JASC 5246

Service difficulty reports · 697

Reports filed under 5246 · Fluid Service Doors, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5246'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA2019102606228Door · missingWASTE WATER SERVICE DOOR - AFT DOOR MISSING MEL NUMBER ADDED FOR DISPATCH RELEASE, LOG REDEFERRAL REQUIRED. (5486248)Oct 25, 2019 · N928DN · Doug MD9030SDR AALA201910239001Access Door · missingAIRCRAFT WAS GROUNDED: UPON ARRIVAL AT MAN; THE HYDRAULIC SERVICE PANEL WAS FOUND TO BE MISSING. THE PANEL HINGES WERE SHEARED , SERVICING HOSE WAS FOUND LOOSE, THE RAT PANEL WAS FOUND TO BE CRACKED AND A MARK WAS NOTED ON THE RIGHT SIDE OF THE FUSELAGE. SUPPLOct 21, 2019 · N395AN · Boeing 767323SDR AALA201910219035Hinge · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LAVATORY SERVICE PANEL FORWARD HINGE AT BS 847 AND S25. REPLACED HINGE PER SRM 51-10-02.Oct 17, 2019 · N857NN · Boeing 737823SDR SWAA2022032259499Door · corrodedCORROSION - FOUND CORROSION ON WASTE SYSTEM SERVICE DOOR AT BONDING JUMPER ATTACHMENT / REMOVED CORROSION ON WASTE SYSTEM SERVICE DOOR AT BONDING JUMPER AS PER B737-700 SRM 51-10-02-0G-0; FOUND TO BE OUT OF LIMITS AS PER B737-700 SRM; ORIG MAT : .060' ; MAT REOct 16, 2019 · N909WN · Boeing 7377H4SDR COEA2019110763810Door · corrodedWO 205731 NR 200005 HEAVY CHECK COE/MINOR REPAIR: POTABLE WATER SERVICE DOOR HAS LEVEL 2 CORROSION ON EXTERIOR AND INTERIOR SURFACES. CORRECTIVE ACTION: REPLACED DOOR WITH OEM PART.Sep 26, 2019 · N810HC · Aerosp ATR72212SDR SWAA2022031550271Door · corrodedLOWER FUSELAGE LAV SERVICE DOOR 145AL INNER SURFACE; INBD EDGE HAS CORROSION. / REMOVED AND REPLACED LAV SERVICE DOOR WITH NEW DOOR REF B737 AMM 52-49-02-00801; 52-49-07-400-801; 52-49 -07-000-802.Aug 21, 2019 · N449WN · Boeing 7377H4SDR DALA2019081904846Door · missingAFT WASTE SERVICE DOOR MISSING. INSTALLED NEW LAV SERVICE DOOR IAW AMM 38-30.Aug 6, 2019 · N909DE · Doug MD88SDR SWAA2022031441070Service Door · corroded***CORROSION*** ON TOILET SERVICE DOOR AROUND BUCK TAILS COMMON TO EXISTING REPAIR / CORROSION WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM FOR CORROSION COMMON TO A REPAIR REMOVED AND REPLACED TOILET SERVICE DOOR ASSY PER AMM 52-49-07-0Aug 5, 2019 · N419WN · Boeing 7377H4SDR CALA2019080501316Door · detachedPDA 2 POTATABLE WATER SERVICE DOOR MISSING. BROKE OFF, FOUND 2 PUNCTURES FORWARD OF PANEL. INSTALLED A NEW DOOR REFERENCE AMM B787-A52-40-12-OOA-720A-AAug 5, 2019 · N16008 · Boeing 78710SDR SWAA2022031432332Bracket · corrodedBRACKET ON POTABLE WATER SERVICE DOOR CORRODED. / REMOVED CORRODED BRACKET ON POTABLE WATER SERVICE DOOR AND INSTALLED REPLACEMENT BRACKET ITEM # 147A7221U42 IAW B737-700 SRM 51-40-02-0G-0 AND DWG # 147A7221 SHEET 26Jul 30, 2019 · N295WN · Boeing 7377H4SDR SWAA2022031432330Door · corroded***CORROSION*** POTABLE WATER SERVICE DOOR SURFACE CORROSION MULTIPLE AREAS / DAMAGE POTABLE WATER SERV. DR. FOUND TO BE OUT OF LIMITS IAW 52-40-01-1A-5 OF SRM. REMOVED MATRL AREA 10' X 8' X .040. REPAIRED DAMAGED AREA IAW ATS ER 19-04246 IR AND SWA EA 1-752-2Jul 29, 2019 · N295WN · Boeing 7377H4SDR R61A201907280775Access Door · corrodedDURING HEAVY MAINT CHECK FOUND- CORROSION ON WATER SERVICE ACCESS DOOR. REMOVED AND REPLACED WATER SERVICE DOOR REF AMM 53-03-62. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.Jul 28, 2019 · N127HQ · Emb ERJ170200LRSDR R61A201907280774Service Door · corrodedDURING HEAVY CHECK FOUND-CORROSION ON WASTE SERVICE DOOR FR88-89 ST26-28R. REMOVED AND REPLACED WASTE WATER SERVICE DOOR REF AMM 53-03-60. RESTORE SURFACE PROTECTION. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.Jul 28, 2019 · N127HQ · Emb ERJ170200LRSDR DALA2019073104498Door · missingPOTABLE WATER DOOR MISSING. REF LP 5476442. (LP #5476460)Jul 21, 2019 · N896AT · Boeing 717200SDR SWAA2022031182460Door · corrodedINNER SURFACE OF TOILET SERVICE DOOR IS CORRODED / REMOVED AND REPLACED CORRODED TOILET SERVICE DOOR PER AMM 52-49-07-000-801 AND AMM 52-49-07-400-801. BOND TEST OF JUMPER CHECKS GOOD AT .0005 OHMS 92982U 7/21/19Jul 20, 2019 · N749SW · Boeing 7377H4SDR R61A201907170759Door · corrodedDURING HEAVY CHECK MAINTENANCE FOUND WASTE SERVICE FUSELAGE DOOR HAS CORROSION AT HINGE AREA BONDING HOLE AND AT STIFFENER/ INTERCOSTAL. REMOVED AND REPLACED WASTE SERVICE DOOR REF: AMM 53-03-60/400, AMM 20-10-01. A/C REMAINS IN CHECK.Jul 17, 2019 · N652RW · Emb ERJ170100SESDR SWAA2022031282960Service Door · corrodedWASTE SERVICE DOOR (PANEL 145AL) INBOARD EDGE OF PANEL IS CORRODED. / REMOVED AND REPLACED CORRODED WASTE SERVICE DOOR PNL #145AC IAW 737 AMM 52-49-07.Jul 15, 2019 · N750SA · Boeing 7377H4SDR SWAA2022031240395Service Door · corrodedDOOR 145AL IS CORRODED AT THE GROUND STUD / REMOVED & REPLACED DOOR ASSY 145AL IAW SRM 51-40-02 & IPC 52-49-07-01 & AMM 52-49-07-400-801.Jul 14, 2019 · N417WN · Boeing 7377H4SDR SWAA2022031160554Service Door · corroded***CORROSION*** (MULTIPLE POINTS) ON TOILET SERVICE DOOR (145AL) - MARKED / REMOVED & REPLACED TOILET SERVICE DOOR (145AL) IAW AMM 52-49-07-400-801 59191U 01AUG19Jul 8, 2019 · N913WN · Boeing 7377H4SDR SWAA2022031109781Panel · corrodedWATER SERVICE PANEL 146AR HAS BUBBLING PAINT ON THE EXTERNAL SKIN (POSSIBLE CORROSION) / ACCOMPLISHED DETAILED DAMAGE REMOVAL; INSPECTION AND REPAIR INSTRUCTIONS TO WATER SERVICE DOOR 146AR IAW EA 