JASC 3397
Service difficulty reports · 22,670
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 0203906306Wire · damagedDURING LINE CHECK, FOUND RIGHT (D) ZONE FLOOR EMERGENCY PATH LIGHTS INOPERATIVE. REPAIRED WIRING AND OPERATIONALLY CHECK GOOD.SDR AALA20021711Wire · brokenLAX - DURING OVERNIGHT MAINTENANCE, GALLEY PARTITION EMERGENCY EXIT PATH LIGHTS BROKEN. REPAIRED BROKEN GALLEY PARTITION EMERGENCY EXIT PATH LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR COEA0201702Wire · brokenAIRCRAFT RETURNED TO BASE AFTER FIRST OFFICER REPORTED SMELL OF SMOKE IN COCKPIT. MAINTENANCE PERSONNEL REPAIRED BROKEN WIRE THAT CONTROLS LIGHTING TO VERTICAL SPEED INDICATOR (VSI). (M)SDR AALA20021688Wire · brokenMIA - DURING OVERNIGHT MAINTENANCE, SEAT MOUNTED EMERGENCY LIGHT WIRE AT SEAT 30G BROKEN. REPLACED SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR SWIA200211509Wire · brokenEMERGENCY LIGHTS AT MAIN DOOR INOPERATIVE. REPAIRED WIRE. OPS CHECK GOOD.SDR C1HA200295013Wire · brokenEMERGENCY FLOOR TRACK LIGHTING INOPERATIVE FROM NR 1 GALLEY TO SEAT ROW 8DEF. REPAIRED BROKEN WIRE AT SEAT ROW 7DEF FLOOR TRACK LIGHT. OPS CHECK GOOD, OK FOR SERVICE.SDR 2003F00164Wire · brokenEMERGENCY ESCAPE PATH LIGHT ROW 5 BROKEN WIRE IN LAMP MODULE. REMOVED AND REPLACED LAMP MODULE IAW DHC-8 MM 33-52-22 PAGE 201 AND 202. OPS CHECK GOOD. (M)SDR USAABB02192Wire · looseFRA - FOUND EMERGENCY FLOOR LIGHTING INOPERATIVE AT RIGHT MID LAVATORY. MAINTENANCE RECONNECTED A LOOSE WIRE. (M)SDR SWIA200211508Wire · brokenEMERGENCY LIGHTS AT OVERHEAD BIN 9C INOPERATIVE. REPAIRED BROKEN WIRE BY FORWARD HINGE OF OVERHEAD BIN ASSY AT 9BC. OPS CHECK GOOD.SDR 02324309Wire · damagedDURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE FORWARD SECTION OF THE EMERGENCY FLOOR TRACK LIGHTING WAS INOPERATIVE. MAINTENANCE PERSONNEL REPAIRED A BROKEN WIRE AT THE FORWARD EMERGENCY FLOOR TRACK LIGHT. AN OPERATIONAL CHECK WAS SATISFACTORY AND SDR GJQ2002F00004Wire · shortedAIRCRAFT RETURNED WITH RT LANDING LIGHT INOPERATIVE. INVESTIGATION REVEALED OPEN CIRCUIT IN WIRING. DISCOVERED TERMINAL BURNED AND OVERHEATED AT TERMINAL JUNCTION. SUSPECT HIGH RESISTANCE AT TERMINAL JUNCTION.SDR ASAA0280582Wire · brokenLAS - DURING PREFLIGHT CHECK, THE EMERGENCY TRACK LIGHTING IN FIRST CLASS CABIN WAS INOPERATIVE. REPAIRED BROKEN WIRE. LIGHTS THEN OPERATED PROPERLY. (M)SDR UPS02439914Wire · damagedINSPECTION TYPE: PFLT, UPPER DECK PASSENGER AREA 3 EA CEILING EMERGENCY LIGHTS INOP. REF L/P 914473, M249145. REPAIRED GROUND WIRE W894-L4734-20 PULLED FROM SOCKET CONTACT AT D5127P. TEST OK. THIS CLEARS M249145SDR AALA20021648Wire · damagedDFW - DURING EMERGENCY, EXIT FLOOR PATH LIGHT STRIP AT SEAT 8D INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CA021121006Splice · overheated(CAN) BURNING ODOR IN CABIN AROUND ROW 11 & 12 OVERHEAD BIN AREA. ODOR DISSIPATED WHEN CABIN LIGHTING WAS TURNED OFF. MAINTENANCE DISCOVERED BURNED PIDC SPLICES OVER PASSENGER SERVICE UNIT NR 4 (RT FWD). SEVERAL SPLICES WERE REPLACED ON BIN HARNESS USING SPLSDR 2002UALA01728Cable · inoperativeEMERGENCY EXIT LIGHTING FROM ROW 15 TO THE END OF CABIN IS INOPERATIVE. EEL POWER STRIP CABLE ASSY INOPERATIVE.SDR AALA20021620Contactor · inoperativeORD - DURING OVERNIGHT MAINTENANCE, LEFT AFT EMERGENCY EXIT SIDE WALL LIGHT INOPERATIVE. RE-SOLDERED