JASC 3810

Service difficulty reports · 418

Reports filed under 3810 · Potable Water System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3810'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CA050125004Line · burst(CAN) IT WAS OBSERVED BY THE FLIGHT ATTENDANTS THAT A WATER LEAK WAS FOUND COMING FROM THE FWD GALLEY AREA. THE MANUAL SHUT-OFF VALVE WAS CLOSED BUT THE LEAK WAS STILL OBSERVED. THE AIRCRAFT RETURNED TO THE GATE AND A WATER LINE UNDER THE FWD GALLEY HAD BURSJan 23, 2005 · Fokker F28MK0100SDR CA041231002Line · burst(CAN) AFTER TAKE OFF, COULD NOT GET AIRCRAFT TO PRESSURIZE. AIRCRAFT LANDED BACK TO DEPARTURE AIRPORT. MAINTENANCE FOUND BOTH PRIMARY AND SECONDARY OUTFLOW VALVES AND OUTFLOW VALVE DRAIN LINE CONTAMINATED WITH ICE. WATER CAME FROM POTABLE WATER SYSTEM. A Dec 30, 2004 · Fokker F28MK0100SDR DL757041149Element · burnedFIRST CLASS LAV HOT WATER HEATER HAS A BURNED ELEMENT. REPLACED SAME.Dec 29, 2004 · N660DL · Boeing 757232SDR CA041207005Line · leaking(CAN) DURING CLIMB, CANNOT PRESSURIZE ACRFT. ACRFT RETURNED TO DEPARTURE AIRPORT. MX FOUND CABIN AIR FILTER FOR OUTFLOW VALVES FULLY ICE COVERED DUE TO POTABLE WATER TANK LINE LEAKING AND DRIPPING OVER FILTER. FILL WATER LINE FITTING AT THE TANK CONNECTION TDec 2, 2004 · Fokker F28MK0100SDR MWEA040213Service Panel · inoperativePOTABLE WATER SYSTEM STOPPED WORKING. FOUND POTABLE WATER SERVICE PANEL GUARD BENT AND FILL/DRAIN/VENT TURN-TO-LOCK CAP IN INCORRECT POSITION.Nov 21, 2004 · N601ME · Doug MD88SDR COMA0460434Water Heater · odorFLIGHT 5126 F/A REPORTS ELECTRIC SMELL IN GALLEY AREA. SMELL DISPATCHED WITH POWER OFF. DEACTIVATED AND DEFERRED GALLEY PER MEL.Jul 30, 2004 · N804CA · Cndair CL6002B19SDR 2004UALA00302Potable Water · failedPOTABLE WATER IS NOT WORKING AND LAVS STARTING TO BACK UP. ONE HOUR OUT OF LHR WATER PRESSURE WENT TO NO PRESSURE. FOUND AIR COMPRESSOR HAD FAILED. WITH ENGINES/APU RUNNING, BLEED AIR SHOULD HAVE BEEN THE ONE PRESSURIZING THE SYSTEM. THE APU BLEED AIR CHEApr 1, 2004 · N785UA · Boeing 777222SDR DL777040217Valve · failedCREW REPORTS LOSS OF WATER PRESSURE IN CABIN, DIVERTING TO JFK FOR REPAIRS. INSPECTED ALL WATER AND AIR PRESSURE LINES AT WATER TANKS AND VERIFIED ALL VALVES CLOSED. NO LEAKS. CKD AIR COMP AND VERIFIED GOOD AIR PRESS. FOUND AIR COMP CHECK VALVE STUCK OPEN Mar 5, 2004 · N877DA · Boeing 777232SDR 373PA0025Drain Mast · corrodedDRAIN MAST HAS HOLE CORRODED THROUGH SIDE ON BOTH SIDES OF MAST. REPLACED DRAIN MAST PER MM 38-31-21.Feb 2, 2004 · N373PA · Boeing 7373Y0SDR DL76L040125Compressor · overheatedELECTRICAL FUMES STRONG IN AFT GALLEY AREA