JASC 3810
Service difficulty reports · 418
Reports filed under 3810 · Potable Water System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022042602955Water Heater · odorSHIP 682 -FUME- ACRID / BURNING ODOR IN 4R LAV DURING BOARDING. CORRECTIVE ACTION: REPLACED LAV WATER HEATER AND THERMOSTAT. C/W NO GO PROCEDURES.SDR CALA2022022400491Clamp · brokenREFERENCE 8020643, NEED TO ACCOMPLISH ECRA 2011-01000 DUE TO POTABLE WATER LEAK. NEED DEEP CLEANING FROM STA 19761FR47 TO STA 26695 FR64 DID INITIAL CLEAN UP ,NEED FURTHER CLEAN FROM STA19761FR47 TO STA26895FR64 WATER LEAK WAS CONFINED TO BELOW THE FLOOR FROM SDR SWAA2022021070609Water Heater · inoperativeAFT LAV SMOKE ALARM AT 8K ON APPROACH FA NOTICED ELECTRICAL SMELL. WATER HEATER AFT LAV FLASHING YELLOW. NO EVIDENCE OF FIRE. / [01] PERFORMED CONDITIONAL INSPECTION AMM 05-51-56. SEE LOG PAGE 1883562 FOR INOP WATER HEATER. AC OK FOR SERVICESDR DALA2021122908158None · noneSHIP 0669 -ATB- DUE TO WATER LEAK IN AFT LEFT LAV (LOC 203). UNABLE TO SHUTOFF/ISOLATE. / CORRECTIVE ACTION: FOUND WATER SUPPLY WIGGIN FITTING DISCONNECTED UPSTREAM OF SUPPLY SHUTOFF VALVE. RE-SECURED WIGGIN FITTING, SERVICED POTABLE WATER SYSTEM AND LEAK CHECSDR ASAA2021122536994Unknown · noneAFTER TAKEOFF FA'S REPORT NO WATER AND NO WASTE OPERATION. GROUNDED - YES. DIVERSION TIME 27 MINUTES. PERFORMED B737-800 FIM 38-10 TASK 803. NO SYSTEM FAULTS. HAD RAMP RESERVICE POTABLE WATER CORRECTLY (PREVIOUSLY SERVICED INCORRECTLY). GROUND CHECKED LAVS ANDSDR DALA2021121607783None · noneSHIP 5635 LAV WATER CAUSES SHOCK WHEN WASHING HANDS AND TOUCHING BIFOLD DOOR / INTERIOR. CORRECTIVE ACTION: REPLACED WATER HEATER CHECKS GOOD PER B757 AMM 38-13. (2052205)SDR CALA2021121002340Potable Water · inoperativeNO WATER PRESSURE IN LAVS OR GALLEYS. FOUND AIR COMPRESSER BRAKER OUT, RESET CB WATER SYSTEM CHECKS NORMAL AT THIS TIME. AIRCRAFT HAD WATER SYSTEM CLEANING ON THE OVERNIGHT.SDR CALA2021112502172Potable Water · closedNO WATER PRESS FROM 2L FWD IN BOTH LAVS AND GAL LIES.AFT LAVS/GA LLIES OK FOUND POTABLE WATER VALVE AT 4LEFT ABOVE DOOR IN THE CLOSED POSTION. SEE PHOTO ATTACHED. MOVED VALVE HANDLE TO OPEN POSTION. PURGED AIR FROM ALL GALLEYS AND LAVS AND WATER PRESSURE GOOSDR DALA2021101806395Compressor · odor(LOG 8066450) DURING PREPARATION FOR BOARDING, CABIN SERVICE REPORTED BURNING ELECTRICAL SMELL IN CABIN TOWARDS MID AFT CABIN. MAINTENANCE REMOVED AND REPLACED POTABLE WATER COMPRESSOR PER B737 AMM 38-42. OPS CHECK OK, NO FUMES.SDR AALA202106029017Relay · faultyAIRCRAFT WAS GROUNDED: NO POTABLE WATER FLOW, FLIGHT DECLARED EMERGENCY AND RETURNED TO FIELD. REPLACED RELAY K38018 WITH NEW, OPS CHECK GOOD.SDR AALA202105309004Drain Valve · leakingAIRCRAFT WAS GROUNDED: WATER TANK WENT FROM FULL TO COMPLETELY EMPTY WITHIN 25 MIN OF TAKEOFF. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHX WHERE IT LANDED SAFELY WITHOUR FURTHER INCIDENT.REPLACED FORWARD DRAIN VALVE AND ACCOMPLISHED A SATISFACOSDR AALA202105059009Heater · faultyAIRCRAFT WAS GROUNDED: AFTER TAKEOFF, BURNING RUBBER ODOR REPORTED IN AFT GALLEY. REPLACED AFT WATER HEATER IAW AMM 38-13-01, OPS CHECK GOOD.SDR ASAA2021042934727Control Cable · brokenON CLIMBOUT, FA REPORTED NO WATER PRESSURE IN ANY OF THE LAVATORY SINKS OR TOILETS. GROUNDED - YES. DIVERSION TIME 29 MINUTES - FOUND WATER TANK FILL VALVE LOOSE AND ALLOWING FILL VALVE TO LOOSE PRESSURE (SUSPECT BAD VALVE CONTROL CABLE). REMOVED AND REPLACED SDR CALA2021042600543Valve · leakingPOTABLE WATER DRAINED IN FLT UPON A/C ARRIVAL, OPENED WATER SERVICE PANEL AND A BLOCK OF ICE FELL OUT ALONG WITH A FEW DROPS OF WATER FROM THE FILL PORT. OVERFLOW AND BELLY DRAINS WERE ALL DRY. CHECKED POTABLE WATER TANK AND SURROUNDING AREA, FOUND NO EVIDENCESDR 2021FA0000096Shutoff Valve · seizedITT SHUTOFF VALVES PART NUMBER AV24B1606T-08 VALVE SEIZURE.SDR 2021FA0000095Shutoff Valve · seized3 EACH, ITT SHUTOFF VALVES PART NUMBER AV24B1606T-08 VALVE SEIZURE,SDR DALA2020111603738Water Heater · odorBURNING ODOR AT FORWARD LAV. CORRECTIVE ACTION: REPLACED HOT WATER HEATER.SDR DALA2020100903325Water Heater · malfunctionedDIV - DUE TO ELECTRIC SMELL COMING FROM F/C LAV NO VISIBLE SMOKE. ISOLATED TO OVERHEATING OF LAVATORY WATER HEATER THERMOSTAT. CORRECTIVE ACTION: DEFERRED WATER HEATER TO MEL AND LOCKED OUT FWD LAVATORY. (10/8 ATL) REPLACED HOT WATER HEATER AND THERMOSTAT. (10SDR AALA2020081749015Water Heater · faultedAIRCRAFT WAS GROUNDED: BURNING SMELL FROM MID LAVATORY REPORTED DURING DESCENT, NO VISIBLE SMOKE OR HEAT PRESENT. UPON TROUBLESHOOTING, REPLACED WATER HEATER WITH NEW IAW AMM 38-12-16.SDR AALA202007289017Water Heater · overheatedAIRCRAFT WAS GROUNDED: AFT RIGHT LAV WATER HEATER VERY HOT WITH SLIGHT BURNING SMELL. REMOVED AND REPLACED ON AFT RIGHT LAV THE WATER HEATER AND OPERATIONAL AND LEAK CHECK GOOD IAW AMM 38-13-01.SDR CALA2020032100678Valve · inoperativeWATER NOT FLOWING IN LAVS AND GALLEYS UPDATE: POTABLE WATER TANK SERVICED UNTIL OVERFLOW AT DRAIN. ALSO QUANTITY SHOWS FULL ON CABIN INDICATION GAUGE. REPLACED BLEED AIR FILTER ELEMENT REF AMM 38-42-10-960-801 REPLACED PRESSURE REGULATOR REF AMM 38-42-08-400-8SDR VNAA202002241101Blanking Plate · damagedAFT LAV SINK CONTINUOUSLY RUNNING 25 MIN OUT FROM VPS. THE POT WATER RAN OUT AND MADE THE THE MOTOR OVER HEAT. THE CREW RAN THE QRH AFTER THE RECEIVED AN AFT LAV