JASC 5210
Service difficulty reports · 45,724
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201606299005Bottle · low pressureACFT WAS NOT GROUNDED. R4 DOOR ASSIST BOTTLE PRESSURE IN YELLOW RANGE. SERVICED ASSIST BOTTLE TO GREEN RANGE IAW AMM 52-10-00-614-001-A.SDR AALA201606299004Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. L4 DOOR ASSIST BOTTLE PRESSURE READS LOW. SERVICED DOOR ASSIST BOTTLE IAW AMM 25-60 11.SDR AALA201606299001Bottle · low pressureACFT WAS NOT GROUNDED. CIDS PANEL SHOWS CHECK R4 DOOR PRESSURE. SERVICED R4 DOOR ASSIST BOTTLE. SYSTEM CHECKS GOOD IAW 52-22-00.SDR V0XD20160629139Panel · crackedPASSENGER DOOR STAIR STRUCTURE IS CRACKED AT THE AFT SIDE OF THE MID STEP ASSEMBLY. REPAIRED CRACKED PASSENGER DOOR STAIR MID PANEL IAW REO 670-52-11-104, REV G DATED 2016-05-11 AND SRM 51-42-06.SDR FDEA201606282159Bracket · out of adjustDURING POST FLIGHT DISCOVERED R1 DOOR HANDLE, ARMED, INDICATOR VISIBLE WITH NO ARMED LIGHT AND THE DOOR DISARMED. GREEN IAW CREW DEBRIEF THE, ARMED, INDICATOR MENTIONED IN WRI IS THE, KNUCKLEBUSTER, THAT RECESSES ITSELF IN THE DOOR WHEN IN THE DISARMED CONDITSDR FDEA201606282158Dome Nut · corrodedCABIN L1 DOOR INTERNAL UPPER WEB, 03 EA DOME NUTS FOUND CORRODED.SDR SWIA201642407Skin · corrodedPANEL 832AL ON PASSENGER DOOR HAS CORROSION ON SKIN AROUND NUTPLATE HOLES. UNDER PANEL 832AL ON PASSENGER DOOR SKIN REPAIRED IAW STS EA.SDR ASOA2016062715121Skin · crackedTHE INNER SKIN OF THE PAX DOOR WAS FOUND TO BE CRACKED WHEN THE FWD RISOR PANEL WAS REMOVED. REPAIRED IAW REO 690-52-11-380.SDR V0XD20160703146Skin · crackedPASSENGER DOOR FWD INTERNAL SKIN UNDER LOWER ACCESS PANEL SHOWING SIGNS OF CORROSION NEAR NUT PLATE RECEPTACLE. PASSENGER DOOR FWD INTERNAL SKIN AT LOWER ACCESS PANEL CORRODED BEYOND LIMITS. 6 FASTER HOLES ARE ELONGATED WHERE THE STAIR STRUCTURE MATES WITH TSDR V0XD20160629138Cap · corrodedPASSENGER DOOR MIDCAP AND KICK ANGLE CORRODED. CLEANED KICK ANGLE AND REPLACED MIDCAP IAW SRMS 51-40-11, 51-25-06, 51-42-06, 51-21-11, 51-26-00, 51-41-00, AND 51-25-16.SDR AALA201606289002Cover · detachedAIRCRAFT IN BASE MAINTENANCE. R4 DOOR GIRT BAR FORWARD SWITCH COVER DETACHED. REATTACHED R4 DOOR GIRT BAR SWITCH COVER IAW SRM 52-10-02.SDR GTIA2016062701489Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR AALA201606279010Damper · low pressureAIRCRAFT WAS NOT GROUNDED: 3L DOOR DOES NOT SHOW ARMED ON CIDS PANEL ALSO CHECK DOOR PRESSURE MESSAGE ON CIDS. 3L DOES SHOW ARMED ON DOOR PAGE. SERVICED 3L DOOR DAMPER AND VERIFED OPS IAW AMM 52-10-00.SDR AALA201606279003Linkage · lack of lubeAIRCRAFT WAS NOT GROUNDED: 2L DOOR WHEN ARMING DOOR AND CLOSING VENT FLAPS BOTH LEVERS DO NOT TRAVEL THE SAME DISTANCE LEAVING A GAP BETWEEN LEAVER THAT CAUSED INJURY TO F/A HAND. CLEANED AND LUBED LINKAGE FOR 2L DOOR ARMING MECHANISM AND ACCOMPLISHED A SATISDR SWAA2016062753220Pin · not reportedMAIN CABIN ENTRY DOOR WILL NOT OPEN. R&R PIN ASSEMBLY PER AMM.SDR REXA2016062501342Skate Angle · crackedPASSENGER DOOR AFT SKATE ANGLE IS CRACKED AT ATTACH FASTENER. REMOVED & REPLACED THE AFT SKATE ANGLE IAW REO 601R-52-11-513.SDR SWIA201642327Intercostal · corrodedPAX DOOR INTERCOSTAL DD6 CORRODED. REPLACED THE INTERCOSTAL IAW SRM.SDR DALA2016062604939Web · wornWEAR ON UPPER