JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021092421599Light · inoperativeSEAT 12DEF EMERGENCY EXIT DOOR SIDEWALL LIGHT INOP / [01] RELAMPED IAW AMM 33-21-00SDR JJBA20210915030Ballast · meltedSMELL OF INSULATION BURNT IN CABIN APPROX HALF WAY UP FOUND PLASTIC BULB SOCKET ON CEILING LIGHT BALLAST AT SEAT 18A MELTED. REMOVED AND REPLACED HARNESS ASSEMBLY ELECTRICAL. OPS CHECK SAT.SDR SWAA2021091316011Ballast · inoperativeSIDEWALL LIGHT ABOVE R/H OVERWING EXIT DOOR INOP / [01] R&R'D BALLAST PER AMM 33-21-00. THIS CLEARS MEL 33-2-03. MDDR# 26052SDR HNAA2021090700443Bulb · smokeDURING TAKEOFF BETWEEN 400-2000FT FUMES SMELL IN COCKPIT AND FWD CABIN. SEE LP 249922-2 AND 249923-1 FOR TROUBLESHOOTING AND ENGINE RUNS. WHILE TROUBLESHOOTING, FOUND GALLEY COURTESY LIGHT BULB TO BE SMOKING WHILE OPERATING. R+R'D LIGHT BULB. NEW BULB OPERATESSDR AALA202108250691Lamp · burned outAIRCRAFT WAS NOT GROUNDED: SMOKE DETECTOR IN LAVATORY E WENT OFF WITH THE APPROPRIATE CHIMES, LAVATORY WAS SEARCHED WITH NO SOURCE DETECTED. FLIGHT ATTENDANTS NOTED SMOKE AROUND THE AFT GALLEY 4R READING LIGHT AND TURNED IT OFF . MAINTENANCE RELAMPED THE READSDR SWAA2021082409305Lamp · inoperativeCAPTAIN SIDE PAX CABIN LIGHT ON OVERWING EXIT OUT. ; / [01] RELAMPED LEFT OVERWING EXIT DOOR LIGHT IAW AMM 33-51-04SDR SWAA2021071593456Light · inoperativeSIDEWALL LIGHTS ROW 6-9 CAPTAINS SIDE INOP ( CABIN INTERIOR ILLUMINATION; WITH PHOTOLUMINESCENT EMERGENCY ESCAPE PATH MARKING SYSTEM ) / R&R'D LIGHT ASSY AT ROW 7ABC OPS CK GOOD PER AMM 33-21-00. CLR #91233SDR SWAA2021071592870Bulb · inoperativeFLT ATTDT REPORTS AFT GALLEY LIGHT BURNT OUT WITH SCORCH MARKS AND ELECTRICAL SMELL. ; / [01] REMOVED AND REPLACED RH AFT GALLEY WORK LIGHT BULB PER MM 33-26-01; OPS CHECK GOOD. INSPECTED SOCKET ASSY WITH NO DEFECTS NOTED. PERFORMED SMOKE OR FUMES IN CABIN CONSDR SWAA2021070689963Light · faultedFLT ATT REPORTED STRANGE SMELL AFT GALLEY POSSIBLE PLASTIC SMELL TURNED GALLEY PWR OFF SMELL WENT AWAY / C/W FIM TASK 21-00-TASK 806 ( SMOKE OR FUMES IN THE CABIN ) R&R'D CABIN SIDEWALL LIGHT @ 28;29 DEF I.A.W. AMM 33-21-00. RAMP REPORTED FOUL ODOR IN AFT CARGSDR SWAA2021062182995Ballast · failedBAD ODOR STILL NOTED DURING APPROACH ON ENGINE BLEEDS / ODOR COMING FROM FRONT GALLEY AREA. R&R O/H CIELINE BALLEST IN FWD GALLEY PER AMM 33-22-00 NO MORE ODORS DETECTED STILL HAS FAINT RESIDUAL SMELL AIRING CABIN BALAST INSTALLED P/N K100-140-001 S/N BN 10756SDR SWIA202158628Ballast · failedFLIGHT ATTENDANTS REPORTED DISTINCT ODOR OF ELECTRICAL SMOKE IN FLIGHT. ODOR DISSIPATED WITHIN 5 MINUTES. ODOR WAS STRONGER TOWARDS THE REAR OF THE CABIN. (FLIGHT 3623 - FILED CLOSED) TROUBLESHOT PER FIM 21-22-00 AND FOUND BALLAST FOR SIDEWALL LIGHT 18DSDR SWAA2021060980452Light · inoperativeSIDE WALL LIGHTS AT 15ABC - 22ABC INOP (6 LIGHTS IN A ROW). ( CABIN INTERIOR ILLUM BOEING SKY INTERIOR PHOTOLUMINESCENT ) / R&R'D LEFT FWD EMERGENCY EXIT SIDEWALL LIGHT REF AMM 33-21-32. CL#89309SDR SWAA2021060879817Light · inoperativeSIDE WALL LIGHTS AT 15ABC - 22ABC INOP (6 LIGHTS IN A ROW). ( CABIN INTERIOR ILLUM BOEING SKY INTERIOR PHOTOLUMINESCENT ) / R&R'D LEFT FWD EMERGENCY EXIT SIDEWALL LIGHT REF AMM 33-21-32 CL#89309SDR AALA202105219015Light · inoperativeAIRCRAFT WAS NOT GROUNDED: SMALL LIGHT ON BOTTOM RIGHT ON FORWARD CLOSET FRAME IS MISSING. REMOVED AND REPLACED EMERGENCY ASSEMBLY LIGHT AT BOTTOM OF FORWARD CLOSET IAW SWPM 20-50-15.SDR QXEA2021051700242Control Panel · faultedFORWARD OVERHEAD EXIT, NO SMOKE, FASTEN BELTS, AND LAV LIGHTS NOT ILLUMINATING DURING NORMAL OPERATION OR DURING TEST. REMOVED FROM SERVICE. C/W Q400 FIM TASK 32-24-00-810-803. WIRING TESTS GOOD. REPLACED RELAY 3323-K1 DONE IAW Q400 AMM 20-30-16-960-801. NO HESDR SWAA2021042265003Lens · crackedRH OVERWING EXIT FLUORESCENT LIGHT LENS CRACKED / LOG PAGE 1800653 R&R'D RH OVERWING EXIT FLOURESCENT LIGHT LENSE PER AMM 33-51-11 CL#77252SDR AALA202103059061Bulb · damagedAIRCRAFT WAS GROUNDED: G4 GALLEY CEILING LIGHT DAMAGED, GENERATED ELECTRICAL SMOKE SMELL; SMELL DISSIPATED ONCE GALLEY LIGHTS TURNED OFF. REPLACED GALLEY LIGHT BULB IAW AMM 33-27-00, OPS CHECK GOOD.SDR AALA202107221436Lens · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK GALLEY FORWARD WORK LENS LIGHT IN PASSENGER CABIN (1EA). REPLACED GALLEY FORWARD WORK LIGHT LENS IN PASSENGER CABIN (1EA) PER CMM 25-32-29.SDR UO2R2021111101Light · discoloredEMTEQ LED FLEXIBLE ACCENT LIGHTING ASSEMBLY FOUND BLACKENED AND DISCOLORED DURING REMOVAL FROM AFT LAVATORY CABINET.SDR SWAA2021021748530Lamp · inoperativeWINDOW LIGHTS INOP AT POSITIONS 18 LT; EMERGENCY OVERWING EXIT LEFT AND RIGHT SIDE. RELAMPED 18 LT WINDOW LIGHT; RESECURED EMERGENCY OVERWING RT WINDOW LIGHT 25 PER REF B737 AMM 33-21-00-960-801; REMOVED & REPLACED LT EMERGENCY OVERWING WINDOW LIGHT B2LL2ST ASDR HNAA2121012300028Ballast · odorDURING DECENT AT 11000 FEET F/A SMELT PLASTIC, RUBBER BURNING SMELL LOCALIZED IN GALLEY. MAINTENANCE PERFORMED: TROUBLESHOT, PER EMB145 FIM 21-20-00-810-803. REMOVED AND REPLACED BALLAST FOR LIGHTS AT SEAT 1A, PER EMB 145 AMM 33-21-03. OPERATIONS CHECK GOODSDR DALA2021012100400Ballast · overheatedUNUSUAL ODOR CABINET TO LEFT OF IFE HEAD. MAINTENANCE INSPECTED FOR ODOR IN FORWARD GALLEY IFE AREA AND FOUND FORWARD RIGHT GALLEY OVERHEAD LIGHT BALLAST ASSEMBLY WIRE SHOWING BURN MARK. INSTALLED 2 NEW LED LIGHT BALLAST ASSEMBLIES. SYSTEM OPERATION IS NORMSDR AALA202012149005Ballast · smokeAIRCRAFT WAS GROUNDED. RIGHT AFTER ROTATION STRONG PLASTIC ELECTRICAL SMELL NOTICED BOTH BY CABIN CREW & COCKPIT CREW. APPLIED SMOKE QUICK ACTION AND SMELL DISSIPATED. EMERGENCY WAS DECLARED FOR LANDING AT PHL. ACCOMPLISHED J/C 26L00021001 & FOUND ELECTRICSDR MASA2020120910644Ballast · odorELECTRICAL SMOKE SMELL AT ROW 20. FOUND TO BE CAUSED BY CEILING LIGHT BALLAST. DEACTIVATED AND PLACED ON MEL.SDR SWIA202054408Light · smokeON DESCENT FA'S REPORTED THAT THE CABIN LIGHT BECAME UNCONTROLLABLE. WHEN THE CABIN LIGHT SWITCH WAS OFF, THE LIGHTS WOULD COME