SMOKE DETECTOR WARNING MESSAGE. THEY DID DECLARED AN EMERGENCY AND TRUCKS DID ROLL BUT NOT NEEDED SDR Y9PA2020020620Drain Valve · leakingAFTER FLIGHT CREW SQUAWKED PORTABLE WATER TANK LEAKING INTO BILGE WATER OBSERVED DRIPPING FROM FWD FUSELAGE DRAIN HOLE. UPON INSPECTION BY TECHNICIANS DISCOVERED THAT THE FILL DRAIN VALVE (PN DO5A00, SN 2553, DATED 10/99, MANUFACTURED BY C3406 GKN WESTLAND-SITSDR DALA2020011400244Water Heater · failedSHORTLY AFTER TAKE OFF FORWARD LAV DETECTOR ALARM SOUNDED WITH SMOKE INDICATION IN LAV. INSPECTED ALL LAVATORY COMPONENTS. FOUND LAV WATER HEATER TO BE SOURCE OF SMOKE/SMELL. C/W NO GO ODI PREVENTION 2127 AND WC 2120 -2367. R&R'D F/C LAV SINK WATER HEATER PER SDR IPXA2020011500935Line · rupturedRUPTURE IN SINK WATER SUPPLY LINE, DURING CRUISE WATER TANK EMPTIED ONTO FLOOR. DIVERTED IAW AMC REQUEST. R & R THE LAV BASIN FAUCET ASSY. OP & LEAK CHECKED GOOD IAW AMM 38-11-08.SDR CALA2019120902167Potable Water · low pressureAIRCRAFT LOST ALL POTABLE WATER PRESSURE AFTER TAKEOFF. CREW FOUND FAULT LIGHT ON AFT ATTENDANT PANEL FOR COMPRESSOR, CREW SELECTED OVERRIDE BUT NO HELP. ITEM HAS PREVIOUS HISTORY ITEM PLACED ON MEL 3810AN WATER SYSTEM DEFERRED PER THE MEL DDP COMPLIED WITH ACSDR ASAA2019112533435Valve · not closedF/A REPORTS NO POTABLE WATER FOR COFFEE MAKER OR SINKS. GROUNDED - YES. AIR TURNBACK - DIVERSION TIME 30 MINUTES - TROUBLESHOOT IN REF TO B737-800 FIM 38-10 TASK 803 FOUND FILL/OVERFLOW VALVE NOT CLOSING COMPLETELY AND LEAKING WHEN SERVICE DOOR CLOSED. REMOVSDR AALA2019101769023Water Heater · failedAIRCRAFT WAS GROUNDED: PILOT REPORTS SMOKE. LAV SMOKE AURAL ALERT ALERTED " TURNED OFF WATER HEATER AND DISCONNNECTED CANNON PLUG" SMELL WAS COMING FROM LOWER VANITY. MAINTENANCE REMOVED AND REPLACED LAV L62 WATER HEATER IAW AMM 38-12-000-801B. OPS CHECKS GOODSDR AALA2019100219019Water Heater · sparksAIRCRAFT WAS GROUNDED: GATE AGENT REPORTED OBSERVING ELECTRICAL SPARKS AND AMBERS HITTING FLOOR AFT LEFT LAV. MAINTENANCE REMOVED AND REPLACED L AFT WATER HEATER IAW AMM 38-12-16 AND OPS CHECKED IAW AMM 38-12-00 .SDR DALA2019092505499Tie Rod · not reportedSHIP 1815 - DIV - TO DEN DUE TO LOSS OF POTABLE WATER. CORRECTIVE ACTION: DEFERRED PER MEL 38-10-01B. REPLACED WATER TANK 2 FORWARD MOUNTING TIE RODS, BOTTOM HEATED HOSE, AIR COMP HOSE AS PER IPC 28-15-01-07. WATER TANK SECURED. REPLACED CHILLER TIE ROD. LP 65SDR AALA2019080869020Water Heater · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS FORWARD LAV HAS AN ODOR OF RESIDUAL ELECTRIC SMOKE OR CHARING. NO EVIDENCE OF ANY ACTIVE ISSUE ON THIS FLIGHT. MAINTENANCE REMOVED AND REPLACED FWD LAV WATER HEATER IAW AMM 38-13-01. OPS CHECK