WEB OVER UPPER HINGE AT AFT CABIN PRESSURE BULKHEAD DOOR. DAMAGE WEB WAS REPAIRED IAW SRM 52-01, FIG 4, SHEET 3.SDR SIMA20160625002Roller · out of adjustMAIN CABIN DOOR DIFFICULT TO OPEN FROM THE OUTSIDE. R & R UPPER AND LOWER FWD TEFLON GUIDES AND ADJUSTED THE FWD UPPER ROLLER IAW AMM 52-18-00. OPS CHECK GOOD.SDR IPXA2016062605038Skin · damagedL1 DOOR ENTRY DOOR OUTER SKIN DAMAGED. REPAIRED REF EO MD11-5210-61065-B.SDR N6WA2016062502Handle · defectivePASSENGER OUTER DOOR HANDLE CAUTION MSG INTERMITTENT DURING FLT. DEFERRED PASSENGER OUTER DOOR HANDLE IAW MEL 52-70-01, CAT A.SDR AALA201606269004Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR 2 CHECK, DOOR PRESSURE INDICATOR PLUS CAUTION LIGHT. SERVICED 2R DOOR PRESSURE.SDR REXA2016062401190Door · bindingFA REPORTS MAIN CABIN DOOR LEVER HARD TO OPEN AND CLOSE. THE GREEN WITNESS MARK DO ALIGN CORRECTLY. PERFORMED VISUAL INSPECT OF DOOR LINKAGES, SHOOT BOLTS, DOOR FRAME, BEARING RODS, AND CABLES. NO DEFECTS NOTED. COMPLETED MULTIPLE OPS CHECKS OF DOOR OPENINGSDR C77A20160628004Diaphragm · defectiveTHE L2 DOOR WAS FOUND DIFFICULT TO ARM AND DISARM, THE EVACUATION ESCAPE SLIDE BUSTLE PIN WAS FOUND DETACHED AND PNEUMATIC ASSIST BOTTLE PRESSURE WAS DEPLETED. THE L2 DOOR DIAPHRAGM ASSY WAS REPLACED IAW AMM AND WAS CHARGED. THE EVACUATION SLIDE MECHANISM WASDR N6WA2016062404Cable · unserviceableRAMP REPORTS PASSENGER DOOR WOULD NOT CLOSE. PERFORMED INSPECTION OF PASSENGER DOOR SUPPORT WHEEL AND FOUND CABLE UNSERVICEABLE. R & R SUPPORT CABLE IAW AMM 52-11-13, PERFORM OPS CHECK IAW AMM 52-11-13.SDR SIMA20160624003Roller · lack of lubeMAIN CABIN DOOR HANDLE DIFFICULT TO MOVE AND DOOR DIFFICULT TO OPEN AND CLOSE, MAY BE DUE TO DOOR MISALIGNMENT. LUBE ROLLERS AND DOOR HANDLE, DOOR OPS CHECK GOOD IN NORMAL OPERATION IAW AMM 52-10-00.SDR AALA201606259005Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR DOES NOT SHOW ARMED ON CIDS PANEL WITH CAUTION LIGHT. SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A. DOOR SHOWS ARMED ON CIDS PANEL.SDR AALA201606259004Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: 4R SLIDE ERROR MESSAGE ON CIDS PANEL CHECK DOOR PRESSURE. SERVICED 4R DOOR ASSIST BOTTLE AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 52-10-00-614-001A.SDR SWIA201642326Web · corrodedPAX DOOR AFT WEB HAD OUT OF LIMITS CORROSION. REMOVED AND REPLACED THE DOOR AFT WEB IAW SRM.SDR AALA20160623002Tube · corrodedAIRCRAFT WAS IN BASE MAINTENANCE. L4 DOOR EMERGENCY POWER ASSIST SYS TUBE FOUND IS CORRODED. R & R TUBE IAW AMM 52-11-22.SDR SIMA20160623003Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN AND CLOSE. PERFORMED MAIN CABIN DOOR LUBE IAW AMM 52-10-01. OPS CHECK GOOD.SDR AALA201606249002Bottle · low pressureAIRCRAFT WAS NOT GROUNDED, DOOR 2R BOTTLE PRESSURE LOW. SERVICED R2 DOOR BOTTLE PRESSURE IAW AMM 52-22-00.SDR IPXA2016062405000Actuator · inoperativeL1 ENTRY DOOR WILL NOT LATCH FULL OPEN OR CLOSE. MOTOR IS INTERMITTENT. R & R L1 DOOR ELECTRICAL ACT REF MM 52-11-01. OPS NORMAL, IPC 52-11-05-05.SDR UHLA201606230333Cover · unsecureL2 DOOR NOT SHOWING GIRT BAR INDICATOR. RESECURED L2 DOOR BUSTLE COVER IAW MM 52-12-22.SDR SWIA201642354Plate · gougedPAX DOOR FWD CENTERING PLATE GOUGED ACROSS RIVET HEAD. REMOVED AND REPLACED