JASC 3810
Service difficulty reports · 418
Reports filed under 3810 · Potable Water System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201707209038Water Heater · faultyTHE AIRCRAFT WAS NOT GROUNDED. 3L LAV HAD A VERY STRONG ELECTRICAL SMELL, NO SMOKE OR HEAT. TURNED OFF WATER HEAT. SO STRONG THE ODOR, WE MOVED PASSENGERS. INSPECTED LAV 3F-1L. CEILING AND MIRROR LIGHTS CKS OK. REMOVED AND REPLACED LAV WATER HEATER PER ASDR AALA201707059009Water Heater · odorAIRCRAFT WAS NOT GROUNDED. BURNING ODOR IN AFT RIGHT LAVATORY. REPLACED AFT RIGHT LAVATORY WATER HEATER PER AMM 38-12-16.SDR DALA2017062805041Water Heater · defectiveAFT LT LAV SMOKE DETECTOR GOING OFF. R&R 3 SMOKE DETECTORS NO HELP 609925. R&R WATER HEATER PER AMM 38-14. PERFORMED DUCT BURNOUT AND REPLACED COALESCER BAGS.SDR DALA2017070505221Selector Switch · shortedSMOKE CAME FROM ROW 1DC LOWER WALL VENT. ON ACFT POWER UP. FOUND WATER QUANTITY MODE SELECTOR SWITCH SHORTED. REPLACED FILL VENT VALVE (M1-75). ALL CHECKED GOOD.SDR ASAA2017052920926Water Heater · failedONE HOUR INTO CRUISE AT FL 320, F/A REPORTED FUMES IN BOTH AFT LAVATORIES. OVER TIME FUMES INCREASED IN INTENSITY AND F/A REPORTED EYE IRRITATION AND HEADACHES. ACFT GROUNDED. ACCOMPLISHED CABIN ODOR TROUBLESHOOTING IAW AMM 05-51 TASK 814 CONDITIONAL INSPECSDR SIMA20170529001Drain Valve · stuckDURING CLIMB PASSING 17000FT, FA CALLED TO REPORT A LOUD RUSHING AIR SOUND COMING FROM AFT GALLEY SINK. PERFORMED AN EMERGENCY LANDING WITHOUT FURTHER PROBLEMS. INSPECTED AND FOUND AUTO DRAIN VALVE STICKING. CYCLED THE AUTO DRAIN VALVE IAW AMM 38-31-04. OPSDR P5CA2017033100081Toilet · inoperativeCREW REPORTED TOILET WOULD NOT OPERATE IN FLIGHT. AIRCRAFT RETURNED TO DEPARTURE AND THE SYSTEM WAS RESET AND RESTORED IAW AMM 38-32-06.SDR CALA2017032700746Compressor · faultyELECTRICAL BURNING SMELL IN AFT CABIN AREA. TURNED OFF ALL CABIN LIGHTS AND SMELL DID NOT GO AWAY. CHECKED L FOUND SMELL STRONGEST AT ZONE E RIGHT SIDE ROWS 40-45, FOUND ALL WHILE PERFORMING INSPECTIONS PER AMM 05-51-58 FOUND ELECTRIC LAVATORY AND GALLEY LIGHTSDR AALA20170315001Retainer · leakingAIRCRAFT WAS GROUNDED. EMERGENCY DECLARED. NRT-DFW FLIGHT RETURNED TO NRT ACCOUNT NO POTABLE WATER IN THE MID GALLEY AND MID LAVATORIES. OVERWEIGHT LANDING UNEVENTFUL. FOUND WATER LEAK FROM FORWARD CARGO WATER DRAIN LINE. REPLACED RETAINER AND REINSTALLEDSDR AALA201701239009Water Heater · odorAIRCRAFT WAS NOT GROUNDED. FORWARD LAVATORY HOT WATER HEATER SMELLS LIKE IT IS BURNING. MAINTENANCE