ON AND VICE-VERSA. THEN THE CABIN BEGAN TO SMELL OF ELECTRICAL SMOKE, BUT NONE COULD BE SEEN. SMELL CAME FROM OVERHEAD BIN 17A/B.SDR SWAA2020110928646Light · burnedELECTRICAL BURNING SMELL FORWARD CABIN. R & R FWD GALLEY LIGHT ASSEMBLY, PER MM 33-26-02. COMPLIED WITH CONDITIONAL INSPECTION, PER MM 05-51-56.SDR SWAA2020100821629Lamp · inoperativeEMERGENCY LIGHT ABOVE 20 ABC IS INOPERABLE. RE-LAMPED EMERGENCY LIGHT ABOVE 20 ABC, PER AMM 33-51-03.SDR DALA2020092403165Bulb · unsecureWHILE IN FLIGHT, FORWARD LAV OCCUPIED INOPERATIVE BULB FELL OUT. AFTER REINSERTING PUSHED PRESS TO TEST AND OBSERVED ARCING AND SPARKS. CORRECTIVE ACTION: FOUND L9001 SWITCH BAD AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR ASOA202009224024Control Module · smokeIAH FLIGHT 3907. THE CREW REPORTED AN ELECTRICAL SMOKE ODOR IN THE FORWARD CABIN. MAINTENANCE REMOVED AND REPLACED THE CABIN LIGHT CONTROL MODULE, OPERATIONALLY TESTED WITH NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR IPXA2020090239734Power Supply · malfunctionedINSPECTION TYPE: N/A EMERGENCY DOORS LIGHT ON OVERHEAD PANEL WAS FLASHING ON AND OFF CONTINUOUSLY. NO EICAS MESSAGE OR OTHER INDICATIONS. PERFORMED T/S OF PSEU CHANNEL 174 AND 188 IAW SSM 52-70-01. FAULT CODE 405 REMOVED AND REPLACED CARD #10 IN PSEU IAW MMSDR AALA202008049014Ballast · failedAIRCRAFT WAS GROUNDED: SMOKE FUMES IN CABIN & GROUND POWER SHOWS 460HZ ON ELECTRICAL PAGE. SMELLED ELECTRICAL BURNING ALONG WITH NO POWER TO DC1. REPLACED BUSS TIE RELAY 30XU1, NR 1 DC BUSS CONTACTOR 1PC1 IAW AMM 24-35-55. CABIN SIDE WALL OVERHEAD LIGHTS BETWESDR AALA202008049013Ballast · failedAIRCRAFT WAS GROUNDED. SMOKE FUMES IN CABIN & GROUND POWER SHOWS 460HZ ON ELECTRICAL PAGE. SMELLED ELECTRICAL BURNING ALONG WITH NO POWER TO DC1. REPLACED BUSS TIE RELAY 30XU1, NR 1 DC BUSS CONTACTOR 1PC1 IAW AMM 24-35-55. CABIN SIDE WALL OVERHEAD LIGHTS BESDR QXEA2020061500183Light · overheatedRAMP REPORTS AFT GALLEY WORK LIGHT OVERHEATING / SMOKING WHEN TURNED ONSDR SWAA2020052980364Ballast · inoperativeOVERWING EMERGENCY EXIT SIDEWALL LIGHT AT ROW 11 C + B INOPERATIVE. R & R OVERWING EMERGENCY EXIT SIDEWALL LIGHT BALLAST. OPERATIONS CHECK GOOD IAW AMM 33-21-00. CLEARING 38862 CLOSING DMA 0155794.SDR UIEA2020050700987Ballast · failedFOUND SEC 41 CEILING PANEL LIGHT ELECTRONIC BALLAST FUNCTIONAL FAIL.(<P>IAW AMM 33-28-02-004-001 AND 33-28-02-404-007 REV 98 REPLACED THE BALLAST AND TEST, THE RESULT WAS SATISFACTORY.</P>)SDR SIMA202004221001Light · odorELECTRICAL BURNING SMELL NOTED BY FA AND MULTIPLE PASSENGERS DURING CLIMBOUT. PERFORMED FIM 25-31-00, NO ODOR NOTED. INSPECTED ALL HARNESSES AND RELAYS IN AND AROUND COCKPIT, FA FWD SEAT AND ALL ENTRY WAY LIGHTS, EMERGENCY FLASHLIGHTS. NO ODOR NOTED, GROSDR AALA202004079004Ballast · faultyAIRCRAFT GROUNDED - SMOKE ODOR IN CABIN PASSING 12000 FEET; IT WAS A BURNING ELECTRICAL / BURNED POPCORN SMELL. ODOR PREVALENT IN ROWS 10-14 WITH A SLIGHT HAZE PRESENT. ACCOMPLISHED MCM 05-96-70 TO TROUBLESHOOT ODOR. FOUND