1-752-2591 REV IR AND ATS ER 19-04209 REV IRJun 30, 2019 · N7835A · Boeing 737752SDR SWAA2022031033233Door · corroded***CORROSION*** WASTE SERVICE DOOR INNER SURFACE STA860 WL160 STR28L / CORROSION ON WASTE SERVICE DOOR AT STA860 WL160 STR28L FOUND TO BE OUT OF LIMITS IAW SRM 52-40-01-1A-4. INSTALLED REPLACEMENT WASTE SERVICE DOOR PO #749501 IAW AMM 52-49-07-400-801. BOND CHMay 30, 2019 · N298WN · Boeing 7377H4SDR SWAA2019062634166Skin · corrodedLOWER EXTERNAL FUSELAGE, POTABLE WATER DOOR SKIN CORRODED AROUND AFT LATCH. R & R SERVICE DOOR IAW SRM & DWG.May 25, 2019 · N738CB · Boeing 7377H4SDR SWAA2022030878924Door · corroded***CORROSION*** TOILET SERVICE DOOR INNER SURFACE CORRODED STA860 WL160 STR25L / REMOVED AND REPLACED TOILET SERVICE DOOR IAW AMM 52-49-07-000-801 STEPS 2C(1-2) AND IAW AMM 52-49-07-400-801 STEPS 3C1(D-F) BONDING CHECK GOOD. 56800U 04JUL19May 18, 2019 · N737JW · Boeing 7377H4SDR SWAA2022030826876Service Door · corrodedLAV SERVICE DOOR HAS SPOTS OF CORROSION INSIDE AND OUTSIDE OF DOOR / REMOVE & REPLACED LAV SERVICE DOOR IAW B 737-700 SRM 51-40-02-0G-0 DOOR REMOVED AND INSTALLED ON NRC X950524 REMOVED CORROSION ORIGINAL T .060' LOSS OF .030' REMAINING .030' FOUND TO BE OUT OMay 2, 2019 · N281WN · Boeing 7377H4SDR SWAA2022030848096Service Door · corrodedCORROSION ON THE INTERNAL SIDE OF LAV SERVICE DOOR AROUND BONDING JUMPER / EVALUATED CORROSION ON LAV SERVICE PANEL AROUND BONDING JUMPER; WAS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED PANEL IAW AMM 52-49-07-000-801 AND 52-49-07-400-801. BOND CHECK GOODMay 2, 2019 · N433WN · Boeing 7377H4SDR R61A201904230408Hinge · corrodedDURING HEAVY CHECK VISIT FOUND AFT LAV WASTE DOOR HINGE AND BONDING WIRE AREA IS CORRODED. REMOVED AND REPLACED AFT LAV WASTE DOOR HINGE, RESTORED PROTECTIVE FINISH REF EMB SRM 51-40-08 AND 51-23-00 ALSO REMOVED AND REPLACED BONDING WIRE OHM CHECK GOOD REF EApr 23, 2019 · N446YX · Emb ERJ170200LRSDR SWAA2022030704070Door · corroded***CORROSION*** WHILE REPLACING LAV SERVICES DOOR HINGES; DOOR PANEL WAS FOUND TO BE CORRODED THROUGH AT BONDING STRAP ATTACHMENT POINT. / CORROSION ON LAV SERVICE DOOR WAS FOUND TO BE OUT OF LIMITS REMOVED AND REPLACED LAV SERVICE DOOR WITH NEW ASSY. IAW AMM Apr 20, 2019 · N212WN · Boeing 7377H4SDR SWAA2022030727435Door · corrodedLAV SERVICE DOOR 145AL CORROSION AROUND GROUDING STUD FOR BONDING JUMPER. / REMOVED CORROSION ON LAV SERVICE DOOR; CORROSION OUT OF LIMITS; RECEIVED NEW PANEL P/N: 146A7410-6 TAG # XD0638; TREATED; PRIMED; TOP COATED; AND INSTALLED REF B737 SRM 51-40-02-0G-0.Apr 19, 2019 · N282WN · Boeing 7377H4SDR SWAA2022030445621Door · corroded***CORROSION*** TOILET SERVICE