REPLACED WATER HEATER PER AMM 38-12-16.SDR CALA2017012000129Compressor · burnedELECTRICAL ODOR AND SMOKE IN AFT CABIN. RT RECIRCULATION FAN INOPERATIVE. PERFORMED SMOKE IN THE CABIN CONDITIONAL INSPECTION IAW AMM TASK 05-51-58-910-801C1, REPLACED POTABLE WATER COMPRESSOR. OPS CHECKED GOOD IAW AMM 38-15-01. REMOVED AND REPLACED RIGHT RESDR HALA2016112000209Water Heater · leakingDIVERTED DUE TO UNCONTROLLABLE WATER LEAK AT L4 DOOR LAV BENEATH THE WATER HEATER LINE. REPLACED WATER HEATERSDR AALA201611159002Water Heater · failedDURING DESCENT, FLIGHT ATTENDANT CALLED TO SAY THAT A PASSENGER SMELLED ACRID ODOR IN THE FORWARD LAVATORY. ON LANDING THERE WAS A BURNED ELECTRICAL ODOR STILL LINGERING IN THE FORWARD LAVATORY. MAINTENANCE REPLACED THE FORWARD LAVATORY WATER HEATER IAW AMM SDR HALA2016072800147Potable Water · unknownAIRCRAFT 388, ATB DUE TO POTABLE WATER AT DEPARTURE WAS 75% AND DROPPED TO 37% 15 MINUTES LATER. MAINTENANCE FOUND POTABLE WATER TANK QUANTITY AT 75% ON ARRIVAL, SERVICED TANKS TO FULL WITH NO LEAKS FOUND AND INDICATION NORMAL.SDR AALA20160716001Potable Water · lowDURING CRUISE CREW REPORTED A TOTAL LOSS OF POTABLE WATER. EMERGENCY DECLARED. LANDING UNEVENTFUL. SERVICED POTABLE WATER. NO LEAKS NOTED. OPS CHECKED NORMAL.SDR C77A20160713002Compressor · odorDURING FLIGHT, THERE WAS AN ODOR OF BURNING PLASTIC. THE AIRCRAFT DIVERTED AND AN EMERGENCY WAS DECLARED. FOUND PROBLEM TO BE CAUSED BY POTABLE WATER SYSTEM AIR COMPRESSOR.SDR AALA20160503004Pump · inoperativeAIRCRAFT WAS NOT GNDED. AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. DURING FLIGHT NO POTABLE WATER WAS AVAILABLE. FOUND POTABLE WATER SYS PUMP INOPERATIVE. R & R POTABLE WATER PUMP IAW AMM 38-10-02. OPS CHECK GOOD.SDR DALA2016042803547Relay · corrodedHOT AND COLD RELAY FOR WATER HEATER CORRODED AT MID LT LAV. CORRECTED LOOSE B-NUT ON RELAY AND REPLACED HOT/COLD SOLENOID CONTROL VALVE REF CMM.SDR AALA20160424005Potable Water · inoperativeAIRCRAFT WAS NOT GNDED. AIR INTERRUPT, DURING CRUISE THE POTABLE WATER & ALL LAVATORIES BECAME INOPERATIVE. FOUND POTABLE WATER & LAVATORY SYSTEMS REQUIRED SERVICING. SERVICED POTABLE WATER & LAVATORY SYSTEMS.SDR UIEA2016030500117Compressor · faultySMELL OF FUMES AT 0200Z DURING FLIGHT. PERFORMED CHECKLIST. FUMES NOT PRESENT WITH UTILITY BUSSES OFF. DURING TROUBLESHOOTING, FOUND AIR COMPRESSOR FOR POTABLE WATER SYS AT FAULT, ITEM DEFERRED. TRANSFERRED ITEM IAW DDG 38-10-01A.SDR MASA2016022212785Potable Water · unsanitaryAFT