JASC 3810

Service difficulty reports · 418

Reports filed under 3810 · Potable Water System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3810'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2010010400028Water Heater · overheatedFWD AFT LAV SMOKE DETECTOR WENT OFF (REPEAT). HOT IRON TYPE ODOR EMANATING FROM THAT LAV. UPDATE-CREW TURNED OFF WATER HEATER AND RAN ALL HOT WATER OUT OF HEATER. ODOR HAS NOW DISSIPATED. NO SMOKE WAS SEEN. SMOKE DETECTOR OK. WATER HEATER OVERHEATING. ITJan 2, 2010 · N564UA · Boeing 757222SDR UALA2009121103830Toilet · fullDUE TO WATER LEAK FROM AFT LAV,CARPET IN AFT SECTION OF LAST ROW NEEDS TO BE CLEANED. FOUND TOILET BOWL FULL OF WATER, REMOVED WATER & CLEANED UP AFT LAV. SHUT OFF WATER VALVE & REMOVED AFT PANEL IN AFT PIT NO LEAK FOUND. RPL'D PANEL. ACTIVATED WATER SYS. REDec 8, 2009 · N422UA · Airbus A320232SDR USAA2009113093238Water Heater · faultyFLT 337 - PHX - SJD - BURNING SMELL - FLIGHT ATTENDANT REPORTS BURNING SMELL ON DESCENT. SMELL COMING FROM FORWARD LAV / GALLEY AREA SMELLING LIKE BURNING RUBBER. REMOVED AND REPLACED WATER HEATER AT FORWARD LAV PER AMM 38-10-01A.Nov 29, 2009 · N805AW · Airbus A319132SDR UALA2009100503100Handle · out of positionNO WATER PRESSURE IN ALL LAVS & ALL GALLEYS, FLIGHT DIVERTED. CHECKED WATER PANELS AND SERVICED WATER SYSTEM, NO HELP. AFTER LAV SERVICING ALL WATER PRESSURE HANDLE MUST NOT HAVE BEEN IN FULL CLOSE ON LAV SVC PANEL. OPS CHECK GOOD.Oct 2, 2009 · N780UA · Boeing 777222SDR AALA20090918DEN01Water Heater · overheatedINFLIGHT ORD TO SNA. CREW REPORTED FUMES AROUND RIGHT AFT LAVATORY AREA AND SMOKE DETECTOR SOUNDED. MAINTENANCE FOUND RIGHT AFT LAV WATER HEATER OVERHEATED AND CIRCUIT BREAKER POPPED. LANDED DEN WITHOUT INCIDENT. RESET RIGHT AFT LAVATORY WATER HEATER. NO Sep 17, 2009 · N604AA · Boeing 757223SDR UALA2009090802798Potable Water · emptyNO WATER QUANTITY AND PRESSURE, RTFL. SHORTLY AFTER DEPARTURE, CREW NOTIFIED CHIDD AND SAM THAT THE POTABLE WATER SYSTEM APPEARED TO BE EMPTY. MAINT CONFIRMED NO WATER IN MID LAVS-GALLEYS AND AFT LAVS-GALLEYS. WATER QTY IND RESERVICED WATER AND BLED SYSTEM. Sep 6, 2009 · N644UA · Boeing 767322SDR AMCR200903Petcock · leakingWHILE CREW WAS READYING THE ACFT FOR DEPARTURE, APU AIR WAS SELECTED ON AND COFFEE MAKER'S WATER FILLER SPIGOT STARTED RUNNING AND OVERFILLING THE COFFEE POT. WATER STARTED RUNNING ONTO FLOOR BEFORE SYS WAS SHUTDOWN. THE SPIGOT HAS A SPRING LOADED PUSHBUTTON WJul 20, 2009 · N525AC · Gulstm