Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202008289006Damper · low pressureAIRCRAFT WAS GROUNDED: 4R DOOR LOW PRESSURE LIGHT CAME ON DURING TAXI. SERVICED AFT R/H DOOR DAMPER IAW J/C 26L80052001.SDR SWAA2021081211318Outlet · damagedR1 DOOR POWER OUTLET BOX IS DAMAGED. / REPLACED R-1 DOOR POWER OUTLET BOX AS PER B737-700 SRM 51-40-02-0G-0SDR SWIA202053030Skin · chafedSERVICE DOOR OUTER SKIN AROUND OUTER HANDLE IS CHAFED, MARKED. C-CHECK RO 10/4/2020. REPAIRED SERVICE DOOR OUTER SKIN AROUND OUTER HANDLE CHAFE, REF REO.SDR SWIA202053029Pan · corrodedSERVICE DOOR FORWARD LOWER PAN HAS CORROSION. C-CHECK RO 10/4/2020. REMOVED AND REPLACED SERVICE DOOR FWD LOWER PAN, REF REO. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH ATTACHED TASK.SDR AALA2020082539012Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR DAMPER ASSIST PRESSURE LOW. SERVICED DOOR ASSIST DAMPER IAW AMM 52-10-00, OPS CHECK GOOD.SDR AALA2020090429017Damper · low pressureAIRCRAFT IN BASE MAINTENANCE - R1 PASSENGER CREW DOOR, DAMPER LOW PRESSURE. REMOVED AND REPLACED R1 DOOR DAMPER PER AMM 52-11-14.SDR DALA2020082102835Bottle · low pressureDURING SERVICE CHECK FOUND RT AFT SERVICE DOOR EOAM BOTTLE LOW. SERVICED EOAM BOTTLE PER A220 AMP BD-500-A-J52-46-08. REQUIRED INSPECTION ITEMS COMPLETED.SDR ASAA2020082813096Doubler · crackedEXTERNAL POWER DOOR LOWER CUTOUT CRACKED. GROUNDED - YES. CUT OUT DAMAGE AND REPAIRED WITH DOUBLER AND FILLER, IAW B737-800 SRM 53-10-15-2R-4 ALTERNATIVE 1. ALODINED IAW B737-800 SRM 51-20-01 AND PRIMED IAW BOEING SOPM 20-41-02. THIS IS A CATEGORY "A" REPASDR ASAA2020081753023Handle · out of positionFLIGHT ATTENDANT REPORTS R1 DOOR WILL NOT LATCH COMPLETELY, GROUNDED YES. REPOSITION OUT SIDE HANDLE, OPERATED NORMALLY. OK FOR SERVICE.SDR AALA2020081739018Damper · low pressureAIRCRAFT IN BASE MAINTENANCE: R4 DOOR ASSIST BOTTLE PRESSURE LOW. PERFORMED SERVICING OF DOOR R4 PASSENGER DOOR ASSIST BOTTLE (DAMPER) IAW AMM 52-10-00-614-001A.SDR SWAA2020083107966Scuff Plate · corrodedRUST ON SCUFF PLATE HARDWARE SERVICE DOOR AT AFT GALLEY AREA. / REPLACED ON SCUFF PLATE HARDWARE SERVICE DOOR AT AFT GALLEY AREA IAW AMM 53-11-01-420-801.SDR R61A2020081100593Door · bindingR2 DOOR STICKING. CLEANED AND INSPECTED R2 DOOR, OPS CHECK GOOD.SDR AALA202008119005Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED, R1 DOOR EMERGENCY OPERATION CYLINDER PRESSURE AT 1600 PSI AT 70 DEG F, BELOW LIMITS. SERVICED R1 DOOR EMERGENCY OPERATION CYLINDER PRESSURE TO SERVICEABLE LIMITS IAW AMM 52-10-00. NO LEAKS NOTED.SDR DALA202008112761Door · fodR1 DOOR WOULD NOT ARMED. REMOVED FOD. THE R1 DOOR CHECKED OK IAW AMM 52-11.SDR