SDR CALA2021080401245Door · missingPDA 1 LAVATORY TOILET SERVICE DOOR MISSING FROM ACFT UPON ARRIVAL EXAMINED ACFT FOR DMG FROM PART DEPARTING ACFT. NO DAMAGE NOTED. NEEDS NEW DOOR AND HARDWARE. REFERENCE IPC 52-49-07-01 ITEMS 55, 60, 65, 70, 75 & 230. UPDATED MATERIALS LIST. PLACAED ON CDL 52DSDR AALA202107262143Access Door · missingAIRCRAFT WAS NOT GROUNDED: ON ARRIVAL INTO PHL THE LAVATORY SERVICE DOOR 171AL WAS FOUND TO BE MISSING. **SUPPLEMENTAL REPORT FOR AALA202107212143: INSTALLED SERVICE DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-42-13: ** (CLOSED)SDR AALA202107212143Access Door · missingAIRCRAFT WAS NOT GROUNDED: ON ARRIVAL INTO PHL THE LAVATORY SERVICE DOOR 171AL WAS FOUND TO BE MISSING. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR CALA2021063001003Service Door · missingPDA 2 THE TOILET SERVICE DOOR WAS REPORTED MISSING BY RAMP AND HAS BEEN ASSESSED TO BE A CATEGORY 2 PDA. NO SUBSEQUENT DAMAGE TO AC. LOCAL OPS ADVISED TO PERFORM FOD CHK OF TAXI AND RUNWAYS. ITEM WAS PLACE ON CDL 52D AND A/C WAS DISPATCHED. DURING A CK OF HISDR REXA2021080600528Door · unsecurePOTABLE WATER SERVICE DOOR AT FS349 IS HITTING THE FUSELAGE AND GOUGING IT. 900-53-900-105 - REWORK AREA IAW EANO. CRJ953-11796 REV IR ISSUE 6-19-21SDR CALA2021050500601Latch · looseVIBRATION FELT BY F/A IN AFT GALLEY WHILE CLIMBING THRU FL 240. VIBRATION FELT IN FLOOR FROM GALLEY UP TO WINGS AS WELL AS IN FIRST CLASS . DID NOT FEEL IN FLIGHT DECK OR CONTROLS. VIBRATION WENT AWAY DESCENDING THRU 10,000 FT AND SLOWING FROM 250 TO 210 CREW SDR DALA2021042102327Support · corrodedSHIP 672 CORROSION ON SUPPORT OF FWD LAVATORY ACCESS DOOR LH SIDE. CORRECTIVE ACTION: SUMMARY: OF NRC 00184 SUPPORT OF FWD LAVATORY ACCESS DOOR LH SIDE WAS REPAIRED PER ER/A 591134-14 REV ORIGINAL AND ETI-57-21-141 REV 2. (1787238)SDR R61A2021051200393Door · corrodedCORROSION FOUND ON AFT WASTE DOOR INTERNAL SURFACE AND MIDDLE STIFFNER. AFT WASTE DOOR REPLACED IAW AMM 53-03-60-440-801-A SUB TASK 440-002-A.SDR DALA2021041902284Angle · out of limitsDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 4 EA LAV SERVICE DOOR LATCH ANGLES OUT OF LIMITS. REPLACED LATCH. (LP 1783497)SDR CALA2021031900333Access Door · missingPDA 1 CLEANING CREW REPORTED AFT LAV SERVICE DOOR MISSING AT ARRIVAL TIME AT B TERMINAL PART INFO AND PHOTOS PLACED ITEM ON CDL DOOR MISSING, FOUND NO OTHER DAMAGE AT THIS TIME, ALL ATTACHING HARDWARE MOST BE REPLACED.SDR JR2R20210125173Door · corrodedLAV WASTE DOOR CORRODED.SDR ASAA2021012233937Door · missingGROUND CREW REPORTS LAV PANEL MISSING ON ARRIVAL SAN. GROUNDED-YES. CONDITIONAL INSPECTION C/O, PER B737-900 AMM TASK 05-51-59-960-001, NO DAMAGED NOTED TO SURROUNDING SERVICE LAV DOOR AREA. FOUND ONLY PAINT SCRATCHES AT FWD BOTTOM OF LAV SERVICE DOOR SURROSDR SWAA2021051340190Service Panel · corrodedTOILET SERVICE PANEL 145AL INNER SURFACE PREVIOUS REPAIR BETWEEN HINGES HAS MISSING PAINT AND POSSIBLE