SDR UIEA2014062700280Wire · damagedMULTIPLE AREAS OF EMER PATHWAY LIGHTING WIRES DAMAGES. REPAIRED EMER FLOOR PATH LIGHTING IN ACFT CABIN AREA AS REQUIRED IAW AMM 33-51-00 & SWPM 20-10-13. PERFORMED SATISFACTORY OPERATIONS TEST IAW AMM 33-51-07-612-035.SDR AALA20140630011Connector · brokenSEAT 34B EMER LIGHT INOPERATIVE. REPLACED BROKEN LIGHT CONNECTOR AT SEAT 34B. OPERATIONS CHECKED NORMAL.SDR DALA2014063003840Wire · damagedFOUND ASILE EMERGENCY EXIT LIGHTS INOPERATIVE AT ROWS 19-24. FOUND BAD SPLICE AT ROW 24. REPAIRED IAW SWPM 20-10-30.SDR AALA20140626006Connector · unsecureEMERGENCY LIGHT AT SEAT 5B INOPERATIVE. RESEATED CONNECTOR FOR EMER LIGHT AT SEAT 5B. OPERATIONS CHECKED NORMAL.SDR VNAA2014062500021Wire · shearedCREW REPORTED FLOOR EMERGENCY LIGHTS AFT OF ROW 8 DID NOT ILLUMINATE. MAINTENANCE INSPECTED AND FOUND WIRES SHEARED OFF AT PIGTAIL ADJACENT TO LAVATORY. MAINTENANCE REPAIRED WIRING AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR CALA2014062791360Connector · disconnectedIAW A CHECK, SEAT 60H, SEAT EEL INOPERATIVE. FOUND CONNECTOR DISCONNECTED AT LAMP.SDR CALA2014062791359Pin · backed outIAW A CHECK, SEAT EEL AT 35A, INOPERATIVE. FOUND ONE PIN PUSHED IN AT CONNECTOR COMING FROM FWD SEAT.SDR DALA2014062603784Wire · brokenDURING NON-ROUTINE CHECK, FOUND SEAT 4 ABC EMERGENCY LIGHT OUT. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECKED NORMAL.SDR SIMA20140624003Pin · backed outSERVICE DOOR EXTERNAL EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EXTERNAL EMER LIGHT LAMP IAW TASK 33-50-10-000-801-A & TASK 33-50-10-400-801-A,OPERATION CHECK, NO FIX. CONFIRMED POWER IS GETTING TO ASSEMBLY THROUGH QUICK DISCONNECT WIRES. FOUND PIN PUSHED SDR DALA2014062303690Wire · openFOUND FOUR FLOOR PROXIMITY EMERGENCY LIGHTS WOULD NOT TURN ON. FOUND OPEN WIRE BESIDE SEAT 43ABC FLOOR. REPAIRED THE WIRE WITH SPLICE IAW SWPM.SDR DALA2014062703808Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THE EMERGENCY EXIT LIGHTS AT 35DE WERE INOPERATIVE. MAINTENANCE FOUND WIRE HARNESS IN POOR CONDITION AND REPLACED. OPS CHECKED NORMAL.SDR DALA2014062503779Connector · disconnectedDURING OVERNIGHT CHECK, FOUND EMERGENCY ESCAPE LIGHTING INOPERATIVE ON ROWS 28-37. FOUND CONNECTOR DISCONNECTED BEHIND AIR RETURN GRILL AT 33 DEF AND CONNECTED, LIGHTS OPS CHECKED GOOD.SDR REXA2014062200626Connector · unsecureCABIN FLOOR EMER LIGHTING NOT ILLUMINATING AFT OF THE OVERWING EMERGENCY EXIT. SECURED EMER LIGHTING CONNECTOR AT AFT END IAW AMM 33-51-01. LIGHT OPERATIONS CHECKED GOOD OK FOR SERVICE.SDR SWIA201438298Connector · brokenEMERGENCY EXIT SIGN DOES NOT ILLUMINATE. SIGN IS LOCATED NEAR MAIN CABIN DOOR. FOUND A WIRE CONNECTOR ON THE MAIN CABIN DOOR EMERGENCY EXIT SIGN BROKEN. INSTALLED NEW CONNECTOR IAW ESPM. OPS CHECKS GOOD.SDR DALA2014062303685Connector · disconnectedCABIN EMERGENCY LIGHT INOPERATIVE AT FWD CABIN BULKHEAD. FOUND LIGHT ASSY CONNECTOR DISCONNECTED. RECONNECTED CONNECTORS IAW AMM 33-51. OPS CK GOOD.SDR DALA2014062303683Connector · unsecureDURING NON ROUTINE CHECK, FOUND SEAT 16C WHITE EMERGENCY LIGHT INOPERATIVE. MAINTENANCE FOUND AND REPAIRED LOOSE CONNECTION AT SEAT 16 AND FUNCTIONAL CHECK WAS NORMAL.SDR IPXA2014062783432Connector · damagedPREFLIGHT-EVAC SLIDE WARNING LIGHT INOPERATIVE. R & R CONNECTOR FOR ASPSU IAW MM 52-73-18-401. TESTED NORMAL IAW MM 52-73-00-501.SDR DALA2014062603787Connector · disconnectedEMERGENCY LIGHT AT 4C INOPERATIVE, RECONNECTED CONNECTOR AND REPLACED BULB IAW AMM 33-51.SDR ASOA2014062510758Wire · disconnectedRIGHT EMERGENCY EXIT FLOOR FLOOD LIGHT INOPERATIVE. RECONNECTED FLOOD LIGHT IAW AMM 33-51-19, OPS CHECKED GOOD.SDR ASOA2014062510757Wire · damagedPAX DOOR FLOOR EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. REPAIRED WIRE IAW ESPM 20-17-31, OPS CHECKED GOOD.SDR DALA2014062303688Wire · brokenESCAPE SLIDE LIGHT DOES NOT OPERATE PROPERLY. REPAIRED BROKEN WIRE 3351-5021.SDR DALA2014062203682Connector · unsecureDURING NON ROUTINE CHECK, FOUND EMERGENCY EXIT LIGHTS ON RT SIDE OF ACFT AND EXIT PATHWAY LIGHTS ARE BLINKING. MAINTENANCE RESEATED CONNECTOR ON EMERGENCY POWER SUPPLY UNIT FOR RT OVERWING EMERGENCY EXITS AND FUNCTIONAL CHECK WAS NORMAL.SDR SWIA201438330Connector · unsecureEMERGENCY LIGHT EXIT SIGN ON THE WARDROBE DOES NOT WORK. C-CHECK, RESEATED CONNECTORS OP CHECKED GOOD IAW AMM.SDR SWIA201438329Connector · out of positionEMERGENCY LIGHTS EXIT SIGN ON THE GALLEY TRIM PANEL DOES NOT WORK. C-CHECK, REPOSITION WIRE CONNECTORS TO PROPER LOCATION IAW AMM.SDR SWIA201438328Connector · out of positionEMERGENCY LIGHT EXIT SIGN ON THE SERVICE DOOR TRIM PANEL DOES NOT WORK. C-CHECK, REPOSITION WIRE CONNECTORS TO PROPER LOCATION IAW AMM.SDR SWIA201438327Connector · unsecureEMERGENCY LIGHTS RIGHT EMERGENCY DOOR AFT EXTERIOR LIGHT DOES NOT WORK. C-CHECK, RESEATED CONNECTORS, OPS CHECK GOOD IAW AMM.SDR REXA2014061900607Pin · not seatedTASK CARD 900-25-900-910 CEILING EMER LIGHT AT ROW 13 ABCD IS INOPERATIVE. RESEATED CONNECTOR PINS PROVIDING GNDS TO DS 192P1 2 IAW ESPM 20-16-00. PERFORMED OPERATIONAL TEST IAW AMM 33-51-00-710-802-A16. ALL EMER LIGHTS CHECKED GOOD WITH EXTERNAL ELEC POWERSDR USAA2014062000014Connector · disconnectedSEAT EMER LIGHTS INOPERATIVE ROWS 6L & 10L. FOUND CONNECTORS 7260-VC4 & 7261-VC3 DISCONNECTED. RECONNECTED CONNECTORS AT ROWS 6L & 10L.SDR SIMA20140619004Connector · disconnectedFORWARD CABIN AFT GALLEY EXIT SIGN INOPERATIVE. PERFORMED TROUBLESHOOTING, FOUND CONNECTOR P8530 DISCONNECTED AT NR 2 EMER LIGHT BATTERY ASSEMBLY. SECURED CONNECTOR IAW WM CHAPTER 20-50-00, OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.SDR AALA20140624013Connector · not seatedEMERGENCY LIGHT AT SEAT 8D INOPERATIVE. RESEATED CONNECTOR FOR EMER LIGHT AT SEAT 8D. OPERATIONS CHECKED NORMAL.SDR AALA20140618007Wire Harness · unsecureWIRE HARNESS HANGING DOWN UNDER SEAT 21D. SECURED WIRE HARNESS TO ESCAPE PATH LIGHT AT SEAT 21D. OPERATIONS CHECKED NORMAL.SDR ASOA2014062310712Connector · brokenEXIT LIGHT WIRE CONNECTOR BROKEN AT SEAT 1 A/B PCU. INSTALLED CONNECTOR FOR EMERGENCY EXIT LIGHT AT SEAT 1A/B PCU IAW ESPM 20-17-31. OPS CHECKED GOOD IAW AMM 33-51-00.SDR ASOA2014062310711Connector · brokenWARDROBE LOWER EXIT LIGHT WIRE CONNECTOR BROKEN. R & R CONNECTOR IAW ESPM 20-17-31. OPS CHECKED GOOD IAW AMM 33-51-04.SDR DALA14036530635Wire Harness · damagedSEAT 41DE EMERGENCY LIGHT INOPERATIVE. REPLACED SEAT 41DEF EMERGENCY LIGHT HARNESS IAW AMM 33-51.SDR