JASC 3320

Service difficulty reports · 2,972

Reports filed under 3320 · Passenger Compartment Lighting, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASOA2019123055120Control Module · odorCREW REPORTED BURNING SMELL IN GALLEY AREA. INSPECTION DETERMINED SMELL CAME FROM CEILING LIGHTS CONTROL BOX. REMOVED AND REPLACED CEILING LIGHT CONTROL MODULE WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.Dec 25, 2019 · N12135 · Emb EMB145XRSDR DALA2019112906961Bulb · burned outAFTER FLIGHT F/A REPORTED LEFT AFT LAV SMOKE DETECTOR WENT OFF IN FLIGHT. ONE PAX REPORTED SMELLING SOMETHING. IN FLIGHT F/A REPORTED WHAT PAX SAID I ASKED FOR DETAILS, SHE SAID SHE SMELLED NOTHING; AND NO REPORT OF ALARM. ONLY AFTER WE DEPLANED DID SHE TELL MNov 27, 2019 · N973DL · Doug MD88SDR AALA2019112109043Ballast · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS INTERMITTENT ODOR NEAR CEILING. SMELLS LIKE RUBBER. HAD FLIGHT ATTENDANT TURN OFF ALL LIGHTS, ODOR NEVER CAME BACK. REMOVED AND REPLACED AFT GALLEY CEILING LIGHTS BALLAST ASSEMBLIES IAW AMM:33-24-11. OPS CHECKS GOOD.Nov 19, 2019 · N193UW · Airbus A321211SDR DALA2019111406637Transformer · failedCREW REPORTED SMOKE SMELL AFT CABIN ALARM SOUNDED SMELL DISSIPATED. CREW INFORMED TO FILL OUT REPORT. CALL CAR NO GO ODI ATTACHED. WHILE WAILKING THROUGH CABIN LOOKING FOR ANY INDICATION OR SMELL OF SMOKE THE AFT LT LAV HAS A LOUD BUZZING SOUND COMING FROM CABNov 13, 2019 · N975DL · Doug MD88SDR SWAA2019110838707Ballast · inoperativeSIDEWALL LIGHT ABOVE L/H OVERWING EXIT IS INOP. / REMOVED AND REPLACED BALLAST PER M/M 33-21-00.Nov 7, 2019 · N7853B · Boeing 7377Q8SDR DALA2019111166545Lamp · inoperative(AIRCRAFT 6709, L/P 6570375) FWD LAV OCCUPIED LIGHT ON OVERHEAD PANEL EMITS SPARKS WHEN TOUCHED. CORRECTIVE ACTION: RELAMP WITH BULB PER B757 WDM 33-26-21 OP CKS NORMAL, NO SPARKS NOTED.Nov 6, 2019 · N6709 · Boeing 757232SDR 2020F00089Light · discoloredRECEIVED FROM OPERATOR, AUSTRIAN AIR, LED INTERIOR LIGHTING WITH SIGNS OF OVER HEATING. TESTING AND EVALUATION BEING PERFORMED. LOCAL FAA INFORMED AND ASSISTING WITH INVESTIGATION.Oct 31, 2019 · Airbus A320*SDR SWAA2019101437793Control Card · faultySMOKE AT ROW 22F OVERHEAD PASSENGER READING LIGHT. REPLACED CONTROL CARD AT 22DEF IAW AMM. DECLARED EMERGENCY, SMOKE AT ROW 22F OVERHEAD PASSENGER READING LIGHT. REPLACED CONTROL CARD AT "22DEF" IAW AMM.Oct 9, 2019 · N728SW · Boeing 7377H4SDR SWAA2019100837650Ballast · inoperativeR/H OVERWING CABIN LIGHT INOPERATIVE. R&R BALLAST PER AMM.Oct 2, 2019 · N7741C · Boeing 7377BDSDR SWAA2019100877640Bulb · unsecureDURING DESCENT FLIGHT ATTENDANTS AND PASSENGERS REPORTED BURNING SMELL IN AFT CABIN/GALLEY AREA. LASTED APPROXIMATELY 5 MINUTES, THEN WENT AWAY. FOUND BULB NOT SECURED IN LIGHT ASSEMBLY. CORRECTLY