Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2012062100005Damper · low pressure2S CHECK - R1 DOOR DAMPER READS 0 PSI. REPLACED R1 DOORS DAMPER DIAPHRAGM IAW A319 AMM 52-10-00-610-001-A AND 52-10-00-614-001-A, TW DDN49733, R1 DOOR DAMPER PSI READING IS IN RANGE.SDR ASOA2012062701828Angle · corrodedSERVICE DOOR ANGLE AT FS 319 IS CORRODED. R & R SVC DOOR ANGLE WITH A NEW SERVICEABLE ANGLE IAW SRM 51-42-06 AND 51-41-02 .SDR UALA2012062203342Mechanism · wornMAIN ENTRY DOOR 1 RIGHT TRIGGER MECH WORN. REPLACED TRIGGER MECH.SDR SWAA2012062005097Door Frame · crackedR1 DOOR CRACKED IN THE AFT FRAME. REMOVED AND REPLACED R1 DOOR IAW MM.SDR GTIA20120615441Gust Lock · brokenR2 DOOR CLOSED BUT SHOWS OPEN ON ECAM AND GUST LOCK NOT WORKING. ACCOMPLISHED OPS CHECK OF DOOR WARNING SYS IAW AMM 52-71-00-710-001-A. OPS CHECK GOOD ACCOMPLISHED DOOR OPS CHECK IAW AMM 52-11-00-820-001-A. DOOR LATCHED IN FULL OPEN POSITION.SDR USAA2012061500002Cylinder · low pressureCAB PSI INDICATION ON 3R DOOR (UPON ARRIVAL AT PHL) LOCATED ON CIDS PANEL NOT NORMAL. MAINTENANCE SERVICED R3 DOOR EMERGENCY OPS CYLINDER, LEAK CHECK OK.SDR AALA20120613020Structure · crackedRIGHT NUMBER 2 DOOR UPPER HINGE CUTOUT IS CRACKED. TRIMMED TO REMOVE CRACK AND INSTALLED REPAIR DOUBLER PER SRM 52-10-02-2R 1.SDR UALA2012061203245Skin · crackedRIGHT NR 2 MED EXTERNAL SKIN CRACK AT UPPER HINGE CUTOUT. CATEGORY B REPAIR ACP IAW SRM 52-10-01 REPAIR 3. PER SRM TABLE 2, INSPECTION REQUIRED EVERY 3,000 CYCLES. REMOVABLE STRUCTURAL COMPONENT (RSC) MARKED PER 51-00-80. CF STICKER APPLIED. INSPECTIONS TSDR DALA1242520635Gate · corrodedR4 DOOR UPPER GATE HAS CORROSION AND DISBONDED LEVELING COMPOUND THROUGH OUT. REMOVED CORROSION AND FOUND OUT OF LIMITS. REPLACED GATE IAW SRM 51-40-05.SDR DALA12001603355Structure · damagedDAMAGED L4 DOOR AFT CORNER. REPAIRED PER ERA 504326-14.SDR SWIA201230973Door Seal · contaminatedSERVICE DOOR CANNOT BE OPENED FROM OUTSIDE. (FLT 5618) CLEANED STICKY SUBSTANCE FROM SERVICE DOOR SEAL.SDR SWIA201230964Trim Panel · noisyLOUD CRACKLING SOUND AND OCCASIONAL LOUD POP. (FLT 6430) REMOVED S TRIM FROM SERVICE DOOR.SDR USAA2012061100026Bottle · low pressureDOOR 2R ASSIST BOTTLE LOW AT 1200 PSI, TEMP 20 DEGREES CELSUS. SERVICED DOOR ASSIST BOTTLE IAW AIRBUS MAINTENANCE MANUAL 52-10-00-614-001.SDR UALA2012060803159Counterbalance · defectiveMAIN ENTRY DOOR 4R BODY TORQUE TUBE COUNTER BALANCE MAKES POPPING NOISE DURING OPENING & CLOSING. REPLACED COUNTER BALANCE.SDR DALA1235965807Actuator Cable · failedMAINTENANCE DISCOVERED THE R2 DOOR EMERGENCY POWER ACTUATION CABLE FAILED TEST. ADJUSTED R2 DOOR EMERGENCY POWER ACTUATION CABLE IAW B757-300 AMM 52--11. ADJUSTMENT CHECKS GOOD.SDR USAA2012060600004Cylinder · low pressureR4 EMERGENCY OPERATION CYLINDER PRESSURE LOW. MAINTENANCE SERVICED DOORS R4 EMERGENCY OPERATIONS CYLINDER.SDR UALA2012060503110Cable · out of adjustIN FLT, DOOR 2R DOOR ARMING LEVER IS NOT FLUSH, IT MOVES OUT SLIGHTLY. CABIN PRESSURE LIGHT BLINKS. REPEAT SAMC TEXT: ADJ OF TELEFLEX CABLE REQUIRED, FLOOR FITTINGS CLEANED AT SFO. DOOR 2R FOUND SPRING ON FWD END OF GIRT BAR BINDING & HANGING UP WHEN OPEN &SDR UALA2012060503111Spring · lack of lubeDOOR 2R FOUND SPRING ON FWD END OF GIRT BAR BINDING AND HANGING UP WHEN OPEN AND CLOSING DOOR IN DISARM MODE REF MM 52-11-22 PG 518. LUBED GIRT BAR MOUNT SPRING ASSY, REF AMM52-13-22. OPS NORMAL.SDR USAA2012060400005Pneumatic System · low pressureAFT SERVICE DOOR PNEUMATIC ASSEMBLY PRESSURE LOW. MAINTENANCE SERVICED THE PNEUMATIC ASSEMBLY OF RIGHT AFT SERVICE DOOR.SDR SWAA2012062005111Web · corrodedR2 DOOR WEB CORRODED ON BOTTOM OF WEB AT STA 967. REMOVED AND REPLACED WEB IAW BAC DWG & SRM.SDR UHLA2012053100171Mechanism · lack of lubeR2 DOOR DIFFICULT TO DISARM. LUBED ARM/DISARM VENT FLAP HANDLE MECHANISM IAW EMB 170 MM 52-70-00, OPS CHECK GOOD.SDR UHLA2012053100170Mechanism · lack of lubeR2 CABIN DOOR DISARM HANDLE WILL NOT MATCH FLUSH WITH LARGER VENT HANDLE. THE DISARM HANDLE MUST BE PUSHED THE LAST INCH OF MOVEMENT AND IT IS VERY HARD TO DO SO. LUBED ARM/DISARM LEVEL MECHANISM ON R2 DOOR IAW EMB 170 MM 52-70-00. OPS CHECK GOOD.SDR USAA2012060400001Cylinder · damagedR2 DOOR CYLINDER DAMPER SHEER PIN STUCK IN HOUSING. REMOVED AND REPLACED R2 DOOR DAMPER CYLINDER IAW AMM 52-13-14-0401. OPS CHECKED GOOD.SDR AALA20120528007Structure · corrodedCORROSION ON INNER AFT RIGHT LOWER SERVICE ENTRY DOOR CHORD. REMOVE AND REPLACE CHORD.SDR USAA2012052900042Cylinder · low pressureFLIGHT ATTENDANT CIDS PANEL SHOW ESCAPE SLIDES AT R1 AND R3 LOW PRESSURE. SERVICED R3 DOOR DAMPER / EMERGENCY CYLINDER. OPS CHECKED GOOD.SDR USAA2012052900041Cylinder · low pressureFLIGHT ATTENDANT CIDS PANEL SHOW ESCAPE SLIDES AT R1 AND R3 LOW PRESSURE. SERVICED R1 DOOR DAMPER / EMERGENCY CYLINDER. OPS CHECKED GOOD.SDR SWAA2012062005109Angle · corrodedR2 DOOR Z-ANGLE CORRODED BETWEEN STA 960 TO STA 1016. REMOVED AND REPLACED CHORD IAW BAC DWG.SDR A6WA201240576Seal · damagedUNABLE TO OPEN SERVICE DOOR FROM OUTSIDE, HANDLE POPS OUT BUT WILL NOT TURN. INSPECTED AND LUBED SERVICE DOOR, MOVED ACFT FWD AND BACK. DOOR IS STILL DIFFICULT TO OPEN AND CLOSE FROM THE OUTSIDE IAW AMM 52-11-00. R & R SERVICE DOOR SEAL, OPS AND LEAK CHECKSDR ASOA201201695Door · lack of lubeSERVICE DOOR IS VERY DIFFICULT TO OPEN. LUBRICATED SERVICE DOOR & OPS CHECKED GOOD IAW AQMM 52-41-00. (SDR CLOSED)SDR USAA2012052900001Cylinder · low pressureR-4 DOOR EMERGENCY OPS CYLINDER PRESSURE LOW. MAINTENANCE SERVICED R-4 DOOR EMERGENCY OPS CYLINDER, LEAK CHECK IS OKAY.SDR USAA2012052400003Cylinder · low pressureCIDS CAUTION LIGHT ON FORWARD CIDS PANEL. MAINTENANCE REPLENISHED 4R DOOR ASSIST CYLINDER TO LIMITS.SDR USAA2012052400018Bottle · low pressureC1 CHECK - DOOR ASSIST BOTTLES FOR R3 DOOR NEEDS TO BE SERVICED. SERVICED R3 DOOR ASSIST BOTTLE IAW A330 AMM 52-1000-600-801-A, NO LEAKS NOTED.SDR USAA2012052400017Bottle · low pressureC1 CHECK - DOOR ASSIST BOTTLE FOR R1 DOOR NEEDS TO BE SERVICED. SERVICED R1 DOOR ASSIST BOTTLE IAW A330 AMM 52-1000-600-802-A, NO LEAKS NOTED.SDR ASOA201201675Handle · lack of lubeSERVICE DOOR CAN NOT BE OPENED FROM OUTSIDE ACFT. TROUBLESHOT SERVICE DOOR, LUBE OUTER HANDLE. DOOR OPS CHECKED OK IAW AMM 52-40-00.SDR R61A201205170290Flap · out of adjustCREW REPORTED R1 VENT FLAP INOP. MAINTENANCE ADJUSTED AND RIGGED FLAPPER DOOR PER EMB AMM.SDR UHLA2012051600159Bottle · low pressureR2 DOOR AUTO ASSIST OPENED DOOR EVEN THOUGH DOOR WAS DISARMED. DOOR WOULD QUICKLY OPEN THEN HISS ONCE OPEN. FOUND R2 ASSIST BOTTLE LOW 1300 PSI. SERVICED BOTTLE, PERFORMED OPS CHECK, COULD NOT DUPLICATE. NO LEAKS NOTED IAW EMB 170 MM 52-42-51.SDR UHLA2012051500158Unknown · malfunctionedR2 DOOR VENT FLAP HANDLE STICKS. PERFORMED OPS CHECK OF R2 DOOR VENT FLAP, ALL OPS CHECK GOOD. COULD NOT DUPLICATE IAW CMM 52-42-2.SDR AALA20120515012Door · corrodedSURFACE CORROSION ON JACK SCREW DOOR. INSTALLED NEW DOOR SKIN PER AARD 52-40-00-1.SDR CA120627006Liner · debonded(CAN) WHILE CLIMBING THRU 10K FEET, AFT F/A REPORTED THAT, SOMETHING APPEARED TO STICKING OUT THE SERVICE DOOR. F/A COULD SEE OUT THE DOOR. PRESSURIZATION WAS NORMAL AND DOOR INDICATION NORMAL. MAINTENANCE FOUND THE LOWER DOOR LINER CRES KICK PLATE HAD FALLESDR QXEA2012051400386Plate · looseCLIMBING THROUGH 10,000, INFORMED THAT SOMETHING APPEARED TO BE STICKING OUT DOOR , AND F/A COULD SEE OUT OF DOOR. DOOR SECURED AND ACFT WAS PRESSURIZING AT 11,000. RETURNED TO FIELD AND ACCOMPLISHED A UNEVENTFUL LANDING. FOUND AFT SERVICE DOOR KICK PLATE HASDR QXEA2012051200379Door · lack of lubeGALLEY SERVICE DOOR HARD TO OPEN. CLEANED AND LUBED DOOR SEAL AND INSIDE DOOR HANDLE. OPS CHECKED GOOD. DOOR OPERATES SMOOTHLY, NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR SWAA2012051103897Angle · corrodedR1 DOOR INNER CHORD CREASE BEAM ANGLE CORRODED. REMOVED AND REPLACED ANGLE IAW SRM.SDR SWAA2012051003880Door Frame · crackedR1 DOOR CRACKED LOWER FRAME AFT CORNER. REMOVED AND REPLACED R1 DOOR PER AMM.SDR USAA2012050700011Cylinder · low pressureR2 DOOR ASSIST PRESSURE LOW. SERVICED R2 DOOR TO PROPER PRESSURE IAW AIRBUS MAINTENANCE MANUAL 52-10-00-614-001.SDR REXA2012050500619Striker · corrodedSERVICE DOOR ANGLE AND SEAL STRIKER ARE CORRODED. REMOVED AND REPLACED SERVICE DOOR LOWER SEAL STRIKER IAW CRJ 900 SRM 51-42-06. REPAIRED MOUNTING IAW REO 690-21-357 T/W B98606 P/N SH670-31407-5 T/W B23893 P/N SH670-3141-2-7 AAR SM-31.SDR UHLA2012050500140Flap · malfunctionedR2 VENT FLAP HANDLE HANGING DURING DISARMING. TROUBLESHOT R2 VENT FLAP IAW EMB 170 MM 52-12-25. OPS CHECK GOOD.SDR R61A201205050280Lanyard · out of positionCREW REPORTED R1 DOOR WILL NOT DISARM. MAINTENANCE RE-INSTALLED DOOR LANYARD PIN PER EMB AMM, AND DOOR OPS CHECKED GOOD.SDR ASOA201201560Skin · corrodedCORROSION ON SERVICE DOOR INNER SKIN AROUND SCREW HOLES. REMOVED CORROSION, NO MATERIAL LOSS FOUND IAW SRM 51-21-06. TREATED PRIMED AND PAINTED IAW IAW SRM 51-21-11.SDR R61A201205020269Screw · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTNENACE FOUND THE LAV SERVICE DOOR HINGE HAS CORROSION. MAINTENANCE FOUND NO EVIDENCE OF CORROSION ON HINGE, REPLACED HARDWARE IAW EMB 175 AMM 20-10-01. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR USAA2012050300002Cable · lack of lubeTHE 2R DOOR HANDLE HARD TO ARM. MAINTENANCE LUBRICATED DOOR ARMING CABLE OPERATIONAL CHECK IS GOOD.
Back to JASC 5240