Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR A6WA201240731Shaft · crackedSERVICE DOOR OUTER HANDLE WILL NOT STOW FROM OUTSIDE OR INSIDE. INSPECTED SERVICE DOOR FOUND OUTER HANDLE SHAFT CRACKED. DOOR OPERATES PROPERLY FORM INSIDE REF LP 228429/4 FOR MEL.SDR DALA12004087007Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM AT R1 DOOR FAILED TEST. REPLACED BATTERY AS PER AMM 52-11-20-401. OPS CHECKED GOOD.SDR USAA2012073000034Diaphragm · damagedR-4 DOOR HAS CIDS MESSAGE. REMOVED AND REPLACED R-4 DOOR ASSIST DIAPHRAGM AND SERVICED DOOR ASSIST BOTTLE.SDR MASA2012072534994Track · dirtySERVICE DOOR WILL NOT OPEN. CLEANED DEBRIS FROM DOOR TRACKSDR UALA2012072604057Trigger · frozenMAIN CABIN R-4 DOOR TRIGGER FORK IS FROZEN. REMOVED AND REPLACED TRIGGER FORK PER MM AND OPS CHECKED GOOD.SDR UHLA2012072500231Rod · brokenTHE 2R DOOR ARM/DISARM MESSAGE FOR SLIDE NOT INDICATING PROPERLY. REPLACED BROKEN ROD ON VISUAL DOOR INDICATOR PER AMM 52-42-22, OPS CHECK GOOD.SDR SIMA20120724008Pin · bentDURING MAINTENANCE BASE INSPECTION, FOUND THE ACCESS DOOR PIN RECEPTACLE BENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED IAW EO EM-52MR-316. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR USAA2012072500002Actuator · low pressureCIDS MESSAGE CHECK PRESSURE SLIDE 4R PRESS WITHIN GREEN ON SLIDE GAUGE. MAINTENANCE SLIDE PRESS CHECKS OK FOUND DOOR DAMPER ACTUATOR LOW. SERVICED AS REQUIRED, NO MESSAGES NOTED.SDR USAA2012072600016Structure · crackedC5 CHECK - FORWARD SERVICE DOOR CRACKED AT NR 5 AFT DOOR STOP CUTOUT. REPAIRED DOOR IAW EA 104153 .25 INCH CRACK.SDR USAA2012072600015Structure · crackedC5 CHECK - FORWARD SERVICE DOOR CRACKED AT NR 4 AFT DOOR STOP CUTOUT. REPAIRED DOOR IAW EA 104153.SDR SWIA201231329Seal · lack of lubeSERVICE DOOR DOES NOT OPEN. (FLT 6468) LUBRICATED THE SERVICE DOOR SEAL.SDR SWIA201231312Seal · damagedSERVICE DOOR REQUIRES EXCESSIVE FORCE TO OPEN AND CLOSE. (FLT 4805) REPLACED SERVICE DOOR SEAL.SDR AALA20120720021Angle · corrodedTHE FORWARD SERVICE DOOR CREASE ANGLE IS CORRODED. REMOVED AND REPLACED THE CREASE ANGLE PER AARD 51-00-05-1.SDR SWAA2012072306123Door Frame · crackedR2 DOOR FWD FRAME CRACKED AT EDGE OF UPPER HINGE CUTOUT CORNER. REPAIRED FRAME PER SRM & MM.SDR UHLA2012072000227Screw · defectiveR1 DOOR BUSTLE FWD FASTENER WILL NOT ENGAGE. REMOVED AND REPLACED R1 DOOR BUSTLE SCREWS AND INSTALLED IAW EMB 170 MM 25-23-0.SDR QXEA2012071900698Bearing · corrodedAFT RT SERVICE DOOR 2 LIFT AND LATCH MECHANISM SHAFT BEARINGS HAVE CORROSION. REPLACED BEARINGS IAW AMM 52-41-11-400-801.SDR USAA2012072000001Mechanism · out of adjustC11 CHECK - OUT OF ADJUSTMENT STRIKER MECHANISM DIMENSION "B" AT DOOR 842 (R2). ADJUSTED STRIKER MECHANISM DIMENSION "B" AT DOOR 842 (R2) IAW A319 AMM 52-13-14-820-002-A STEP 4A, ITEM (2)(A)-(C).SDR ASOA2012072001950Door · lack of lubeSERVICE DOOR CANNOT BE OPENED FROM THE OUTSIDE. LUBED SERVICE DOOR, OPS CHECKED GOOD, REF MM 52-41-00.SDR UHLA2012071700219Diaphragm · damagedR1 DOOR AUTO OPENS. REMOVED AND REPLACED R1 DOOR PNEUMATIC ASSY DIAPHRAGM IAW EMB 170 MM 52-41-5.SDR ASOA2012072601975Door · out of adjustFORCE TO COMPLETE THE UNLATCH CYCLE FOR THE FORWARD GALLEY SERVICE DOOR EXCEEDS ALLOWABLE LIMITS. ADJUSTED LATCH MECHANISM TO ALLOWABLE LIMITS IAW AMM 52-41-02-820-801-A01. FUNCTIONAL TEST OF THE GALLEY SERVICE DOOR COMPLY WITH IAW AMM CH 25-41-00-720-802.SDR ASOA2012071901932Handle · lack of lubeSERVICE DOOR OUTER HANDLE WILL NOT POP OUT TO OPEN. LUBRICATED SERVICE DOOR OUTER HANDLE. OPS CHECKED GOOD IAW AMM 52-41-00. SDR CLOSED.SDR AALA20120715002Door · crackedRIGHT NUMBER 2 DOOR HAS CRACK AT UPPER HINGE IN RADIUS. INSTALLED DOUBLER PER SRM 52-10-02-2R 1 AND EA COMP-52-024975.SDR GTIA20120713456Accumulator · low pressureR2 SERVICE DOOR OPENING ACCUMULATOR REQUIRES N2 SERVICE. SERVICED R2 DOOR OPENING ACCUMULATOR IAW AMM 52-10-00-614-001-A.SDR UALA2012071203761Shroud · brokenCACP R4 DOOR TRIM PANEL BROKEN. REPLACED SHROUD.SDR USAA2012071000009Actuator · low pressureCIDS PANEL - CHECK DOOR PRESSURE 4R. MAINTENANCE REFILLED DOOR PRESSURE 4R EMERGENCY ACTUATOR.SDR MASA2012070934976Door · lack of lubeSERVICE DOOR WILL NOT OPEN. MAINTENANCE CLEANED AND LUBED DOOR.SDR USAA2012071000001Cylinder · low pressureR3 DOOR EMERGENCY OPERATION CYLINDER PRESSURE LOW. MAINTENANCE SERVICED R3 DOOR EMERGENCY OPERATIONAL CYLINDER, LEAK CHECK OKAY.SDR UALA2012070603649Gate · crackedDOOR 2R UPPER HINGE CUTOUT CRACKED AND SMC5 DOOR 1R UPPER GATE CRACKED. REMOVED DOOR 2R. ACCOMPLISHED CHECK. REPAIRED PER MM.SDR UALA2012070503583Gate · crackedDR 2R HAS CRACK .25 LONG AT UPPER HINGE CUTOUT. ALSO FOUND R1 DOOR UPPER GATE CRACKED AT SECOND RIVET.SDR UALA2012070503618Gate · corrodedR4 DOOR LOWER GATE HAS CORROSION ON BOTTOM LIP. INSTALLED LOWER GATE.SDR R61A201207040345Damper · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE R1 DOOR DAMPER CORRODED. MAINTENANCE REMOVED AND REPLACED THE R1 DOOR DAMPER IAW EMB 190 AMM 52-41-27. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR UHLA2012070200204Indicator · obstructedR1 DOOR SLIDE INDICATOR INOP. FOUND DEBRIS OBSTRUCTION, REMOVED AND CLEANED SLIDE LENS VIEW INDICATION, OPS CHECK GOOD IAW EMB 170 AMM.SDR CALA2012070200424Door · unsecureAIRCRAFT FAILED TO PRESSURIZE AFTER TAKEOFF. F/A REPORTED AIR RUSHING OUT SOUND AT R2 DOOR. ON ARIVAL, FOUND R2 DOOR INCORRECTALLY CLOSED. VERIFIED DOOR OPERATION, ALL CHECKED NORMAL. ACFT OK TO CONTINUE.SDR UHLA2012070100203Pin · out of positionDOOR R2 ARMING LEVER DOOR FELL OFF. RE-INSTALLED DOOR HINGE COVER PIN AS REQUIRED, OPS CHECK GOOD IAW EMB 170 AMM.SDR USAA2012070200033Door Frame · crackedQ4 CHECK - FORWARD SERVICE DOOR FRAME CRACKED FROM LOWER HOLE AT BS 328. REMOVED AND REPLACED DOOR.SDR QXEA2012063000644Arm · chafedAFT RT SERVICE DOOR MAIN HINGE ARM IS CHAFED ALONG LOWER EDGE. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. MAPPED DAMAGED AREA, MAXIMUM MATERIAL LOSS OF .022" CONFIRMED BLENDED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND TO BE WITHIN SDR AALA20120628010Structure · crackedRIGHT NUMBER 2 DOOR UPPER HINGE CUTOUT IS CRACKED. INSTALLED DOUBLER PER SRM 52-10-02-2R 1.SDR USAA2012062700014Cylinder · low pressureR-1 DOOR SLIDE AIR PRESSURE IN YELLOW RANGE. SERVICED R-1 DOOR ASSIST BOTTLE PRESSURE TO GREEN BAND IAW AIRBUS MAINTENANCE MANUAL 52-10-00-614-001A.SDR MASA2012062334927Arm · brokenON POST FLIGHT, FOUND SERVICE DOOR JAMMED . MAINTENANCE FOUND DOOR HINGE ARM BROKEN. REPLACED HINGE ARM.SDR UALA2012062903412Gate · gougedR1 DOOR LOWER GATE HAS A DEEP GOUGE. INSTALLED NEW R1 LOWER GATE ASSY.SDR USAA2012062500016Cylinder · low pressureCIDS PANEL INDICATION FOR DOOR R-1 CHECK PRESSURE. SERVICED DOOR R-1 DAMPER CYLINDER TO PROPER RANGE IAW AIRBUS MAINTENANCE MANUAL 52-10-00.SDR USAA2012062500002Bottle · low pressureAFT RIGHT DOOR ASSIST BOTTLE PRESSURE LOW. MAINTENANCE SERVICED DOOR ASSIST BOTTLE.SDR UHLA2012062100197Indicator · lack of lubeTHE 2R DOOR LATCH INDICATOR NOT LINED UP. CLEANED AND LUBED R2 DOOR CLOSED INDICATION IAW EMB 170 MM. OPS CHECK GOOD.SDR YENA20120621537Beam · corrodedFLT 6405 MCO-BNA, ON HEAVY MAINTENANCE CHECK FOUND AFT SERVICE DOOR LOWER BEAM 4 AFT FR 8 STRINGER 17R AT RIVET HOLE SIZE OF DEFECT. W=.580 X .580 NORMINAL .157" REMOVED .055" MATERIAL REMOVED 35 PERCENT REF N/R 8548. ACCOMPLISHED TASK CARD E12-358-01.
REMOSDR QXEA2012062100512Frame · scratchedSERVICE DOOR HAS SCRATCHES ON AFT EDGE FRAME IN MULTIPLE LOCATIONS. SMOOTHED DAMAGE IAW SRM 51-14-00-02-03. CONFIRMED AREAS TO BE CRACK FREE REF NTM 51-00-01-250-801 PT 6. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 2. FOUND WITHIN LIMITS.SDR UALA2012062203366Mechanism · out of adjustMAIN CABIN R-1 DOOR MODE SELECTOR JUMPS DURING INTERIOR HANDLE OPERATION. CHECKED AND ADJUSTED DOOR EMERGENCY MECHANISM PER MM. OPS TESTED GOOD.SDR UALA2012062203372Gate · corrodedNR 1 DOOR UPPER GATE HAS EVIDENCE OF CORROSION AT LEVELING COMPOUND AREA. RIGHT DOOR UPPER GATE HAS EVIDENCE OF CORROSION.SDR UALA2012062203371Gate · gougedR-1 DOOR LOWER GATE HAS A DEEP GOUGE. INSTALLED NEW R-1 LOWER GATE ASSY. WORK PERFORMED ON SCAL. NEW GATE INSTALLED PER SC AL NR AND RII INSPECTED.SDR SWIA201231049Linkage · lack of lubeSERVICE DOOR IS DIFFICULT TO OPEN. (FLT 6499) CLEANED DEBRIS FROM SERVICE DOOR AREA AND LUBRICATED THE SERVICE DOOR HANDLE LINKAGE.SDR SWAA2012062105123Skin · crackedR1 DOOR SKIN CRACKED ON FWD SKIN OF DOOR ABOVE LOWER CUTOUT FOR HINGE. REMOVED & REPLACED SKIN IAW SRM.
Back to JASC 5240