JASC 3810

Service difficulty reports · 418

Reports filed under 3810 · Potable Water System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3810'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA202610129314Valve · inoperativeAIRCRAFT WAS NOT GROUNDED: -- NO EMERGENCY DECLARED AND AIRCRAFT WAS NOT OVERWEIGHT FOR LANDING -- NO RUNNING WATER ON ALL 3 LAVATORIES SINKS AND RINSING WATER ON TOILETS. FILL/OVERFLOW VALVE FOUND PARTIALLY OPEN, VALVE FULLY CLOSED AND WATER TANK FULL, OPS COct 8, 2026 · N998NN · Boeing 737823SDR R61A2026100100291Anti-Ice System · faultedANTI-ICE WING FAIL IN FLIGHT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. PERFORMED A-I WING FAIL RESET, FAULT CLEARED.Sep 28, 2026 · N861RW · Emb ERJ170100SESDR SWAA2026092854306Filter · odorFWD GALLEY WATER SMELLS MUSTY. REMOVED AND REPLACED FWD GALLEY WATER FILTER PER AMM 38-10-01. NO FOUL ODORSep 23, 2026 · N9015R · Boeing 7378SDR CALA2026092119556Potable Water · contaminatedWATER FROM REAR COFFEE MACHINE SMELLS AND TASTES BAD. DRAINED AND REFILLED POTABLE WATER SYSTEM IN REF TO AMM 12-14-00. OPS CHECK BOTH REAR COFFEE MAKERS IN THE REAR OF THE AIRCRAFT IN REF TO AMM 25-32-01. THE WATER NO LONGER SMELLS.Sep 19, 2026 · N17574 · Boeing 7379SDR CALA2026092119555Potable Water · contaminatedBAD ODOR AND TASTE COMING FROM POTABLE WATER. DRAINED POTABLE WATER TANK AND REFILLED TANK, ALSO PURGED ALL FACETS AND COFFEE MAKERS, ODOR AND SMELL IS GONE. REF FIM 38-10 TASK 803.Sep 18, 2026 · N37555 · Boeing 7379SDR CALA2026080518333Potable Water · low pressureFA REPORTED NO WATER PRESSURE WHEN REACHED CRUISE, ARRIVED, CHECKED PORTABLE WATER PANEL LATCHES WERE CLOSED, VERIFIED THE FILL VALVE AND THE DRAIN VALVE WERE IN THE CLOSED POSITION (NORMAL POSITION), WATER TANK WAS FULL ON ARRIVAL. HAD PORTABLE WATER SERVICEAug 4, 2026 · N37313 · Boeing 7378SDR CALA2026072017897Water Line · leakingAFT RT LAV LEAKING AND SMELLS BAD INBOUND CREW REPORTS EVIDENCE OF WATER LEAK AROUND PAPER TOWEL HOLDER UNDER AFT RT LAV SINK. INSPECTED CABINET UNDER SINK FOUND NO STANDING WATER AND NO ACTIVE LEAK.Jul 17, 2026 · N47517 · Boeing 7379SDR DALA2026071504165Water Heater · odorDIVERTED TO YVR DUE TO ELECTRICAL ODOR IN THE AFT LAVATORIES. PLACED AFT LEFT LAVATORY WATER HEATER ON MEL; SAME REPLACED. (LP# 8740810, 8740812, 8740813; AIRCRAFT WAS GROUNDED)Jul 12, 2026 · N311DU · Airbus BD5001A11SDR 2026FA0000559Potable Water · inoperativeNO PORTABLE WATER DURING FLIGHT. IAW TSM 38-12-00-810-814-A REV.77 PERFORMED OPERATIONAL TEST OF PORTABLE WATER DRAIN SYSTEM AS PER AMM 38-14-00-710-001-A REV.77 DATE 01-MAY 2026 AND ALL OKJun 30, 2026 · N965AV · Airbus A320251NSDR AALA202606150439Potable Water · emptyAIRCRAFT WAS GROUNDED: FA NOTIFIED FLIGHT DECK THEY HAD ZERO POTABLE WATER UPON REACHING CRUISE. I HAD THEM TRY TO FLUSH TOILETS AND USE SINK, STILL ZERO WATER