JASC 5210
Service difficulty reports · 45,713
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201708019036Battery Pack · dischargedTHE AIRCRAFT WAS NOT GROUNDED. PASSENGER ENTRY DOOR 3R EMERGENCY POWER ASSIST SYSTEM (EPAS) INOP. REMOVED AND REPLACED BATTERY PACK AT EPAS PASSENGER ENTRY DOOR 3R IAW AMM 52-11-20, OPS CHK GOOD FOR SVC.SDR IPXA2017073119987Seal · missingRUBBER SEAL ON FWD EDGE OF CREW DOOR MISSING. INSTALLED THE RUBBER SEAL IAW AMM 52-12-02.SDR IPXA2017073119995Handle · wornEXTERIOR CREW ENTRANCE DOOR HANDLE INTERNAL PANEL WORN. REMOVED AND REPLACED THE DOOR HANDLE IAW CMM 52-11-12, OPS CHECKED GOOD.SDR R61A201707290772Turnbuckle · damagedLOOSE ACTUATOR ROD NEAR THE L1 DOOR HANDLES. R & R THE TURNBUCKLE ON THE L1 DOOR HANDLE IAW AMM 52-11-52. OPS CHECKED GOOD.SDR AALA201708019007Washer · missingL4 DOOR ARM-DISARM HANDLE IS LOOSE. REPLACED MISSING WASHER AT L4 SERVICE DOOR ARM-DISARM HANDLE IAW AMM 52-13-00.SDR AALA20170730002Damper · low pressureL3 DOOR DAMPER PRESSURE IS LOW. SERVICED L3 DOOR DAMPER IAW AMM 52-22-00-614-002-A. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707319065Bottle · low pressureL4 DOOR PRESSURE BOTTLE INDICATOR OUT OF LIMITS. SERVICED L4 DOOR PRESSURE BOTTLE IAW AMM 52-10-00-614-001-A.SDR AALA201707319061Accumulator · low pressureL1 DOOR EMERGENCY ACCUMULATOR LOW. SERVICED L1 DOOR EMERGENCY ACCUMULATOR IAW AMM 52-10-10.SDR AALA20170729001Damper · low pressureL2 EMERGENCY EXIT DOOR DAMPER PRESSURE IN RED BAND. CHARGED THE L2 EMERGENCY DOOR DAMPER PER AMM 52-22-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR V0XD20170803002Mount Bracket · crackedPASSENGER DOOR POWER ASSIST MOTOR MOUNTING BRACKET IS CRACKED. REMOVED AND REPLACED PASSENGER DOOR POWER ASSIST MOTOR MOUNTING BRACKET (P/N: 601R317745-7) IAW SRM 51-42-06 AND CRJ700 SRM 51-40-11.SDR IPXA2017072819876Window · missingVIEWING WINDOW, CREW ENTRY DOOR DAMPER CYLINDER PRESSURE MISSING. INSTALLED NEW PLASTIC VIEWING WINDOW.SDR AALA201707319055Door · low pressureL4 DOOR DAMPER BOTTLE PRESSURE BELOW LIMIT. SERVICED L4 DOOR BOTTLE IAW AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20170728006Damper · low pressureL1 DOOR ACCUMULATOR PRESSURE IS LOW. SERVICED THE L1 DOOR ACCUMULATOR PRESSURE IAW AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20170728003Damper · low pressureL4 ENTRY DOOR DAMPER PRESSURE, LOW. SERVICED THE L4 ENTRY DOOR DAMPER IAW AMM 52-10-00.SDR AALA20170728002Damper · low pressureL3 EMERGENCY EXIT DOOR DAMPER PRESSURE IN THE RED BAND. SERVICED L3 DOOR DAMPER IAW AMM 52-22-00.SDR GTIA2017072702120Bottle · low pressureL2 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED ASSIST BOTTLE IAW AMM 52-10-00.SDR 2017F00157Door Seal · rupturedCREW NOTICED A "DOOR SEAL" ANNUNCIATOR IN CRUISE FOLLOWED BY A HISSING NOISE. THEY INITIATED A DESCENT TO FL300 AND THE NOISE STABILIZED, CABIN