Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201603301120Skin · dentedAFT STAB COMPARTMENT DOOR SKIN DENTED, 3" FROM THE EDGE OF THE DOOR. COMPLIED WITH EA F-5200-T0323638. MAJOR REPAIR.SDR C77A20160328002Gusset · gougedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF GOUGE DAMAGE TO THE R2 DOOR INTERNAL GUSSET PLATE. THE APPROX DAMAGE DIMENSIONS ARE AS FOLLOWS, 1.2 INCH X .5 INCH TO A MAX DEPTH OF .017 INCHES DEEP. RECEIVED A PERMANENT SDR UHLA201603240149Lock · dirtyR1 DOOR DIFFICULT TO ARM. FOUND DIRT AND DEBRIS IN DOOR FLOOR LOCK MOUNT. CLEANED AS REQUIRED, OPS CHECK GOOD.SDR A6WA2016032543729Handle · failedSERVICE DOOR WILL NOT OPEN FROM OUTSIDE. CLEANED AND LUBRICATED SERVICE DOOR OUTER HANDLE, NO FIX. APPEARS HANDLE BINDING ON INNER SLEEVE. REPLACED OUTER HANDLE AND ANCHOR ASSY, REF CMM 52-41-01, OPS CHECK GOOD. THIS CLEARS MEL.SDR GTIA2016032201492Bottle · low pressureR1 DOOR SLIDE ASSIST BOTTLE PRESSURE BELOW LIMITS. SERVICE R1 DOOR SLIDE ASSIST BOTTLE TO PROPER LIMITS.SDR ASOA2016032214637Seal · dirtySERVICE DOOR WOULD NOT OPEN FROM OUTSIDE. OPENED DOOR, CLEANED SEALS & OPS CK IAW AMM 52-41-00.SDR ASAA2016032016034Door · out of sequenceR2 DOOR WILL NOT CLOSE PROPERLY AND IS NOW JAMMED. ACFT GROUNDED. FOUND DOOR OUT OF SEQUENCE. RESEQUENCED DOOR, DOOR OPERATES NORMALLY AND NO FAULTS FOUND.SDR DALA2016032102216Seal · dirtyTOP OF 4R DOOR FROZEN WITH ICE INTERIOR. PERFORMED INSPECTION OF 4R DOOR. CLEARED DEBRIS FROM SEAL AREA. CHECKED OPERATION OF 4R IAW AMM 52-11.SDR A6WA201643707Handle · out of adjustUNABLE TO OPEN SERVICE DOOR FROM OUTSIDE, DOOR OPENS FROM THE INSIDE NORMALLY. ADJUSTED SERVICE DOOR HANDLE, OUTER LOCK PIN & SECURED HANDLE IAW AMM 52-41-03, OUTER HANDLE OPERATIONS CHECKED GOOD.SDR MASA2016031812834Bottle · low pressureR2 DOOR PNEUMATIC PRESSURE ASSY FOUND 850 PSI BELOW SERVICEABLE LIMITS IAW MM 52-00-00.SDR MASA2016031812833Bottle · low pressureR1 DOOR PNEUMATIC PRESSURE ASSY FOUND 850 PSI BELOW SERVICEABLE LIMITS IAW MM 52-00-00 MO55, CREATED FOR GVI AFTER 24 HRS. 2X NRS CREATED FOR SERVICING AND GVI FROM 24 HRS AFTER SERVICING, SUBMITTING SUPPLEMENTAL INFORMATION FOR CLOSING C/A FOR PREVIOUSLY SUBSDR IPXA2016041001923Doubler · corrodedINSPECTION TYPE:C3, R-3 DOOR INTERNAL DOUBLER HAS CORROSION BETWEEN BS 1240 TO BS 1305, LONGERON 11R TO 15R. REPAIRED CORRODED R-3 DOOR INTERNAL DOUBLER BETWEEN BS 1240 TO 1305 LONGERON 11R TO 15R IAW EA 011-5330-01-A6161, REV I/R AND EO 5330-60274-A,SDR R61A201603100215Skin · chafedDURING HEAVY CHECK, INTERIOR SKIN STRUCTURE OF FWD SERVICE DOOR IS CHAFED. MX BLENDED TO ALLOWABLE LIMITS COMPLIED WITH ETD 2016-170-025146.SDR A6WA201643688Latch · dirtyPILOT REPORTED SERVICE