AALA202008059005Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR R2 (RIGHT REAR) DOOR DAMPER LOW. SERVICED R2 DOOR DAMPER PER AMM 52-10-00.SDR IPXA2020080258557Door · inoperativeCABIN DOOR FWD RT WONT OPEN AFTER BEING DISARMED. DEFERRED R1 CABIN DOOR PER MEL 52-10-3-1-2-1, DI# M715510 ASSIGNED.T/S PER FIM 52-11-00-810-802. FOUND R1 DOOR UP LIMIT SWITCH INTERMITTENT. R/R SWITCH IAW AMM 20-50-00. VERIFIED SWITCH ADJUSTMENT IAW AMM 52-1SDR AALA202008039002Stop Fitting · wornAIRCRAFT IN BASE MAINTENANCE - R1 DOOR STOPS WORN (4 FORWARD, 2 AFT). REMOVED AND REPLACED 6 EACH DOOR STOPS (4 FORWARD, 2 AFT) ON R1 DOOR PER AMM TASK 52-11-31-400-002-A.SDR DALA2020073102686Door · fodAFTER LVL OFF 2R PRESSURE LIGHT CAME ON AND DOOR SHOWS DISARMED ON STAYS ARMED IF HANDLE PUSHED DWN, INTERIOR . PERFORMED INSPECTION ON DOOR 2R AND CLEANED FOD IAW AMM 52-13, ACFT OK FOR SVC.SDR SWIA2020090452241Skin · corrodedSERVICE DOOR HAS CORROSION ON ITS AFT FACE (MARKED). C-CHECK RO 9/1/2020. REMOVED CORROSION FROM THE SERVICE DOOR AFT PAN, REF. CRJ200 SRM AND FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH MHIRJ REO. PERFORMED PRESSURE CHECK REF CRJ 200 AMM, CHECK GSDR AALA202007249007Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FOUND DOOR DAMPER CYLINDER BOTTLE BELOW LIMITS AT 900 PSI. RECHARGED R4 DOOR DAMPER CYLINDER BOTTLE TO ALLOWABLE LIMITS REF 52-10-00. OPS CHECK NORMAL.SDR AALA202007249005Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED: CABIN R1 DOOR NEEDS TO BE SERVICED. FILLED CABIN R1 DOOR ACCUMULATOR WITH NITROGEN IAW AMM 52-10-00. OK FOR SERVICESDR AALA202007229020Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R3 EMERGENCY EXIT DOOR DAMPER PSI FOUND BELOW GREEN LEVEL. RECHARGED EMERGENCY DOOR DAMPER R3 IAW AMM 52-22-00.SDR AALA202007229019Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R2 EMERGENCY DOOR DAMPER PSI NOT IN GREEN RANGE. RECHARGED DOOR DAMPER ON R2 DOOR IAW AMM 52-22-00.SDR AALA2020072109008Damper · low pressureAIRCRAFT WAS NOT GROUNDED: 4R DOOR CHECK DOOR PRESSURE ANNUCIATOR ON CIDS PANEL. CHARGED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER OF THE 4R DOOR IAW AMM 52-10-00. NO LEAKS DETECTED AT THIS TIME.SDR AALA202007209006Stop Fitting · wornAIRCRAFT IN BASE MAINTENANCE, R1 DOOR, FOUR FORWARD DOOR STOPS WORN . REPLACED THE DOOR STOPS IAW AMM TASK 52-11-31-400-002-A.SDR 120B2020070800038Rod · failedEMPENNAGE PANEL 313AL STOW ROD WILL NOT STOW OPEN.SDR SWAA2020071397730Handle · out of positionAFT SERVICE DOOR HANDLE INTER MECHANISM CLOCK WRONG. REPOSITIONED DOOR HANDLE PER AMM 52-41-31.SDR AALA2020070769002Cylinder · glazedAIRCRAFT IN BASE