JASC 3830
Service difficulty reports · 747
Reports filed under 3830 · Waste Disposal System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202306195816Generator · vibrationAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO CLT DUE TO AIRFRAME VIBRATION FROM 4R DOOR AND AFT GALLEY FLOOR. VIBRATION WAS MODERATE. 17000 FEET 300 KNOTS AND 250 KNOTS, VIBRATION PERSISTED. THE AIRCRAFT LANDED SAFELY AT CLT WISDR AALA202306143996Coupling · disconnectedAIRCRAFT WAS GROUNDED: LAVATORY L2A-1L, L3F-1, AND L3F-1LC DO NOT FLUSH. EMERGENCY DECLARED; FLIGHT RETURNED TO DFW LANDING SAFELY. MAINTENANCE FOUND DISCONNECTED COUPLING ON LAVATORY L2A-1L TOILET ASSEMBLY CAUSING LEFT HAND LAVATORIES TO NOT FLUSH. RECONNECTSDR DALA2023061204749Unknown · unknownSHIP 0193 -DIV- TO DUB DUE TO LAVATORIES INOP. CORRECTIVE ACTION: UPON ARRIVAL THE LAV TANKS WERE FOUND TO BE FULL. SERVICED AND OPS CHECKS NORMAL.(4795574)SDR DALA2023061004717Unknown · unknownSHIP 1801 -DIV- DIVERTED TO IAD DUE TO ALL LAVS INOP. CORRECTIVE ACTION: FOUND LAV TANKS FULL. SERVICED LAV TANKS. OPS CHECKS GOOD. (4714274)SDR SWIA202306290525Unknown · erodedWASTE AND WATER BOX INTERNAL HAS COMPOSITE EROSION DAMAGE. (C-CHECK RO 6/28/2023) REMOVED, REPAIRED, AND REINSTALLED WASTE WATER BOX, REF EMB175 SRM 51-40-08, 53-23-60/REPAIR 02. NO WEIGHT AND BALANCE ADJUSTMENT REQUIRED, REPAIRED TO ORIGINAL CONFIGURATSDR CALA2023052401624Toilet · inoperativeBOTH AFT LAV TOILETS STOPPED FLUSHING DURING DESCENT NO TIME TO FURTHER T/S, LAV SERVICED SEVERAL TIMES, NO HELP, COMPLETED SANITARY FLUSH TO CONFIRM NO CLOG IN Y DUCT FOR AFT ALL ITEMS VERIFIED C/W MEL. LAVS, COMPLIED WITH MEL 3830B NAME: DATE: 22-MAY-23- DESSDR DALA2023052304109Unknown · unknownSHIP 3307 LAV E ACIDIC ODOR IN DOOR 3 HANDICAP LAV. CORRECTIVE ACTION: R & R TOILET ASSY AT LAV 203. (4704482)SDR DALA2023041302960Unknown · unknownSHIP 3326 - DIV - TO DUB DUE TO REPORTS OF LAV LEAKING INTO CABIN. CORRECTIVE ACTION: DUB MTC CONFIRMED NO ACTIVE LEAK. A/C CLEANED AND DISPATCHED. (9890925)SDR DALA2023040502654Unknown · unknownSHIP 3311 WHILE PERFORMING REPETITIVE INSPECTION OF FWD WASTE VENT CORRSION. FURTHER CORROSION WAS DISCOVERED AT THE FWD WASTE EXHAUST VENT CUTOUT. CORRECTIVE ACTION: BLENDED CORROSION, .066 IN REMAINING THICKNESS. OUT OF LIMITS REF A330 SRM 53-41-11. REPAIREDSDR DALA2023040502653Unknown · unknownSHIP 3311 WHILE PERFORMING REPETITIVE INSPECTION OF AFT WASTE VENT. FURTHER CORROSION WAS DISCOVERED AT THE AFT WASTE EXHAUST VENT CUTOUT. CORRECTIVE ACTION: BLENDED OUT OF LIMITS , REPAIRED PER A330 SRM 