CORROSION. / REMOVED TOILET SERVICE PANEL 145AL AND REPLACED WITH NEW PANEL IAW SRM 51-40-02; AMM 52-49-07-000-801; AMM 52-49-07-400-801. OHMS CHECK GOOD. 59SDR R61A2020123100945Skin · corrodedWHILE AC WAS IN FOR HEAVY CHECK FOUND WASTE SERVICE DOOR INT AND EXT SKIN CORROSION. REPLACED SERVICE DOOR PN 170-86668-403, IAW AMM 20-10-01, FOR DETAILS OF WORK PERFORMED SEE AAR NRC 45000827-1000-0005. AC REMAINS IN YQG FOR COMPLETION.SDR DALA2020120303953Structure · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON INTERNAL STRUCTURE OF MID LAVATORY SERVICE DOOR PANEL NR 121AL AT LOWER FUSELAGE ACP600- 100-02Z (FUS). REPAIRED PER ERA.SDR R61A2020121500870Stiffener · corrodedCORROSION FOUND ON WASTE ACCESS DOOR STIFFENER. AAR REPALCED THE STIFFENER ON NRC 4500812-1000-003, PER ARM 51-41-02. THIS AIRCRAFT HAS BEEN RETURNED TO SERVICE.SDR SWAA2021072030789Structure · corrodedLAV SERVICE DOOR HAS CORROSION AROUND BONDING JUMPER STUD ON DOOR SIDE / FOUND CORROSION ON LAV SERVICE DOOR OUT OF LIMITS; ORIGINAL THICKNESS .060; REMOVED .020 MATERIAL 1' X 1'; OUT OF LIMITS PER SRM 52-40-01-1A-4; SRM 52-40-01-0I4. REMOVED CORRODED DOOR PERSDR SWIA202054656Diaphragm · corrodedWHILE REMOVING FRAME SECTOR AT FS 379.00 FOUND CORROSION ON WATER WASTE SERVICE DOOR LOWER DIAPHRAGM P/N SH670-32284-3. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW SERVICABLE DIAPHRAGM ON LOWER FWD WATER WASTE DOOR SURROUND STRUCTURE, REF DWG AND CRJ 70SDR FDEA202011052774Door · corrodedBELOW L2 DOOR THE LAV SERVICE DOOR DOUBLER IS CORRODED. REMOVED CORROSION, IAW B757 CPM 20-40-00, MATERIAL REMOVED .002 FROM .071, EVALUATED AREA FOUND TO BE LESS THAN 10% WITHIN LIMITS, IAW B757 SRM 53-00-01-1A. ALODINED AREA, IAW B757 SRM 51-20-01-OG. PRISDR ASAA2020102733419Door · detachedF/A REPORTS NOISES UNDER THE L2 DOOR. FOUND LAV WASTE SERVICING DOOR MISSING LEAVING DAMAGE. GROUNDED-YES. INSTALLED REPLACEMENT LAV SERVICE DOOR, REF B737-900 AMM 52-49-07.SDR SWAA2021080924608Door · corrodedEXTERIOR LAV SERVICE DOOR HAS CORROSION ON THE INTERNAL SIDE OF DOOR AROUND THE BONDING JUMPER STUD / FOUND CORROSION ON INTERNAL SIDE OF THE EXTERIOR LAV SERVICE DOOR TO BE OUT OF LIMITS; ORIGINAL THICKNESS 0.100; REMOVED 0.040 MATERIAL PER SRM 52-40-01-0I-4;SDR R61A2020102200697Door · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION ON AFT FUSELAGE WASTE SERVICE PANEL. AFT FUSELAGE WASTE SERVICE PANEL REPLACED, IAW AMM 20-10-01-910-001-A. A/C REMAINS IN CHECK.SDR 6PMR302201780002Door · corrodedREPAIR: POTABLE SERVICE DOOR HAS CORROSION UNDER AFT LATCH. CORRECTIVE ACTION: REMOVED AND REPLACE POTABLE WATER SERVICE DOOR, IAW B767-3 AMM 52-49-03.SDR R61A2020092000635Skin · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION ON WASTE SERVICE PANEL SKIN BETWEEN FR 88-89 CFIII. REPLACED AFT SERVICE DOOR PANEL BETWEEN FR 88-89, IAW EMB 170 SRM 51-41-02.SDR SWIA202052741Door · corrodedFORWARD WASTE WATER DOOR CORROSION UNDER THE LOWER DOOR