JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020101222432Battery Pack · inoperativeL1 DOOR EGRESS LIGHT INOPERABLE. T/S AND FOUND BATTERY CHARGER AND BATTERY FOR M01675 INOPERABLE. REMOVED AND REPLACED M01675 CHARGER AND BATTERY PACK, IAW AMM 33-51-06-960-805 AND AMM 33-51-06-960-806. OPERATIONS CHECK GOOD.SDR ASAA2020100533303Sign · inoperativeL1 LOWER EXIT SIGN FELL OFF WALL. GROUNDED-YES. REMOVED AND REPLACED L1 LOWER EXIT SIGN ASSY, REF B737-700 AMM 33-51-01.SDR IPXA2020100660993Bulb · inoperativeINSPECTION TYPE: PS1, EMERGENCY LIGHT AFT BULB INOPERABLE AT L1 DOOR CEILING LIGHT. DEFERRAL OF INTEROR EMERGENCY LIGHT SYSTEM. MEL 33-51-1-0-2 M722064 PLACARD INSTALLED. RELAMPED PER MM 33-51-05. M722064.SDR CALA2020100701158Light · inoperativeSEAT ROW 10L EEL LIGHT IS INOP ON HAECO LCQ REF 9298284 SPEC A3N B-53-4-0002. NR GENERATED BY V039704SDR SWAA2020100720864Battery Pack · inoperativeMUPLTIPLE EMERGENCY LIGHTS OUT IN FWD GALLEY. R & R M1674 EMERGENCY LIGHT BATTERY PACK, IAW AMM 33-51-06.SDR SWAA2020100720075Sign · inoperativeRIGHT OVER WING AFT EXIT SIGN INOPERABLE. RELAMPED, IAW AMM 33-51-01.SDR SWAA2020100721150Lens · detachedEXIT/SALIDA SIGN FROM MID-CABIN OVERHEAD DETACHED. REINSTALLED LENS, PER SIP.SDR SWAA2020100721157Cover · incorrectAFT GALLEY EMERGENCY EXIT LIGHT COVER MISSING LETTERING. REPLACED COVER, PER MM 33-51-11.SDR 2020FA0000438Battery Pack · failedDISCREPANCY: FOUND AFT EMERGENCY LIGHT BATTERY FULLY DISCHARGED AND WOULD NOT TAKE CHARGE WHEN POWER ON. CORRECTIVE ACTION: PERFORMED REPLACEMENT OF EMERGENCY LIGHTS BATTERY RIGHT HAND RACK (AFT) WITH MODIFIED UNIT IN ACCORDANCE WITH PHENOM 300 MAINTENANCE MASDR DALA2020100603300Battery Pack · inoperativeEMERGENCY LIGHTS AT ROW 1-3DC AND L1 DOOR ARE INOPERATIVE. CORRECTIVE ACTION: REPLACED FIRST CLASS SEAT EMERGENCY LIGHT AFT BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR UIEA2020100602175Cover · looseL1 EMERGENCY LIGHT COVER LOOSE. REINSTALLED LENS COVER, IAW AMM 33-51-01. OPERATIONS CHECK GOOD.SDR SIMA20201005001Light · inoperativeEMERGENCY LIGHT (IN CEILING) NEAR ROW 13 IS INOPERABLE AND COVER IS MISSING. C/A: R & R CABIN EMERGENCY LIGHT ASSEMBLY AT ROW 13, IAW EMB175 AMM 33-50-13. OPS CHECK FAILED, REF ITEM 2 OF THIS LOG PAGE FOR ADDITIONAL MAINTENANCE.SDR WX0A2020100573585Power Supply · no testL2 & R2 EXIT SIGN LIGHTS INOPERABLE. PERFORMED EPSU SYS TEST AND TSM 33-51-00-810-859-A. REMOVED AND REPLACED EPSU (12WL), IAW AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2020100573584Battery Pack · no testEMERG LIGHTS BATTERY (11WL) FAILED ON CIDS TEST, PER WEEKLY CHECK. REMOVED AND REPLACED EPSU BATTERY PACK (FIN 11WL) ON A/C