53-41-11-300-022. (2702098)SDR SWIA2023042700006Unknown · corrodedLAV WASTE BOX DOUBLER CORRODED (C-CHECK RO 4/26/2023) REMOVED AND REPLACED LAV WASTE BOX SKIN DOUBLER REF SRM 51-40-08, 53-23-60/REPAIR 02. NO CHANGE TO WEIGHT AND BALANCE REQUIRED. SEE ATTACHED CONTINUATION CARD FOR WORK PERFORMED.SDR CALA2023032000816Lavatory · inoperativeALL LAVS WILL NOT FLUSH ON ARRIVAL DISCOVERED BOTH TANKS FULLL AND FOUL INDICATION FLAGGED. DUMPED THE TANKS LAVS CAME ONLINE IMMEDIATELY.SDR HALA2023030900036Decoder/Encoder · faultyATB - TOILETS NOT FLUSHING IN FLIGHT. WASTE SENSOR SHOWS FULL. REPLACED REF AMM 38-31-63. COND SAME. SWAPPED BACK. REPLACED DEU B (300RH7) REF AMM 23-73-47. TOILET CHECKS GOOD. OK FOR SERVICE.SDR AALA202303098791Toilet · leakingAIRCRAFT WAS GROUNDED: AIRCRAFT ODOR, SOURCE UNKNOWN, STRONGEST MID TO AFT CABIN. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE MID LAVATORY TOILET ASSEMBLY THAT WAS LEAKING AND REPLACED IT PER AMM 38-31-41. A SATISFACTORY LEAK / OPERATIONAL CHECK WAS ACCSDR AALA202303029623Toilet · leakingAIRCRAFT WAS GROUNDED: URINE SMELL IN AFT CABIN WITH APU BLEED ON-ALONG WITH A MUSTY SMELL MID CABIN INFLIGHT. MAINTENANCE ACCOMPLISHED TASK CARD 26L00021001 AND FOUND LAVATORY E TOILET ASSEMBLY LEAKING, CREATING THE SOURCE OF THE ODOR. MAINTEANANCE REPLACED TSDR DALA2023012400557Tube · corroded(LOG 2596014) DURING INSPECTION FOUND CORROSION ON TUBE DECLAM OF LAVATORY A. TUBE DECLAM OF LAVATORY A WAS REPAIRED PER ERA NO. 582489-14TR REV. A SECTION I: PERMANENT REPAIR.SDR CALA2023012300189Toilet · inoperativeTOILET FLUSH SYSTEM DOES NOT FLUSH N/A ALL LAVATORIES INOP AIRBORNE. FUNCTIONED NORMALLY ON GROUND. PERFORMED T/S ON TOILET FLUSH SYS, NO WASTE INDICATION DURING INDICATION AT AFT CABIN BACK TO NORMAL. TOMC NOTIFIED. AMM REF FLIGHT. NO C/B RELATED FOUND OUT. FSDR HALA2023051000173Unknown · unknownSHIP 393 HAL 393 EXPERIENCED SEVERE TURBULENCE EVENT WHICH CAUSED DAMAGE TO THE WALLS AND CEILINGS OF LAV H (L53) AND LAV V (L81) (REFERENCE ER/A 605060-14 FOR TIME LIMITED REPAIRS). THE OEM FOR BOTH DISCREPANT LAVATORIES IS DIEHL AVIATION. DIEHL PROVIDED TN-TSDR DALA2023010300021Toilet · cloggedDIVERTED TO JFK DUE TO TWO LAVATORIES INOPERATIVE ENROUTE. MTC C/W OVERWEIGHT LANDING INSPECTION, REMOVED BUNDLE OF PAPER TOWELS FROM WASTE DUCT AND CLEARED MEL FOR INOPERATIVE VACUUM BLOWER.SDR CALA2023010200010Toilet · leakingRIGHT AFT LAV LEAKING BLUE WATER.CARPETS SOAKED RH AFT LAV LEAK INSPECTED. NO ISSUES NOTED.SDR HALA2023010300001Deu · faultedETOPS - ALL LAVATORIES NOT WORKING IN FLIGHT, HEADING BACK TO