GULFSTREAMGVSDR CA090630002Line · leaking(CAN) THIS IS THE POTABLE WATER HEATED SUPPLY LINE. LINE WAS LEAKING AND DURING REPLACEMENT MX NOTED SEVERAL HOLES IN LINE SUSPECTED TO HAVE BEEN CAUSED BY ELECTRICAL ARCING OF THE HEAT TAPE.Jun 29, 2009 · Boeing 767223SDR UALA2009061501710Drain Line · leakingWATER LEAK. FLIGHT DIVERTED. FWD GALLEY DRAIN CLOGGED. DRAINING ONTO GALLEY FLOOR. CLEARED OBSTRUCTION AND WORKS NORMAL.Jun 14, 2009 · N843UA · Airbus A319131SDR DL76L090658Drain Mast · damagedFOA - FOUND AFT DRAIN MAST DAMAGED AND WITH ONE ATTACHMENT BOLT SHEARED AND THE REMAINING TWO WITH DAMAGED INSERTS DUE TO LATERAL IMPACT. REMOVED AND REPLACED DRAINMAST.Apr 8, 2009 · N1201P · Boeing 767332SDR AALA2009031400003Water Heater · malfunctionedDUB - SMOKE DETECTOR IN LAVATORY 2 WENT OFF. NO VISIBLE SMOKE. NO FAULT ON SMOKE DETECTOR. FOUND LAVATORY WATER HEATER INOPERATIVE. REPLACED WATER HEATER. SYSTEM GROUND CHECK NORMAL OPERATION.Mar 14, 2009 · N361AA · Boeing 767323SDR UALA2008121506865Valve · unstableWATER PRESSURE FAILURE. FLIGHT DIVERTED. DEFERRED DUE TIME, PRESELECT FILL VALVE FOUND SOLID, MECHANICAL LINKAGE WILL NOT MAKE SOLENOID. TRIED TO REWORK NO HELP. PREVIOUS HISTORY AND CHRONIC ITEM. REPLACED PRESELECT OVERFLOW VALVE. WATER SYSTEM SERVICEABDec 12, 2008 · N777UA · Boeing 777222SDR DL76L081700Compressor · odorPOTABLE WATER COMPRESSOR INOP AND EMITTING ELEC SMELL. FOUND COMPRESSOR WITH BURNT SMELL. DISCONNECTED AND STOWED CONNECTOR. PULLED/SECURED C/B H6 ON P33. FWD TO MCO PLAC REF MEL 38-10-01A SMELL OCCURRED AT GATE WITH PAX ONBOARD. REMOVED AND REPLACED POTADec 7, 2008 · N192DN · Boeing 767332SDR UALA2008112106604Valve · malfunctionedNO WATER PRESSURE THROUGHOUT ACFT. FLIGHT DIVERTED. REPLACED PRESELECT OVERFLOW (V38102) ON ACCOUNT NOT FULLY CLOSING. WATER SYS PRESS CHECKS NORMAL.Nov 18, 2008 · N777UA · Boeing 777222SDR VJ1R20081118001Water Heater · overtempACFT AT CRUISING ALTITUDE WHEN A PASSENGER ADVISED THE CREW THAT THEY COULD ODOR SOMETHING BURNING IN THE CABIN AREA. THE CREW DECLARED AN EMERGENCY AND DIVERTED. AFTER LANDING, THE PROBLEM WAS DETERMINED TO BE THE LAVATORY WATER HEATER HAD OVER HEATED CAUSINGNov 7, 2008 · Cndair CL6002B16SDR 2008UALA03117Valve · openVIBRATION IN THE AFT CABIN FLOOR LED TO DIVERSION. WATER FILL VALVE AND PANEL LEFT OPEN SUSPECT ALL ISSUES ARE RELATED TO WATER FILL VENT VALVE NOT BEING CLOSED, BLEEDING HEAD PRESSURE. CAUSING WATER COMPRESSOR TO VIBRATE FLOOR AND CLUNKING WATER LINE