LEFT, OVER WING. TESTED GOOD, IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A.SDR IPXA2020100560946Battery Pack · dischargedINSPECTION TYPE: NA EMERGENCY BATTERY 1 LOW MESSAGE WHEN EMERGENCY LIGHT TEST RAN. REMOVED AND REPLACED NR 1 EMERGENCY POWER SUPPLY BATTERY, IAW AMM 33-51-01-000-802.SDR SWAA2020101220706Battery Pack · inoperativeAFT OVERWING RT EMERGENCY LIGHT INOPERABLE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK, PER MM 33-51-06. EMERGENCY LIGHTS OPERATIONS CHECKED GOOD, PER MM 33-51-00. P/N OFF D717-01-100 S/N OFF 216952 P/N ON D717-01-100SWA S/N ON 45642.SDR SWAA2020101220703Battery Pack · inoperativeFWD GALLEY RT EMERGENCY LIGHTS INOPERABLE. REMOVED AND REPLACED BATTERY PACK, PER MM 33-51-06. EMERGENCY LIGHTS OPERATIONS CHECKED GOOD, PER MM 33-51-00P/N OFF D717-01-100 S/N OFF 45832 P/N ON D717-01-100-SWA S/N ON 57388.SDR SWAA2020100720006Battery Pack · inoperativeMID AISLE EMERGENCY LIGHT INOPERABLE. R & R EMERGENCY BATTERY POWER PACK, IAW AMM 33-51-06. OPERATIONS CHECK GOOD.SDR SWAA2020100720009Lamp · inoperativeRT FUSELAGE EMERGENCY LIGHT AFT OF CARGO DOOR INOPERABLE. RELAMPED RT FUSELAGE EMERGENCY LIGHT, PER AMM 33-51-04.SDR SWAA2020100720064Light · inoperativeLT AFT ENTRY DOOR EXTERIOR EMERGENCY LIGHT INOPERABLE. RELAMPED LIGHT AFT ENTRY DOOR EXTERIOR EMERGENCY LIGHT, PER AMM 73-51-00. OPERATIONS CHECK GOOD.SDR SWAA2020100720376Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT FWD ENTRY DOOR INOPERABLE. RELAMPED, IAW AMM 33-51-04.SDR DALA2020100603304Rccb · malfunctionedEMERGENCY EXIT LIGHTS ON FROM 1ST CLASS TO DOOR 3 ON NOT ABLE TO RESET. CREW REST EMERGENCY LIGHTS ON. CORRECTIVE ACTION: T/S AND R/R RCCB 102XP, PER A350 A-24-71-57. EPDS TEST PASSED MESSAGE CLEARED EMERGENCY LIGHTTS OPERATIONS NORMAL.SDR IPXA2020100560973Battery Pack · inoperativeINSPECTION TYPE: NA DURING PS1 CK FOUND EMERGENCY LIGHTS INOPERABLE. REMOVED & REPLACED EMERGENCY LIGHTS BATTERY PACK, AS PER 767 MM 33-51-07-201 TASK 022-001/TASK 422-012. OPERATIONS CK GOOD, IPC 33-51-07-41-30.SDR ASAA2020100433271Battery Pack · inoperativeNUMEROUS INTERIOR & EXTERIOR EMERGENCY LIGHTS INOPERABLE. GROUNDED-YES. REPLACED 2 EA BATTERY PACKS LOCATED AT AFT GALLEY CEILING AND APPROXIMATELY ROW 26 CEILING RT SIDE, REF B737-900 AMM 33-51-06.SDR DALA2020100503289Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHT BATTERY AT SEAT 10 DEAD. REPLACED BATTERY, PER B737AMM 33-51, SYSTEM CHECKS OK.SDR AALA202010059001Power Supply · faultedAIRCRAFT IN BASE MAINTENANCE: INTERNAL FAULT OF EMERGENCY BATTERY POWER UNIT. REPLACED EMERGENCY POWER UNIT WITH NEW IAW AMM 33-51-04, OPS CHECK GOOD.SDR AALA202010059004Light · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHTS NOT ARMED LIGHT INOPERATIVE. RE-LAMP EMERGNCY EXIT LIGHTS NOT ARMED KORRY SWITCH PER AMM 33-00-00.SDR DALA2020100503276Battery Pack · no testEMERGENCY SIGN AT R1 DOOR WILL NOT TEST. CORRECTIVE ACTION: REPLACED EMERGENCY BATTERY. SYSTEM OPERATION IS NORMAL.SDR AALA202010059012Power Supply · shortedAIRCRAFT WAS GROUNDED: CIDS CLASS 1 EPSU (13WL) AFT L FAULT OCCURRED DURING THE OPERATION CHECK OF THE EMERGENCY LIGHTING SYSTEM AFTER THE SCHEDULED TIME CHANGE OF THE L3 DOOR SLIDE. FAULT EAS CONFIRMED AS A SHORT CIRCUIT IN THE INTERGRAL LIGHTING OF THE L4 DOSDR AALA202010059011Power Supply · shortedAIRCRAFT WAS GROUNDED: CIDS CLASS 1 EPSU (13WL) AFT L FAULT OCCURRED DURING THE OPERATION CHECK OF THE EMERGENCY LIGHTING SYSTEM AFTER THE SCHEDULED TIME CHANGE OF THE L3 DOOR SLIDE. FAULT EAS CONFIRMED AS A SHORT CIRCUIT IN THE INTERGRAL LIGHTING OF THE L4 DOSDR AALA202010059010Power Supply · shortedAIRCRAFT WAS GROUNDED: CIDS CLASS 1 EPSU (13WL) AFT L FAULT OCCURRED DURING THE OPERATION CHECK OF THE EMERGENCY LIGHTING SYSTEM AFTER THE SCHEDULED TIME CHANGE OF THE L3 DOOR SLIDE. FAULT EAS CONFIRMED AS A SHORT CIRCUIT IN THE INTERGRAL LIGHTING OF THE L4 DOSDR AALA202010059003Power Supply · shortedAIRCRAFT WAS GROUNDED: CIDS CLASS 1 EPSU (13WL) AFT L FAULT OCCURRED DURING THE OPERATION CHECK OF THE EMERGENCY LIGHTING SYSTEM AFTER THE SCHEDULED TIME CHANGE OF THE L3 DOOR SLIDE. FAULT EAS CONFIRMED AS A SHORT CIRCUIT IN THE INTERGRAL LIGHTING OF THE L4 DOSDR VNAA2020100411101Battery · dischargedMULTIPLE INTERIOR EMERGENCY LIGHTS INOPERABLE. REMOVED AND REPLACED NR 2 EPSU BATTERY PACK. OPERATIONS CHECK GOOD AT THIS TIME.SDR YENA2020100900471Battery · failedDURING HEAVY MAINTENANCE, INOPERABLE DOOR FRAME EXIT LIGHT RT SIDE AT FWD GALLEY AREA. RESOLVED ON W/O: 1062723 TASKCARD: NR-00012, REF AEROMAN NR W/O 2020-293/1 WCC 2020-277311. REMOVED AND REPLACED EMERGENCY LIGHT POWER UNIT 1, IAW E190 AMM 33-50-01/400, ASDR SWAA2020100720566Lamp · inoperativeRT FWD EMERGENCY LIGHT INOPERABLE. RELAMPED RT FWD EMERGENCY LIGHT. OPS GOOD, REF AMM 33-51-04.SDR SWAA2020100720602Light · inoperativeL1065 AISLE EMERGENCY LIGHT WILL NOT ILLUMINATE. SA-M 767 NR J0672-1. REMOVED & REPLACED L1065 AISLE LIGHT ASSEMBLY, PER AMM 33-51-03.SDR SWAA2020100720684Battery Pack · inoperativeEMERGENCY LT BATTERY PACK M1675 DEAD. R & R EMERGENCY LT BATTERY PACK MT 1675, PER M/M 33-51-06. OPS CHECK GOOD.SDR UIEA2020100732154Lamp · inoperativeL-1 EXTERIOR EMERGENCY LIGHT INOPERABLE. RELAMPED L-1 DOOR EMERGENCY LIGHT. OPS TEST EMERGERGENCY LIGHT OK, AMM 33-51-00/715.SDR DALA2020100603303Battery Pack · no testDURING SERVICE