GOOD.SDR AALA2019080539010Water Heater · odorAIRCRAFT NOT GROUNDED: PILOT REPORTS COCKPIT SMOKE LIGHT CAME ON MOMENTARILY, F/A REPORTED THE AFT RIGHT LAV SMELLS LIKE BURNING RUBBER BUT COULD NOT CONFIRM ANYTHING REALLY. MAINTENANCE REMOVED AND REPLACED AFT RH LAV WATER HEATER IAW AMM 38-13-01. NO FURTHERSDR VNAA2019071711101Pan · contaminatedCREW REPORTED STRONG ODOR IN FLT DECK/VOMMIT/DEAD ANIMAL. MX LOOKED AT THE AIRCRAFT AND DETERMINED IT WASNÏ¿½T A MX ISSUE. AIR CREW REFUSES THE AIRCRAFT. CONTACTED PEST CONTROL. THEY ARE SENDING OUT A TECH TO INSPECT FOR DEAD ANIMALS. UPON INSPECTION FOUND ODOSDR DALA2019062603962Compressor · overheatedELECTRICAL FUMES DETECTED AFT OF ROW 40 AFTER PASSENGERS DISEMBARKED. FOUND POTABLE WATER COMPRESSOR OVERHEATED AND EMANATING ELECTRICAL FUMES. PULLED AND SECURED POTABLE WATER COMPRESSOR C/ B AND FWD TO MEL 38-10-01A. REPLACED POTABLE WATER COMPRESSOR. SYSTEMSDR CALA2019052000808Compressor · inoperativeNO WATER IN GALLEYS AND LAVS WHEN AIRBORNE BUT WORKS ON GROUND WHEN LANDED REMOVED AND REPLACED THE H2O SYSTEM UNDERLOADER CHECK VALVE, FOUND BAD. PRESSURIZED THE SYSTEM WITH 1 ENG IDLE, OPS CHECK GOOD. H2O AIR COMPRESSOR INOP. REMOVED AND REPLACED THE AIR COMSDR AALA201904259001Water Heater · faultyAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS SMOKE SMELL IN FWD PORTION OF CABIN GALLEY/ LAV AREA. MAINTENANCE REMOVED AND REPLACED FWD LAV WATER HEATER IAW 38-12-16. LEAK CHECK PERFORMED, CHECKS GOOD.SDR AALA2019030428009Turnbuckle · looseCAPTAIN REPORTED AN UNUSUAL VIBRATION IN AFT OF AIRCRAFT AFTER TAKE OFF. THE AIRCRAFT WAS GROUNDED. MAINTENANCE FOUND THE AFT POTABLE WATER TANK VIBRATING WHILE THE ENGINES ARE RUNNING ABOVE IDLE DUE TO TURNBUCKLE CABLE ASSEMBLY LOOSE AND THE FOAM BLOCKS TSDR AALA2019030126002Packing · cutTHE POTABLE WATER WAS LEAKING FROM THE SUPPLY LINE IN THE 4F-RC LAVATORY INTO THE CABIN. AN EMERGENCY WAS DECLARED AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS GROUNDED. FOUND THE COUPLING SEAL WAS CUT. REPLACED THE SEAL IAW AMM 38-10-01-910-803.SDR CALA2019020800231Limit Switch · stuckFA REPORT WATER LEAKINGFROM BOTH FWD/AFT GALLEYWATER QNTY 100 AT T/OLEAK TO 0 CHECKED POTABLE WATER SYSTEM PER TSM 38-12-00-810-815A. DRAINED AND FILLED TANK AND VERIFIED QUANTITY INDICATION CORRECT. PRESSURIZED TANK AND LEAK CHECKED ALL GALLEY AND LAV WATER SDR DALA2019020500769B-Nut · leakingSHIP 6716 - SMOKE/FUME - LAVATORY SMOKE WARNING AND VISIBLE ODOR/SMOKE FROM RT MID LAV. CORRECTIVE ACTION: FOUND LOOSE B NUT FOR POTABLE WATER LEAKING ON TV MONITOR MOUNTED ON BULKHEAD WALL. TIGHTENED B NUT AND REPLACED MONITOR.SDR SIMA201811298001Nipple · overheated"TRANSFERRED