SDR SIMA202007076004Light · inoperativeEMERGENCY LIGHTING SYSTEM, FLOOR PROXIMITY STRIP AT SEAT 12A WAS INOPERATIVE. R & R FLOOR PROXIMITY STRIP LIGHTS AT SEAT 12A. OPS CHECKED GOOD IAW AMM 33-50-12.SDR ASAA2020070762875Battery Pack · dischargedLEFT FWD EXTERIOR EMERGENCY LIGHT INOPERATIVE. GROUNDED - YES. REMOVED AND REPLACED THE LT POWER SUPPLY BATTERY PACK IAW AMM 33-51-06. CHARGED BATTERY PACKS IAW AMM 33-51-06-610-802. SYSTEM CHECKED GOOD.SDR IPXA2020070767423Battery Pack · inoperativeINSPECTION TYPE:N/AEMERGENCY LIGHT ADVISORY MESSAGE ILLUMINATED W/ EMERGENCY LIGHT SWITCH "ARMED"REPLACED UPPER DECK EMERGENCY LIGHT BATT PACK IAW 747 AMM 33-51-04 OP CHECK GOOD ESR: IPC 24-31-00-50 IPXA20200706 57399SDR SIMA202007076003Power Supply · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R THE LT EXTERIOR OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A, AND 33-50-10-400-801-A. NO FIX. R & R THE NR 4 EMERGENCY LIGHTING SYSTEM POWER SUPPLY IAW WORK CARD 33-700-19. OPS CHECKED GOOD.SDR MASA2020070610118Light · inoperativeOVRHD CEILNG EMERG EXIT LIGHT ROW 5 INOP. REPLACED BULB.SDR SWAA2020070897696Light · inoperativeAFT ENTRY EXTERIOR EMERGENCY LIGHT INOP. REPLACED IAW MM 33-51-04 OPS CHECK GOOD.SDR SWAA2020070898108Lens · unsecureEMERGENCY EXIT LENS CAME OFF. LOWER LENS AT RT OVERWING EXIT ON WALL. REINSTALLED LENS PER MM 33-51-11.SDR DALA2020070762552Lock · brokenAFT RIGHT ECONOMY CLASS INSEAT EMERGENCY LIGHTS ARE INOPERATIVE. FOUND BATTERY PACK CHARGER LOCK ON M33401 BROKEN. REPLACED CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2020070762547Cover · unsecureEMERGENCY EXIT SIGN COVER LOOSE AT THE R2 DOOR. SECURED EXIT SIGN COVER.SDR IPXA2020070657352Battery · dischargedINSPECTION TYPE:C2 FOUND L1 DOOR EMERGENCY LIGHT INOP. IAW AMM 33-51-04-902-001-001 REV 98.01 REPLACED THE EMERGENCY LIGHT BATTERY M5170 AT U/D STA 550 WL323 LBL83. IAW AMM 33-51-04-902-001 REV 98.01 PERFORMED EMERGENCY LIGHT BATTERY OPERATION TEST, RESULT WSDR R61A2020070900559Power Unit · failedAFT RT INBOARD EMERGENCY LIGHT POWER UNIT FAILED. R&R AFT RT IB EMERGENCY LIGHT POWER UNIT.SDR R61A2020070900558Power Unit · failedAFT RT OUTBOARD EMERGENCY LIGHT POWER UNIT FAILED. R&R AFT OUTBOARD EMERGENCY LIGHT POWER UNIT.SDR R61A2020070900557Power Unit · failedFWD RT EMERGENCY LIGHT POWER UNIT FAILED. PERFORMED FULL CHARGE OF FWD RT EMERGENCY LIGHT POWER UNIT.SDR ASAA2020070832879Battery Pack · failedRT FWD CABIN EMERG LIGHT FAILED TIME CHECK. LOCATION M1676 LT EMERG EXIT DOORS FAILED TIME CHECK LOCATION M1694. GROUNDED - YES. REMOVED AND REPLACED BATTERY PACK M1676 REF AMM 33-51-06 OPS CK GOOD. CHANGED BATTERY M1694 REF AMM 33-51-06 OP CK GOOD.SDR SWAA2020070797644Power Supply · faultyEMERGENCY LIGHTS ASSOCIATED WITH M1674 BATTERY CHARGER GO OUT 20 SECONDS AFTER EMERGENCY LIGHT SWITCH IS TURNED ON. REMOVED, REPLACED, AND PERFORMED A GOOD FUNCTIONAL TEST OF M1674 POWER SUPPLY IAW AMM 33-51-06-960-806, STEP 5.E. 1, 2A, 3, 4A, B, 1C, AND 5ASDR DALA2020070762549Battery Pack · inoperativeEMERGENCY EXIT LIGHT OVER WING LEFT SIDE IS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020070762548Battery Pack · inoperativeEMERGENCY EXIT LIGHT SIGN AT P12 INOPERATIVE. REPLACED BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA2020070602550Fuse · failedON SERVICE CHECK FOUND CREW REST FLOOR PROXY EMERGENCY LIGHTS AND L1 DOOR EXIT IDENTIFIER INOPERATIVE. REPLACED F3 FUSE AT M33093 EMERGENCY POWER SUPPLY. FOUND SHORT TO GROUND AT PIN 13. REMOVED 2ND STEP ACCESS PANEL IN THE CREW REST. LOWER THE PANEL ABOVE L1 SDR UIEA2020070751286Light · no testMAIN DECK L1 DOOR SILL EMERGENCY LIGHT L1853 FAILED OPERATION TESTMAIN DECK L1 DOOR SILL EMERGENCY LIGHT L1853 REPLACED AND TESTED NORMAL AS PER AMM 33-51-05SDR ASAA2020070632864Battery Pack · dischargedRT EMERGENCY EXIT LIGHTS GO OUT IMMEDIATELLY AFTER LIGHTS ARE TURNED ON. GROUNDED - YES. REPLACED BATTERY PACK PER AMM 33-51-06-960-805. OPS CHECKED GOOD.SDR IPXA2020070657369Power Supply · inoperativeINSPECTION TYPE:N/A EMERGENCY LIGHT OVER L1 DOOR DOES NOT STAY ON. REMOVED AN REPLACED POWER SUPPLY ON LIGHT OVER L1 DOOR REF AMM 33-51-07-862-059 AN 33-51-07-022-000, OPS CHECK GOOD.SDR R61A2020070600552Battery · dischargedAFT RT EMERGENCY LIGHT REMAINS ILLUMINATED AT AIRCRAFT POWER DOWN. CHARGED BATTERY IAW AMM 33-50-00.SDR CALA2020070401042Battery Pack · low voltageBATTERY PACKS M1674, M1694,M1670 & M1673 FAILS BATTERY CAPACITY CHECK REF 29-1012-1-5801. NEED BATTERY PACK 99-3351-3-0015. REMOVED DADO PNL FROM M1694 AND M1670. REPLACED BATTERY PACK AT M1670 REF AMM 33-51-06-960-805. NEEDS TO BE OPS CHECKED. ACPD IDT ISDR CALA2020070401039Light · inoperativeLEFT AFT, OVER WING EXTERIOR EMERGENCY EGRESS LIGHT INOP. FOUND OTHER LAMP LOOSE AND UNSECURED IN SOCKET REPLACED LAMP REF MM 33-51-00 OPS CHECK GOOD.SDR CALA2020070401037Light · inoperativeRIGHT SIDE FORWARD OVERWING EMERGENCY EXIT LIGHT IS NOT WORKING. RELAMPED LIGHT ASSY. LIGHT GROUND CHECKS GOOD VERIFIED INSTALL AND OPS CHECK.SDR J7SA2020072300209Battery · not reportedDISCOVERED EMERGENCY LIGHTS REMAIN ON WITH SWITCH IN THE ARM POSITION. REMOVED AND REPLACED FORWARD AND AFT EMERGENCY BATTERIES IAW AMM 33-52-01. OPS CHECK GOOD.SDR SWAA2020070997892Light · inoperativeFWD SERVICE DOOR EMERGENCY EXIT LOCATOR SIGN HAS SEVERAL LIGHTS OUT. RELAMPED FWD SERVICE DOOR EMERGENCY EXIT LOCATOR SIGN AND PERFORMED GOOD FUNCTIONAL TEST AS PER AMM 33-51-01-960-801.SDR DALA2020070302554Light · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHT ABOVE 30C OVERHEAD BIN INOPERATIVE. FWD TO MEL 33-00-15A. PLAC INSTALLED.SDR YENA2020070700383Battery · no testDURING BATT CAPCITANCE CHECK AFT L BAT EPSU FAULTED; R & R AFT EPSU BATT FIN# 13WL REF 33-51-38 OPS CHK GOOD.SDR N6WA2020070301Light · inoperativeEMERGENCY LIGHTS WON'T COME ON. DEFERRED EMERGNCY LIGHTS ON OPEN CONTROL 70069485 PER MEL 33-51-01A CAT A. AUTHORIZED BY MXCSDR R61A2020070700553Power Supply · no testFWD RT ELPU FAILED TEST. R & R FWD RT ELPU.SDR SIMA202007073001Charger · inoperativeREMOVED AND INSTALLED EMERGENCY LIGHT BATTERY CHARGER IAW AMM 33-50-04. OPS CHECKED GOOD. EMERGENCY LIGHT CHARGER.SDR DALA2020070762545Battery Pack · inoperativeFOUND THE RT OVERWING EMERGENCY EXIT SIGNS INOPERATIVE. R & R THE BATTERY PACK M10568 IAW AMM 33-51.SDR R61A2020070600551Power