CHECK EPSU SYS TEST RECEIVED FAULT BAT/EPSU (10WL) FWD L. CORRECTIVE ACTION: REMOVED AND REPLACED FWD LT EPSU BATTERY, PER A321 AMM 33-51. SYSTEM TEST OK.SDR IPXA2020100560958Power Supply · no testINSPECTION TYPE: NA EMERGENCY LIGHTS POWER SUPPLY FAULTING ON BITE TEST. REPLACED POWER SUPPLY, PER AMM 33-50-00-0001.SDR AALA202010049009Light · inoperativeAIRCRAFT WAS GROUNDED: BROKEN SHROUDS ON ESCAPE PATH LIGHT AT SEATS 13C AND 15C. REPLACED EPL RACEWAYS PER COLLINS CMM 25-23-67.SDR FDEA202010032404Battery · failedDURING PREFLIGHT TEST OF EMERGENCY LIGHT SYSTEM GOT LEVEL 1 "EMER LT BAT 1 LO" ALERT. REMOVED & REPLACED EMERGENCY LIGHTING BATTERY/POWER SUPPLY, PER AMM 33-51-01-4. SDR INFO: GRIMES, RECHARGEABLE BAT POWER SUPPLY P/N 60-4411-5, S/N 1172.SDR DALA2020100503273Fuse · failedDURING INSPECTION FOUR EMERGENCY SEAT MOUNTED LIGHTS AT ROW 27-37 INOPERATIVE. CORRECTIVE ACTION: REPLACED FUSE IN POWER SUPPLY M10568. SYSTEM OPERATION IS NORMAL.SDR SIMA20201003001Lamp · inoperativeRT LATERAL PANEL EMERGENCY LIGHT INOPERABLE. C/A: R & R RT EMERGENCY LIGHT LAMP, IAW EMB 140 AMM 33-50-10. OPERATIONS CHECK GOOD.SDR SIMA20201002006Bulb · inoperativeEMERGENCY LIGHT ON RIGHT WING OVERHEAD PANEL INOPERABLE. C/A COMPLETE: R & R EMERGENCY LIGHT BULB ON RIGHT WING OVERHEAD PANEL, IAW EMB 145 AMM 33-50-10. OPERATIONAL CHECK OK.SDR SWAA2020101920512Battery Pack · inoperativeEMERGENCY EXIT LIGHTS COMMON TO BATTERY PACK M1669 ARE INOPERABLE. REMOVED & REPLACED BATTERY PACK M1669, PER AMM 33-51-06-960-805 AND AMM 33-51-00-710-801. 59924C 06OCT20 PERFORMED GOOD OPERATIONAL TEST.SDR SWAA2020101920510Battery Pack · inoperativeEMERGENCY EXIT LIGHTS COMMON TO BATTERY PACK M1672 ARE INOPERABLE. REMOVED & REPLACED AND OF BATTERY PACK M1672, PER AMM 33-51-06-960-805 AND AMM 33-51-00-710-801 59924C 06OCT20. PERFORMED GOOD OPERATIONAL TEST.SDR CALA2020100701157Battery · discharged767 - RETURN TO A SERVICEABLE CONDITION AFTER ACTIVE STORAGE PROGRAM - EMERGENCY EXIT LIGHTS INOP ROWS 20 THRU 23 FOUND EMERGENCY BATTERY CHARGER HAS CORROSION AND POWER SUPPLY BATTERY COULD NOT RECHARGE. LOCATION IS BEHIND VENT GRILL BELOW R/H OVERWING EMERGSDR IPXA2020100661024Power Supply · no testINSPECTION TYPE: NA AFTER CHANGING EPSU BATTERY FOR CAPACITANCE DUE DATE CHECK EPSU WOULD NOT TEST. REPLACE EPSU, PER AMM 33-51-14-0401. OPERATIONS CHECKS GOOD.SDR YENA2020100200467Light · malfunctionedFLT 210 PAP-FLL. EMERGENCY OVERHEAD SIGNS WILL NOT EXTINGUISH AFTER T/O EVEN WITH SWITCH IN OFF POSITION. UPON INSPECTION FOUND CIDS2 FAULT ON STATUS PAGE. RESET CIDS EMERGENCY LIGHTS EXTINGUISHED. PERFORMED TEST, NO DEFECTS NOTED. TEST OK, IAW AMM 23-73-
Back to JASC 3350