Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201023860Pin · out of adjustUNABLE TO OPEN SERVICE DOOR FROM OUTSIDE. (FLT 5959) ADJUSTED PIN ON HANDLE ASSEMBLY.SDR USAA2010031790602Damper · out of adjustSAL - C6 - EES - R-2 DOOR IS OUT OF ADJUSTMENT AT DIMENSION "A" BETWEEN STRIKER & FINGER ON THE DOOR DAMPER MECHANISM & EMERGENCY OPERATION CYLINDER. ACCOMPLISHED ADJUSTMENT AT DIMENSION "A" BETWEEN STRIKER & FINGER ON THE DOOR DAMPER MECHANISM & EMERGENCY OPSDR SWIA201023831Seal · lack of lubeGALLEY SERVICE DOOR WILL NOT OPEN FROM OUTSIDE. (FLT 6222) LUBED SEAL AND ACTUATING LEVERS.SDR USAA20100315EM008Door · lack of lubeBOS - THE LEFT REAR DOOR DIFFICULT TO OPEN BY THE CATERER AND FLIGHT ATTENDANT. THE MISALIGNMENT OF THE DOOR CAUSED PAINT TO BE REMOVED FROM THE FRAME OF AIRCRAFT DOORWAY IN TWO PLACES. MAINTENANCE OPERATED THE DOOR NUMEROUS TIMES, ALIGNMENT IS SATISFACTORY.SDR SWIA201023784Handle · dirtySERVICE DOOR WILL NOT OPEN FROM THE OUTSIDE. (FLT 5869) CLEANED SERVICE DOOR OUTER HANDLE ASSEMBLY.SDR USAA2010030890518Cylinder · low pressureFLT 396 - DFW-LAS - EMERGENCY EGRESS SYSTEM - R1 DOOR ASSIST ACCUMULATOR LOW (1300 PSI). SERVICED DOOR ASSIST BOTTLE ACCUMULATOR PER TASK 52-10-00-614-001.SDR QXEA2010030800154Angle · corrodedRFD - C CHECK - GALLEY SERVICE DOOR LOWER MIDCAP ANGLE HAS CORROSION ON IT. REMOVED MID CAP ANGLE, NO FURTHER CORROSION FOUND, REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. BLENDS ARE WITHIN LIMITS IAW SRM 53-21-23-101-002-A01. TREATED, PRIMED AND PAINTED SDR C2XA10TY032Bushing · migratedTYS A/C CURRENTLY IN A C-CHECK STATUS WHEN INSPECTION FOUND THE SERVICE DOOR SWING ARM BUSHINGS MIGRATED. MAINTENANCE REPAIRED THE SWING ARM WITH NEW BUSHINGS IAW EMB 145EC5240-01036. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.SDR AALA20100304TUL06Beam · crackedFORWARD SERVICE DOOR TOP BEAM FORWARD END CRACKED. INSTALLED DOUBLER REPAIR PER SRM 52-05-00 FIGURE 25.SDR SWIA201023797Seal · tornGALLEY SERVICE DOOR WOULD NOT OPEN FROM THE OUTSIDE. (FLT 6126) REPAIRED TORN SEAL.SDR SWIA201023777Roller · lack of lubeGALLEY SERVICE DOOR IS HARD TO OPEN. (FLT 4536) LUBED SERVICE DOOR ROLLER AND DOOR SEAL.SDR A6WA201040184Seal · dirtyAT GATE- SERVICE DOOR WILL NOT OPEN FROM INSIDE OR OUTSIDE. OPENED AND CLEANED SERVICE DOOR SEAL IAW AMM 52-41-07. FUNCTION CHECKED GOOD.SDR USAA20100304SB029Door Track · lack of lubeDCA - PILOT REPORTED THE LEFT AFT SERVICE DOOR WAS DIFFICULT TO OPEN. MAINTENANCE APPLIED LUBRICANT TO DOOR TRACK. DOOR OPENS NORMALLY.SDR SWIA201023757Seal · lack of lubeSERVICE DOOR WILL NOT OPEN. (FLT 6606) LUBED SERVICE DOOR SEAL.SDR QXEA2010030200150Mechanism · dirtyPDX- CREW REPORTS THAT THE SERVICE DOOR IS HARD TO OPERATE. MAINTENANCE CLEANED DEBRIS FROM THE LOCKING MECHANISM. OPERATIONAL CHECKS GOOD. RETURNED TO SERVICE. NO PARTS REPLACED.SDR SWIA201023766Roller · lack of lubeSERVICE DOOR WILL NOT OPEN. (FLT 5905) LUBRICATED SERVICE DOOR ROLLERS AND HANDLE.SDR USAA2010030190466Cylinder · out of adjustCHK - PHX - EMERGENCY EQUIPMENT/EMERGENCY EGRESS SYSTEM. WHILE PERFORMING TASK CARD F1C25305 EVACUATION DOOR SLIDE DEPLOYMENT, R1 DOOR ASSIST BOTTLE DID NOT