What was found
AFT VACUUM BLOWER (LAV SYS 1) CIRCUIT BREAKER POPPED. TROUBLESHOT AS PER WD 38-32-11. FOUND NO POWER AT PINS 2 AND 3 ON D1266, HAVE 115V AC AT PINS 22 2 0 24 ON D6314 NEED TO CHECK FROM D1266 BACK. NO FURTHER TIME DUE TO AC MOVEMENT BLOWER SYSTEM DEACTIVATED AS PER MEL CP PULLED. FOUND CHAFED WIRES W1354 -017-12 AND W1354-001-16 REF WDM 38-32-11 AND 21-26-11. REPAIRED WIRES WITH A SEALED SPLICE AT STA. 1550 FWD OF CABIN PRESSURE OUTFLOW VALVE (V15) PER SWPM 20-10-13 AND 20-30-12. OPS CHECK GOOD.