AVAILABLE. ALSO ZERO WATER AVAILABLE IN EITHER GALLEY. DECESION MADE TO RETURN TO CLT EMERGENCY DECLJun 13, 2026 · N990NN · Boeing 737823SDR CALA2026052816604Pressure System · inoperativeNO WATER PRESSURE FOR ENTIRE AIRCRAFT AFTER TAKEOFF.May 24, 2026 · N785UA · Boeing 777222SDR CALA2026051516279Potable Water · not openedNO WATER PAX IN ANY LAV OR FAUCET FOUND HANDLE AT THE WATER SERVICING PANEL, NOT IN THE FULLY CLOSED DETENT POSITION PLEASE HANDLE IN THE FULLY CLOSED DETENT POSITION TECH FOUND WATER SERVICING VALVE IN WRONG POSITION UPDATE FOR SDR PURPOSES BECAUSE AIRCRAFT WMay 14, 2026 · N47345 · Boeing 7378SDR DALA2026050802921Water Heater · failedLAVS AT 3 INBD ELECTRICAL ODOR. REPLACED HOT WATER HEATER PER A330 AMM 38-14. OK FOR SERVICE. (1583286) AIRCRAFT WAS GROUNDED.May 8, 2026 · N822NW · Airbus A330302SDR SCNA20260506187Potable Water · contaminatedWATER HAS A TOXIC ODOR, COFFEE/ HOT WATER SMELLS LIKE CHLORINE AND HAS A CHECMICAL TASTE AND MAKES EYES BURN. SERVICED POTABLE WATER SYSTEM IAW AMM 38-42-00-800-802. NO ODOR FOUND. FLUSHED POTABLE WATER SYSTEM AND RESERVICED PER AMM 38-10-00-860-005.May 3, 2026 · N828SY · Boeing 7378F2SDR SCNA20260504178Potable Water · contaminatedWATER HAS A TOXIC SMELL. COFFEE/ HOT WATER SMELLS LIKE CHLORINE AND HAS A CHECMICAL TASTE AND MAKES EYES BURN. SERVICED POTABLE WATER SYSTEMPER AMM 38-42-00-800-802.NO SMELLED FOUND. FLUSHED POTABLE WATER SYSTEM AND RESERVICED PER AMM 38-10-00-860-005.May 3, 2026 · N828SY · Boeing 7378F2SDR CALA2026050515979Potable Water · no discrepancyPOTABLE WATER HAS A CHEMICAL TASTE. WHEN JUST WATER IS POURED IT HAS A CHLORINE LIKE ODOR. OPERATIONS DRAINED AND SERVICED POTABLE WATER SYSTEM. PERFORMED INITIAL EVALUATION PER FIM 38-10 TASK 810. NO BAD SMELL OR WATER QUALITY ISSUE.May 1, 2026 · N69818 · Boeing 737924ERSDR DALA2026050402792Water Heater · failedDIV - TO OMA DUE TO ELECTRICAL SMELL IN THE AFT GALLEY. SUSPECTED AFT LAV WATER HEATER INOPERATIVE, PLACED ON MEL. LATER MEL CLEARED WITH AN OPS CHECK. (LP 8369650 - AIRCRAFT WAS GROUNDED)May 1, 2026 · N531DA · Airbus A321271NXSDR AALA202604289909Water Heater · failedAIRCRAFT WAS GROUNDED: LAVATORY-D SMOKE LIGHT ILLUMINATED ON OVERHEAD PANEL. FLIGHT ATTENDANT CONFIRMED SMOKE PRESENCE IN LAVATORY-D THAT QUICKLY DISSIPATED UPON OPENING THE DOOR. ELECTRICAL ODOR REMAINED, BUT NO FURTHER EVIDENCE OF SMOKE OR FIRE. REMOVE AND RApr 27, 2026 · N924NN · Boeing 737823SDR CALA2026042415684Valve · closedNO WATER FLOW ON AIRCRAFT SPIGOTS AND LAV OVERFLOW VALVE CONFIRMED TO BE IN CLOSED POSITION. CABLE DISCONNETED AND SECURED. ALL FOUCETS WITH WATER AND SYSTEM PRESSURIZED PROPERLY. NO LEAKS WERE FOUND IAW AMM 38-11-03Apr 21, 2026 · N785UA · Boeing 777222SDR CALA2026042315656Drain Mast · missingUPON ARRIVING TO THE GATE RAMP REPORTED THERE WAS METAL HANGING FROM THE A/C WHEN MYSELF AND TECHS WENT OUT