FROM AML PAGE 4343084 ITEM 1" AFTER APU START AND OPERATING PACK 2 FOR APPROX 3 MINUTES, SMELLED ELETRICAL HEAT/BURNING SMELL WHILE AT THE GATE. F/A REPORTED SMELL BY SEAT 3A FORWARD AND SMELL IN COCKPIT ALSO. NEGATIVE DE-ICE ON ORIGINATION FLIGHTSDR CALA2018102702182Clamp · defectiveFOUND WATER LEAK IN FWD GALLEY RT SIDE BTM SUPPLY CONNECTION. REPLACED ORINGS AND CLAMP. REQUIRES LEAK CHK. UNABLE TO GET WATER SVC AT THIS TIME. WATER SYSTEM SERVICED AND NO LEAKS NOTED. PANEL CLOSED.SDR AALA201807249019Water Heater · smokeAIRCRAFT WAS GROUNDED: SMOKE LAVATORY DETECTOR ALERT AND CONFIRMATION OF SMOKE, ISOLATED WATER HEATER TO STOP SMOKE. MAINTENANCE REPLACED WATER HEATER IN THE MID LAVATORY PER AMM 38-12-16 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR ASAA2018033124091Valve · malfunctionedDURING CLIMBOUT, FA STATED WATER PRESSURE IN LAVS AND WATER DISPENSED WITH COFFEE MAKERS LOW PRESSURE, THROUGHOUT AIRCRAFT. ACFT GROUNDED. AIR TURNBACK. OPENED THE WATER SERVICE PANEL, CYCLED WATER DRAIN VALVE OPEN THEN CLOSED. WATER PRESSURE & FLOW NORMSDR CNMA2018020001Clamp · looseEICAS MESSAGES CABIN AUTO INOPERATIVE, CABIN ALT AUTO 1 AND CABIN ALT AUTO 2 SHOW AND AUTO INOP LIGHT IS ON. UNABLE TO CONTROL OUTFLOW VALVE IN MANUAL MODE. FOUND WATER LEAKING ONTO THE OUTFLOW VALVE. FOUND BROKEN CLAMP ON GALLEY LINE R & R CLAMP IAW AMSDR AALA201801029035Valve · unserviceableTHE AIRCRAFT WAS GROUNDED. NO WATER IN LAVATORIES OR COFEE MAKERS. THE FLIGHT DIVERTED. AN EMERGENCY WAS DECLARED DUE TO OVERWEIGHT LANDING. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE EVALUATED AIRCRAFT AND FOUND EVIDENCE OF ICE ON EXTERIOR OF FUSSDR DALA2017102907894Line · leakingEXPERIENCED SMOKE AND FUMES IN THE AC CABIN AFTER PUSHBACK. FLIGHT CREW HAD TUG DRIVER RETURN AC TO JETWAY AND PASSENGERS DEPLANED NORMALLY. MAINTENANCE FOUND A CRACKED WATER LINE ABOVE THE WATER HEATER LOCATED IN THE F/CLASS LAV. THE WATER LINE WAS DRIPPINGSDR AALA201710259019Water Heater · failedAFT RIGHT LAVATORY HAD AN ARID SMOKE ODOR, F/A PULLED WATER HEATER CIRCUIT BREAKER, ODOR STOPPED. REMOVED AND REPLACED LAVATORY HOT WATER HEATER IAW AMM.SDR CALA2017082702902Water Heater · odorAFT LEFT LAV HAS SMOKE ODOR SEVERAL PAX SAID THEY SMELLED IT ALSO. CLEANED AFT LEFT LAV WATER HEATER AND SURROUNDING AREA AND TURNED UNIT TO A LOWER SETTING. OBSERVED FOR SEVERAL HOURS. OPS TEST NORMAL.SDR CALA2017072102307Valve · faultyAFT COFFEE MAKER POURING OUT WATER. LOUD PUMP NOISE ELECTRIC SMELL. SHUT OFF VALVE INOP REPLACED AFT GALLEY WATER SUPPLY SHUTOFF VALVE, NO LEAKS NOTED. FOUND I/B COFFEE MAKER M42 SUPPLY LINE LEAKING, SECURED B-NUT NO LEAKS NOTED.
Back to JASC 3810