OPERATE. FOUND TO BE IMPROPERLY ARMED. REMOVED AND REPLACED SHEAR PIN AND BURST DISC (DIAPHRAGM). SSDR USAA20100301EM005Cylinder · low pressureATL - LEFT AFT SERVICE DOOR PNEUMATIC ASSIST CHARGE IS LOW. MAINTENANCE SERVICED THE LEFT AFT SERVICE DOOR PNEUMATIC ASSIST ASSEMBLY PER AMM 52-12-51-614-801A.SDR FDKA2010022500030Door · dirtyGALLEY SERVICE DOOR SQUEALING IN FLIGHT. CLEANED AND LUBED, OPS GOOD.SDR QXEA2010030100142Stop Fitting · corrodedPDX - AFT SERVICE DOOR STOP FITTING NR 14 BOLTS AT POSITION C ARE CORRODED. REPLACED BOLTS WITH NEW IAW SB 84-52-61.SDR QXEA2010030100143Nut Plate · damagedPDX - AFT SERVICE DOOR STOP 15 REQUIRED NUTPLATES TO BE CHANGED TO BOLTS AND NUTS IAW SB 84-52-61. REPLACED NUTPLATES WITH BOLTS AND NUTS PER SB 84-52-61 STEP 31.SDR QXEA2010030100140Attach Angle · corrodedRFD - CORROSION FOUND ON GALLEY SERVICE DOOR MID CAP ATTACH ANGLE. REMOVED AFT DOOR STOP FITTINGS AND LOWER SILL ANGLE. ANGLE IS CORRODED BEYOND LIMITS. INSTALLED NEW ANGLE AND HARDWARE.SDR QXEA2010030100139Structure · corrodedRFD - CORROSION ON THE FORWARD INBOARD SIDE OF THE GALLEY SERVICE DOOR. BLENDED CORROSION. BLENDED AREA WITHIN LIMITS IAW SRM 53-21-23-002-A01. TREATED AREA AND PRIMED AND PAINTED.SDR QXEA2010031000136Fitting · corrodedPDX- C1 CHECK. AFT SERVICE DOOR STOP FITTING NR 19 ANCHOR NUTS AT POSITIONS B AND D ARE CORRODED. REMOVED SKIN ON FORWARD SIDE OF DOOR TO GAIN ACCESS. REMOVED NUT PLATES AND INSTALLED BOLTS AND NUTS REF SB 84-52-61. INSTALLED SKIN IAW SRM 51-42-15, 51-42-05SDR USAA2010022590444Cylinder · low pressureFLT 1518 - SAN - EES - R-1 DOOR ASSIST BOTTLE PRESSURE LOW. MAINTENANCE SERVICED R-1 DOOR ASSIST BOTTLE PER AIRBUS MAINTENANCE MANUAL 52-10-00-03-614.SDR AALA20100223TUL08Pan · gougedRIGHT NUMBER 1 DOOR HANDLE PAN HAS GOUGES. INSTALLED NEW HANDLE PAN IN RIGHT NUMBER 1 DOOR PER ESO 90284.SDR ASOA201000311Seal · lack of lubeCATERING PERSONEL AND F/A REPORT SERVICE DOOR BEING DIFFICULT TO CLOSE AND OPEN. CLEANED AND LUBRICATED DOOR SEAL AND STRIKER IAW MM 12-20-52. OPS CK GOOD IAW MM 52-41-00.SDR FDEA201002230495Attach Fitting · crackedWASTE WATER SERVICE PANEL HOLD OPEN ROD OTBD ATTACH FITTING ON THE SERVICE DOOR IS CRACKED. REPLACED ATTACH FITTING IAW SRM 51-72-10, PAGE 2.SDR SWAA101208Beam · crackedDURING SCHEDULED HC2 CHECK, FOUND CABIN R1 DOOR AFT LOWER ACCESS BEAM CRACKED FROM EDGE FWD BELOW HI-LOKS. REMOVED AND REPLACED DOOR PER MM.SDR V0XR20100222001Fitting · corrodedSERVICE DOOR FITTING HAS CORROSION.SDR SWIA201023719Door Track · obstructedGALLEY SERVICE DOOR WON'T OPEN. (FLT 4574) REMOVED DEBRIS FROM DOOR HANDLE TRACK.SDR USAA2010022490443Cylinder · low pressureFLT 27 - MCO-PHX - EMERGENCY EGRESS SYSTEM - CIDS PANEL SHOWS CHECK DOOR PRESSURE R4. SERVICED 4R DOOR ASSIST BOTTLE IAW 52-22-00.SDR SWIA201023702Latch · lack of lubeSERVICE DOOR IS DIFFICULT TO OPEN. (FLT 6175) LUBRICATED LATCH.SDR AALA20100215TUL02Structure · misrepairedIMPROPER REPAIR AT AFT SERVICE DOOR HOLD OPEN HOOK AREA. REMOVED IMPROPER DOUBLER, DRILLED NEW DOUBLER TO FIT AND INSTALLED NEW DOUBLER ON AFT SERVICE DOOR PER SRM 52-05-00, FIG 54.SDR USAA2010031190563Damper · weakSAL - S2 - EES - R-1 DOOR HAS HARD