DURING PREFLIGHT. FOUND POTABLE WATER COMPRESSOR SMOKING. REPLACED COMPRESSOR MM, OPS CHECK AND LEAK CHECK GOOD. VERIFIED PRESSURE SWITCH OPS NORMAL.Feb 1, 2004 · N185DN · Boeing 767332SDR DL777040079Valve · unserviceableINFLIGHT PROGRESSIVE FAILURE OF ONBOARD POTABLE WATER SYSTEM TO INCLUDE LOSS OF PRESSURE AND WATER FLOW IN ALL GALLEYS AND LAVATORIES EXCEPT AFT GALLEY AND 4 L/R LAVS. RESERVICED WATER SYSTEM. MANUALLY PLACED PRESELECT OVERFLOW VALVE IN THE OPEN POSITION FORJan 24, 2004 · N861DA · Boeing 777232SDR CA040119003Water Heater · failed(CAN) BURNING ELECTRICAL ODOR NOTICED IN LAVATORY D. WHEN ODOR BECAME STRONGER, FLIGHT DIVERTED, DECLARING AN EMERGENCY, FOUND TO BE THE WATER HEATER AT FAULT HEATER DE-ACTIVATED, UNDER MEL.Jan 17, 2004 · Airbus A319114SDR DL757031106Water Heater · overheatedFLIGHT ATTENDANT REPORTED, SMOKE, HAZE AND HEAT FROM 1ST CLASS LAV. FOUND WATER HEATER OVERHEATING AND SMELL OF BURNING PLASTIC. REPLACED HEATER.Dec 18, 2003 · N900PC · Boeing 75726DSDR AUS20031211Water Heater · faulty(AUS) AFT GALLEY NR 1 WATER BOILER FAULTY.Nov 23, 2003 · Boeing 767238SDR 0320046302Compressor · malfunctionedDURING CRUISE, AN ELECTRICAL BURNING SMELL EMITTED IN THE CABIN AND FLIGHT DECK. TURNED OFF CABIN VIDEO AND FOLLOWED COM PROCEDURES FOR ELECTRICAL SMOKE AND REMOVED POWER TO THE RECIRCULATION AND GASPER FANS. SMELL DISSIPATED AND AIRCRAFT CONTINUED TO DESTINNov 14, 2003 · N662US · Boeing 747451SDR DL777030808Valve · failedAFTER TAKEOFF NO WATER PRESSURE IN GALLEYS OR LAVS. FOUND PRESELECT OVERFLOW VALVE FAILED AND REPLACED SAME.Aug 24, 2003 · N866DA · Boeing 777232SDR MEX2003314Line · brokenDURING TRANSIT CHECK WAS DETECTED POTABLE WATER LEAK, DRAINING TO THE ELECTRIC/ELECTRONIC COMPARTMENT. TCAS AND FDAU WERE WET. AIRCRAFT WAS SENT TO THE HANGAR. DURING REVISION WAS DETECTED NIPPLE AND SUPPLY LINE BROKEN THE 218 STATION. THE NIPPLE AND SUPPLJul 27, 2003 · N754RA · Doug DC987SDR CA030113011Compressor · malfunctioned(CAN) STRONG BURNING ODOR AND LIGHT SMOKE IN AFT CABIN. FAULT TRACED TO POTABLE WATER COMPRESSOR. CB FOUND POPPED. DEFERRED FOR REPLACEMENT. ELECTRICAL CONNECTOR REMOVED FROM COMPRESSOR.Jan 11, 2003 · Boeing 757251SDR AUS20021336Cooler · blocked(AUS) R5 TOILET WATER COOLER OVERHEATED DUE TO AIRFLOW BLOCKAGE.Nov 19, 2002 · Boeing 747438SDR USA2002F00073Water Heater · overheatedENROUTE, FLIGHT ATTENDANT REPORTED A SLIGHT ELECTRICAL ODOR IN THE AFT GALLEY AREA THAT TENDED TO BE INTERMITTENT. ODOR DISSIPATED DURING FLIGHT. FLIGHT CONTINUED AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE CHECKED THE AFT GALLEY AREA INCLUDING CONNECTJul 19, 2002 · N525AU · Boeing 7373B7SDR C2XA01TY192Line · corrodedTYS During a scheduled inspection the pottable water line was found corroded at the fuselage to tube fitting. Maintenance removed and replaced the potable water overflow line I.A.W.