WITH NEW CENTERING PLATE IAW SRM.SDR ASAA2016062217129Guide Arm · out of adjustF/A REPORTS L-1 DOOR HARD TO CLOSE. ACFT GROUNDED. FOUND L-1 DOOR NOT COMING IN PARALLEL WITH DOOR CUTOUT. ADJUSTED L-1 DOOR GUIDE ARM REF AMM 52-11-21. L-1 DOOR OPERATES NORMAL.SDR ASOA2016062214980Door · jammedMAIN PASSENGER DOOR WOULD NOT OPEN, TOOK SEVERAL ATTEMPTS TO OPEN BEFORE DOOR WOULD OPEN. COMPLIED WITH INSPECTION OF PASSENGER DOOR AND DOOR FRAME NO DEFECTS NOTED. COMPLIED WITH FUNCTIONAL TEST OF PASSENGER DOOR, OPS CHECK GOOD. NO DEFECTS NOTED OK IAW AMSDR AALA201606239003Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. R4 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-13-14.SDR DALA2016062304875Beam · crackedCRACK ON BEAM NR 1 FWD EDGE AT R1 DOOR IN REF NRTC, SN 1600. BEAM WAS REPLACED IAW SRM 51-30-2 AND 51-30-5 AND DWG 9911579, REV L. BEAM WAS REPLACED IAW SRM 51-30-2 AND 51-30-5 AND DWG 9911579, REV L.SDR DALA2016062304874Beam · crackedCRACK ON BEAM NR 1 FWD AND AFT EDGE AT MAIN ENTRY PASSENGER DOOR. BEAM WAS REPAIRED IAW SRM 52-05D, FIG 81 AND 82.SDR FDEA201606222103Lever · out of adjustWITH THE HANDLE IN DISARMED POSITION ON THE R1 DOOR, THE SLIDE WARNING PLACARD STILL INDICATED ARMED. SLIDE LIGHT WAS EXTINGUISHED. T/S & FOUND RETRACTABLE INDICATION DOOR FOR DISARM. LEVER OUT OF ADJUSTMENT. ADJUSTED RETRACTABLE INDICATION DOOR REF AMM 52SDR REXA2016062101118Angle · corrodedPASSENGER DOOR MID CAP ANGLE HAS CORROSION AROUND FASTENER HOLES. MID CAP ANGLE REQUIRES REPLACEMENT. INSTALLED NEW PASSENGER DOOR MID CAP ANGLE. REINSTALLED PASSENGER DOOR PROXIMITY SWITCH, PERFORMED OPS TEST OF PASSENGER DOOR IAW SRM 51-41-02-001-001-A01,SDR AALA201606229013Seal · missingAIRCRAFT IN BASE MAINTENANCE. R2 DOOR EMERGENCY OPERATION, DOOR DAMPER, GAGE, SIGHT GLASS CENTER SEAL IS MISSING. REPLACED R2 DOOR EMERGENCY OPERATION, DOOR DAMPER IAW AMM 52-13-14-0401.SDR AALA20160622005Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. R4 DOOR EMERGENCY CYLINDER ACCUMULATOR BOTTLE PRESSURE READS LOW. SERVICED R4 DOOR EMERGENCY/CYLINDER ACCUMULATOR BOTTLE TO PROPER LEVEL IAW AMM 52-10-00.SDR ASOA2016062114979Shaft · lack of lubeF/A REPORTS PASSENGER DOOR VERY DIFFICULT TO OPEN. CYCLED PASSENGER DOOR SEVERAL TIMES, OPS TEST GOOD IAW AMM 52-11-00. APPLY LUBE TO PASSENGER DOOR INNER HANDLE SHAFT ASSY IAW AMM 12-20-52. ACFT OK FOR SERVICE.SDR SIMA20160621001Roller · lack of lubeMAIN DOOR HARD TO OPEN. LUBED MAIN PASSENGER DOOR ROLLERS IAW AMM 52-00-04. OPS CHECK GOOD.SDR DALA2016062204834Skin · crackedCRACK ON DOOR SKIN BETWEEN BEAM NR 4 AND BEAM 5 AT FWD MAIN ENTRY DOOR. SKIN WAS REPAIRED IAW ERA 501106-14MA, REV C AND ETI-88-16-151, REV 2.SDR LK2R2016071189672Motor · failedMAIN CABIN DOOR MOTOR ACTUATOR FAILED TO BRAKE DURING OPENING OF THE CABIN DOOR WHILE THE AIRCRAFT WAS IN MAINTENANCE. DOOR EXTENDED AT A RAPID UNCONTROLLED RATE AND DAMAGED THE DOOR STRUTS AFTER REACHING FULL EXTENSION.SDR SWAA2016062153105Fastener · missingL1 DOOR WOULD NOT OPEN. FOUND MISSING HARDWARE. INSTALLED HARDWARE ASSEMBLY IAW AMM.SDR FDEA201606192068Collar · failedGUST LOCK CRACKED ON L1 FWD ENTRY DOOR. REMOVED L1 DOOR HOLD OPEN LOCK COLLAR AND INSTALLED NEW SPLIT COLLAR IAW AMM 52-11-08-8. OPS CHECK NORMAL ON GROUND.
Back to JASC 5210