JASC 3810

Service difficulty reports · 418

Reports filed under 3810 · Potable Water System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3810'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA2025081906205Potable Water · damagedATB, RETURN TO HNL DUE TO NO POTABLE WATER AVAILABLE. POTABLE WATER SYSTEM VERIFIED EMPTY UPON ARRIVAL. SERVICED POTABLE WATER. CONDUCTED EXTENDED TIME PRESSURIZED LEAK CHECKS. NO LEAKS NOTED. A/C RTS.(7354744)Aug 19, 2025 · N194DN · Boeing 767332SDR CALA2025073107118Potable Water · contaminatedPOTABLE WATER SMELLS AND TASTES LIKE CHEMICAL WATER TANK NEEDS TO BE FLUSHED. PERFORMED FIM 38-10 TASK 801-C1. FLUSHED WATER SYSTEM NO DEFECTS NOTED AT THIS TIME.Jul 29, 2025 · N57868 · Boeing 75733NSDR AALA202507316991Potable Water · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT THAT POTABLE WATER SMELLS FUNKY. CONFIRMED POTABLE WATER SMELLS. FOLLOWED J/C 08T10038001, ACCOMPLISHED DISINFECTION WITH OZONE TRALER BLUE. PER J/C 08T10038006, NO SMELL NOTED AT THIS TIME.Jul 19, 2025 · N885NN · Boeing 737823SDR AALA202507216991Lavatory · abnormalAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT THAT POTABLE WATER SMELLS FUNKY. CONFIRMED POTABLE WATER SMELLS. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).Jul 19, 2025 · N885NN · Boeing 737823SDR AALA202507184661B-Nut · leakingAIRCRAFT WAS GROUNDED: STRONG SMELL AND LEAKAGE FROM FORWARD LAVATORY ON TAKEOFF AND LANDING AS REPORTED BY FLIGHT ATTENDANT. TROUBLESHOOT PER FIM 38-1000-810-807, UPON OPENING SINK CAB DOOR FOUND WATER DRIPPING FROM B-NUT ON WATER HEATER. TIGHTENED B-NUT, PERJul 17, 2025 · N981AN · Boeing 737823SDR CALA2025070906407Potable Water · odorFA REPORTS POTABLE WATER SMELLS LIKE CHEMICALS. POTABLE WATER SYS DRAINED AND FILLED WITH FRESH WATER, WATER FLUSHED THROUGH ALL GALLEY COFFEE MKRS AND TAPS, SYS SERVICED SATIS IAW AMM 38-11-00 REV 136Jul 9, 2025 · N17133 · Boeing 757200SDR CALA2025063006033Faucet · leakingWATER CONTINUOUSLY LEAKING FROM FORWARD GALLEY WITH VERY STRONG ODOR. FORWARD GALLEY WATER FAUCET ADJUSTED AND WATER LEAK STOP AND DRAIN WATER FROM SYSTEM DRAIN TWICE AND REFILLED FOT ODOR MM 12-15-38-613-001-AJun 27, 2025 · N467UA · Airbus A320232SDR CALA2025061305528Potable Water · odorPLANE POTABLE WATER FROM ALL GALLEYS TASTE/SMELL STRONG CLORINATION AND DETERGENT. PAX COMPLAINT FLUSHED POTABLE WATER SEVERAL TIMES PER AMM 38-10-00-170-003, OK TO CONTINUE.Jun 11, 2025 · N41140 · Boeing 757224SDR AALA202506028362Water Heater · shortedAIRCRAFT WAS GROUNDED: BURNING SMELL IN FORWARD LAVATORY, VISIBLE SMOKE AND ELECTRICAL SMELL CONFIRMED ON FORWARD LAVATORY. REMOVED AND REPLACED LAVATORY-A WATER HEATER. PER AMM 38-13-01.Jun 1, 2025 · N857NN · Boeing 737823SDR CALA2025052604937Potable Water · abnormalFA REPORTS CHEMICAL SMELL IN WATER PAX COMPLAINTS ABOUT CHEMICAL TASTE OF COF WATER SYS MUST HAVE OZONE PERFORMED BEFORE FURTHER FLIGHT UNLOCKING FOR SIGN OFF ACCOMPLISHED WATER SYS OZONE PER AMM 38-10-00May 22, 2025 · N14536 · Airbus A321271NXSDR CALA2025051404660Potable Water · contaminatedWATER HAS BAD SMELL AND TASTE. MANY PAX