MADE BURNING ODOR WHEN TURNED ON. MIDDLE COMPARTMENT AFT ON CAPT SIDE. FLT ATTENDANT REPORTS NO SMOKE OR FIRE. RAN LIGHT ON GRD AND NO TROUBLE FOUND. DISCONNECT AND STOW BALLAST CONNECTOR AS PRECAUTIONSDR DL76K060294Psu · burnedDURING MTC ON 4/19/06 AT GSO ONE LED LIGHT ASSY BURNED & FLAMED UP AT THE CIRCUIT BOARD (FWD MOST, CENTER ROW, LT LIGHT). THE CAUSE HAS YET TO BE DETERMINED. THE AC WIRING HAS BEEN CHECKED AND THE PART WAS REPLACED. THE OLD LIGHT PANEL HAS BEEN SENT TO GOODSDR AWXA200600665Light · intermittentLAS - FLT 0554 - FLIGHT ATTENDANTS REPORTED SEEING SPARKS AROUND AIR VENTS ON THE RT SIDEWALL BETWEEN ROWS 11 AND 12. MAINTENANCE INSPECTED WIRING IN THE OVERHEAD PANELS FROM ROW 10 TO ROW 14 FOR DEFECTS. NO DEFECTS WERE NOTED. REMOVED AND REPLACED THE RT SSDR HNAA0600026Psu · burnedSMOKE COMING FROM CABIN 1AC AREA. REMOVED AND REPLACED PSUSDR SWIA200616528Ballast · failedWHILE IN CRUISE BURNING ODOR IN COCKPIT FOR A FEW MINUTES THEN DISAPPEARED. AFTER LANDING AND TAXI IN VERY STRONG BURNING ODOR FROM APPROX BEHIND F/O'S SEAT IN NR 2 CB PANEL AND MAYBE BEHIND IT. REMOVED AND REPLACED GALLEY LIGHT FIXTURE AND BALLAST PER M/M 3SDR MASA200601029Receptacle · burnedBURNED WIRE SMELL IN FWD PART OF AC. MX FOUND THE FWD GALLEY LIGHT ASSEMBLY HAD A BURNED BULB RECEPTICAL. REMOVED AND REPLACED THE LIGHT ASSEMBLY.SDR QXEA200600964Ballast · overheatedPDX- FLIGHT 2525 - DETECTED A FAINT HOT ELECTRICAL WIRING/INSULATION ODOR IN THE PAX CABIN AT ROW 1. INSPECTED AND FOUND OVERHEAD LIGHT BALLAST FOR FORWARD LEFT LIGHT PS 45 HOT. NO FIRE DETECTED. REMOVED AND REPLACED BALLAST IAW TASK 33-21-03 OPS CK GOOD. SDR CA060413003Ballast · burnedEN ROUTE A PASSENGER NOTICED AN ELECTRICAL BURNING SMELL. HE ALERTED THE F/A WHO ALERTED THE CAPTAIN. CAPTAIN CONFIRMED THE SMELL. AIRCRAFT THEN DIVERTED. AIRCRAFT LANDED UNEVENTFULLY WITH NO NEED FOR EMERGENCY SERVICES. AIRCRAFT PROCEEDED TO GATE. IN SPSDR 2006FA0000382Lamp · inoperativeDURING ROUTINE LAMP REPLACEMENT, IT WAS DISCOVERED THAT ONE END OF THE REMOVED UNIT WAS DISCOLORED. THE DISCOLORATION WAS THOUGHT TO BE DUE TO OVERHEATING. THE LOCATION OF THE FAILED LAMP WAS IN THE GALLEY OVERHEAD. INSTALLED NEW UNIT OF SAME MFG AND PN. OSDR C2XA06IA038Ballast · malfunctionedIAH - FLIGHT 3014, A BURNING SMELL WAS NOTED AT SEAT 5A. MAINTENANCE REMOVED AND REPLACED THE LIGHT BALLAST AT SEAT 5A, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA06IA041Ballast · malfunctionedIAH - FLIGHT 2732, A BURNING SMELL WAS NOTICED IN THE GALLEY. MAINTENANCE