LAX. PERFORMED CIDS POWER UPTEST AND FAULTED 300RH8. REMOVED AND REPLACED DEU-B 300RH8 IAW AMM 23-73-47 PB 401, OPS CHECK OF ALL LAV AS OKAY. AC OK TO CONTINUE. ORIG SUB DATE: 1/3/2023SDR CALA2023010200005Toilet · inoperativeNO FLUSH IN ANY LAVS ON LEFT SIDE OF AIRPLANE NO SUCTION IN LAVS A, C, AND G. LAV G HAS STANDING WATER IN TOILET. LAV @ DOOR 4L HAS SUCTION AND FLUSHES NORMALLY. REMOVE CLOG FROM AFT CARGO BETWEEN STATION 1600 AND 1800 AS REQUIRED OPS CK NORMAL AND LEAK CKSDR CALA2022122803512Nipple · missingPDA 3 VERBAL LAV SERVICE REPORT -- NIPPLE MISSING FOR LAV SERVICE -- SEE PHOTO PHOTO ADDED INSTALLED NEW LAV SERVICE NIPPLE. OK FOR SERVICE. CALLED LAV SERVICE TRUCK. REFERENCE 38-32-03-50.SDR DALA2022122788425Shutoff Valve · faultedDUE TO TOILET IN LAV J 206 CONTINUALLY FLOWING AND NOT ABLE TO SHUTOFF WITH WATER VALVE CLOSED OR CIRCUIT BREAKER PULLED. FOUND WATER SHUTOFF VALVE STICKY. EXERCISED VALVE SEVERAL TIMES AND CONFIRMED VALVE CLOSED.SDR DXTA2022122376990Cap · looseSTRONG VIBRATION FELT IMMEDIATELY AFTER TAKEOFF AND CONTINUED UNTIL TOUCHDOWN. SMALL VIBRATION IN FLIGHT CONTROLS. GENERATOR INDICATIONS WERE NORMAL. AFTER LANDING LAV CAP WAS FOUND LOOSE. COMPLIED WITH 05-50-27, AIRCRAFT NOISE AND VIBRATION INSPECTION, IAW SDR CALA2022122303480Lavatory · inoperativeALL LAVS INOP LAVS. WERE SERVICED . ALL LAVS FUNCTIONAL CHECK NORMAL. A/C BIS.SDR AALA202212207260Module · faultedAIRCRAFT WAS GROUNDED: ALL LAVATORIES WILL NOT FLUSH. FLIGHT DIVERTED TO CLT LANDING SAFELY. MAINTENANCE REPLACED THE VACUUM WASTE SYSTEM LOGIC CONTROL MODULE PER AMM 38-33-03-400-801 (AALA202212207260) AND WASTE TANK CONTINUOUS LEVEL SENSOR J3 PER AMM 38-33-0SDR AALA202212205147Sensor · faultedAIRCRAFT WAS GROUNDED: ALL LAVATORIES WILL NOT FLUSH. FLIGHT DIVERTED TO CLT LANDING SAFELY. MAINTENANCE REPLACED THE VACUUM WASTE SYSTEM LOGIC CONTROL MODULE PER AMM 38-33-03-400-801 (AALA202212207260) AND WASTE TANK CONTINUOUS LEVEL SENSOR J3 PER AMM 38-33-0SDR CALA2022121403384Circuit Breaker · trippedLAVS NOT FLUSHING WHILE T/S PER FIM 38-30. TASK 811 FOUND LAV VACUUM WASTE CTRL AND POTABLE WATER RESERVICED. TOMC AGREED TO PUT AC BACK IN OPEN ON P91 PANEL IN EE BAY. RESET BREAKER AND FLUSHED ALL LAVS SERVICE MULTIPLE TIMES WITH NO PROBLEMS. PERFORMED BITESDR R61A2022122900787Waste Box · corrodedWHILE AC WAS IN FOR HVY CK FOUND WASTE BOX ASSEMBLY DELAMINATED AND CORRODED. REPLACED WASTE BOX IAW SRM 51-43-04 PN 170-65078-405 AC REMAINS IN YQG FOR COMPLETION.SDR CALA2022113003260Line · blockedLEFT SIDE LAVATORIES INOPERATIVE DURING FLIGHT ABOVE 