DUE TOJun 1, 2008 · N540UA · Boeing 757222SDR MASA200800420Line · leakingASH FLT 7290 ROA-IAD. CREW REPORTED AN ELECTRICAL ODOR AND WATER LEAKING AT THE FWD POTABLE DRAIN AND THE AVIONICS DOOR. REPLACED SUCTION LINE.May 25, 2008 · N570ML · Cndair CL6002B19SDR 2008UALA02847Valve · openPOTABLE WATER INDICATION CAUSED FLIGHT DIVERSION. SUPPLEMENTAL DATA UPDATE CAUSE, LAV DRAIN VALVE IN LAV 2L WAS OPEN. CLOSED DRAIN VALVE IN LAV 2L, SERVICED LAVS, NO LEAKS NOTED.May 18, 2008 · N515UA · Boeing 757222SDR 2008UALA02707Compressor · failedAIR COMPRESSOR MOTOR BURNED UP AT DEPT, INITIAL CALL WAS FOR SMOKE ODOR IN AFT GALLEY. SUSPECT FAULTY BEARING. REPLACED AIR COMPRESSOR PER AMM 38-42-01. POTABLE WATER SYSTEM OPS CHECK GOOD. AC OK FOR SERVICE.May 12, 2008 · N798UA · Boeing 777222SDR CA080305004Coupler · cracked(CAN) DURING CRUISE, CREW NOTED CABIN ALTITUDE WARNING. UNABLE TO CLOSE OUTFLOW VALVE EITHER ELECTRICALLY OR MANUALLY. EMERGENCY DESCENT PERFORMED, OXYGEN MASKS DROPPED. OUTFLOW VALVE WOULD CLOSE TO THE .2500 POSITION ON GAUGE. ATTEMPTED TO CLOSE VALVE MANUALLFeb 21, 2008 · Boeing 7378Q8SDR AALA200800208Water Heater · inoperativeGJT INFLIGHT T119/30JAN EWR TO LAX CREW REPORTED SMOKE IN CABIN. SMOKE DETECTORS IN LAVATORIES WENT OFF. LANDED GJT WITHOUT INCIDENT. REPLACED MID LAVATORY WATER HEATER. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 30, 2008 · N614AA · Boeing 757223SDR 200801233Fitting · crackedFLIGHT 7702 DEN TO YYZ ON DESCENT THE AUTO PILOT KICKED OFF AND THE AIRCRAFT WAS HARD TO TURN. THE AILERONS FELT AS IF THEY WERE STUCK AND WERE GETTING PROGRESSIVELY WORSE. PILOT DECLARED AND EMERGENCY AND LANDED WITHOUT INCIDENT. MAINTENANCE LOCATED A POTAJan 21, 2008 · N654RW · Emb ERJ170100SESDR ZZDA2008035Line · leakingSMOKE AND ACID SMELL IN COCKPIT. PUFF AND ELECTRICAL SMELL GALLEY AREA IE COFFEE POTS REPORTED BY A FLIGHT ATTENDANT. FOUND WATER LEAK IN GALLEY DRIPPING ON NR 3 COFFEEMAKER CONNECTOR CAUSING A SHORT AND SMALL AMOUNT OF SMOKE. REPLACED WATER SUPPLY LINE. RJan 20, 2008 · N965AT · Boeing 717200SDR 2008UALA00108Pressure Switch · failedLOST POTABLE WATER SYSTEM PRESSURE. REPLACED S251 PRESSURE SWITCH AND RPL INLINE FILTER.Jan 7, 2008 · N104UA · Boeing 747422SDR 2007UALA05211O-Ring · failedFLT DIVERTED DUE TO A FAILED WATER SYSTEM. CREW CONCERNED WATER LEAKING INTO CARGO COMPARTMENT WOULD FREEZE. REPLACED WATER LINE O-RING, DRAINED WATER FROM BELLY AND REACTIVATED WATER SYSTEM. WATER SYSTEM REMAINS FULL. OPS CHECK