SECURED BULB PER AMM.Sep 30, 2019 · N225WN · Boeing 7377H4SDR AALA2019100219021Light · burnedAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTS BURNING SMELL AROUND LAST 2 ROWS OF COACH, LIKE RUBBER SMELL. MAINTENANCE ACCOMPLISHED CARD 05-96-70. FOUND LAV D SINK/COUNTER TOP LEDS BURNT, FULL OF SOAP. REPLACED HARNESS ASSY IAW ESO 60914. ALL CHECKS GOOD.Sep 30, 2019 · N957NN · Boeing 737823SDR CALA2019091701557Ballast · faultyAPPROX 10 PAX ROW 38 SMELLED ELECTRICAL BURNING SMELL. IT CAME AND WENT. PERFORMED SMOKE/ODER IN THE CABIN CONDITIONAL INSPECTION PERFORMED. AMM REF 05-51-26-800-801 C1. I CHECKED IFE BOXES UNDERSEATS ROWS 38,A THROUGH ROW 29 A. NO SMOKING LIGHTS, SEAT BELT. PSep 16, 2019 · N77296 · Boeing 737824SDR SWAA2019091236859Ballast · faultyCREW REPORTED BURNING PLASTIC SMELL IN CABIN THROUGHOUT FLIGHT. R&R AFT ENTRY LIGHTS BALLASTS PER AMM.Sep 10, 2019 · N747SA · Boeing 7377H4SDR SWAA2019091236826Ballast · faultyCREW REPORTED BURNING PLASTIC SMELL IN CABIN THROUGHOUT FLIGHT. R&R FORWARD ENTRY LIGHTS BALLASTS PER AMM.Sep 10, 2019 · N747SA · Boeing 7377H4SDR DALA2019083105108Socket · burnedFWD LAV FLUORESCENT LIGHT BURNED OUT ODOR OF BURNED INSULATION OR BALLAST. C/W NO GO ODI CHECKLIST 2172 C/W JIC 2120-2367 FOUND F/C LAV AFT LIGHT UPPER SOCKET ASSEMBLY WITH HEAT DAMAGE R/R SOCKET ASSY IAW WSPM 20-31 NO SMOKE/ODOR PRESENT CHKS GOOD OK FOR SVC. Aug 30, 2019 · N911DL · Doug MD88SDR CALA20190821377Light · shortedSMOKE ODOR WAS REPORTED AT THE AFT LH LAV. INSPECTED LED WIRING AT (L-6) AND NOTICED 3RD LED LIGHT (FROM INBOARD) WAS WET. SPARE LIQUID BOTTLE SATURATED LED LIGHT CAUSING ODOR. CAPPED AND STOWED LED WIRES FOR DISCREPANT LIGHT. ALSO DISCONNECTED L6 QUICK RELEASAug 15, 2019 · N38454 · Boeing 737924ERSDR SIMA201908164002Module · failedCABIN LIGHTS WILL NOT TURN OFF. BURNING SMELL FROM LIGHT BULB NEAR FA CONTROL PANEL AND FORWARD WINDOW. REMOVED AND REPLACED CABIN LIGHTS MODULE CONTROL ASSY IAW AMM 33-21-01 OPTS CHECK GOOD .Aug 14, 2019 · N607AE · Emb EMB145LRSDR 2019FA0000275Light · shortedRIGHT FWD DOWNWASH LED LIGHT STRIP SHORTED AND SMOKED DURING DESCENTAug 14, 2019 · N441PJ · Cndair CL6002B16SDR VNAA2019081631102Ballast · failedREPORTED ELECTRICAL BURNING SMELL COMING FROM ROW 10 IN CABIN. R&R BALLAST IN ROW 10 IAW CRJ 200 AMM 33-21-04-000/400-801. NO SMELL DETECTED AT THIS TIME, OP CHECK GOOD.Aug 13, 2019 · N260JS · Cndair CL6002B19SDR 2WAA201908151211Ballast · smokeSMOKE COMING FROM OVERHEAD BIN #3 A/C RH. R/R CABIN SIDEWALL LIGHTING BALLAST IAW MD-80 AMM 33-21-03. OPS CHECK NORMAL.Aug 12, 2019 · N801WA · Doug MD83SDR AALA2019081209011Ballast · failedAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS OVERHEAD LIGHT BALLAST AT SEAT 6E WAS STINKING AND SMOKING. REPLACED BALLAST AT SEAT 6E OVERHEAD