WE REALIZED IT WAS THE FWD DRAIN MAST THAT WAS MISSING. ADDED PHOTOS REF L/P 8622727 FOR MX ACTION MAST, DRAIN, WA OFF 29-3831-9-9001 3818 ON 0000 RAMApr 20, 2026 · N79402 · Boeing 737924SDR SWAA2026040786115Water Heater · failedFA REPORTED ELECTRICAL BURNING SMELL COMING FROM AFT RIGHT LAV<[01] PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION REF AMM 05-51-56. FOUND RH AFT LAV WATER HEATER TO BE THE SOURCE OF THE SMELL. SEE NEXT PAGE FOR MEL LP # 3054862.Apr 2, 2026 · N8650F · Boeing 7378H4SDR SWAA2026031679516Filter · odorWATER SMELLS OF CHEMICALS. DRAIN POTABLE WATER TANK. R & R GALLEY FILTERS. SERVICED POTABLE WATER PER AMM 38-11-99.Mar 13, 2026 · N8670A · Boeing 7378H4SDR CALA2026031314542Water Heater · overheatedPER FA SMOKE ALARM LAV E WENT OFF DURING TAXI IN AND WATER HEATER VERY HOT W AMBER LIGHT ON PER INBD CAPT SALATICH NO SMOKE OR ODOR NOTICED. UPON ARRIVAL IN CABIN SMOKE DETECTOR OFF. HOT WATER HEATER CKS NORMAL FOR TEMP. ACP'ED SMOKE DETECTOR TEST AND TEST NORMar 10, 2026 · N39416 · Boeing 737924ERSDR DALA2026030301467Water Heater · overheatedSHIP 3034 - FUMES - CREW REPORTED AN ELECTRICAL SMELL DURING THE APPROACH. DONNED OXYGEN MASKS AND DECLARED AN EMERGENCY. CORRECTIVE ACTION: F/C LAVATORY WATER HEATER APPEARS TO BE OVERHEATING. DEFERRED WATER HEATER PER MEL. REPLACED FORWARD LAV WATER HEATER PMar 1, 2026 · N334DN · Airbus A321213SDR SCNA20260216083Potable Water · odorFWD GALLEY COFFEE MAKER HAS STRONG CHEMICAL ODOR, POTABLE WATER SYSTEM. DISINFECTED POTABLE WATER SYSTEM OZON REF TASK CARD 0538000002 W/O 102224 THIS CLEARS MEL 38-1-B MDDR# 136908Feb 14, 2026 · N835SY · Boeing 7378KNSDR SCNA20260216082Potable Water · odorFA'S AND PASSENGERS NOTICE STRONG CHEMICAL SMELL COMING FRIM COFFEE/MAKER. POTABLE WATER SERVICED REF AMM 12-14-01 OK FOR SERVICEFeb 14, 2026 · N835SY · Boeing 7378KNSDR SWAA2026021168977Potable Water · odorF/A STATED A FOUL WATER ODOR FROM AFT GALLEY COFFEE POT. RAMP DRAINED AND REFILLED WATER TANK IAW SIP.Feb 8, 2026 · N910WN · Boeing 7377H4SDR CALA2026020513599Valve · inoperativeNO POTABLE WATER. LAV MOTOR WORKING WITH NO WATER. WATER GAUGE SHOWS FULL. RTB EWR IF AIR IS COMING OUT FROM AFT OVERFLOW DRAIN PORT AT STA 1530, REPLACE VENT OVERFLOW VALVE V130 REF AMM 38-11-05-004-001 EWRMM WORKING ITEM REF LOGPAGE 7804209. INSPECTED PRESFeb 2, 2026 · N66051 · Boeing 767424ERSDR CALA2026020513591Potable Water · leakingALL FWD DRAIN HOLES ON BOTTOM OF ACFT DRAINING WATER. WATER LINE IS INSTALLED & LEAK CHECKED. DRAIN VALVE INSTALLATION STILL NEEDS TO BE COMPLETED FROM STEP 4 A12. COMPLETED STEPS UP TO D. (1) ON DRAIN VALVE INSTALLATION IAW AMM 38-14-45-400-001-A. GALLEY LEFeb 2, 2026 · N4901U · Airbus A320232SDR CALA2026020413546O-Ring · damagedFOUND WATER DRIPPING FROM BELLY DRAIN FWD OF FWD CARGO DOOR CONTROLS. WATER POOLING BELOW 80VU RACK. TRACED WATER BACK