BULB RECEPTACLE CONTACT AT LEFT AFT EMERGENCY EXIT SIDE WALL LIGHT. SYSTEM GROND CHECKED NORMAL OPERATION. (M)SDR RAIA00211316Connector · disconnectedFWD ESCAPE PATH LIGHTS INOPERATIVE. RE-SECURED FORWARD FLOOR EMERGENCY LIGHTING STRIP CONNECTOR, OPS CK OK.SDR AALA20021615Wire · damagedLAX - DURING OVERNIGHT MAINTENANCE, RIGHT EMERGENCY LIGHT BY FORWARD GALLEY INOPERATIVE. REPAIRED WIRE AT EMERGENCY EXIT LIGHT AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ASAA0210292Splice · brokenSEA - DURING EMERGENCY FLOOR TRACK LIGHTING IN THE FORWARD CABIN WILL NOT TEST. REPLACED BROKEN WIRE SPLICE AT ROW 9, THEN LIGHTS TESTED NORMAL. (M)SDR CALA0200541Connector · faultyINSPECTION FOUND R-2 DOOR EMERGENCY EXIT SIGN INOPERATIVE. THE WIRE BETWEEN R-2 DOOR AND EMERGENCY EXIT SIGN AND REMOVABLE SPLICE CONNECTOR WERE FOUND AT FAULT. PIN CONTACT AND SPLICE CONNECTOR WERE REPLACED IAW WIRING MANUAL 20-30-12. THE CONNECTOR WAS REFITTSDR CALA0200540Wire · defectiveINSPECTION FOUND SEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT 14ABC INOPERATIVE DUE TO A DEFECTIVE SPLICE. THE WIRING WAS REPAIRED IAW WIRING MANUAL 20-10-13. FUNCTIONAL CHECKS WERE GOOD IAW MM 33-51-00.SDR AALA20021602Wire · brokenLAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHT IN TAIL SECTION FOR TAIL CONE RELEASE HANDLE STATION 1516 INOPERATIVE. REPAIRED BROKEN WIRE ON TAIL COMPARTMENT OVERHEAD EMERGENCY LIGHT AT STATION A482. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AWXA200201106Connector · damagedDURING B-02 CHECK THE SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT WAS FOUND INOPERATIVE AT SEAT ROW 20 LT. MAINTENANCE REMOVED AND REPLACED A BAD PIN ON CONNECTOR 7260VC9 AT SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT SEAT ROW 20 LT IAW ESPM 20-48-24, PG. 13. OPERATSDR 2003F00203Connector · looseOVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE TROUBLESHOT AND FOUND CONNECTOR LOOSE. RESECURED. OPS CHECK GOOD. (M)SDR 2003F00205Connector · looseOVERHEAD EMERGENCY EXIT LIGHT ABOVE FAS JUMPSEAT INOPERATIVE. MAINTENANCE TROUBLESHOT AND FOUND CONNECTOR LOOSE. RESECURED. OPS CHECK GOOD. (M)SDR 2003F00204Connector · looseEMERGENCY EXIT IGHT BELOW COCKPIT DOOR INOPERATIVE. MAINTENANCE TROUBLESHOT AND FOUND CONNECTOR LOOSE. RESECURED, OPS CHECK GOOD. (M)SDR ASAA0280516Wire · brokenPDX - DURING PREFLIGHT CHECK, ONE EMERGENCY TRACK LIGHT AT THE OVERWING EMERGENCY EXIT WAS FOUND TO BE INOPERATIVE. REPAIRED BROKEN WIRE. LIGHTS THEN OPERATED PROPERLY. (M)SDR 0203616313Wire · disconnectedDURING LINE CHECK FOUND ZONE D LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REINSTALLED WIRE, OPERATIONAL CHECK GOOD.SDR 0203606303Wire · disconnectedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 52ABC-61ABC. RESECURED WIRE CONNECTOR. OPERATIONAL CHECK GOOD.SDR GTIA021164Wire · disconnectedDTW - FOUND EMERGENCY LIGHTS ABOVE TAIL COMPARTMENT WALKWAY INOPERATIVE. RECONNECTED WIRES TO LIGHT. OPS CHECKS GOOD IAW 33-53-02. (M)SDR RAIA00211301Connector · looseEMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AFT CABIN. RE-SECURED CONNECTOR AT EMERGENCY ESCAPE PATH LIGHTING STRIP, OPS CK OK.SDR UPS02439846Wire · brokenINSPECTION TYPE:PFLT FOUND F/O EMERGENCY LIGHT INOP ON GLARESHIELD. R/R BULB NO HELP. FOUND WIRE W2032-WHT/BLU BROKEN. REPAIRED IAW WDM 33-13-11. OPS