-EMB-135-AMM-38-10-07. Repairs where satisfactory and the aircraft will be relDec 12, 2001 · N27512 · Emb EMB135ERSDR DL76G011812Rod · shearedON TAKEOFF FROM FRA HEARD BANGING SOUND, THERE AFTER LOST ALL POTABLE WATER. FOUND 2 TIE RODS SHEARED AND MAIN WATER TANK LEAKING AT LOWER FITTING AND FIBERGLASS SURROUND. DRAINED WATER TANK AND SECURED TANK WITH CARGO STRAP, WATER COMPRESSOR C/B ON P33 PNL Nov 15, 2001 · N153DL · Boeing 7673P6SDR COMA0160896Tank · shortedFLIGHT #5819 - F/A REPORTED SMOKE SMELL. GALLEY AND LAV WATER SERVICE INOP. GALLEY BREAKERS WERE TRIPPED.REPLACED THE GALLEY WATER TANK.Oct 28, 2001 · N995CA · Cndair CL6002B19SDR AUS20011063Compressor · faulty(AUS) POTABLE WATER COMPRESSOR LOCATED IN AFT CARGO BULK HOLD FAULTY. INVESTIGATION FOUND THE COMPRESSOR MOTOR BEARINGS SEIZED.Oct 9, 2001 · Boeing 767338SDR USAAF01049Timer · malfunctionedSTL-PIT - FLT 9281 - SLIGHT FUMES WERE NOTICED COMING FROM BOTH LAVATORIES, AND SMOKE DETECTORS ACTIVATED FOR A BRIEF TIME DURING CRUISE FLIGHT. FLIGHT LANDED IN PIT WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED LEFT AND RIGHT LAVATORY FAUCET TIMERS. LEAK Jul 17, 2001 · N897US · Fokker F28MK0100SDR DL73K010678Heater · faultyA/C DIVERTED TO CHS.SMOKE /ELECTRICAL SMELL IN AFT LAV/GALLEY FOLLOWED POM. PULLED C/B SMELL DISIPATED. FOUND SOURCE TO BE AFT LAV WATER HEATERApr 26, 2001 · N316DL · Boeing 737232SDR DL777010019Compressor · overheatedA/C DIVERTED TO LGW DUE TO RUBBER SMELL IN AFT CABIN. FOUND POTABLE WATER COMPRESSOR OVERHEATED.Jan 5, 2001 · N866DA · Boeing 777232SDR AU001217Tank · ruptured(AUS) RT MAIN POTABLE WATER TANK SUPPORTING RODS (3OFF) BROKEN ALLOWING THE TANK TO COLLAPSE ONTO THE TOILET FAN AND RUPTURE.Oct 31, 2000 · Boeing 767338SDR AU001120Support Bracket · failed(AUS) RT MAIN POTABLE WATER TANK SUPPORT RODS (3OFF) BROKEN ALLOWINGTHE TANK TO COLLAPSE ONTO THE TOILET FAN AND RUPTURE.Oct 31, 2000 · Boeing 767338SDR ASAA0010156Heater · overheatedANC - DURING MAINTENANCE CHECK, NOTICED SMOKE AND ELECTRICAL BURNING SMELL IN AFT CABIN. FOUND WIRING FOR POTABLE WATER HEATER JUST ABOVE TANK OVERHEATED. REINSTALLED HEAT TAPES PER EO 1-38-10-01E AND CONNECTED HEAT TAPE WIRING TO AIRCRAFT PER EO 1-38-10-01 Oct 29, 2000 · N740AS · Boeing 737290CSDR 2000UALA00157Compressor · failedHOT ELECTRICAL ODOR SMELLED IN COCKPIT AND FRONT OF FIRST CLASS AREA. *S/D* POTABLE