FAULTY BALLAST FOR CEILING LIGHT AT RSDR VNAA2020040211101Dimmer · failedELECTRICAL BURNING SMELL IN CABIN. REMOVED AND REPLACED CEILING PANEL DIMMER AND CEILING BULBS AT SEAT ROW 12 AC IAW CRJ 700 AMM. OPS CHECK GOOD AT THIS TIME.SDR AALA202003169005Lamp Socket · defectiveAIRCRAFT WAS GROUNDED: PLASTIC BURNING ODOR ISOLATED TO SEAT 19A READING LIGHT. DISAPATED WHEN LIGHT SELECTED OFF. ACCOMPLISHED SMOKE ODOR CARD 43L00021001. FOUND BAD READING LIGHT SOCKET AT 19A, REMOVED AND REPLACED 19A ANDM19B READING LIGHT ASSEMBLY IAW AMM SDR ASOA2020031184003Light · overheatedIAH - FLIGHT 4328, THE CREW REPORTED CEILING LIGHT SMOKE SMELL 1A & 2A. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE AFFECTED CEILING LIGHT ON MEL 33-20-00-2, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SESDR SIMA202003096003Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT IAW 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. NO FURTHER DEFECTS FOUND AT THIS TIME. END.SDR SWAA2020030642189Ballast · inoperativeRT SIDE OVERWING EXIT DOOR SIDEWALL LIGHT INOP. CLOSING DMA REFERENCE 0087709 R & R RT OVERWING EMERGENCY EXIT DOOR BALLAST IAW AMM 33-51-04 CLOSING# 31027.SDR VNAA2020030311102Power Unit · malfunctionedSUPPLEMENTAL INFORMATION: SMOKE SMELL IN THE CABIN FOR CABIN LIGHTS BETWEEN ROWS 11 THROUGH 15. DEFERRED CABIN LIGHTS AND GOT EA72-2020-037 TO ALLOW TO CAP AND STOW THE WIRES FOR THE LIGHTS. REMOVED AND REPLACED CEILING LIGHTS POWER UNIT/DIMMER IAW CRJ700 AMM.SDR ASAA2020012972008Light · burned outF/A REPORT BURNING LIGHT BULB SMELL ROW 31. TURNED OFF CABIN LIGHTS HAD PAX UNPLUG FROM SEAT BACK POWER AND INSPECT ELECTRONICS IN OVERHEAD BIN ORDER DISSIPATED TO NOTHING LEFT LIGHTS OFF AS PRECAUTION FOR REMAINDER OF FLIGHT. GROUNDED - YES. FOUND SEAT 31E RESDR SIMA202001243001Control Module · failedBURNING WIRE SMELL FROM OVERHEAD FLUORESCENT LIGHTING OVER SEAT 1A-C/A-REMOVED AND REPLACED LIGHTING CONTROL MODULE IAW AMM 33-21-01.OPS CHK GOOD.SDR HNAA2020012000026Ballast · failedSTRONG ELECTRICAL/BURNING SMELL COMING FROM FRONT OF A/C (VERY PROMINANT FROM FWD FA VENT). FOUND BURNT OUT LH SIDE WALL BALLEST. REMOVED AND REPLACED BURNT BALLAST IAW 33-21-03. OPS CHECK GOOD OK FOR SERVICE. INSPECTED LIGHT SOCKETS, NO DEFECTS FOUND IN SUROUSDR DALA2020012210463Lens · unsecureFLIGHT CREW REST LIGHT COVER FELL OFF. LIGHT COVER REFITTED.SDR SWAA2020030442134Ballast · burnedSUSPICIOUS ODOR REPORTED BY FLIGHT ATTENDANT IN / CABIN AROUND ROW 20. / PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56 AND FIM TASK / 21-00 TASK 806. OPENED COMPARTMENTS AND CEILING PANEL IN CABIN AREA 17/18/19/20/21/22 ABC SDR SIMA202001064009Light · inoperativeDURING PS-2 CHECK FOUND COURTESY LIGHT INOP AT GALLEY.-C/A-REMOVED AND REPLACED COURTESY LIGHT IAW EMB 145 AMM 33-26-05 OPS CHECK GOODSDR ASOA2020010733001Unknown · odorTHE CREW REPORTED BURNT SMELL AT SEAT 9A. MAINTENANCE INSPECTED AND RELEASED AIRCRAFT I/A/W MEL 33-20-00-1. SUPPLEMENT TO FOLLOW
Back to JASC 3320