BIN. OPS CHECK OK IAW AMM 33-22-01.Aug 9, 2019 · N9618A · Doug MD83SDR SWIA2019073046104Transformer · failedSMOKE SMELL AND HAZE. BURNING SMELL WAS STRONGEST IN THE AFT AVIONICS BAY, THE CABIN LIGHT CIRCUIT BREAKER WAS TRIPPED. FLT 5538. REMOVED AND REPLACED CABIN LIGHTING TRANSFORMER RECTIFIER UNIT IAW AMM. ALL CABIN LIGHTING FUNCTIONS RESTORED.Jul 30, 2019 · N789SK · Cndair CL6002C10SDR 29GA2019073100001Unknown · malfunctionedFLIGHT# 0132 MHH/FLL REPORT: EMERGENCY CALL LIGHT AND CHIME COMES ON AND OFF ON ITS OWN. CORRECTIVE ACTION: T/S SYSTEM, COULD NOT DUPLICATE, OPS CHECKED NORMAL IAW MM 23-30-00.Jul 30, 2019 · N350AG · Saab 340BSDR DXTA2019072502667Light · defectiveCOCKPIT ODOR BURNING SMELL - ON DECENT INTO IAD, AT FL180, WE STARTED SMELLING A BURNING ELECTRICAL OR METALIC SMELL. THERE WAS NO SMOKE AND I'M NOT SURE WHAT THE SOURCE WAS. IT WAS MOST INTENCE AT 180 AND REMAINED UNTILL LANDING WHEN IT THINNED OUT. ALSO NOTJul 25, 2019 · N655QS · Cessna 560XLSDR DXTA2019072302661Light · burnedCABIN ODOR BURNING SMELL - THROUGH 28000 FEET DURING CLIMB BOTTH THE CREW AND PASSENGERS NOTICED AN ELECTRICAL BURNING SMELL. THERE WAS NO SMOKE. WE TURNED OFF THE INTERIOR MASTER SWITCH AND THE SMELL WENT AWAY. WE CONTINUED TO DESTINATION AS IT WAS ONLY 15 MIJul 23, 2019 · N633QS · Cessna 560XLSDR ASOA201907145086Light · odorFA REPORTS STRONG ODOR FROM THE OVHD GALLEY LIGHT WHEN TURNED ON. PLACED ON MEL. MX PERFORMED ADJUSTMENT/TEST OPS CHECK GOOD NO ODOR PRESENT OR NOTED AT THIS TIME.Jul 14, 2019 · N14907 · Emb EMB145LRSDR CALA2019071501198Socket · burnedELECTRICAL BURNING ODOR AROUND ROW 30 FOUND CEILING LIGHT ASSY ABOVE ROW 32-33 A,B,C STOW BIN WITH BURNT SOCKET. FOUND LEFT CEILING FLOURESCENT LIGHT AFT SOCKET ABOVE ROW 33 TO BE DEFECTIVE. REMOVED LIGHT BULB, DISCONNECTED FLOURESCENT LIGHT BALLAST, AND CAPPJul 14, 2019 · N57852 · Boeing 757324SDR ASOA20190624034Bulb · inoperativeIAH - FLIGHT 4295 THE CREW REPORTED AN ELECTRICAL BURNING SMELL IN THE BACK OF AIRCRAFT. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED A BURNT LIGHT BULB AT ROW 19, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO Jun 23, 2019 · N11547 · Emb EMB145LRSDR CALA2019061700973Ballast · overheatedSMOKE BEGAN TO FILL THE BACK OF THE CABIN. A/C DEPLANED AS QUICK AS POSSIBLE. FOUND SMOKE SOURCE, CEILING LIGHT AND BALLAST ASSEMBLY OVERHEATED ABOVE SEATS 29-30 DEF. REPLACED LIGHT ASSEMBLY OPERATED NORMAL.Jun 17, 2019 · N27722 · Boeing 737724SDR VNAA2019061651102Ballast · failedSMOKE WAS REPORTED IN CABIN. RECIRCULATION AND AFT CARGO HEATER FANS WERE TURNED OFF, AND THE SMOKE DISSIPATED. THE FLIGHT LANDED WITHOUT INCIDENT. AN EMERGENCY WAS DECLARED WITH ATC, BUT THE CABIN DID NOT BRACE. REMOVED AND REPLACED CEILING LIGHTS POWER UNIT Jun 15, 2019 · N502AE · Cndair CL6002C10SDR SIMA201906173004Control Module · odorFA REPORTS PANGENT SMELL COMING FROM SERVICE DOOR BACK TO ROW 6-C/A-FOUND CABIN LIGHT CONTROL MODULE TO BE THE SOCRCE REMOVED AND REPLACED CONTROL MODULE ASSEMBLY IAW 145 AMM 33-21-01 OPS-CHECK GOOD NO FURTHER SMELL DETECTEDJun 13, 2019 · N618AE · Emb EMB145LRSDR ASOA2019061285076Ballast · odorFA REPORTS A BURNING SMELL FROM THE GALLEY. CONTRACT MX FOUND BURNING SMELL TO BE THE GALLEY LIGHT BALLAST. DISCONNECTED BALLAST AND PLACED ON MEL. OPENJun 8, 2019 · N14904 · Emb EMB145LRSDR AALA201906099010Light · smokeAIRCRAFT NOT GROUNDED: PILOT REPORTS READING LAMP AT 25E SMOKES WHEN TURNED ON. SMELLS OF BURNING PLASTIC AND LENS COVER MISSING. MAINTENANCE REMOVED AND REPLACED LIGHT ASSY AT 25E. PERFORMED OPS CHECK ALL CHECKS OK , NO FAULTS NOTED IAW AMM 33-23-00.Jun 7, 2019 · N172AJ · Boeing 757223SDR CA190606008Power Unit · overheated(CAN) AFTER LANDING THE AIRCRAFT SHUT DOWN AT THE TERMINAL. THE CABIN OVERHEAD LIGHTING WAS TURNED ON TO ASSIST THE DEPLANING PASSENGERS. A BURNING SMELL WAS DETECTED AND SMOKE WAS OBSERVED COMING FROM BEHIND THE AFT OVERHEAD INTERIOR PANEL. THE CREW SHUT DOWNJun 3, 2019 · Bag JETSTM3212SDR 29GA2019053000001Light · missingSUPPLEMENTAL: FLIGHT# 0106 TPA/EYW REPORT: EMERGENCY CALL LIGHT FOR FLIGHT ATTENDANT IS MISSING. CORRECTIVE ACTION: INSTALLED EMERGENCY CALL LIGHT FOR FLIGHT ATTENDANT PANEL IAW AMM 25-25-25, OPS CHECK GOOD IAW AMM 23-30-00-05. (RED LENS) PN ON: 6510399May 29, 2019 · N327AG · Saab 340BSDR AALA201905289001Ballast · arcedAIRCRAFT WAS NOT GROUNDED: FORWARD ENTRY LIGHT BALLAST ARCING, L1 DOOR. MAINTENANCE REPLACED FORWARD ENTRY LIGHT BALLAST (M1679) PER AMM 33-29-00.May 26, 2019 · N823NN · Boeing 737823SDR ASOA201905235071Control Module · odorPILOT REORTED BURNING ELECTRIC SMELL COMIING FROM OVERHEAD LIGHTS IN THE GALLEY. MX REMOVED AND REPLACED THE GALLEY CONTROL MODULE IAW AMM 33-29-01 OPS CHECK GOOD PERFORMED OPERATIONAL CHECK ON BOTH COFFEE MAKERS IAW VCMM 25-30-39 OPS CHECK GOOD NO SMELL NOTEDMay 23, 2019 · N14904 · Emb EMB145LRSDR SWIA2019052145903Ballast · malfunctionedCLIMBING OUT OF FL 220 RECEIVED A CALL FROM FORWARD FA INDICATING THERE WAS VISIBLE SMOKE IN THE CABIN. SMOKE WAS VISIBLE TO FLIGHT DECK CREW AT THIS POINT AND THE ODOR OF ELECTRICAL BURN WAS PRESENT. FOLLOWED QRH RETURNED TO FIELD AND DECLARED EMERGENCY. (FLTMay 21, 2019 · N748SK · Cndair CL6002C10SDR CA190523006Ballast · failed(CAN) ON CLIMB, FA INDICATED THERE WAS VISIBLE SMOKE IN THE CABIN AND AN ODOR OF ELECTRICAL BURN WAS PRESENT, FOLLOWED QRH. CORRECTIVE ACTION: FOUND CEILING LIGHT BALLAST BURNT, BALLAST REPLACED. (TC# 20190523006)May 17, 2019 · Cndair CL6002C10SDR CA190514009Ballast · failed(CAN) DURING A MAINTENANCE GROUND RUN, AN FWD SMOKE