WATER SYSTEM AIR COMPRESSOR WAS FOUND TO HAVE BEEN OVERHEATING AND SMOKING. SHOP FINDINGS FOUND WATER IN COMPRESSOR. REPLACED AIR COMPRESSOR AND UNLOADER CHECK VALVE.Mar 27, 2000 · N117UA · Boeing 747422SDR USAASB00065Valve · closedRDU - FLT 1487 - EN ROUTE FROM PHL-RSW, APPROXIMATELY 35 MINUTES INTO FLIGHT, FLIGHT ATTENDANTS NOTIFIED CAPTAIN OF A STRONG BURNING ODOR IN THE REAR GALLEY AREA. CAPTAIN WENT BACK TO THE REAR OF THE AIRCRAFT, CONFIRMED THE ODOR AND PROCEEDED TO PULL ALL CIRCMar 6, 2000 · N426US · Boeing 7374B7SDR AU000171Heater · failed(AUS) GALLEY POTABLE WATER RESERVOIR CUFF HEATER FAILED.Feb 23, 2000 · Cndair CL6002B19SDR 99UAL900607Valve · malfunctionedDIVERTED TO MCI DUE TO VIBRATION IN AFT GALLEY AREA. *S/D* POTABLE WATER FILL/SHUTOFF VALVE WAS FOUND OPEN, CAUSING PRESSURE TO VENT AND MAKE WATER LINE VIBRATE. VALVE WAS MOVED TO CLOSED POSITION AND VIBRATION WENT AWAY.Nov 21, 1999 · N521UA · Boeing 757222SDR AU990967Heating Element · worn(AUS) POTABLE WATER LEVEL SENSOR HEATER RIBBON ELEMENT LOCATED IN THE AFT END OF THE FORWARD CARGO HOLD WAS FOUND TO BE SMOULDERING. INVESTIGATION FOUND CHAFING OF THE RIBBON ELEMENT WIRING.Aug 17, 1999 · Boeing 747438SDR DL73K991611Valve · leakingPOTABLE WATER SCV VALVE LEAKING IN THE CLOSED POSITION WHEN A/C IS PRESSURIZED. SUSPECTED OF CAUSING ICE BALL THAT DAMAGED HORZ STAB. REPLACED THE VALVE AND L/E OF THE HORIZONTAL STAB.Jul 18, 1999 · N322DL · Boeing 737232SDR DLM11991605Drain Valve · leakingPOTABLE WATER SUPPLY DECREASE FROM FULL TO EMPTY IN 4 HOURS. FOUND RT ELECT DRAIN VALVE LEAKING INTERNALLY. CAPPED LINE AND VALVE. CLEARED WATER AND ICE OUT OF AFT STAB COMP, DEFERRED REPLACEMENT OF VALVE.Jul 17, 1999 · N807DE · Doug MD11SDR 99UAL900291Valve · not closedDIVERTED TO DEN DUE TO ABNORMAL NOISE UNDER AFT GALLEY. *S/D* THIS IS THE FIRST HIT FOR THIS TYPE OF PROBLEM ON THIS AIRCRAFT. MAINTENANCE FOUND THAT THE POTABLE WATER FILL VALVE WAS PARTIALLY OPEN, VENTING AIR PRESSURE OVERBOARD. NO OTHER DESCREPANCIES WEMay 23, 1999 · N515UA · Boeing 757222SDR DL757990885Water Heater · inopFLT ATTENDANT CALLED AFTER T/O BNA AND REPORTED SMOKE SMELL IN AFTCABIN. FLT CREW REPORTED SMELL DISIPATED BEFORE LANDING. CONTRACT MTC CHECKED AFT GALLEY COFFEE MAKERS AND OVENS, NO TROUBLE FOUND. FOUND RT AFT LAV WATER HEATER INOP. REPLACED SAME.Apr 23, 1999 · N660DL · Boeing 757232SDR 99ZZZX1471Drain Mast · failedPILOT REPORTED AFT SINKS (GALLEY AND LAV) WOULD NOT DRAIN. T/S SYSTEM, FOUND DRAIN MAST NOT HEATING UP. REMOVED MAST AND INSTALLED NEW MAST OF SAME P/N, S/N 396. PERFORMED OPERATIONAL CHECK OF DRAIN MAST HEATING