IMPACT WHEN FULLY OPEN. REPLACED R-1 DOOR DAMPER CYLINDER & PERFORMED OPERATIONAL CHECK IAW A320 AMM 52-11-14. OPS CHECK GOOD.SDR USAA2010030990548Damper · defectiveSAL - S2 - EES - HARD IMPACT WHEN FULLY OPENING R-2 DOOR. REPLACED DOOR DAMPER CYLINDER AT R-2 DOOR & ACCOMPLISHED LEAK TEST IAW A320 AMM 52-13-14-400-001.SDR A6WA201040108Handle · damagedSERVICE DOOR HARD TO OPEN (FROM INSIDE). CK OPS TEST OF SERVICE DOOR LATCH MECHANISM AND CHECKS BAD DOOR CLOSED AND LOCKED REF 180875/2 FOR MEL CMH 2-12-12:20. REMOVED SERVICE DOOR HANDLE, CLEANED AND LUBED RETURN TUBE AND RETURN GUIDE BOLT IAW AMM 52-41-03SDR ASOA201000213Handle · stiffGALLEY SERVICE DOOR REQUIRES EXCESSIVE FORCE TO COMPLETE THE UNLATCH CYCLE. PERFORMED FUNCTIONAL TET OF THE GALLEY SERVICE DOOR IAW AMM 51-41-00-720-801 FUNCTIONAL TEST FAILED EXCESS FORCE TO OPEN GALLEY SERVICE DOOR. ADJUSTED THE GALLEY SERVICE DOOR IAW AMSDR USAA2010021190339Cylinder · low pressureFLT 77 - SEA - EES - DOOR ASSIST PRESSURE LOW AT 1 RT. MAINTENANCE SERVICED PRESSURE AT DOOR 1 RT CYLINDER.SDR USAA2010020890299Cylinder · low pressureFLT 140 - RDU-PHX - EMERGENCY EGRESS SYSTEM - R2 DOOR ACCUMULATOR LOW PRESSURE. SERVICED R2 DOOR ACCUMULATOR TO PROPER PRESSURE.SDR USAA2010020890303Diaphragm · leakingBFM - EES - C1 CHECK - R-1 DOOR ASSIST BOTTLE PRESSURE IS LOW. REPLACED THE PERCUSSION MECHANISM DIAPHRAGM AND RE-SERVICED THE R1 DOOR ASSIST BOTTLE IAW A330 AMM 52-10-00-02 AND 52-10-00-03.SDR QXEA2010020900084Door · stuckSERVICE DOOR WILL NOT OPEN. INTERNAL HANDLE WILL ONLY ROTATE TO THE 12 O'CLOCK POSITION. RESEQUENCED/CYCLED DOOR HANDLE, SERVICE DOOR OP'S NORMAL. RETURNED TO SERVICE. NO PARTS REPLACED.SDR R61A20100067Linkage · lack of lubeCREW REPORTED THE R-2 DOOR IS EXTREMELY HARD TO CLOSE. MAINTENANCE TROUBLESHOT AND LUBED THE R-2 DOOR INDICATION LINKAGE PER EMB AMM, OPS CHECK GOOD AFTER THAT.SDR UALA2010020800478Beam · crackedDOOR 5R UPPER BEAM CRACKED AT THE 8TH & 10TH FASTENER HOLE FROM FWD END. MAJOR REPAIR ACCOMPLISHED: INSTALLED REINFORCING REPAIR.SDR SWAA100668Door Frame · crackedDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR AFT FRAME CRACKED 2ND STOP FITTING DOWN. REMOVED AND REPLACED R1 DOOR PER MM.SDR AALA20100201TUL12Gate · corrodedLEFT NUMBER 4 PASSENGER SERVICE DOOR GATE HAS CORROSION ON LOWER AFT CORNER. REMOVED CORRODED LOWER GATE AND INSTALLED NEW LOWER GATE PER ESO 90108.SDR AALA20100201TUL14Beam · crackedFORWARD SERVICE DOOR TOP FORWARD BEAM CRACKED. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 52-05 FIGURE 25.SDR USAA2010020290257Cylinder · low pressureFLT 327 - ACA-PHX - EMERGENCY EGRESS SYSTEM - R2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R2 DOOR ASSIST BOTTLE PER PLACARD.SDR USAA2010020190244Actuator · bentPIT - C1 - MAJOR REPAIR - PNEUMATIC ACTUATOR ASSEMBLY STRIKER ASSEMBLY PUNCTURE PIN BENT AT FORWARD SERVICE DOOR. REPLACED FORWARD SERVICE DOOR ACTUATOR ASSEMBLY IAW E190 MM 52-41-51.SDR F3LA2010021000333Hook · inoperativeDURING C4 S1 C CHECK INSP NOTED R2 DOOR OPEN/CLOSE INTERNAL HANDLE MOVES TO CLOSED POSITION BEFORE THE DOOR IS IN THE HOLE. MX ADJUSTED THE UPLOCK HOOK IAW AMM 52-11-21-400-001.
Back to JASC 5240