HINGE HALF ON THE FUSELAGE DOWN TO THE BOTTOM OF THE WASTE WATER CUT OUT AREA, MARKED & FLAGGED. C-CHECK RO 9/21/2020. REMOVED CORROSION ON FWD WASTE DOOR UNDER LOWER DOOR HINGE HALF ON THE FUSELAGE DOWSDR SWIA202081751826Skin · corrodedWASTE SERVICE DOOR SKIN IS CORRODED. REMOVED AND REPLACED PANEL WASTE SERVICE DOOR , REF. AMM.SDR SWIA2020090952401Hinge Arm · corrodedLAV SERVICE DOOR (196AR) HINGES ARE CORRODED AND MISSING PAINT. C-CHECK RO 9/5/2020. REMOVED UNSERVICEABLE LAV SERVICE DOOR (196AR) HINGES AND INSTALLED SERVICABLE LAV SERVICE DOOR (196AR) HINGES, IAW CRJ-200 SRM.SDR SWAA2021081374491Door · corroded'CORROSION' L/H FUSELAGE @ STA 867 - ST 887 TOILET SERVICE DOOR INTERNAL SURFACE HAS CORROSION IN SEVERAL AREAS. (18-004) / REMOVED CORROSION AT TOILET SERVICE DOOR INTERNAL SURFACE FOUND TO BE OUT OF LIMIT (CORROSION THROUGH) IAW SRM 51-10-02-0G-0 & 52-40-01-SDR CALA2020041700839Door · missingPDA 1 LAV SERVICE DOOR COMPLETELY MISSING - PART DEPARTED AIRCRAFT (PDA). PHOTO ADDED - PART DEPARTED AIRPLANE (PDA) REQUEST DEFERAL PER CDL 52D. DISPATCH DESK: 90 NAME: GP DATE: 13-APR-20- TOMC APPROVED. PDA TO BE COMPLETED BY IAH. CDL APPLIED.SDR FDEA2020040870709Stiffener · corrodedLAVATORY SERVICE DOOR STIFFENER IS CORRODED (119AL) REMOVED AND REPLACED LAVATORY SERVICE DOOR STIFFENER PER BAC DWG #141N8631 REV F AND B757 SRM 51- 40- 02 TOPCOATED AREA PER B757 SRM 51-20-01SDR 2020F00158Service Panel · corrodedAIRBORNE/PEMCO NON-ROUTINE 2387N375 DISCREPANCY: FWD FUSELAGE WATER DRAIN SERVICE PANEL CORRODED. CORRECTIVE ACTION: REPAIRED FWD FUSELAGE WATER DRAIN SERVICE PANEL IAW AMES EA47359REA14.SDR REXA2020041300442Hinge · corrodedINITIAL INSPECTION: CORROSION ON HINGE FITTINGS AND HINGES OF THE LAVATORY WASTE SERVICE PANEL NBR 196ER (SM) (FUS)
SUMMARY OF NRC 00047: HINGE FITTINGS AND HINGES OF THE LAVATORY WASTE SERVICE PANEL NBR 196ER WERE REPLACE PER CRJ/900 AMM 52-45-01-400-801-A01SDR SWIA2020040149829Cover · corroded* THE AFT POTABLE WATER HANDLE COVER HAS CORROSION AND CHAFFED. (MARKED) (C-CHECK) RO:3/29/2020REMOVED CORRODED AND CHAFED AFT POTABLE WATER HANDLE COVER AND LOCATED DRILLED AND INSTALLED NEW AFT POTABLE WATER HANDLE COVER P/N: SH670-37612-1, P/O: T5SDR DALA2020022871483Latch · damagedCORROSION LEVEL: 2 WASTE WATER SERVICE PANEL 163AL LATCHES DAMAGED CORROSION FOUND IN AREAS AROUND LATCHES, REMOVED CORROSION 0.020 REMAINING OF 0.140 FOUND TO BE OUT OF LIMITS. REPLACED LATCHES. (LP 1506309)SDR CALA2020021700455Panel · corrodedB737-53-3-0725: CORROSION AROUND TOILET SERVICE PANEL. REF BY PEMCO NR 2675N757. REMOVED AND EVALUATED CORROSION AT SKIN AROUND TOILET SERVICE PA NEL. ORIG MAT .080 MAT LOSS .024'' MAT REMAING .056 MAT LOSS ALLO WABLE .10T FOUND TO BE OUT UNIT PERFORMED SKIN RSDR 120B202002140015Seal · missingFWD F1 LAVATORY WASTE DOOR MISSING UPPER AND LOWER SEALS.SDR 120B202002140014Seal · missingFWD F1 LAVATORY WASTE DOOR MISSING UPPER AND LOWER SEALS.SDR