CHECK OKAY.SDR AALA20021564Wire · faultyDURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT ON SIDEWALL IN AFT STAIRWAY, INOPERATIVE. REPLACED WIRE AT EMERGENCY EXIT LIGHT ON SIDEWALL IN AFT STAIRWAY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20021552Wire · brokenEMERGENCY LIGHT OVERHEAD AFT OF VAULT DOOR INOPERATIVE. REPAIRED BROKEN WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR PCAA0210130Wire · shortedDURING ROUTINE MAINTENANCE VISIT SEVERAL EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. ALL LIGHTS FOR POWER SUPPLY 3351-P2 WERE FOUND INOPERATIVE. AFTER TROUBLESHOOTING IT WAS DISCOVERED THAT THE LIGHT ASSEMBLY FOR LAV OCCUPIED & FORWARD EMERGENCY EXIT SIGNSSDR ASAA0280445Wire · shortedOAK - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE BEYOND ROW 26. REPAIRED AND REPOSITIONED CONNECTOR WIRE WHICH WAS SHORTING ON A PNEUMATIC DUCT. (M)SDR AALA20021540Wire · damagedLAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 26 A/B INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT WIRE AT SEAT 26 A/B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR USAASA02092Wire · out of positionPHL - FOUND THE LEFT, ROW 1, SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE, WITH A WIRE PULLED FROM THE CONNECTOR. (M)SDR RAIA00211296Connector · looseEMERGENCY ESCAPE PATH LIGHTS INOPERATIVE. RE-SECURED EMERGENCY PATH LIGHT STRIP CONNECTOR, OPS CK OKSDR CX2A02CL212Wire · brokenDURING ROUTINE MAINTENANCE THE NR 3 EMERGENCY FLOOR LIGHT STRIP WAS INOPERATIVE. MAINTENANCE INSPECTED AND FOUND THE LIGHT STRIP HAD BROKEN WIRES. THE LIGHT STRIP WAS REPLACED.OPERATIONAL CHECKS WERE GOOD.SDR DL73K021229Wire · brokenRED TRACK LIGHTING INOP AT FWD COAT CLOSET, REPAIRED WIRE.SDR PCAA0210126Wire · looseDURING ROUTINE MAINTENANCE VISIT 5 LAMPS FOR EMERGENCY PATH FLOOR LIGHTS FOUND INOPERATIVE. WIRING WAS RESECURED. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR PCAA0210124Wire · brokenDURING ROUTINE MAINTENANCE VISIT 2 FORWARD EMERGENCY FLOOR PATH LIGHTS FOUND INOPERATIVE. BROKEN WIRE WAS REPAIRED BETWEEN 2ND AND 3RD FLOOR LIGHT ASSEMBLIES ON FLOOR TRACK. AIRCRAFT RETURNED TO SERVICE.SDR GTIA021168Wire · brokenFTW - FOUND EMERGENCY OVERHEAD LIGHTS INOPERATIVE. L1 DOOR EMERGENCY CARRY AROUND LIGHT STAYS ON WHEN NOT ARMED AFTER ARMING AND DISARMING. FOUND LOOSE TERMINAL WIRING ON EMERGENCY LIGHTING BATTERY CHARGER, REPAIRED WIRING. FOUND BROKEN WIRES ON CONNECTOR ASDR DL767021220Wire Harness · damagedEMERGENCY PATH LIGHT AT SEAT 31AB INOP. REPLACED UNDERSEAT HARNESS. LIGHT OPERATES NORMALLY.SDR 0203505525Wire · brokenFIRST CLASS EMERGENCY FLOOR LIGHTS WILL NOT ILLUMINATE. FOUND BROKEN WIRE IN TRACK LIGHTING AT ROW NR 1. REPAIRED WIRE. OPERATIONAL CHECK GOOD.SDR ASAA0280423Connector · disconnectedDURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE AT ROWS 1-3. REATTACHED CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)SDR AALA20021475Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE, LEFT CEILING EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIR LEFT CEILING EMERGENCY EXIT LIGHTS WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR SWAA022440Wire · damagedDURING SCHEDULED SERVICE CHECK, FOUND EEPLS INOP AND DAMAGED AT OVERWING EXIT. REMOVED AND REPLACED BATTERY AND RESPLICED WIRES PER MM.
Back to JASC 3397