ELEMENT, NO DEFECTS NOTED. SINKS WERE NOT DRAIMar 8, 1999 · N475QS · Gulstm GIVSDR 98UAL900598Valve · malfunctionedON DESCENT AT 19000 FEET HEARD A LOUD BANG. *S/D* AFTER INSPECTION A DENT WAS FOUND ON THE NR 1 RT SLAT DUE TO THE BUILD UP OF ICE ON THE POTABLE WATER SYSTEM DRAIN PORT. REPLACED DRAIN VALVE AND TESTED SYSTEM FOR LEAKS. CONFIRMED CONFIGURATION AND PERFORMDec 5, 1998 · N1853U · Doug DC1030SDR 98ZZZX4187Water Tank · leakingTANK SPLITS OPEN AND LEAKS WATER INTO BELLY OF AIRCRAFT. FAILURES OCCUR ON END CAPS AND APPEAR TO BE DUE TO OBVIOUS MANUFACTURING DEFECTS. THIS IS THE THIRD FAILURE OPERATOR HAS EXPERIENCED.Aug 7, 1998 · N435T · Amd FALCON2000SDR ARWA980412Fill Port · corrodedDURING D-CHECK, FOUND FUSELAGE EXT RIGHT FOWARD, WATER FILL PORT, CORROSION INSIDE. REMOVED CORROSION, FABRICATED FILLER AND DOUBLER AND INSTALLED IN ACCORDANCE WITH DOUGLAS AIRCRAFT COMPANY, SRM 53-2-1. WORK ACCOMPLISHED UNDER ARROW AIR FORM JW3B, WORK ORDEApr 24, 1998 · N791AL · Doug DC862SDR P5CA9800854Panel · delaminatedDELAMINATED POTABLE WATER SERVICE PANEL. REPAIRED PER BOEING SRM 51-40-12 FIG 9.Apr 22, 1998 · N851FT · Boeing 747122SDR VJ9800138Water Heater · corrodedTOP OF FRESH WATER TANK UNDER FORWARD LAV SINK CORRODED. REPLACED TANK IAW DC9 MM 38-11-4. LEAK AND OPS CHECKED GOOD IAW DC9 MM 38-11-4.Apr 4, 1998 · N905VJ · Doug DC932SDR P5CA9800499Panel · delaminatedWATER SERVICE PANEL DELAMINATED. REPAIRED PER BOEING SRM 51-40-09.Mar 10, 1998 · N854FT · Boeing 747122SDR AU980218Compressor · overheated(AUS) POTABLE WATER COMPRESSOR OVERHEATED. SUSPECT COMPRESSOR WAS OPERATING CONTINUOUSLY AND DID NOT CUT OFF.Feb 23, 1998 · Boeing 737376SDR 98UAL900063Handle · not closedNO WATER PRESSURE AND LOUD NOISE FROM REAR OF AIRCRAFT. RETURNED TO FIELD. *S/D* THE POTABLE WATER SERVICE FILL VALVE HANDLE HAD BEEN LEFT IN THE OPEN POSITION DURING SERVICING. POTABLE WATER SERVICE FILL HANDLE WAS CLOSED. NO DEFECTS WERE FOUND.Feb 14, 1998 · N584UA · Boeing 757222SDR P5CA9701305Fill Valve · corrodedLEVEL 1 CORROSION, LWR SURFACE STA 970 WATER SERVICE STATION WATER TANK FILL VALVE HANDLE AT MOUNT. CORROSION REMOVED FOUND TO BE WITHIN LIMITS IAW BOEING SRM 53-10-01 FIG 1, REG MAT .130 NOW .111 TREATED AND PRIMED PER SRM 51-10-06.Jul 24, 1997 · N851FT · Boeing 747122SDR 97UAL900403Air Compressor · failedELECTRICAL BURNING SMELL THROUGH OUT CABIN. *S/D* FOUND WATER COMPRESSOR CB POPPED AND WOULD NOT RESET. INSPECTED ALL CABIN LIGHTING AND ELECTRICAL SYSTEMS AND NO FAULTS WERE NOTED. REPLACED THE AIR COMPRESSOR FOR THE WATER SYSTEM.May 27, 1997 · N7256U · Boeing 727222
Back to JASC 3810