MAINTENANCE, R1 DOOR DAMPER CYLINDER GLAZED, REPLACED THE DOOR DAMPER CYLINDER IAW AMM 52-13-14-400-001-B.SDR DALA2020070762546Retainer · damagedR2 DOOR AFT SIDE STOP PAD PIN SAFETY NOT INSTALLED CORRECTLY. REINSTALLED A NEW SPRING RETAINER AND CHECKED STOP CLEARANCE AMM 52-11.SDR SWAA2020072197531Beam · crackedA CRACK INDICATION ON SERVICE DOOR UPPER BEAM 5 RH AT FWD GALLEY AREA (1 EA) / REPLACED SERVICE DOOR UPPER BEAM # 5 RH AT FWD GALLEY AREA IAW SRM B737-700 51-40-02 AND DRAWING 141A6516 REV D AND EO #52-41-140SDR SWAA2020072197532Beam · crackedCRACK INDICATION ON SERVICE DOOR LOWER BEAM 4 RH AT FWD GALLEY AREA (1 EA) / REPLACED SERVICE DOOR UPPER BEAM # 4 RH AT FWD GALLEY AREA IAW SRM 737-700 51-40-02; 51-10-02 AND DRAWING #141A6516 REV. D AND EO #52-41-14093 REV 1SDR SWAA2020072197423Beam · crackedCRACK FOUND AT R1 SERVICE DOOR STRUCTURE LOWER BEAM PN 141A6536-14 AT THE I/B FASTENER ADJACENT RADIUS / REMOVED AND REPLACED BEAM PN 141A6536-14 AT R1 SERVICE DOOR STRUCTURE LOWER AREA PER REF. B737 DWG. 141A6516 AND 141A6535; NEW BEAM INSTALLED PN 141A6536U2SDR SWIA2020072951509Striker · corroded* SERVICE DOOR LOWER SEAL STRIKER SCREW HOLES ARE CORRODED. REMOVED CORROSION FROM SERVICE DOOR LOWER SEAL STRIKER "OUT OF LIMITS" REF CRJ700 SRM (ORIGINAL: .120) - (REMAINING: .077) - (LOSS: .043). REMOVED AND REPLACED SERVICE DOOR LOWER SEAL STRIKER REF DRASDR SWAA2020062393529Handle · looseAFT SERVICE DOOR INTERIOR HANDLE IS LOOSE. TIGHTENED AFT SERVICE DOOR HANDLE PER MM. 52-13-00SDR SWIA202006251172Web · corrodedREFERENCE CAMP 21126432. CORROSION ON THE FWD 2 SERVICE DOOR WEBS P/N SH670-32040-3 FOR THE PLATE PROTECTOR AND FOUND TO BE OUT OF LIMITS PER SRM. REPAIR DETERMINED TO BE MINOR. REMOVED AND REPLACED FWD 2 SERVICE DOOR WEBS. REFERENCE TO CRJ 700 SRMSDR SWAA2020070696578Rib · crackedFWD SERVICE DOOR CRACKED IN THE RADIUS OF RIB NR 4 OF THE HANDLE BOX HOUSING. REMOVED AND REPLACED FWD GALLEY SERVICE DOOR. ADJUSTMENTS AND LEAK TESTS GOOD PER AMM 52-41-00. PN ON: 141A6516-20M SN ON: 002449 PN OFF: SN OFF: 0520055.SDR DALA2020061982488Door · fodR4 DOOR WILL NOT ARM. FOUND DEBRIS IN DOOR AREA. REMOVED DEBRIS AND OPS CHECKED THE DOOR WAS OK IAW AMM 52-11.SDR SWIA202006251170Mount · corrodedDAMAGE TO SERVICE DOOR MOUNTING ANGLE P/N SH670-31996-3 IS OUT OF LIMITS AND DETERMINED TO BE MINOR REPAIR REFF CAMP 21108578.REMOVED AND REPLACED SERVICE DOOR MOUNTING ANGLE P/N SH670-31996-3 REFERENCING CRJ 700 SRM.SDR SWIA2020071451307Retainer · corrodedUPON PROVIDED ACCES TO TREATMANT OF CORROSION DAMAGE ON SERVICE DOOR SEAL LWR AFT CORNER RETAINER FOUND CORROSION DAMAGE AT DOOR FRAME LWR AFT PAN SECTION. (C-CHECK) RO 