16K, LAVATORY TANK FULL LIGHT ILLUMINATED. FWD WASTE SYS INOPERATIVE LIGHT ILLUMINATED, AND FWD WASTE TANK SHOWS MORE THAN 3/4 FULL. UNABLE TO DUMP FWD WASTE TANK SYS, MAY HAVE A BLOCKAGE IN DUMP LINE. REMSDR DXTA2022111073680Water Heater · defectiveON PREFLIGHT IN THE LAV CLOSET, FOUND THE WATER SYSTEMS 7.5 AMP CIRCUIT BREAKER TRIPPED. CALLED MX & DECIDED TO RESET IT ON THE GROUND. IT WAS FUNCTIONING NORMALLY. CLIMBING THROUGH 7000 TO 8000 FEET, NOTICED AN ACRID ELECTRICAL ODOR. DECLARED AN EMERGENCY, SISDR CALA2022103103005Waste Tank · fullCAPT REPORTING FWD WASTE TANK SHUT DOWN INDICATING FULL. AFT WASTE TANK HAS NOW FILLED UP. AC209170 - YHZ MX RICHARD VERIFIED BOTH FWD AND AFT LAVS SERVICED AND CONFIRMED ALL LAVS FUNCTIONING NORMAL. AFT CABIN FWD TANK INDICATION SHOWING 3/4 FULL. AFT TANK SDR CALA2022103102995Drain Mast · cloggedWATER NOT DRAINING IN AFT OF AIRCRAFT. LAV SINKS, GALLEY DRAINS BACKING UP. REPEAT. UNCLOGGED AFT DRAIN MAST, VERIFIED AFT GALLEYS AND AFT LAV SINKS ARE WORKING NORMAL, PERFORMED DRAIN MAST HEATER OPERATIONAL CHECK AS PER AMM 30-71-00 VERIFIED OPS CHECKS SATISSDR YENA2022110301086Clamp · brokenFLT#113, MCO - CUN. '(AIRCRAFT PREFORMED AN AIR TURN BACK TO MCO).' "PREVIOUS WRITE-UP" ON CLIMB OUT, CRUISE, AND DESCENT CONSTANT VIBRATION IN COCKPIT / CABIN FILLED OUT ACFT VIB FORM MCC REQUESTED RTB ALL PARAMETER, ON VIB FORM; REF LP # 3482684, ITEM 2 (RIGSDR AALA202210310694Toilet · malfunctionedAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY TOILET OVERFLOWING ABOVE 10000 FEET. FLIGHT DIVERTED TO DEN LANDING SAFELY. **SUPPLEMENTAL REPORT FOR AALA202210270694: REPLACED LAVATORY E VACUUM TOILET ASSEMBLY PER AMM 38-32-15.** (CLOSED)SDR AALA202210270694None · noneAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY TOILET OVERFLOWING ABOVE 10000 FEET. FLIGHT DIVERTED TO DEN LANDING SAFELY. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202209155049Toilet Seat Lid · leakingAIRCRAFT WAS GROUNDED: A MALODOROUS SMELL WAS DETECTED IN THE AFT CABIN. ACCOMPLISHED SMOKE ODOR FUME INITIAL TROUBLESHOOTING JOB CARD 08L00021001. ODOR SOURCE WAS LAVATORY E TOILET ASSEMBLY LEAK. REPLACED TOILET ASSEMBLY; OPERATIONAL AND LEAK CHECK GOOD PER ASDR AALA202209085614Lavatory · inoperativeAIRCRAFT WAS GROUNDED: AIRCRAFT DECLARED AN EMERGENCY AND DIVERTED TO MIA DUE TO ALL LAVATORIES NOT FLUSHING IN FLIGHT. THE AIRCRAFT LANDED SAFELY AT MIA WITHOUT FURTHER INCIDENT. THE LAVATORIES WERE SERVICED AND SATISFACTORY OPERATIONAL CHECKS OF THE VACUUM SDR DALA2022083005796Unknown · unknownSHIP 5002 -DIV- TO MSP DUE TO