DALA2014062003674Connector · looseDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATH LIGHT WAS OUT AT SEAT 28. MAINTENANCE FOUND A LOOSE HARNESS AND RECONNECTED THE HARNESS AND THE LIGHTS RETURNED TO AN OPERATIONAL STATE.SDR 29GA2014061900001Wire · detachedEMERGENCY LIGHTS ROW 3-4 DETACHED AND INOPERATIVE. REPAIRED WIRE AT EMERGENCY LIGHTS ROW 3-4 OPS CHECK GOOD.SDR 29GA2014061600001Wire · detachedEMERGENCY LIGHTS ROW 3-4 DETACHED AND INOPERATIVE. REPAIRED WIRE AT EMERGENCY LIGHTS ROW 3-4 OPS CHECK GOOD.SDR SWIA201438736Wire · brokenTHE FWD CONNECTION FOR THE FLOOR LEVEL EMERGENCY LIGHTS HAS A BROKEN WIRE. C-CHECK, REPAIRED BROKEN WIRE IAW WDM.SDR ASOA2014071110855Wire · brokenEMERGENCY LIGHTS FAILED OPS CHECK IAW AMM 33-51-00-710-802. FOUND BROKEN WIRE PZA-L6014-20N. SPLICED WIRE IAW ESPM 20-44-00. OPS CHECK GOOD IAW AMM 33-51-00-710-802.SDR CALA2014061691290Feeder Cable · defectiveIAW A CHECK, AFT GALLEY EEL, TWO EACH INOPERATIVE. REPLACED FEEDER CABLE AT DOOR 4L IAW SSM 33-51-05, LIGHT OPERATIONS NORMAL.SDR CALA2014061600751Connector · disconnectedSUPPORT TASK SEAT ROW 22 ABC EMER PATHWAY LIGHT INOPERATIVE ON INBD CHECK. TROUBLESHOOTING FOUND CONNECTOR DISCONNECTED AT LIGHT ASSEMBLY. IAW PERFORMED CHECK OF EMER LIGHTS WITH CONNECTOR SECURED IAW MM 33-51-11-960-801. LIGHT CHECKED GOOD.SDR CALA2014061691278Wire · damagedFORWARD CABIN EWIS RED & BLACK WIRES DAMAGED AT SEAT TRACK ROW 12 LT. REPAIRED RED & BLACK EMER LIGHT WIRES DAMAGED AT SEAT ROW 12 LT IAW ESPM 20- 53-21. INSULATION WAS DAMAGED ON WIRES FROM CONNECTOR 7260VC5-A 3330-0872-1673-18N & 3330-08702-1673-18.SDR DALA14035889000Connector · unsecureDURING LINE CHECK, MAINTENANCE FOUND THE EMERGENCY LIGHTS INOPERATIVE FROM ROWS 31 TO 36. MAINTENANCE SECURED A LOOSE CONNECTOR AND THE LIGHTS WERE OPERATIONAL.SDR SIMA20140613002Connector · unsecureEMER LIGHT ABOVE SERVICE DOOR INOPERATIVE. FOUND LOOSE CONNECTION, SECURED CONNECTION. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR USAA2014061300007Wire Harness · shortedEMERGENCY LIGHTS INOPERATIVE. REPLACED SHORTED SEAT WIRE HARNESS 5409VB IAW CMM 25-28-99. INSTALLED SERVICEABLE EPSU 11WL IAW AMM 33-51-38-400-001-A. EMERGENCY LIGHTS OPS TESTED SATISFACTORY IAW 33-51-00-710-001-A.SDR USAA2014061300028Wire Harness · unsecureOVERHEAD EMER LIGHT ROW 27 INOPERATIVE. SECURED WIRE HARNESS FOR OVERHEAD EMER LIGHT ROW 27.SDR CALA2014061391266Wire · brokenRIGHT MID LAVATORY MS4 EEL LIGHT STRIP HAS BROKEN WIRES. R & R RT MID LAVATORY EEL LIGHT STRIP IAW AMM 3 3-51-10, OPERATIONS CHECK GOOD.SDR CALA2014061391265Connector · looseEMERGENCY LIGHTS ON SEATS 36B & 33J INOPERATIVE. TROUBLE SHOT & FOUND EMER EXIT LIGHTING CONNECTORS LOOSE AT SEAT ROWS 36AB & 33JK. SECURED & OPERATIONS CHECKED IAW AMM 33-51-00.SDR SWIA2014061338148Connector · unsecureLOWER EMERGENCY DOOR EMERGENCY LIGHT ON RT SIDE INOPERATIVE. SECURED WIRE CONNECTOR ON EMERGENCY LIGHT AT RT OVERWING EMERGENCY DOOR. EMERGENCY LIGHT OPS CHECKED GOOD.SDR SIMA20140611002Wire · damagedEMER LIGHTS ARMED MSG INTERMITTENTLY. FOLLOWED FIM TASK 33-50-00 FOUND WIRE SHIELDING ON WIRES OF ATT CONTROL PANEL EXPOSED. REPAIRED WIRES IAW 20-21-00 WM 33-50-50- OPERATIONS CHECKED GOOD.
Back to JASC 3397