REMOVED AND REPLACED TWO LIGHT BALLASTS, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICESDR HNAA0600018Socket · burnedOVERHEAD LIGHT AT ROW 3 LEFT SIDE IS SMOKING. FOUND LAMP CARRIER DAMAGED, DEACTIVATED IAW SPECIAL PROCEDURES 33.1.SDR NW6A00603001Ballast · failedSTL - SMOKE IN CABIN / FOUND LIGHTING BALLAST PX48 SHORTED. REPLACED BALLAST PS48 IAW CRJ700 M/M 33-21-01.SDR REXA200600024Light · defectiveBURNING ELECTRICAL SMELL/ ACIDIC ODOR NOTED WITHIN FLIGHT DECK AT GATE. REMOVED AND REPLACED GALLEY LIGHT ASSEMBLY (SECOND FROM TOP) IAW AIRCRAFT MAINTENANCE MANUAL. AIRCRAFT OKAY FOR SERVICE.SDR HNAA0600013Light · burnedAIRCRAFT WAS PARKED STATIC AT THE GATE, NO PAX ON BOARD. CREW RETURNED TO AIRCRAFT AND NOTICED SMOKE FROM THE ROW 1 AREA. THE OVERHEAD LIGHT DID HAVE SOME SMOKE COMING FROM IT THEN A VISABLE FIRE BROKE OUT AS WELL FROM THE OVERHEAD LIGHT SOCKET. CAPTIAN INDISDR QXEA200600578Light · looseBUR - ON FLIGHT 2505, FLIGHT ATTENDANT REPORTED ARCING NOISE IN LAV THEN THE LAV LIGHTS FAILED. NO C/B'S WERE POPPED BUT WE PULLED C/B M5 ON CBPZ AS A PRECAUTION. MAINTENANCE INSPECTED AND FOUND LIGHT IN LAV NOT SEATED IN RECEPTICLE. RESEATED LAMP, OPERATEDSDR DLM88060118Ballast · overheatedDIV TO BNA, F/A REPORTS BURNING ELECTRICAL SMELL IN MID CABIN. FOUND BALLAST AT SEAT 25ABC BURNT. REPLACED SAME.SDR RAIA00601063Control Module · odorFLT 5536 - DEN - STRONG ODOR FROM FORWARD CABIN. MAINTENANCE FOUND BURNED LIGHTING CONTROL MODULE AND BALLAST FOR CEILING LIGHTS AT 1A. BOTH ITEMS WERE REPLACED.SDR RAIA00601060Bulb · looseFLT 8068 - ORD - F/A REPORTED BURNING WIRE SMELL AND HEARD POPPING NOISE OVER SEAT 1A. MAINTENANCE INSPECTED AND RESECURED LOOSE BULB AT SEAT 1A.SDR SWIA200616095Light · burnedOVERHEAD AISLE LIGHT OVER SEAT 10A MELTING HEAD LINER AND CAUSES LARGE BURN MARKS AND SMOKE (VERY FAINT). REPLACED CABIN LIGHT FIXTURE ASSEMBLY FOR SEAT 10A. OPERATIONAL CHECK GOOD.SDR 2006F00030Light · inoperativeNWA NR88, 12/24/05, HNL-SEA: SEAT-SPECIFIC CABIN LIGHTING SYSTEM FAILED AT ALL SEATS, SHORTLY AFTER IN-FLIGHT ENTERTAINMENT/VIDEO SYSTEM FAILURE. OCCURRED 2 HOURS INTO THE TRANS-PACIFIC FLIGHT, WELL BEFORE THE MID-WAY POINT. LIGHTS RESTORED AFTER 45 MIN. UPSDR 2006F00028Light · inoperativeNWA NR 88, 12/24/05, HNL-SEA: SEAT-SPECIFIC CABIN LIGHTING SYSTEM FAILED AT ALL SEATS, SHORTLY AFTER IN-FLIGHT ENTERTAINMENT/VIDEO SYSTEM FAILURE. OCCURRED TWO HOURS INTO THE TRANS-PACIFIC FLIGHT, WELL BEFORE THE MID-WAY POINT. LIGHTS RESTORED AFTER 45 MIN
Back to JASC 3320