SDR UIEA2026081400760Wire · damagedCENTER SECTION ROW 26 AND AFT DID NOT DEPLOY O2 MASKS, REPAIRED WIRE W0720-01-14 BTWN PANEL P19 AND CONNECTOR D6000. OPS CHECKED GOOD IAW SWPM 20-10-11, WDM 35-21-14, AND AMM 35-21-00.SDR ABXA20260807351Elec Connector · defectiveON PREDEPARTURE CHECK EICAS OXYGEN PRESS READS 40 PSI BOTTLE 1. ACTUAL READINGS BOTTLE #1 1850 PSI BOTTLE #2 1450 PSI. DEFERRED CREW BOTTLE #1 EICAS INDICATION IAW ABX MEL 35-11-2-1 VERIFIED O2 BOTTLES OPEN MX ACTIONS C/W, PLACARD INSTALLED. VERIFY PRESSURE ABSDR AALA202606299168Elec Connector · disconnectedAIRCRAFT IN BASE MAINTENANCE: FORWARD LEFT ATTENDANT OXYGEN MASK DID NOT DEPLOY. CONNECTED ELECTRICAL CONNECTOR ON FORWARD ENTRY HEADER PANEL PER AMM 25-21-34.