NORMALLY. REF AMM 38-00-00Dec 22, 2007 · N792UA · Boeing 777222SDR 2007UALA05126Valve · openFLIGHT DIVERTED DUE TO LOSS OF WATER PRESSURE AND VIBRATION ISSUES. WATER FILL VALVE WAS LEFT IN OPEN POSITION CAUSING BOTH WATER LOSS AND AFT AIRFRAME VIBRATION. SERVICED WATER SYSTEM AND CLOSED VALVE.Dec 16, 2007 · N87UA · Boeing 757222SDR 2007UALA04321Toilet · leakingRTFL DUE TO WATER LEAK FROM THE GALLEY, SOAKING THE CREW REST AREA / PASSENGER SECTION. SUSPECT TOILET ASSEMBLY. REMOVED AND REPLACED THREE TOILET ASSEMBILES AT LAV 101, 131,141. REPLACED AFT DRAIN RESTRICTOR VALVE. OPS CHECK GOOD.Oct 21, 2007 · N227UA · Boeing 777222SDR 2007FA0000816Socket · burnedTHE SOCKET ON ONE OF THE (2) LAMPS BURNED CAUSING AN ELECTRICAL ODOR IN THE BAG BIN WHERE THE STERILIZER IS LOCATED. THE 2 AMP CIRCUIT BREAKER WHICH CONTROLS THE POWER TO THE STERILIZER DID NOT POP.Sep 17, 2007 · N23M · Gulstm GULFSTREAMGVSDR BKE2007F00000Drain Line · crackedWHILE FLYING AT FLIGHT LEVEL 370, THE PILOTS WERE NOT ABLE TO MOVE THE AILERON CONTROLS. THE AIRCRAFT DESCENDED TO A LOWER ALTITUDE AND THE AILERON CONTROLS FUNCTIONED NORMALLY. THE AIRCRAFT UPON RETURN TO HOME BASE WAS INSPECTED. IT WAS DETERMINED THAT WATSep 14, 2007 · N322AD · Gulstm 200SDR HALA0700279Compressor · overheatedF/A REPORTED SMELLING AN ELECTRICAL ODOR IN THE AFT RIGHT CABIN LAST 5 ROWS ON THE RIGHT SIDE, ALL GALLEY EQUIPMENT WAS OFF. INSP CABIN AREA AROUND SEATS 39-43 H/J INCLUDING UNDER SEATS, OVERHEAD BINS, AFT GALLEY AND AFT LAVS CHECKED FWD, AFT AND BULK CARGO CJul 8, 2007 · N582HA · Boeing 76733ASDR DL76L070768Compressor · odorFLIGHT ATTENDANT REPORTS BURNING ODOR IN AFT GALLEY. FWD TO MCO AND PLACARD PER MEL M38-10-01A. T/S SUSPECT WATER COMPRESSOR. DISCONNECTED COMPRESSOR C/P AND FWD TO MCO PER MEL 38-10-01A. REPLACED WATER COMP PER IPC 38-15-01-03 ITEM 380 OPERATIONAL CK OK.Jun 21, 2007 · N180DN · Boeing 767332SDR CA070418001Potable Water · leaking(CAN) FOLLOWING THE ADVISORY WIRE FROM MFG, THE WATER SYSTEM VENT VALVES (6) WHERE REPLACED IN MFG. ON THE NEXT CUSTOMER FLIGHT, ONE VENT VALVE FROM THE GALLEY HAS STARTED TO LEAK. END RESULT, AVIONICS BAY FLOODED, BLACK BOXES FULL OF WATER. INVESTIGATION SHOWApr 16, 2007 · Bombdr BD7001A10SDR CA070725002Drain Valve · damaged(CAN) THE AIRCRAFT POTABLE WATER SYSTEM WAS DAMAGED DUE TO HAVING THE WATER SYSTEM FULL OF WATER. THEN PARKING THE AIRCRAFT ON THE RAMP FOR 8 HRS AT -14 DEGREES C. WITH NO ADDITIONAL HEAT TO KEEP THE WATER SYSTEM FROM