DOOR DIFFICULT TO OPEN. HANDLE WAS DIFFICULT TO MOVE. DOOR TRAVELED FREELY ONCE HANDLE RELEASED. CLEANED, LUBRICATED & ADJUSTED INNER HANDLE LATCH ASSEMBLY IAW AMM 52-41-00. OPERATIONS CHECKED GOOD.SDR R61A201603070209Gusset · chafedMAJOR REPAIR DURING HEAVY CHECK WAS REPORTED THAT FWD E-BAY PLUG FWD RT GUSSET CHAFED. MAINTENANCE R & R FWD E-BAY PLUG FWD RT GUSSET IAW SRM 51-40-02, 51-41-01. PN 170-11682-001 GUSSET. AIRCRAFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.SDR GTIA2016030701479Bottle · low pressureR1 DOOR DAMPER REQUIRES SERVICING. SERVICED R1 DOOR DAMPER IAW AMM 52-22-00.SDR QXEA2016031400176Channel · corrodedEDGE CHANNEL ON AFT SERVICE DOOR CORRODED. REPLACED IAW SRM 53-40-21, SRM 51-24-35, REPAIR-01 AND DWG. 85339543, REV-A.SDR SWAA2016030849754Angle · corrodedR2 DOOR Z ANGLE CORRODED, BETWEEN BS 947 - 992.8. R & R Z ANGLE IAW SRM.SDR IPXA2016040601727Beam · chafedINSPECTION TYPE: 3C, R3 DOOR HAS CHAFE DAMAGE ON NR 7 BEAM, AFT SIDE ACCOMPLISHED BLEND REPAIR ON R3 DOOR NR 7 BEAM AFT SIDE IAW EA 011-5200-01-A6165, REV I/R AND EO 5210-60286-A.SDR IPXA2016040601726Beam · chafedINSPECTION TYPE:3C, R3 DOOR HAS CHAFE DAMAGE ON BEAM NR 7 ACCOMPLISHED BLEND REPAIR ON R3 DOOR NR 7 BEAM IAW EA 011-5200-01-A6165, REV I/R AND EO 5210-60286-A.SDR R61A201603040194Nut · corrodedDURING HEAVY CHECK, WAS REPORTED AFT SERVICE DOOR STOPS 4 ADJUSTMENT, NUTS RUSTED. MAINTENANCE R & R AFT SERVICE DOOR STOPS 4 ADJUSTMENT NUTS IAW AMM 51-42-03, PN NAS509-7, NUTS.SDR Y2PA20160304006Cusp Web · corrodedDURING C-CHECK FOUND THE LOWER CUSP OF THE R1 DOOR HAD MINOR CORROSION NEAR THE FORWARD EDGE AT FLOOR LEVEL THAT WAS BLENDED TO REMOVE CORROSION. A REPAIR WAS DONE IAW J2 ENGINEERING, INC. DOCUMENT J2R-0023,
REV IR DATED 22 FEB 2016, FAA APPROVAL.SDR QXEA2016030300171Seal · lack of lubeAFT SERVICE DOOR IS DIFFICULT TO OPEN. CLEANED AND LUBED THE DOOR SEAL AND SURROUND AREA. DOOR OPENS SMOOTHLY AND NO DEFECTS NOTED. RETURNED TO SERVICE.SDR N6WA2016030301Trim Panel · detachedSERVICE DOOR TRIM DETACHED. SECURED TRIM ON SERVICE DOOR IAW AMM 25-26-07.SDR REXA2016022900346Plate · corrodedSERVICE DOOR STEP PLATE IS BENT & HAS CORROSION ALONG THE BOTTOM EDGE. LOCATED & DRILLED NEW SERVICEABLE STEP PLATE IAW SRM 51-40-11-001-001-A01, PN SH670-31407-7.SDR IPXA2016030100162Bottle · low pressureDURING PDC, FOUND EMERGENCY ESCAPE BOTTLE OF DOOR R1 PRESSURE LOW. R1 DOOR EMERGENCY ESCAPE BOTTLE SERVICED IAW AMM 12-25-04, PB 301, REV 84.04, DATED 02/25/16.SDR GTIA2016022901477Seal · leakingBUZZING SOUND FROM R2 DOOR IN FLIGHT. PERFROMED TSM 52-13-00-810-826-A AND FOUND DEBRIS ON DOOR SEAL. REMOVED DEBRIS FROM SEAL. NO DEFFECT NOTED.SDR REXA2016022600356Intercostal · damagedAFT EQUIPMENT BAY DOOR INTERNAL INTERCOSTAL IS BENT & DAMAGED. REPLACED AFT EQUIPMENT BAY DOOR INTERNAL INTERCOSTAL IAW SRM 51-42-06 & 51-40-11.SDR FDEA201602240682Door · crackedR4 LOWER CORNER HAS CRACK. REMOVED CRACK & INSTALLED DOUBLER.SDR GTIA2016022201472Seal · leakingPULSING AIR SOUND NEAR R2 DOOR IS STILL THERE. STARTS IN CLIMB AROUND 4.0 PSI AND STOPS AROUND 7.3 DIF PRESSURE IN DESCENT IT STARTS IMMEDIATELY AND IS LOUDER THAN LAST FLIGHTS WRITE UP. PERFORMED OPS CHECK OF THE MANUAL MODE SELECT AND MANUAL MODE PRESSURE SDR MASA2016022212787Handle · bindingSERVICE DOOR DIFFICULT TO OPEN. CLEANED, LUBED AND ADJUSTED SERVICE DOOR HANDLE. OPS NORMAL.SDR DALA2016022901486Beam · crackedLOWER BEAM CRACKED ON R-1 SERVICE DOOR AT LOWER END BELOW BEAM ATTACH FITTING REPAIR, REPLACE BEAM REF ORNRC 64480-0800-0029. REMOVED AND INSTALLED NEW Z FRAME IAW SRM 51-40-02, PAR 6 AND DWG 591084.SDR SWIA201641976Cover Plate · corrodedSERVICE DOOR ENTRY COVER PLATE CORRODED AT FASTENER HOLES. SERVICE DOOR SILL PLATE REPLACED IAW SRM.SDR REXA2016021700243Striker · corrodedSERVICE DOOR SEAL STRIKER IS CORRODED AT LOWER EDGE. CONTINUATION CARD 81517711 OP 191. R & R SERVICE DOOR SEAL STRIKER, PN SH670-31412-7 TO REPAIR CORROSION IAW MWC 81517711 OP 116 & 191 FOR DETAIL OF WORK PERFORMED.SDR A6WA201643597Shaft · damagedUNABLE TO OPEN SERVICE DOOR FROM OUTSIDE. DISASSEMBLED OUTER SERVICE DOOR HANDLE & INSPECTED IAW SUP 11-029B. MINOR DAMAGE ADDRESSED ON OUTER HANDLE SHAFT & ASSEMBLY. LUBRICATED & REASSEMBLED IAW AMM SUPP 11-029B.SDR SWAA2016021849194Link · brokenR1 DOOR UPPER HINGE LINK GUIDE ARM ATTACH FITTING BROKEN. R & R HINGE LINK IAW AMM.SDR ASAA2016021615488Guide Arm · out of adjustR1 DOOR DOES NOT CLOSE WITH EXCESSIVE FORCE. ACFT GROUNDED. ADJUSTED R1 DOOR GUIDE ARM AND VERIFIED PROPER LATCHING OF DOOR FROM INTERIOR HANDLE AND EXTERIOR HANDLE TO BE SATISFACTORY IAW AMM 52-41-00.SDR SWAA2016030749690Structure · corrodedR1 DOOR INNER CHORD CORRODED, BETWEEN BS 294 - 332. R & R INNER CHORD IAW SRM.SDR R61A201602110176Skin · corrodedDURING HEAVY CHECK, FWD SERVICE DOOR INTERIOR SKIN STRUCTURE IS CORRODED. MAINTENANCE R & R INTERIOR SKIN STRUCTURE IAW SRM 51-41-01, 51-42-03.SDR UHLA201602090092Skin · gougedGOUGE FWD SERVICE DOOR INTERIOR SKIN STRUCTURE. REMOVED DAMAGED GUSSET PLATE FROM INTERIOR DOOR STRUCTURE. LOCATED AND DRILLED NEW GUSSET PLATE, REF SRM 51-40-01, 51-43-05. INSTALLED NEW GUSSET PLATE ON INTERIOR DOOR STRUCTURE AT FWD SERVICE, REF SRM 51-41-SDR REXA2016020800244Angle · corrodedSERVICE DOOR LOWER SILL MOUNT ANGLE IS CORRODED. R & R MOUNT ANGLE WITH NEW PN SH670-31996-3 IAW SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01.