RETURNED COFFEE DUE TO BAD TASTE. FOUND WATER TO SMELL STRONGLY OF CHLORINE. DRAINED AND FLUSHED POTABLE WATER SYSTEM. WATER NORMAL NOW. NO SMELL. REF: FIM 30-10 TASK 803. ADD EMP: U380359May 13, 2025 · N37536 · Boeing 7379SDR AALA202505127049Circuit Breaker · trippedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: POTABLE WATER FRONT AND REAR INOPERATIVE. AIRCRAFT DIVERTED TO AND LANDED SAFELY AT CLT. FOUND CB D11, P6-4 PANEL. NO HISTORY FOUND, PER GPM 13-04-7. CLOSED CIRCUIT BREAKER AND OPERTIONAL CHECK GOOD.May 10, 2025 · N963AN · Boeing 737823SDR CALA2025041703932Potable Water · odiferousWATER SUPPLY IN LAVATORY POOR QUALITY AFT RH LAV E DRAINED AND SERVICEDTHE PORTABLE WATER SYSTEM A COUPLE OF TIMES AND RAN THE WATER FAUCETS AT ALL LAVATORIES. NO BAD SMELLS OR SINGS OF WATER CONTAMINATION WERE FOUND. REF AMM 38-10 TASK 810Apr 15, 2025 · N73259 · Boeing 737824SDR DALA2025041502939Water Heater · failedSHIP 3946 -ATB/DE- RETURNED TO CHS DUE TO ELECTRICAL SMELL IN THE AFT GALLEY/LAVATORY. CORRECTIVE ACTION: REPLACED WATER HEATER PER B737 AMM 38-13.Apr 14, 2025 · N946DZ · Boeing 7379GPERSDR AALA202503214835Faucet · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: WATER IN AFT RIGHT LAVATORY FLOODED LAVATORY AND THE ENTIRE AFT GALLEY; AIRCRAFT AIR INTERRUPTED BACK TO AND LANDED SAFELY AT ORD. FOUND RIGHT AFT LAVATORY FAUCET PULLED FROM MOUNT. REMOVED AND REPLACED Mar 20, 2025 · N961AN · Boeing 737823SDR JJBA20250507029Line · corrodedLIGHT CORROSION ON BOTH CONNECTING ENDS OF PORTABLE WATER OVERFLOW LINE LOWER SECTION. REMOVED PORTABLE WATER OVERFLOW LINE LOWER SECTION. REPLACED PORTABLE WATER OVERFLOW LINE LOWER SECTION.Mar 8, 2025 · N12136 · Emb EMB145XRSDR AALA202502249867Potable Water · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORT FUEL AND OIL TYPE SMELL IN FORWARD CABIN AND GALLEY. ACCOMPLISHED SOF JC 08L00021001. AIRCRAFT WAS INSPECTED AND SOURCE OF ODOR IS DUE TO POTABLE WATER SOURCE NEEDING TREATMENT. NO FURTHER FINDINGS.Feb 22, 2025 · N885NN · Boeing 737823SDR AALA202412318188Faucet · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO ORD DUE TO THE FLIGHT CREW REPORTING THAT THE FIRST-CLASS LAVATORY SINK STARTED LEAKING 1 1/2 HOURS INTO FLIGHT. THE FLIGHT ATTENDANTS WERE UNABLE TO CONTROL LEAK WITH THE SHUT OFF VDec 29, 2024 · N926NN · Boeing 737823SDR AALA202412313972Selector Valve · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO ORD DUE TO THE FLIGHT CREW REPORTING THAT THE FIRST-CLASS LAVATORY SINK STARTED LEAKING 1 1/2 HOURS INTO FLIGHT. THE FLIGHT ATTENDANTS WERE UNABLE TO CONTROL LEAK WITH THE SHUT OFF VDec 29, 2024 · N926NN · Boeing 737823SDR AALA202412312098Hose · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO ORD DUE TO THE FLIGHT CREW REPORTING THAT THE FIRST-CLASS LAVATORY SINK STARTED LEAKING 1 1/2 HOURS INTO FLIGHT. THE FLIGHT ATTENDANTS WERE UNABLE TO CONTROL LEAK WITH THE SHUT OFF VDec 29, 2024 · N926NN · Boeing 737823SDR AALA202412308188Sink · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO ORD DUE TO THE FLIGHT CREW REPORTING THAT THE FIRST CLASS LAVATORY SINK STARTED