MASTER WARNING WAS REPORTED. THEY PROCEEDED TO COMPLETE AN EMERGENCY SHUT DOWN, AND EXIT THE AIRCRAFT. WHILE EXITING, THEY OBSERVED SMOKE IN THE CABIN GETTING HEAVIER THE CLOSER THEY GOT TO THE TAIL OF THE AIMay 10, 2019 · Aerosp ATR42300SDR AALA201905069008Light · inoperativeAIRCRAFT WAS NOT GROUNDED: 2R EXIT ROW DOOR OVERHEAD LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT PER AMM 33-21-11.May 4, 2019 · N523UW · Airbus A321231SDR AALA201904309008Printed Ckt Board · burnedAIRCRAFT IN BASE VISIT: MAINTENANCE FOUND DOOR 3L SEAT BELT PCB BURNED. REPLACED PCB IAW AMM 33-24-00. GOOD FOR SVC.Apr 29, 2019 · N794AN · Boeing 777223SDR RAIA201904280001Light · damagedSTRONG ELECTRICAL ODOR COMOING FROM ROW 6CD-- DEFERRED SIDEWALL LIGHT FIXTURE (AT) ROW 6CD ON OPEN CTRL # 70054935 PER MEL 33-20-00-02 CAT C AUTHORIZED BY MX CTRL RANDY ROUBIQUE- DISCREPANCY WILL BE CLEARED ONCE DEFERRAL FOR THIS ITEM IS CLEARED. THERE WILL BApr 28, 2019 · N11137 · Emb EMB145XRSDR SWIA201904265787Ballast · odorON DEPARTURE ROLL OUT OF BOISE WE NOTICED AN ELECTRONIC BURNING SMELL. BOTH FLIGHT ATTENDANTS CONFIRMED THE SMELL THROUGHOUT THE CABIN. SMELL DISSIPATED AS WE CLIMBED OUT. ON DESCENT THE SMELL RETURNED. (FLT#3918) CLOSED REMOVED AND REPLACED THE AFT LAV LIGHT Apr 26, 2019 · N261SY · Emb ERJ170200LRSDR AALA2019042549011Ballast · overheatedAIRCRAFT WAS GROUNDED: PILOT REPORTS BURNING PLASTIC SMELL IN BACK GALLEY. AMINTENANCE FOUND ALLST IN THE G5 GALLEY PRODUCING A SMELL AND IS HOT TO THE TOUCH. MAINTENANCE REMOVED AND REPLACED THE AFT GALLEY LEFT WORK LIGHT BALLAST IAW AMM 25-31-11. OPS TEST GOApr 23, 2019 · N185UW · Airbus A321211SDR SWAA2019042231861Circuit Breaker · trippedPASSENGER CABIN, LIGHTING, EMERGENCY CHARGE, L AFT POPPED RESET BREAKER PER AMM 20-60-01.Apr 21, 2019 · N7709A · Boeing 73776NSDR IPXA2019042241309Light · inoperativeLITE IN LAV BY THE MIRROR INOP. RELAMPED GROUND CHECKED GOOD REF MM 33-51-00Apr 19, 2019 · N139UP · Airbus A300F4622RSDR RAIA201904190003Ballast · odorELECTRICAL BURNING SMELL FROM ROWS 6 AND 7 -- INSP CEILING AND SIDEWALLS AT ROWS 3-9 AND FOUND NO INDICATIONS OF ELECTRICAL BURNS. FOUND CEILING LIGHT BALLAST ABOVE ROW 7 WARMER THAN OTHER BALLASTS IN ROWS 3-9. R&R CEILING LIGHT BALLAST ABOVE ROW 7A. DURINGApr 19, 2019 · N11137 · Emb EMB145XRSDR SIMA201904164002Light · inoperativeEMERGENCY LIGHT STRIP ROW 11 INOP. DEFERRED EMERGENCY LIGHT STRIP ROW 11 REF: MEL 33-30 AUTH: 040506-CApr 14, 2019 · N846AE · Emb EMB135KLSDR SWAA2019041131584Ballast · odorDECLARED EMERGENCY, FLIGHT ATTENDANT REPORTED A BURNING ELECTRICAL ODOR IN THE FORWARD GALLEY AREA. RECIRCULATION FAN WAS LEFT ON GALLEY WORK LIGHT, TRIPPED CIRCUIT BREAKER. R&R GALLEY WORK LIGHT BALLAST PER AMM.Apr 11, 2019 · N226WN · Boeing 7377H4
Back to JASC 3320