FROM BELOW 80VU RACK TO A WIGGINS FITTING FWD OF ACCLRM 12CE1 AND 12CE3. DISSASEMBLED FITTING REF AMM 20-23-38-000-001-A, FOUND FITTING COVERFeb 2, 2026 · N34551 · Airbus A321271NXSDR CALA2026020313534Potable Water · leakingFOUND AFT GALLEY FLOODED WITH WATER. REMOVED ALL GALLEY CARTS FROM AFT GALLEY & COULD NOT FIND SOURCE OF LEAK. ATTEMPTED TO SERVICE POTABLE WATER, BUT ACFT WOULD NOT RECEIVE & HOLD WATER. WATER SAME OUT OF EVERY DRAIN ORFICE ON BELLEY OF ACFT. OPENED AFT CFeb 1, 2026 · N4901U · Airbus A320232SDR CALA2026013013448Water Line · burstPOTABLE WATER LINE BURST IN THE AFT CARGO BAY, AFT BULKHEAD. LINE CONNECTS TO POTABLE WATER TANK. FLOOR PANELS REMOVED IAW AMM 25-52-10-000-801, OZONE WATER CART LIQUID SPILL DETERMINED TO BE NON-HAZARDOUS IAW EC/RA 2011-01000, AFFECTED SPILL AREA BS 727+4 - Jan 29, 2026 · N37263 · Boeing 737824SDR CALA2026012613250Potable Water · odorFA SAYS POTABLE WATER HAS STRONG FISH ODOR. PERFORMED A COMPLETE DRAIN & REFILL AS REQUIRED.Jan 26, 2026 · N487UA · Airbus A320232SDR CALA2026012313187Filter · faultedIN FLIGHT FA REPORTED NO H2O PRESS IN LAVS AND GA LLEYS. REPEAT GRIPE. VERIFIED WATER ON AND WORKING NORMALLY ON GROUND AFTER BLEEDING SOME AIR. CREW REPORTS THAT THERE IS NO WATER IN FLIGHT. SUSPECT PRESSURE REGULATOR ON PNEUMATIC PRESSURIZATION SIDE. REPLACEJan 20, 2026 · N17337 · Boeing 7378SDR DALA2026010400042Toilet · odorCOCKPIT SMELL LIKE URINE/LAVATORY WASTE. REMOVED, INSPECTED, REINSTALLED FIRST CLASS LAV SHROUD IAW AMM 38-32. NO DEFECTS NOTED. REMOVED FIRST CLASS LAV SHROUD FOR ACCESS PER AMM 38-32. REMOVED AND REPLACED FIRST CLASS TOILET ASSY. PER AMM 38-31. LEAKS AND OPJan 3, 2026 · N329NB · Airbus A319114SDR SWAA2026010557656Filter · odorPOTABLE WATER HAS BLEACH ODOR. DRAINED AND RESERVICED POTABLE WATER. REPLACED WATER FILTERS IN FORWARD AND AFT GALLEYS PER AMM 25-31-00.Jan 2, 2026 · N8882Q · Boeing 7378SDR DALA2025122909475Line · leakingPRES/DE-THE CREW WAS UNABLE TO CONTROL PRESSURIZATION, PERFORMED AN EMERGENCY DESCENT. MAINTENANCE FOUND A WATER LEAK DIRECTLY ABOVE THE OUTFLOW VALVE RENDERING THE VALVE INOPERATIVE, REPLACED A POTABLE WATER LINE AND O-RING. WATER SYSTEM AND AUTO PRESSURIZADec 28, 2025 · N398DA · Boeing 737832SDR CALA2025121012008Linkage · faultedNO WATER AVAILABLE, NO PRESSURE FOR TOILET. WASTE TANK 3 FULL. ON GROUND NO WATER AVAILABLE IN ACFT. WATER SERVICE CART CONFIRMED WATER TANKS FULL. ALL HANDLES CLOSED-NORMAL POSITION, CYCLED DURING SERVICE. STILL NO WATER, CONFIRMED WATER COMPRESSOR RUNNING Dec 6, 2025 · N791UA · Boeing 777222SDR SWAA2025120240455Filter · odorSTAR AMMONIA ODOR IN THE POTABLE WATER SYSTEM. DRAINED POTABLE WATER TANK AND REPLACED AFT & FWD FILTERS PER AMM 38-10-00.Nov 28, 2025 · N8686A · Boeing 7378H4SDR DALA2025110408061Water Heater · odorFA`S NOTICED BURNING SMELL IN 3L LAV. REPLACED HOT WATER HEATER. NO