Unit · inoperativeEICAS MESSAGE EMERGENCY LIGHT BATTERY FAULT. R&R EMERGENCY LIGHT POWER UNITS 1 AND 2.SDR AALA2020070549004Housing · detachedAIRCRAFT NOT GROUNDED - RED EXIT ROW SEAT LIGHT (16C) HOUSING DETACHED. REATTACHED AND SECURED EMERGENCY LIGHT ASSEMBLY PER AMM 33-51-01, OPERATIONAL CHECK OKAY.SDR MASA2020070310116Light · inoperativeROW 11 CEILING EMERGENCY FLOOD LIGHT INOP, PLACED ON MEL.SDR MASA2020070310115Light · inoperative2 CEILING EMERGENCY FLOOD LIGHTS INOP, RELAMPED.SDR R61A2020070900560Power Supply · inoperativeSUPPLEMENTAL INFORMATION: EMERGENCY LIGHT BATTERY FAULT. R&R FWD LT EMERGENCY POWER SUPPLY.SDR SWAA2020070797656Lamp · inoperativeEMERGENCY EXIT LIGHTS L1187 ON FWD LAV & L1191 ON AFT GALLEY HAVE BULBS OUT. REPLACED THE LAMPS AND PERFORMED A GOOD FUNCTIONAL TEST IAW AMM 33-51-01-960-801, STEP 2C.(1)(A)1);4)(C);(2) AND (4).SDR SWAA2020070797496Bulb · inoperativeLEFT OVERWING OUTER EXIT LIGHT WAS OUT. REMOVED AND REPLACED THE BULB AND PERFORMED AN OPS CHECK IAW AMM 33-51-04-960-801. CHECKED GOOD.SDR SWAA2020070697202Battery · failedEMERGENCY LIGHT BATTERIES FAILED CAPACITY CHECK AT LOCATIONS M01672; M01669; M01675 AND M01674. REMOVED AND REPLACED EMERGENCY LIGHT BATTERIES AT LOCATIONS M01672; M01669; M01675 AND M01674 PER AMM 33-51-06.SDR SWAA2020070697642Battery Pack · dischargedEMERGENCY EXIT LIGHTS WILL NOT STAY ILLUMINATED. REMOVED AND REPLACED M1669 POWER SUPPLY AND BATTERY PACK AT STA 603 WL 212 RBL 67 AND REMOVED AND REPLACED M1673 BATTERY PACK AT STA 952 WL 290 LBL 13; PERFORMED GOOD INSTALLATION TEST OF M1669 AND M1673 AS PERSDR DALA2020070602542Charger · inoperativeDURING SERVICE CHECK FOUND LT EMERGENCY LIGHTS NOT FUNCTIONING AT OVERWING EXIT. REMOVED AND REPLACE LT BATTERY PACK CHARGER PER AMM 33-51.SDR REXA2020070600593Light · inoperativeFWD CEILING EMERGECNY LIGHT OUT. REMOVED AND REPLACED FORWARD CEILING EMERGENCY FLOOD LIGHT IAW AMM 33-51-16. OPS CHECK GOOD.SDR R61A2020070600550Power Unit · dischargedEMERGENCY LIGHTS OVER L1 R1 DO NOT ILLUMINATE. PERFORMED FULL CHARGE OF ELPU IAW AMM 33-50-01.SDR R61A2020070600549Power Unit · inoperativeEMERGENCY LIGHTS AT CENTER CEILING PANEL IN AFT GALLEY DO NOT ILLUMINATE. R&R NR 4 ELPU.SDR AALA2020070549003Power Supply · inoperativeAIRCRAFT NOT GROUNDED - EMERGENCY POWER SUPPLY UNIT 15WL INOPERATIVE. REMOVED AND REPLACED 15WL EPSU (EMERGENCY POWER SUPPLY UNIT) PER AMM 33-51-38, OPERATIONAL CHECK OKAY.SDR CALA2020070401036Battery · dischargedEMERGENCY LIGHT TEST FAILS FOR ESPU BATTERY EMER R PER NR 9298007. REMOVED AND REPLACED 12WL BATTERY IAW AMM 33-51-38-000-002- A AND 33-51-38-400-002-A. OP CHECK GOOD IAW AMM 33-51-00-71 0-001-A.SDR VNAA2020070411101Epsu · inoperativeEXIT SIGNS AT ROW 8 AND 16 INOP. REMOVED AND REPLACED EPSU BATTERY PACKS NR 2 AND NR 4. OPS CHECK GOOD ON NR 4 OPS CHECK BAD ON NR 2. INSPECTED AND FOUND PIN LOOSE ON CONNECTOR 347 FOR EMERGENCY LIGHTS, REINSERTED PIN. OPS CHECKS GOOD. (NR2 EPSU P/N:AD201SDR WX0A2020070373521Battery · failedEMERGENCY LIGHT BATTERY FIN 11WL FAILED CAPACITY CHECK. REPLACED EMERGENCY LIGHT BATTERY FIN 11WL IAW AMM 33-51-38. OPS CHECK GOOD.
Back to JASC 3350