LEAKING 1 1/2 HOURS INTO FLIGHT. THE FLIGHT ATTENDANTS WERE UNABLE TO CONTROL LEAK WITH THE SHUT OFF VDec 29, 2024 · N926NN · Boeing 737823SDR AALA202412160587Water Heater · burned outAIRCRAFT WAS NOT GROUNDED: PLASTIC BURNING SMELL COMING FROM LAV E DURING FLIGHT REPORTED BY FLIGHT ATTENDANT, CONFIRMED BY FIRST OFFICER ON THE GROUND. MAINTENANCE REPLACED WATER HEATER AT LAV E IAW AMM 38-12-16,Dec 15, 2024 · N909AM · Airbus A321231SDR AALA202412059631Valve · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: LAVATORYS AND GALLEYS HAD NO WATER; AIRCRAFT DIVERTED TO AND LAND LANDED SAFELY AT JFK. FOUND FILL-OVERFLOW VALVE LEAKING AIR PRESSURE. REMOVED AND REPLACED FILL OVERFLOW VALVE. PER AMM 38-11-04. ALL OPEDec 4, 2024 · N794AN · Boeing 777223SDR CALA2024112801337Tank · odorTHE WATER HAS A VERY STRONG CHEMICAL ODOR AND TASTE LOCAL VENDOR ABM DRAINED AND FLUSHED POTABLE WATER TANK. FLUSHED ALL GALLEY ACCESSORIES. WATER IS NOW CLEAN AND DELICIOUS.Nov 27, 2024 · N17564 · Boeing 7379SDR CALA2024111101092Potable Water · unknownPOTABLE WATER SYSTEM NEEDS FLUSHED. FORE AND AFT GALLEY HOT BEVE RAGES HAD CHEMICAL TASTE/SMELL VERIFIED WATER SVC FLUSHED AND FILLED POTABLE WATER SYSTEM. PURGED LINES AT GALLEYS.Nov 8, 2024 · N61886 · Boeing 737924ERSDR SWAA2024103153980Potable Water · contaminatedPOTABLE H2O HAS A STRONG CHEMICAL SMELL. GALLEY & LAV WATER SHUT OFF. POTABLE H2O HAS A STRONG CHEMICAL SMELL.<Oct 27, 2024 · N256WN · Boeing 7377H4SDR SIMA20240928001Drain Valve · failedMECH- AFT LAV HIGH VIBRATION AND HUMMING ON TAKE OFF. DECLARED EMERGENCY RETURN TO DFW. NOISE FOUND TO BE COMING FROM AUTO DRAIN VALVE. RAR AUTO DRAIN VALVE IAW AMM 38-31-04Sep 28, 2024 · N291NN · Emb ERJ170200LRSDR CALA2024082600498Relief Valve · missingSIGNIFICANT AMT OF WATER IN AFT CABIN AFTER TAKEOFF DURING TROUBLESHOOTING FOUND PRESSURE RELEIF VALVE OF WATER HEATER LAVATORY M BROKEN OFF. REMOVED WATER HEATER LAV M REF AMM TASK 38-13-51-004-001 AND STOWED IN LAVATORY M. R/R WATER HEATER IN LAV M IAW AMM 3Aug 23, 2024 · N17133 · Boeing 757224SDR AALA202408141398Faucet · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: WATER LEAKING IN AIRCRAFT CABIN; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT MIA. REMOVED AND REPLACED LAVATORY-D FAUCET. LEAK CHECK GOOD. PER AMM 38-11-05.Aug 13, 2024 · N306PB · Boeing 737823SDR DALA2024072607513Compressor · inoperativeSHIP 0190 -DIV- DIVERSION TO BOS DUE TO NO POTABLE WATER AVAILABLE AT SINKS OR GALLEY LOCATIONS. CORRECTIVE ACTION: C/W O/W LANDING INSPECTION. MEL APPLIED FOR POT WATER AIR COMPRESSOR. CAPPED AND STOWED POTABLE WATER COMPRESSOR OUTPUT. (6000810)Jul 25, 2024 · N190DN · Boeing 767332SDR CALA2024070901979Water System · pressure lossAIR RETURN DUE TO WATER SYSTEM NOT PRESSURIZING RESULTING IN NO WATER. PURGED AIR FROM ALL WATER SYSTEM SUPPLY SOURCES, COFFEEMAKES, GALLEY WATER SPIGOTS AND LAVATORY SINK SPIGOTS. WATER FLOWS FROM ALL SPIGOTS AND COFFEEMAKERS NORMALLY. COFFEE MAKERS WATER FJul 1, 2024 · N223UA · Boeing 777222SDR SWAA2024061701987Filter · contaminatedPOTABLE WATER HAS A PUNGENT STRONG CHEMICAL SMELL