ALL THE LAVATORIES BEING INOPERATIVE. CORRECTIVE ACTION: FOUND WASTE TANK FULL, SERVICED/EMPTIED WASTE TANK. OPS CHECK GOOD. (9021362)SDR YENA2022082900825None · failedFLT#1457, JFK-AUA. (AIRCRAFT PERFORMED AN AIR TURN BACK AND DECLARED AN EMERGENCY INTO JFK) DURING THE CLIMB A BLACK FLUID BEGAN LEAKING OUT OF FWD GALLEY FLOOR. FLUID HAS A STRONG SMELL OF HUMAN WASTE; FOUND LAV A TOILET ASSY LEAKING. REMOVED AND REPLACED LAVSDR CALA2022082402170Servicing Valve · leakingFUSELAGE BELLY DRAIN LEAKING BLUE WATER JUST UNDER AFT CARGO COMPARTMENT UNDER CARGO DOOR ENTRANCE 2011-01000 LAVATORY SPILL, SECTION 2B FROM WASTE TANK TO AFT CARGO DOOR, WITH-IN 7 DAYS. FOUND TANK BLUE WATER SEVICING LINE LEAKING, SECURED LINE BNUT, NO MORE SDR CALA2022082202139None · none*THIS IS A SUPPLEMENTAL REPORT TO THE ORIGINAL REPORT, WITH THE SAME CONTROL NUMBER, CIRCULATED ON 08/22/2022* AFT PIT BY LAV TANK FOUND TO HAVE OLD WASTE. LAV SPILL CLEAN UP PERFORMED BTW FRMS 56-67, STR 36R-36L IAW ECRA2011-01000, CORRECTIVE MEASURES B. IN-DSDR AALA202208225720Drain Mast · crackedAIRCRAFT WAS GROUNDED: AFT DRAIN MAST CRACKED. REPAIRED MAST PER EA 338549A.SDR AALA202208178921Toilet · odorAIRCRAFT WAS GROUNDED: CHANGED ATA FROM 1205 TO 2180 LEFT AFT LAVATORY VERY FOUL ORDER, CLEANED 3X AND DUMPED SEVERAL TIMES BUT ODOR LINGERS. FOUND AFT LEFT TOILET COUPLING LEAKING REMOVED AND REPLACED AFT LEFT TOILET PER AMM 38-32-01SDR SWAA2022080437846Flex Line · leakingDURING DESCENT PASSING FL 280 THE CABIN ALT WARNING HORN WENT OFF. THE CABIN ALT WAS 14;000. WE INITIATED A RAPID DESCENT. EMER. DECLARED & LANDING WAS UNEVENTFUL INTO OAK. / [01] PERFORMED EXCESSIVE CABIN PRESSURE LEAKAGE INSPECTION REF AMM 05-51-91. REF L/P SDR AALA202208027142Toilet · leakingAIRCRAFT WAS GROUNDED: STRONG FISH SMELL LAST 3 ROWS, AND STANDING LIQUID IN LAST ROW LEFT SEAT TRACKS. REPLACED AFT LEFT LAVATORY TOILET ASSEMBLY PER AMM 38-31-41.SDR CALA2022072001846Lavatory · unserviceableLAVATORY SYSTEM REQUIRES SERVICE. LAVATORY SYSTEM SERVICED PER 767-300 AMM 12-17-01, LAVS CHECKED OK PER AMM 38-32-00, CONTINUE IN SERVICE.SDR SIMA20220713001Lavatory · smokeAFT LAV SMELL BURNING FUSE. NO INDICATION ON EICAS.-C/A-NO ODOR FOUND IN LAV. NO MTX REQ. A/C IS GOOD FOR SERVICE.SDR DALA2022062304398Waste Tank · underservicedSHIP 1813 - DIV - TO JFK FOR LAV SERVICING DUE TO TWO LAVS ALREADY DEFERRED, ONE SYSTEM FULL AND AIRCRAFT DOWN TO ONE LAV WITH EXCESSIVE PASSENGER WAIT. CORRECTIVE ACTION: LAVS SERVICED IN JFK AND A/C CONTINUED TO ATL. 06/21 ATL: REMOVED, UNCLOGGED AND REINSTA
Back to JASC 3830