7/10/2020 REMOVED CORROSION DAMAGE FROM SERVICE DOOR LWR AFT FRAME PAN SECTION REF SRM. OSDR SWAA2020070891428Beam · crackedDURING COMPLETION OF CCN: 14079 FOUND FORWARD SERVICE DOOR NR 5 (UPPER) BEAM TO BE CRACKED IN THE RADIUS ON THE INBOARD SIDE COMMON TO THE FORWARD MOST ATTACH POINT FOR THE DOOR HANDLE BOX ASSEMBLY. FORWARD SERVICE DOOR NR 5 (UPPER) BEAM WAS REMOVED & REPLACESDR SWAA2020070891427Beam · crackedDURING COMPLETION OF CCN: 14079 FOUND FORWARD SERVICE DOOR NR 4 (LOWER) BEAM TO BE CRACKED IN THE RADIUS ON THE INBOARD SIDE COMMON TO THE FORWARD MOST ATTACH POINT FOR THE DOOR HANDLE BOX ASSEMBLY. FORWARD SERVICE DOOR NR 4 (LOWER) BEAM WAS REMOVED & REPLACESDR SWIA2020071451294Retainer · corrodedSERVICE DOOR: LOWER SEAL RETAINER IS CORRODED. (C-CHECK) RO 7/10/2020 REMOVED CORROSION DAMAGE FROM SERVICE DOOR SILL LWR AFT CORNER RETAINER REF SRM. BLENDED AREA FOUND TO BE OUT OF LIMTS REF SRM. INSTALLED NEW SVC DOOR SILL LWR AFT RETAINER ANGLE P/N 6041SDR SWIA2020071451293Angle · corrodedSERVICE DOOR INTERNAL STRUCTURE: CLIP INSIDE LIGHTENING CUT-OUT JUST AFT OF THE INNER HANDLE ACCESS AREA HAS CORROSION. (C-CHECK) RO 7/10/2020 BLENDED CORROSION, REF SRM. FOUND TO BE OUT OF LIMITS. FABRICATED AND REPLACED ANGLE CLIP, P/N: 601R38304-49 REF DSDR R61A2020061000524Disk · puncturedAFT R2 SERVICE DOOR NO PRESSURE, BURST DISK PUNCTURED. R&R AFT R2 DOOR DIAPHRAGM, SERVICED DOOR REF AMM 52-42-53.SDR SWAA2020060890391Handle · looseF/A REPORTED R1 SVC DOOR HAD A LOOSE HANDLE. RE-SECURED R1 SERVICE DOOR HANDLE PER AMM 52-11-31, OPS CHECK GOOD.SDR SWAA2020072197422Beam · crackedCRACK FOUND AT R1 SERVICE DOOR STRUCTURE UPPER BEAM PN 141A6536-15 AT THE I/B FASTENER ADJACENT RADIUS / REMOVED AND REPLACED BEAM PN 141A6536--15 AT R1 DOOR STRUCTURE UPPER AREA PER REF. B737 DWGS 141A6516 AND 141A6535; NEW BEAM INSTALLED P.N 141A6536U21SDR SWAA2020060389012Handle · looseASSIST HANDLES LOOSE AT L-1 DOOR AFT OF DOOR, ON R-1 DOOR AND ON G-1 GALLEY. TIGHTENED ASSIST HANDLES AT L-1 DOOR AFT OF DOOR ON R-1 DOOR AND ON G-1 GALLEY IAW AMM 25-21-31-420-802 STEP 3B(6), AMM 52-41-31-400-802 STEP 3F(2) AND CMM 25-31-03 STEP 2A.SDR SWAA2020062988363Door · abnormalR1 DOOR WAS SAGGING. REMOVED THE R1 DOOR IAW AMM 52-41-00-00-801, REPLACED THE GUIDE ARM IAW AMM 52-41-21-400-801, REPLACED UPPER AND LOWER BEARING PLATES IAW SRM 51-40-02-0G-0, INSTALLED R1 DOOR IAW AMM 52-41-00-400-801, AND ACCOMPLISHED ADJUSTMENT IAW ASDR R61A2020060100502Cable · brokenR2 DOOR ARMING LEVER CABLE BROKE. R & R R2 DOOR ARMING LEVER CABLE.SDR GR4D20200527001Jackshaft · crackedWHEN CLOSING MED ACTUATOR BELL CRANK BEARING SHEARED.
Back to JASC 5240