What it covers
For reports indicating a problem with wiring specific to the Vacuum System.
Service difficulty reports · 4
Reports filed under 3797, newest first.
| 2012 | 1 |
|---|---|
| 2013 | 2 |
| 2019 | 1 |
SDR 2019FA0000374Wire Harness · incorrectDURING INSPECTION, FOUND VACUUM GENERATOR POWER SUPPLY CABLES LABELLED WITH MASKING TAPE.
AFTER GIVING IT A CLOSER LOOK, FOUND ALL CLAMPS NOT TIGHTENED, SEVERAL CLAMPS MISSING AND SOUND PROOFING NOT CORRECTLY INSTALLED.
THE COMPLETE WIRE HARNESS WAS INCORRESDR CALA2013082890809Socket · failedON APPROACH VACUUM OUTLET AT DOOR L2 STARTED SMOKING & ARCING. REPLACED SOCKET OUTLET & SPLICED NEW WIRE TERMINALS IAW SWP 20-30-11. SYSTEM CHECKED OK. NO FURTHER EVIDENCE OF WIRE DAMAGESDR CALA2013073090088Connector · melted3L VAC OUTLET BURNED DURING VACUUM OPERATION. BACK OF CONNECTOR FOUND MELTED, CIRCUIT BREAKER PULLED AND COLORED WIRES INSULATED AND SECURED.SDR UALA2012081604551Wire · chafedAFT VACUUM BLOWER (LAV SYS 1) CIRCUIT BREAKER POPPED. TROUBLESHOT AS PER WD 38-32-11. FOUND NO POWER AT PINS 2 AND 3 ON D1266, HAVE 115V AC AT PINS 22 2 0 24 ON D6314 NEED TO CHECK FROM D1266 BACK. NO FURTHER TIME DUE TO AC MOVEMENT BLOWER SYSTEM DEACTIVATE