SDR R61A201602050132Screw · corrodedDURING HEAVY CHECK, AFT SERVICE DOOR STOP 2ND FROM BOTTOM FWD SIDE HARDWARE CORRODED. MAINTENANCE R & R AFT SERVICE DOOR STOP 2ND FROM BOTTOM FWD SIDE HARDWARE IAW AMM 52-43-23, PN 170-68172-001, SCREW.SDR SWIA201641864Seal · leakingWHILE CLIMBING, ACFT WAS PRESSURIZING NORMAL AND AT 32,000 FT CREW REPORTED VERY LOUD NOISE COMING FROM SERVICE DOOR. THEN CABIN PRESSURE STARTED TO CLIMB UNTIL IT REACH 8000. CREW STARTED TO DESCEND AND CABIN ALT KEPT CLIMBING UNTIL REACHED 11,000 FT THEN CRSDR 39LA20160204151Access Panel · missingTHE FLIGHT CREW, DURING POST FLIGHT INSPECTION, DISCOVERED THAT THE AFT LT TRANSMISSION OIL COOLER ACCESS PANEL WAS MISSING.SDR UHLA201602030056Gusset · damagedGOUGE AFT SERVICE DOOR INTERIOR STRUCTURE FWD UPPER CORNER. R & R GUSSET PLATE ON AFT SERVICE DOOR INTERIOR STRUCTURE FWD UPPER CORNER REF SRM 51-41-01, 51-43-01.SDR SWAA2016020448667Support Frame · crackedR1 DOOR HANDLE TORQUE BOX LOWER SUPPORT FRAME CRACKED AT LOWER INBOARD FORWARD ATTACH BOLT. R&R DOOR PER AMM.SDR DALA2016020300819Frame · damagedR1 INSIDE DOOR AT BOTTOM OF DOOR AT 2ND BAY FOUND DAMAGE ON THE MIDDLE OF FRAME. SUMMARY OF 63853-0800-0035: SRM 51-41-00, P1 ITEM 2. REPAIRED DAMAGED AREA IAW SRM 51-70-11 REPAIR 201. REINSTALLED LOWER SILL LINKAGE ROD IAW AMM 20-50-01-911-801.SDR A6WA201643518Service Door · lack of lubeSERVICE DOOR WILL NOT OPEN FROM OUTSIDE. INSPECTED SERVICE DOOR OUTER HANDLE & LUBRICATED IAW SUPP 11-029B. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20160128020Beam · crackedSERVICE DOOR LOWER BEAM CRACKED AT AFT END. SEE NRTC E491285 FOR CORRECTIVE ACTION. ENTIRE BEAM IS BEING REPLACED UNDER THAT NRTC.SDR CALA2016020100077Door Frame · crackedR1 DOOR FRAME BELOW THE BOX HANDLE MECHANISM, BOLT ATTACHMENT HOLE, JUST AFT OF DOOR TORQUE TUBE HAS A CRACK ALTER ACFT NOSE. R & R BEAM IAW SRM 51-40-02 & DWGS 141A6535 & 141A6516.
Back to JASC 5240