COFFEEMAKER, BURNED RUBBER ODOR. MAINTENANCE FOUND POTABLE WATER BAD, DRAINED. RESERVICED, NO ODOR.SDR DALA2016022301343Potable Water · leakingON DESCENT, AT 250 KTS WITH WINGS LEVEL, THE SPOILERS WERE EXTENDED TO EXT POSITION. AFTER A FEW SECONDS, THE SPOILER HANDLE SNAPPED BACK TO THE FORWARD POSITION. WHEN PULLING THE SPOILER HANDLE BACK TO THE EXT POSITION, THE AIRCRAFT ROLLED 20 DEGREES TO THESDR AALA201602189001Filter · leakingAIRCRAFT WAS GNDED. CABIN CREW REPORTED AN ODOR IN THE AFT CABIN. ACCOMPLISHED CABIN AIR QUALITY TROUBLESHOOTING TASK CARD 33L00021001 & SUSPECT DIRTY SOCK SMELL WAS RELATED TO A REAR GALLEY WATER FILTER LEAK WHICH WAS ON MEL. TIGHTENED THE WATER FILTER CANSDR AALA201602179010Water Heater · malfunctionedAIRCRAFT WAS GNDED. ODOR DETECTED IN FWD LAVATORY DURING DESCENT THROUGH 10,000. ELEC OR OZONE TYPE SMELL. ACCOMPLISHED JC 26L00021001 TROUBLESHOOT CABIN AIR QUALITY. ISOLATED SOURCE OF ODOR TO FWD LAVATORY WATER HEATER. REPLACED FWD LAVATORY WATER HEATER SDR CALA2015121801007Water Heater · leakingWATER LEAKING FROM FWD LAVATORY, FLOODED FWD GALLEY IAW NR 4945615 FOR REPAIR OF LEAK. ACCOMPLISHED CLEANUP OF POTABLE WATER SPILL IAW ECRA 2011-0100, LAVATORY & GALLEY SPILL STEP 2 A & 2 B, IN-DEPTH CLEAN UP. PLACED ON DIP TO PERFORM HEAVY SUPPLEMENTAL INSPSDR QXEA2015121200646Drain Mast · damagedPREPARING TO TAXI, AS THE PROPS CAME UP TO SPEED AND THE ACFT GENERATORS CAME ON-LINE, GROUND CREW FRANTICALLY SIGNALED TO CUT ENGINES. YANKED FUEL LEVERS TO FUEL CUT-OFF. CONSULTED WITH GROUND CREW, THEY SAID THE ACFT WAS THROWING SPARKS OFF OF ITS BELLY FRSDR CALA2015121800998Water Heater · leakingLAVATORY G SINK CABINET WATER HEATER LEAK. WPB V913651 REF LOG 6687792 FOR CLEANUP. REPLACED WATER HEATER WITH PN OFX5000A03G01. WPB V913650 ROTABLE PARTS CHANGE WAS INDICATED, TT 1714901, SN OFF 01786 IPC REFERENCE 38-00-00.SDR YENA20151029535Water Heater · smokeDURING CRUISE FLIGHT, LAV H SMOKE INDICATION ON F/A PANEL APPEARED SMOKE WAS FROM WATER TANK. HEATER WAS SWITCHED OFF NO FURTHER INDICATION. R & R WATER HEATER IAW AMM 38-12-16 LEAK CHECK GOOD, OPS NORMAL.SDR AALA20151019002Water Heater · malfunctionedACRID FUMES SMELL IN COCKPIT AFTER TAKEOFF, ALSO SMELL IN CABIN OF ACFT. THE FLIGHT DECLARED AN EMER & RETURNED TO FIELD WITHOUT FURTHER INCIDENT. ACFT WAS REMOVED FROM SERVICE. R & R THE FWD LAVATORY WATER HEATER IAW AMM 38-12-16. OPERATIONALLY CHECKED OKSDR ASMF201511001Module · damagedAIRCRAFT RETURNED OF FLIGHT DUE TO DURING CLIMB, THERE