PRESSURE WAS NORMAL. ON LANDING IT WAS DISCOVERED THAT THE INFLATABLE DOOR SEAL HAD RUPTURED IN THE TOP AFT CORNER. SDR AALA201707319015Damper · low pressureL2 DOOR DAMPER PRESSURE BELOW LIMIT. SERVICED L2 DOOR DAMPER IAW AMM 52-22-00.SDR AALA201707319014Bottle · low pressureDURING CHECK, FOUND THE L4 DOOR EMERGENCY CYLINDER PRESSURE BELOW ALLOWABLE RANGE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR GTIA2017072602119Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE ASSIST BOTTLES TO PROPER LEVEL IAW AMM 52-10-00.SDR AALA20170727003Cylinder · low pressureL2 EMERGENCY EXIT DOOR DAMPER BELOW LIMITS. CHARGED THE L2 EMERGENCY EXIT DOOR DAMPER IAW AMM 52-22-00.SDR WVER2017072603Hinge · gougedPAX DOOR HINGE, FUSELAGE SIDE, AFT MOST LANDING GOUGED BY RETAINING PIN. REPAIRED HINGE IAW REO 670-53-21-582, REV -E, DATED 2017-06-05.SDR WVER2017072602Hinge · chafedPAX DOOR HINGE, NR 1 LUG CHAFED. REPAIRED IAW REO 670-52-11-511, REV-D, DATED 2017-06-05.SDR EBVR20170726001Washer · bentLOWER AFT CORNER OF THE MAIN ENTRANCE DOOR WAS DAMAGED DUE TO A SEQUENCING ROLLER OUT OF POSITION. THE OUT OF POSITION ROLLER ALLOWED THE EXTERIOR DOOR HANDLE TO INITIATE THE CLOSING OPERATION, WHICH ALLOWED THE DOOR HINGE TO MOVE, AND CREATE AN INTERFERENCE SDR AALA201707269051Track · dirtyL1 DOOR POWER ASSIST IS INOPERATIVE. DOOR BINDS 3/4 OF THE WAY DOWN. CLEANED L1 DOOR TRACK MECHANISM OF OLD GREASE BUILDUP AND LUBRICATED THE DOOR. OPS CHECKED GOOD IAW AMM 51-11-00.SDR SWIA201743631Web · corrodedPAX DOOR AFT WEB HAS CORROSION. REMOVED AND REPLACED AFT STAIR WEB TO PAX DOOR INNER SKIN IAW SRM.SDR GTIA2017072502116Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR HAD LOW PRESSURE. SERVICEDTHE L1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00.SDR AALA201707279009Damper · low pressureL3 EMERGENCY DOOR DAMPNER PRESSURE IS LOW. SERVICED L3 EMERGENCY DOOR DAMPNER IAW AMM 52-22-00.SDR AALA201707269038Guide · out of adjustFLIGHT ATTENDANT ADVISED MAIN CABIN DOOR DIFFICULT TO CLOSE. MAINTENANCE ADJUSTED AND TORQUED LOWER GUIDES IAW AMM 52-11-00-820-001-A, ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK. AIRCRAFT WAS GROUNDED.SDR DALA2017072605734Beam · crackedCRACKED NR 1 BEAM AFT EDGE AT L1 DOOR. THE BEAM WAS REPAIRED.SDR AALA20170726002Cylinder · low pressureL3 EMERGENCY DOOR DAMPNER ACCUMULATOR PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-22-00.SDR ASOA201707251805Drag Angle · crackedPAX DOOR AFT DRAG ANGLE IS CRACKED. COMPLIED WITH EC/TC REO 670-51-11-072, AND REO 670-52-11-072.SDR ASOA201707251804Panel · crackedTWO CRACKS ON AFT. PAX DOOR SIDE PANEL. COMPLIED WITH SRM 52-11-04-201-004-A01, AND TR 52-0025.SDR AALA201707279005Cylinder · low pressureFORWARD LEFT PASSENGER DOOR DAMPNER CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201707279004Cylinder · low pressureFORWARD LEFT PASSENGER DOOR DAMPER CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201707269011Cylinder · no testL2 DOOR DAMPER EMERGENCY OPERATION CYLINDER FAILED TO TEST. REMOVED AND REPLACED THE CYLINDER IAW AMM 52-13-14. OPS CHECKED GOOD.SDR AALA20170725001Selector Switch · inoperativeAIRCRAFT WAS IN BASE MAINTENANCE. R3 DOOR MODE SELECT SWITCH FOUND INOPERATIVE DURING EMERGENCY POWER ASSIST SYSTEM TEST. REMOVED AND REPLACED SWITCH PER AMM 52-11-28. OPERATIONAL CHECK GOOD.SDR GTIA2017072402108Strap · unsecureL1 SEAL BAD MAKE NOISE.TSM 52-11-00-810-A FOUND L1 DOOR SAFETY STRAP NOT FULLY RETRACTED IN DOOR FRAME BY 6'. RE-SECURED STRAP & PERFORMED GV1 OF DOOR SEAL PER AMM 52-10-00-220-006. NO DEFECTS. NOISE SUSPECTED TO BE FROM STRAP PREVENTING DOOR TO FULLY SEAL. A/SDR V0XD20170724003Skin · crackedPASSENGER DOOR SKIN IS CRACKED. CUT OUT DAMAGE, FABRICATED AND INSTALLED A REPAIR IAW REO 670-52-11-291, REV A, AND REO 670-52-11-965.SDR V0XD20170724002Panel · crackedPASSENGER DOOR FWD STAIR PANEL HAS A CRACK AT THE MIDSTEP. REPAIRED FWD STAIR PANEL IAW REO 670-52-11-104, REV H, SRM 51-41-00, 51-42-06, 51-25-06, AND NDT MANUAL PART 1 51-20-006.SDR RAIA201707230001Seal · dirtyMAIN CABIN DOOR DIFFICULT TO OPEN. CLEANED PAX DOOR RUBBER SEAL AND OPS CHECKED GOOD.SDR IPXA2017072419707Cable · brokenL1 DOOR OVERHEAD SLIDER CABLE ASSY BROKEN. R & R THE CABLE IAW MM 25-23-23, AND ESR 25-23-15-02.SDR DALA2017072505694Beam · crackedCRACKED BEAM NR 6 BS 177 AT THE L1 DOOR. THE BEAM WAS REPAIRED IAW ER/A 498178-14MA, REV ORIGINAL.SDR DALA2017072305708Fitting · wornWEAR ON RIGHT HAND LOWER FITTING AT VENTRAL DOOR. REPLACED IAW SRM 51-30-05.SDR AALA201707269039Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. CAUTION MESSAGE ON CIDS PANEL 2R DOOR, CHECK DOOR PRESSURE. MAINTENANCE SERVICED DOOR ASSIST BOTTLE PER AMM 52-13-14. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR DALA2017072305657Beam · crackedCRACKED BEAM NR 4 ON FWD EDGE AT FWD SERVICE DOOR R1. THE BEAM WAS REPLACED IAW SRM.SDR GTIA2017072202105Bottle · low pressureDURING WEEKLY CHECK FOUND L2 AND R2 DOOR DAMPER AND EMERGENCY OPERATION BOTTLE LOW. SERVICED L2 AND R2 DOOR DAMPER AND EMERGENCY OPERATION BOTTLE IAW AMM 52-13-14.SDR SWIA201743625Intercostal · corrodedPAX DOOR CENTER INTERCOSTAL HAS CORROSION AROUND WIRE HARNESS HOLE CUTOUT AT BS 315 - 335. REMOVED AND REPLACED THE PAX DOOR CENTER INTERCOSTAL IAW SRM. PRESSURIZATION LEAK CHECKS GOOD.SDR SWIA201743624Intercostal · corrodedPAX DOOR INTERCOSTAL HAS CORROSION ON UPPER FLANGE TOP SIDE AND UNDERNEATH AT NUTPLATE LOCATIONS. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM. PRESSURIZATION LEAK CHECK GOOD.SDR AALA201707269023Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. DOOR 4R SAYS CHECK PRESSURE. MAINTENANCE SERVICED DOOR ASSIST BOTTLE AT 4R DOOR PER AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.
Back to JASC 5210