DIVERSION. OK FOR SERVICE. (7938112)Nov 2, 2025 · N858NW · Airbus A330223SDR CALA2025102210403Potable Water · contaminatedWATER HAS STRONG CHEMICAL SMELL AND TASTE REF FIM 38-10 TASK 810 DUMPED AND FLUSHED POTABLE WATER. SMELL IS NO LONGER. ACFT OK FOR SERVICEOct 22, 2025 · N72405 · Boeing 737924SDR CALA2025102010276Potable Water · contaminatedWATER IN AFT GALLEY HAS METALLIC TASTE STRONG ENUOGH TO MAKE WAT ER UNSUITABLE TO BREW CFFEE POTABLE WATER DRAINED AND SERVICED MUTIPLE TIMES PER AMM 12-14-00-600-801& 802 WATER WAS RUN THROUGH GALLEY AND LAVS WATER NORMAL CLEAR IN COLOR WITH NO SMELLSOct 20, 2025 · N37342 · Boeing 7378SDR CALA2025102010268Potable Water · contaminatedDRAIN AND REFILL THE POTABLE WATER SYSTEMS WITH FRESH WATER PER THE GMM COFFEE HAS CHEMICAL TAST E AND SMELL. REMADE COFF EE SAME RESULT . SUSPECT WATER TANK NEEDS FLUSH DRAIN AND REFILLED POTABLE WATER SYSTEM,Oct 20, 2025 · N68801 · Boeing 737924ERSDR CALA2025102010266Potable Water · contaminatedWATER TAST REPORTED TO BE VERY CHLORINE UNUSABLE FOR COFFEE DRAIN PORTABLE WATER AND FULLY SERVICE PORTABLE. NO BAD SMELL. REFERENCED FIM REFERENCE: 38-10 TASK 803Oct 20, 2025 · N17401 · Boeing 7379SDR CALA2025102010263Potable Water · contaminatedWATER TASTES BAD, FORWARD GALLEY AND LAV COMPLEX DRAINED WATER TANK, RINSED WATER TANK AND OPS CHECKS ALL FWD WATER GALLEY AND LAV COMPONENTS PER AMM FIM TASK 38-10-00-810-803. WATER DOES NOT SMELL BAD AND THE WATER QUALITY IS GOOD.Oct 20, 2025 · N17301 · Boeing 7378SDR SWAA2025101424089Water Heater · smokeAFT LAV CAPTAIN SIDE HAS ELECTRICAL SMELL AND VISIBLE SMOKE<[01] PERFORMED CONDITIONAL INSPECTION IAW AMM 05-51-56 AND IFIM 21-00-00-810-830 AND FOUND AFT LH LAV WATER HEATER SIGN/ EVIDENCE OF ELECTRICAL SMEELL. R&R AFT LT LAV WATER HEATER IAW AMM 38-13-01. Oct 13, 2025 · N8910Q · Boeing 7378SDR CALA2025100209520Potable Water · odorSTRONG ODOR IN POTABLE WATER AND LAV WATER, PERFORMED POTABLE WATER SYSTEM DISINFECTION IAW JC B757-MP-6700-38-001-00Oct 2, 2025 · N21108 · Boeing 757224SDR CALA2025092209073Potable Water · contaminatedMULTIPLE PAX AND FAS STATE THAT HOT WATER, SMELLS AND TASTES LIKE CHE MICALS, CA SMELLED TO CONFIRM. DRAINED PORTABLE WATER TWICE. RESERVICED AND RAN WATER THRU ALL COFFEEMAKERS AND RAN ALL LAVS SINK WATER. NO SMELL. AC OK FOR SERVICESep 21, 2025 · N66848 · Boeing 737924ERSDR SWAA2025092216592Filter · odorFORWARD GALLEY COFFEE MAKER WATER HAS DISCOLORATION AND FOUL ODOR. OK TO CONTINUE PER MEL 38-10-01A, POTABLE WATER SYSTEM - INDIVIDUAL COMPONENTS DEACTIVATED & ISOLATED. WITH SP1B AND AUTHORIZATION NUMBER 280771. REPLACED FWD GALLEY WATER FILTER PER AMM 25Sep 19, 2025 · N8769Q · Boeing 7378SDR CALA2025090208341Potable Water · odorSTRONG CLEANER SMELL AND TASTE IN POTABLE WATER WATER SVC VENDOR NOTIFIED TO SERVICE WATER.Aug 30, 2025 · N77598 · Boeing 7379
Back to JASC 3810