WAS NOT POTABLE WATER IN THE LAVATORIES. PERFORMED REVISION TO LAVATORIES IAW FIM DMC-B787-A-38-10-F1-73A-421A-A PROCEDURE, SHOWING FAILURE CODE 38-12669, DETECTING THE POWER MODULE RPDU41 DAMAGED. THE PSDR AALA201509129010Water Heater · odorFLIGHT ATTENDANTS REPORT SMELL OF MELTING PLASTIC IN AFT RT LAVATORY. SMELL TO BE DETERMINED FROM NEW HOT WATER HEATER. NO DEFECTS NOTED. HOT WATER HEATER OPERATIONS NORMAL.SDR WX0A2015081172785Water Heater · overheatedELECTRIC BURNING SMELL COMING FROM AFT LAVATORY, ACFT RT. MEL 38-10-01A CAT C LAVATORY E HOT WATER DEACTIVATED. TROUBLE SHOT IAW TSM 05-50-00-810-831-A. FOUND LAVATORY E WATER HEATER OVERHEATING. PLACARD INSTALLED.SDR AALA20150703008Potable Water · lowAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CRUISE THE POTABLE WATER SYS WAS FOUND TO BE INOPERATIVE. SERVICED POTABLE WATER TO FULL. NO LEAKS NOTED. SYS CHECKED NORMAL.SDR CA150615004Regulator · failed(CAN) DURING TAKEOFF ROLL, FLIGHT ATTENDANT WITNESSED A LOUD SCREECHING & POPPING SOUND FROM THE GALLEY COFFEE MAKER & WATER SPILLING ONTO THE FLOOR. THE FLIGHT ATTENDANT PUSHED EMER CALL BUTTON & CREW REJECTED TAKEOFF. MX TROUBLESHOOTING DETERMINED THAT THESDR R61A201505100308Drain Valve · corrodedDURING HEAVY CHECK, FWD DRAIN VALVE CORRODED. MAINTENANCE R & R FWD DRAIN VALVE AMM 38-11-09.SDR CALA2015051193762Water Heater · malfunctionedCREW REPORTS SMOKE & ODOR FROM FWD AFT LAVATORY UNDER SINK AREA. SMOKE WAS WHITE WITH ACRID ELEC TYPE SMELL. FLIGHT ATTENDANT DISCHARGED A HALON EXTINGUISHER UNDER SINK AT WATER HEATER & TOWARD AFT AREA OF COMPARTMENT. NO CB'S TRIPPED IN FLIGHT DECK. INSPESDR SWIA201540600Potable Water · leakingDURING APPROACH, LEFT AILERONS JAMMED. DISCONNECTED THE AILERON CONTROLS AND LANDED WITHOUT INCIDENT, NO EMERGENCY DECLARED. FORWARD POTABLE WATER SYSTEM HAD LEAKED, FLOODING THE BELLY UNDER THE FWD CARGO BAY. THE WATER HAD ENCAPSULATED THE CAPTAIN`S AILERONSDR CWQA20141203001Drain Line · overheatedDURING DESCENT, CREW WAS INFORMED OF HOT ELEC & SMOKE SMELL COMING FROM BAGGAGE AREA. CHECK LIST FOLLOWED, CONTINUED DESCENT & APPROACH TO DESTINATION. MX EVALUATION FOUND OVERHEATED AFT, WATER, HEATED DRAIN LINE ASSEMBLY AS SOURCE OF OVERHEAT & BURNING SMELSDR DALA2014112206215Indicator · corrodedCORROSION ON WATER QUANTITY INDICATOR LOCATED INTERNAL AREA ACCESS DOOR NR 171AL. REPLACED WATER QUANTITY INDICATOR.SDR CA141010018Heater · burned(CAN) WHEN DOING MAINTENACE WITH THE EXTERNAL POWER CONNECTED, THE AVIONIC TECHNICIAN