SWIA2020033049727Spring · brokenFUELING ACCESS DOOR 162AB LATCH HAS A BROKEN SPRING. (C-CHECK) RO:3/26/2020REMOVED AND REPLACED LATCH IAW CRJ-200 SRM.SDR SWIA2020033049726Hinge · brokenFUELING ACCESS DOOR 162AB UPPER HINGE HOLD-OPEN TRIGGER IS IN OP AND INNER SPRING IS BROKEN. (C-CHECK) RO:3/26/2020REMOVED BROKEN ACCESS DOOR HINGE AND REPLACED WITH NEW HINGE IAW CRJ-200 SRM.SDR CALA2020020300319Latch · brokenPDA 1 RIGHT WING FUELLING DOOR PUSH TAB MISSING FROM MIDDLE LATCH. PART 1 , INTERIM REPAIR ACCOMPLISHED PER ECRA 5249-01143. CHECK EACH FLIGHT REQUIRED. CARRIED FOR FIVE (5) FLOGHT CYCLES. REF ECRA 5249-01143 PART 1, 6. REPAIR OR REPLACE THE LATCH WITHIN 5 SDR SWIA202002048210Door · corrodedCORROSION IN LAV. SERVICE DOOR INTERNAL/EXTERNAL SIDES. (C-CHECK) RO 2/02/2020 REMOVED AND REPLACED LAV. SERVICE DOOR REF AMM. ASSET # EAMS 7400 CAL DUE 4-10-20.SDR QXEA2020011500025Access Door · detachedRAMP REPORTS WASTE SERVICE ACCESS DOOR FELL OFF, REMOVED FROM SERVICE. PLACED ON CDL C-53-03-02 FOR DOOR 152AR. RETURNED TO SERVICE.SDR AALA2020011439056Latch · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY SERVICE PANEL ACCESS DOOR AFT LATCH. REPLACED LATCH PER SRM 51-40-02.SDR NACA2019123040145Door · corrodedAFT PORTABLE WATER DOOR SHOWS EVIDENCE OF CORROSION. REPLACED AFT TOILET SERVICE DOOR WITH NEW IAW AMM 52-49-07, REV 90. BONDING CHECK SERVICEABLE.SDR SWIA2020011447662Service Door · corrodedCORROSION ON INTERNAL SURFACE OF LAV. SERVICE DOOR. (C-CHECK) RO 1/11/2020 REMOVED CORROSION ON INTERNAL SURFACE OF LAV. SERVICE DOOR. DOOR NOMINAL: 0.050". MAX. MATERIAL REMOVED: 0.005". NON SIG ALLOWABLE: 0.001". REMAINING MATERIAL: 0.045". LAV. SERVICE DOOSDR R61A202001040012Door · corrodedCORRODED WASTE SERVICE DOOR 152AR REMOVED AND REPLACED WASTE SERVICE DOOR PANEL 152AR PN: 170-86668-403 REF EMB SRM 53-03-60 AND RESTORE SURFACE REF EMB SRM 51-23-04, 51-23-05 & 51-23-06.SDR DALA2019121607368Door · inflt separationPDA. PART DEPARTED AIRCRAFT. A/C 3144 CLOSED LOG 6089545 FLT/CHK 1426 PILOT REPORT. REFUEL PANEL DOOR BELLY FAIRING MOUNTED*** MISSING **** FWD TO CDL 28-00-02B. PERFORMANCE CORRECTIONS APPLY. PRIOR TO EACH DEPARTURE, VISUALLY INSPECT SPEED TAPE TO VERIFY THATSDR AALA2019122399033Door · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON MID LAVATORY SERVICE DOOR AT BS 71 AND S22L. REPLACED MID LAVATORY SERVICE DOOR PER AMM 52-10-02.SDR SWIA2020012147852Hinge · broken* RE FUEL DEFUEL DOOR HAS BROKEN UPPER HINGE. (C-CHECK) RO:1/17/2020REMOVED AND INSTALLED NEW REPLACEMENT LATCH ON REFUEL/DEFUEL DOOR WITH REPLACEMENT FASTENERS REF CRJ200 SRM AND REF CRJ200 SRM. ELECTRICAL BONDING TEST GOOD.SDR SWAA2022032551664Door · corroded***CORROSION*** ON TOILET SERVICE DOOR 145AL AT BONDING JUMPER LOCATION / REMOVED CORROSION FROM TOILET SERVICE DOOR AT BONDING JUMPER FOUND OUT OF LIMITS; REMOVED AND INSTALLED NEW TOILET SERVICE DOOR; PERFORM BONDING TEST AND FIT CHECK WAS GOOD; APPLIED CIC;