NOTICED BY FLIGHT CREW/CABIN CREW AND PASSENGERS. HOT BEVERAGE SERVICE WAS DIS-CONTINUED. BATHROOM FAUCET SUPPLY WAS ALSO TURNED OFF (CONTINUED BELOW) (CONTINUED- ) FRONT/ AND AFT AS WELL. HAND SANITIZER WAS MAJun 15, 2024 · N7849A · Boeing 73771BSDR AALA202406100287Water Heater · odorAIRCRAFT WAS NOT GROUNDED: BURNING PLASTIC SMELL FROM UNDER SINK IN FORWARD LAVATORY. TURNED OFF WATER HEATER BELOW SINK AND SMELL DISSIPATED. PERFORMED JOB CARD 26L00021001. FOUND SOURCE OF ODOR COMING FROM WATER HEATER IN FORWARD LAVATORY. REMOVED AND REPLACJun 9, 2024 · N184US · Airbus A321211SDR DALA2024050104844Lavatory · odorPERCEIVED ODOR PROTRUDING FROM THE INBOARD 3L LAVATORY. R/R TUCD IAW A350 AMM 25-41. OPS & BITE TEST OK. NO LEAKS NOTED. (LP# 5629240)Apr 28, 2024 · N569DZ · Airbus A350941SDR CALA2024041101041Heater · leakingWATER LEAKING UNDER FWD LAV SINK VANITY AT ARRIVAL, MM FOUND NO WATER PUTTLING IN THE LAVATORY, UNDER THE SINK OR IN THE GALLEY AREA OUTSIDE OF THE LAVATORY. MM COULD NOT DUPLICATE A LEAK BUT NOTED THAT THE BOTTOM OF THE WATER HEATER WAS WET. MM WILL BE CHANGIApr 8, 2024 · N27421 · Boeing 737924ERSDR AALA202307318824Tank · lowAIRCRAFT WAS NOT GROUNDED: AN EMERGECNY WAS DECLARED AND THE AIRCRAFT DIVERTED TO PHL DUE TO POTABLE WATER SHOWS EMPTY ON FLIGHT ATTENDANTS PANEL. THE AIRCRAFT LANDED SAFELY AT PHL WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AIRFRAME NO WATER LEAK DETECTEDJul 28, 2023 · N102NN · Airbus A321231SDR SWAA2023070374493Valve · leakingENROUTE; F/A'S REPORTED A STRONG UNIDENTIFIABLE ODOR THROUGHOUT THE ENTIRE CABIN. ODOR LASTED FOR ONLY A COUPLE OF MINUETES; AND WAS NOTICED BY PAX AND CREW. THERE WAS NO ODOR OR ABNORMAL INDICATIONS IN THE COCKPIT. FURTHER THERE WAS NO VISIBLE INDICATIONS OF Jun 29, 2023 · N7720F · Boeing 7377BDSDR SWAA2023041024424Heater · failedF/A REPORTED BURNING PLASTIC ODOR FROM F/O SIDE REAR LAV. SMOKE ALARM MOMENTARILY ACTIVATED. NO VISIBLE SMOKE OBSERVED.<[01] ACCOMPLISHED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION PER AMM 05-51-56; FOUND WATER HEATER FAILED. OK TO CONTINUE PER MEL 25-10-0Apr 7, 2023 · N8602F · Boeing 7378H4SDR AALA202304031388Nipple · crackedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO DFW, FLIGHT CREW REPORTED THAT THEY LOST ALL WATER (POTABLE) APPROXIMATELY 25 MINUTES INTO THE FLIGHT, RESULTING IN NO FAUCETS OR TOILETS WERE OPERATIONAL. THE AIRCRAFT LANDED AT DFWMar 31, 2023 · N410AN · Airbus A321253NXSDR 2023FA0000037Line · misinstalledACFT WAS UNDERGOING UNSCHEDULED MAINTENANCE TO TROUBLESHOOT COMPLAINTS, POTABLE WATER SYSTEM, HIGH CONSUMPTION, LOSS AND WATER - ICE ACCUMULATION AT CARGO DOOR THRESHOLD ON INSIDE. INSPECTIONS REVEALED WATER LEAKING, RESULTING FROM INCORRECT INSTALLATIONS OFJan 17, 2023 · N650AD · Cndair CL6002B16SDR R61A2023010200788Intercostal · corrodedWHILE AC WAS IN FOR HVY CK FOUND LOWER FUSELAGE III, 2 INTERCOSTALS PLUS 2 CLIPS CORRODED BETWEEN FR 86 AND FR 87, STR 28R AND 27R. REPLACED ANGLE AND INTERCOSTAL IAW SRM 51-41-02 SRM 51-41-01 MADE REPAIR PARTS FROM DRAWINGS 170-87562 AND 170-87563. PN 170-875Dec 6, 