SMELLED SMOKE COMING FROM THE CABIN. AFTER DISCONNECTING THE EXTERNAL POWER AND THE SMOKE WAS GONE, THEY FOUND OUT THAT THE CAUSE WAS THE WATER LINE HEATER AND THE SURROUNDISDR USAA2014092400002Water Heater · unserviceableSMELL OF BURNT PLASTIC IN AREA OF FWD LAVATORY. FWD LAVATORY TRASH BIN CHECKED WITH NOTHING BEING FOUND. MEL'D THE LAVATORY WATER HEATER IN LAVATORY A. R & R IAW AMM 38-12-16 PB 401. OPERATIONS CHECKED NORMAL. CLEARED MEL.SDR O2GA2014FA0000424Water Heater · leakingAT 40,000 FT CRUISE ALTITUDE, DURING FLIGHT NR 2 THROTTLE WENT TO FULL THROTTLE AND THROTTLE LEVER WOULD NOT MOVE. DESCENDED THRU 23,000 FT AND THROTTLE LOOSENED UP. DECISION WAS TO CONTINUE FLIGHT AND WAS UNEVENTFUL LANDING. INVESTIGATION FOUND THE LAV SINK SDR DALA14028109018Water Heater · failedFLIGHT WAS DIVERTED DUE TO FUMES COMING FROM FIRST CLASS LAVATORY. MAINTENANCE FOUND THE FIRST CLASS LAVATORY WATER HEATER INTERNAL WIRING CHARRED AND CONNECTOR P1-385 DISCOLORED. REPLACED BOTH THE CONNECTOR AND THE WATER HEATER.SDR CALA2014041490815Valve · failedNO WATER PRESS ON ENTIRE ACFT BUT WATER IS FULL. FOUND OVERFLOW DRAIN VLV IN THE OPEN POSITION AT FWD WATER DRAIN PANEL. NEEDS VLV REPLACEMENT, REPLACED OVERFLOW VLV IAW AMM 38-14-44, LEAK CHECKED & OPERATIONS CHECKED NORMAL. WATER PRESS OK.SDR CALA2014040390750Potable Water · leakingPOTABLE WATER LEAKING FROM BELLY OF ACFT NEXT TO HYD RESERVOIR FILLING PANEL.SDR UHLA2014022800173Line · leakingCREW REPORTED AILERONS JAMMED IN FLIGHT, CAPTAIN SIDE. PULLED DISCONNECT, F/O SIDE FREE. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. FOUND CAPTAIN SIDE AILERON CABLES FROZEN IN ICE DUE TO LEAK FROM GALLEY SINK DRAIN LINE. THAWED CABLES AND OPS CHECK IAW AMSDR R61A201401230203Spigot · corrodedDURING HEAVY CHECK, AFT GALLEY WATER SPIGOT NOZZLE HAS SIGNS OF CORROSION. MX R & R AFT GALLEY WATER SPIGOT NOZZLE IAW AMM 25-34-01, PN 90043-407.SDR USAA2014012100007Water Heater · sparksMAINTENANCE REPORTED THE AFT RT LAVATORY WATER HEATER EMITS SPARKS. R & R AFT RT LAVATORY WATER HEATER IAW AMM 38-12-16-000-0001, OPERATIONS CHECKED GOOD.SDR ASMF201402008Door · openAIRCRAFT PERFORMED AN UNSCHEDULED LANDING AT MID DUE TO DURING CRUISE THERE WAS NO POTABLE WATER IN GALLEY OR LAVATORIES & THE INSTRUMENT INDICATED 3 /4 FULL. DURING MX REVISION, THE WATER TANK ACCESS DOOR PANEL NR 146ARY WAS DETECTED OPENED. SO THE PANEL WASDR CALA2014010290027Hose · leakingPOTABLE LEAKING NO PRESS. HOSE REPLACED LEAK CHECKED OK FOR SERVICE.
Back to JASC 3810