FREEZING. UPON ARRIVING, THE PILOTS REPORMar 22, 2007 · Amd FALCON2000SDR CA070327002Drain Valve · damaged(CAN) THE AIRCRAFT POTABLE WATER SYSTEM WAS DAMAGED DUE TO HAVING THE WATER SYSTEM FULL OF WATER. THEN HAVING THE AIRCRAFT LEFT ON THE RAMP FOR 8 HOURS AT -14C WITH NO ADDITIONAL HEAT TO KEEP THE WATER SYSTEM FROM FREEZING. UPON ARRIVAL THE PILOTS REPORTED (WAMar 22, 2007 · Amd FALCON2000SDR CA070312004Line · failed(CAN) DURING NORMAL WALK AROUND FOUND WATER LEAKING OUT OF THE BELLY OF THE AIRCRAFT, FORWARD AREA. SUBSEQUENT INVESTIGATION FOUND CLAMSHELL (CLAMP) P/N CA62505-56BL HOLDING POTABLE WATER LINE THAT RUNS OVER FWD. E&E COMPARTMENT TOWARD THE FWD. LAVATORY FAILEDMar 7, 2007 · Boeing 767306SDR 2007UALA00689Outflow Valve · stuckFLIGHT DIVERTED DUE TO NO WATER PRESSURE. PRE-SELECT OVERFLOW VALVE FOUND TO STICK IN SEMI-CLOSED POSITION. PRIOR TO REPLACEMENT- CHECKED LINKAGES, INDICATION & VALVE OPERATION. VLV OPERATION NORMAL WITH PRE-SELECT KNOB MOVEMENT AT FWD SERVICE PANEL. PRECAMar 6, 2007 · N213UA · Boeing 777222SDR 2007UALA00390Water System · low pressureFLT DIVERTED DUE TO NO WATER PRESSURE IN ENTIRE ACFT. PERFORMED OPS CHECK OF WATER SYS ALSO OPS CHECK PRESELECT WATER VALVE ABOVE CEILING PANEL IN FIRST CLASS, ALSO CHK DRAIN VALVE, PRESURE CHECK WITH AND WITHOUT APU BLEED, ALSO REFILLED WATER TO FULL. UNABLFeb 11, 2007 · N213UA · Boeing 777222SDR COMA0770015Valve · leakingFLIGHT 5328 - EN ROUTE CVG-PBI DISCOVERED THE FORWARD AND AFT LAVATORY WERE LEAKING POTABLE WATER INTO THE CABIN, FLIGHT RETURNED TO CVG. REPLACED THE FORWARD LAVATORY FAUCET.Feb 9, 2007 · N369CA · Cndair CL6002C10SDR CA070129003Valve · open(CAN) OVER AN HOUR INTO THE FLIGHT, A SPOILER MOMENTARY DEPLOYMENT WITH WING ROLL AFTER SPOILER FAULT CAS OCCURRED. FLIGHT SPOILER FAIL CAS POSTED SHORTLY AFTERWARDS. SEVERAL CABIN SYSTEM MALFUNCTIONS OCCURRING NEXT FOLLOWED BY HAVING NO WATER FROM ANY FAUCEJan 22, 2007 · Bombdr BD7001A10SDR ASMF200701001Line · leakingDURING PUSH BACK, A WATER LEAK WAS DETECTED ON ELECTRICAL/ELECTRONIC COMPARTMENT AT COMPUTERS AREA. AIRCRAFT WAS SENT TO HANGAR AND DURING MAINTENANCE CHECK, A WATER LINE WAS DETECTED LEAKING ON FORWARD CARGO COMPARTMENT. THE LINE P/N H151-615 WAS REPLACED IAJan 4, 2007 · N161PL · Doug MD88SDR DL76G060609Unknown · cloggedWATER DRAINING INTO AFT GALLEY FROM 2 VENTS BELOW THE AFT LAV CLEARED CLOG. WATER DRAINS NORMAL ETOPS CATEGORY (B): DIVERSION OR TURNBACK.Jul 24, 2006 · N1611B · Boeing 767332SDR SB06004Line · burstALB - FLT 720 - ON APPROACH TO DCA, FROM ALB, CREW REPORTED A WATER SUPPLY LINE ABOVE THE COCKPIT DOOR HAD BURST RESULTING IN WATER BEING SPRAYED ALL OVER THE COCKPIT. FLIGHT LANDED WITHOUT INCIDENT AT DCA. NO EMERGENCY WAS DECLARED. MAINTENANCE REMOVED ANDJan 16, 2006 · N424US · Boeing 737401SDR AWXA200501521Compressor · odorPHX - AIR TURN BACK - FLT 0542 - CREW REPORTED THAT DURING CLIMBING OUT AT 7000 FT, FLIGHT ATTENDANTS REPORTED A BURNING ELECTRICAL SMELL THROUGHOUT CABIN. CREW ACCOMPLISHED ODOR REMOVAL CHECKLIST AND RETURNED TO PHX, LANDING WITHOUT FURTHER EVENT. MAINTENANDec 14, 2005 · N913AW · Boeing 757225SDR AU510002166Insulation · damagedHEATED POTABLE HOT WATER PIPE INSULATION AND ATTACHING CLAMPS HEAT DAMAGED. SUSPECT WATER IN PIPE IS NOT THERMOSTATICALLY CONTROLLED. PIPE SUPPLIES HOT WATER TO VIP SUITE. AIRCRAFT IS RAAF VIP.Dec 12, 2005 · Boeing 737*SDR AU510001505Compressor · overheatedFUMES IN CABIN PRIOR TO BOARDING. INVESTIGATION FOUND POTABLE WATER COMPRESSOR EXTREMELY HOT. INVESTIGATION FOUND THAT ON REMOVAL OF THE CAPS AND COVER BOTH STAGES HAD WATER IN BELLOWS AND VALVES. THE SECOND STATE (HIGH-PRESSURE) REED WAS FRACTURED AT THE OUDec 12, 2005 · Boeing 767338SDR MWEA050108Valve · out of positionNO WATER FROM ANY FAUCETS. FOUND VENT AND FILL VALVE IN HALF INCH POSITION ON SERVICE PANEL, MOVED VALVE TO OFF POSITION. SERVICED WATER AND VERIFIED PRESSURE.Oct 1, 2005 · N907ME · Boeing 717200SDR DLM88050303Compressor · failedAT FL 340 CRUISE FLIGHT COCKPIT DETECTED ELECTRICAL SMELL. REPLACED FAILED POTABLE WATER SYSTEM COMPRESSOR.Jun 2, 2005 · N950DL · Doug MD88SDR RYNA200500014Potable Water · leakingDURING CRUISE AT FL 28.0, EXPERIENCED MULTIPLE MALFUNCTIONS. AUTO-PILOT FAILED, PRESSURIZATION AUTO FAIL LIGHT ILLUMINATED, MACH TRIM FAIL LIGHT ILLUMINATED, ALTITUDE ALERTER FAILED, CAPTAIN'S IVSI FLAG IN VIEW, CAPTAIN'S ALTIMETER FLAG IN VIEW AND LAV SINK WApr 9, 2005 · N235US · Boeing 737201SDR DLM88050093Water Heater · overheatedAFT LEFT LAV HAD SMOKE / ELECT BURNING SMELL EMITTING FROM IT. REPLACED OVERHEATED WATER HEATER AND CONNECTOR.Feb 8, 2005 · N922DL · Doug MD88SDR DL764050089Line · failedAT FL320 APPROX 100 NME OF KSFO, COCKPIT FILLED UP WITH HAZE AND HOT SMOKEY SMELL. FLIGHT ATTENDANTS REPORTED RECEIVING ELECTRICAL SHOCKS FROM IFE ENTERTAINMENT SYSTEM. DECLARED EMERGENCY AND LANDED IN SFO. AFTER LANDING FOUND POTABLE WATER TANK EMPTY AND FFeb 6, 2005 · N842MH · Boeing 767432ER
Back to JASC 3810