2022 · N657RW · Emb ERJ170100SESDR AALA202211282440Compressor · overheatedAIRCRAFT WAS GROUNDED: 1 HOUR INTO 2 HOUR FLIGHT, FLIGHT ATTENDANTS REPORT LAVATORY FUEL SMELL AFT CABIN AND AFT GALLEY . POSSIBLY RELATED LAVATORY SMOKE DETECTOR MOMENTARILY WENT OFF. WITH LAVATORY EMPTY. MAINTENANCE FOUND THE POTABLE WATER SYSTEM AIR COMPRESNov 24, 2022 · N546UW · Airbus A321231SDR AALA202211169766Faucet · leakingAIRCRAFT WAS GROUNDED: CLIMBING ABOVE 10000 FT FLIGHT CREW GOT A CALL FROM AFT FLIGHT ATTENDANT REPORTING A WATER FLOOD FROM THE RIGHT AFT LAVATORY. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO IAD WHERE IT LANDED SAFLEY. AFTER LANDING FIRST OFFICER Nov 10, 2022 · N647AW · Airbus A320232SDR AALA202211119766Lavatory · leakingAIRCRAFT WAS GROUNDED: CLIMBING ABOVE 10000 FT FLIGHT CREW GOT A CALL FROM AFT FLIGHT ATTENDANT REPORTING A WATER FLOOD FROM THE RIGHT AFT LAVATORY. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO IAD WHERE IT LANDED SAFLEY. AFTER LANDING FIRST OFFICER Nov 10, 2022 · N647AW · Airbus A320232SDR CALA2022072701894Compressor · odorCABIN CREW REPORTED ODOR ( LIKE RUBBER) IN CABIN ON ARRIVAL. FOUND CAUSE TO BE A FAILED POT WATER COMPRESSOR. REMOVED AND REPLACED POT WATER COMPRESSOR REF TASK 38-42-01-400-801 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1929375 SN OFF 9310 IPC REFERENCE # 38 Jul 25, 2022 · N27733 · Boeing 737724SDR CALA2022070601650Shutoff Valve · leakingMID GALLEY LEAKING WATER FROM CEILING. SLOWED AFT ER BOTH H2O VA LVES CLSD. ALL AREAS ABOVE THE GALLEY INSPECTED AND FOUND TO BE DRY AND CONDENSATION FOUND ON THE FILTER, CHILLER CATCH TRAY CONFIRMED LHR. INSULATION ABOVE GALLEY PEELED BACK AND CHECKED, NO DUSJul 6, 2022 · N76021 · Boeing 777224SDR QXEA2022061500223Waste Tank · inoperativeAFTER DEPARTING ORD FA'S CALLED AND INMORMED US THAT THE TANK FULL FAULT LIGHT WAS ILLUMINATED ON AFT FA PANEL BOTH LAVS WOULD NOT FLUSH. DIVERTED AND REMOVED FROM SERVICE. CYCLED POWER ON AIRCRAFT AND ALL LAVS FLUSH NORMAL. RESERVICED LAV AND C/W AMM TASJun 14, 2022 · N623QX · Emb ERJ170200LRSDR SWAA2022060614354Water Heater · smokeFLIGHT ATTENDANTS REPORT FWD LAV WATER HEATER OVERHEATING FOLLOWED BY FWD LAV SMOKE ALARM. NO SMOKE OR VAPING REPORTED. WATER HEATER WAS TURNED OFF AS A PRECAUTION / [01] OK TO CONTINUE PER MEL 38-2-02 SP1B. WATER HEATER OFF. LAV INOP;[02] REMOVED AND REPLACEDJun 2, 2022 · N8600F · Boeing 7378H4SDR CALA2022060201425Potable Water · odorWATER SUPPLY IN GALLEY SMELLS BAD POTABLE H2O TASTES AND SMELLS LIKE CHEMICALS MANY COMPLAINTS OF COFFEE TASTING TERRIBLE TOOK WATER SAMPLES THIS DATE PER EC/RA #:3810-01781 I DRAINED AND REFILLED POTABLE WATER SYSTEM THREE TIMES AND FLUSHED ALL LINESJun 2, 2022 · N37527 · Boeing 7379SDR QXEA2022051600193Galley · inoperativeFA REPORTS CHEMICAL SMELL AND SOAPY WATER IN BOTH GALLEY AND LAVS. NO SPECIFIC ODOR. MADE THEM COUGH AND CHOKE. POTABLE WATER ISSUE. REMOVED FROM SERVICE. FLUSHED POTABLE WATER SMELL CLEARED NO OTHER DEFECTS NOTED. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVIMay 15, 2022 · N634QX · Emb ERJ170200LR
Back to JASC 3810