DOOR INNER SURFACE CORRODED STA860 WL160 STR25L / UPON EVALUATION OF THE WASTE TANK SERVICE DOOR FOUND DAMAGE OUT OF LIMITS; DAMAGE DIMENSIONS: L=2.2'; W=2.2'; D=0.08' I.A.W SRM 52-40-01-1A-4 FIG. 103; DETAIL 4; REMOVED AND REPLAMar 28, 2019 · N434WN · Boeing 7377H4SDR SWAA2022030336981Door · corroded***CORROSION*** ON INTERIOR TOILET SERVICE DOOR AT AROUND BONDING WIRE. STA 847-867 BETWEEN STR 23L AND 24L / CORROSION ON TOILET SERVICE DOOR FOUND TO BE OUT OF LIMITS IAW SRM 52-40-01-1A-4. REMOVED AND REPLACED TOILET SERVICE DOOR IAW AMM 52-49-07-000-801 ANMar 19, 2019 · N408WN · Boeing 7377H4SDR AALA201902269035Door · missingON ARRIVAL, THE REFUELER DOOR ASSEMBLY 192MB WAS FOUND TO BE MISSING. INSTALLED REFUEL DOOR ASSEMBLY (192MB) PER AMM 52-42-18.Feb 25, 2019 · N654AW · Airbus A320232SDR R61A2019020870165Door · corrodedDURING HEAVY CHECK MAINTENANCE FOUND WASTE SERVICE DOOR IS CORRODED. REMOVED AND REPLACED WASTE SERVICE DOOR. REF EMB AMM 53-03-60. A/C REMAINS IN CHECK.Jan 27, 2019 · N870RW · Emb ERJ170100SUSDR SWAA2019022830113Skin · corrodedTOILET SERVICE DOOR 145AL INBOARD EDGE OF DOOR SKIN CORRODED. R&R DOOR PER AMM.Jan 24, 2019 · N272WN · Boeing 7377H4SDR SWAA2022030264040Service Door · corrodedLAV SERVICE DOOR HAS CORROSION AT THE GROUNDING FASTENER / CORROSION ON LAV SERVICE DOOR FOUND OUT OF LIMITS OUT OF LIMITS DUE TO 100% MATERIAL LOSS AT GROUND PER SRM 52-40-01-1A-1. REMOVED AND INSTALLED NEW LAV SERVICE DOOR PO#724379 PER AMM 52-49-07-000-801 Jan 14, 2019 · N558WN · Boeing 73773VSDR SWAA2022030174232Service Door · corrodedWATER SRVICE DOOR PANEL HAS CORROSION AT FWD HINGE (INTERNAL SURFACE) / ORIGINAL WATER SERVICE DOOR PANEL HAS 100% MATERIAL LOSS AT FWD HINGE POINT. VERIFIED NEW DOOR; 147A7221-43; IAW BOEING DWG #147A7221 REV. D APPLIED FINISHES TO NEW DOOR IAW AMM 51-21-41; Jan 3, 2019 · N727SW · Boeing 7377H4SDR SWAA2022030134628Skin · corroded***CORROSION*** TOILET SERVICE DOOR SKIN INTERIOR LOWER SURFACE STR 847+10 LBL27 6' BELOW STRINGER 24 / REMOVED CORRISION ON TOILET SERVICE DOOR INTERRIOR SKIN 3.7'L X 2.4'W X .045D FOUND TO BE OUT OF LIMITS 52-40-01-1A-4. REMOVED AND REPLACED LAV SERVICE DOORDec 26, 2018 · N402WN · Boeing 7377H4SDR DXTA2018122701830Door · detachedLAV DOOR CAME OFF INFLIGHT. BOTH PILOTS CHECKED THAT IT WAS SECURELY CLOSED WITH ALL 3 LATCHES CLOSED AND KEY LOCKED PRIOR TO ENGINE START. CES SCREEN ALSO SHOWED ALL ACCESS DOORS CLOSED PRIOR TO FLIGHT. REMOVED & REPLACED SERVICE DOOR IAW CL-650 SRM 51-54Dec 26, 2018 · N216QS · Cndair CL6002B16SDR REXA2018122191297Channel · corrodedFWD LAV SERVICE DOOR 142BR ACCESS LOWER CHANNEL PAINT BUBBLED REMOVED/REPLACED IMPACT ANGLE IAW CRJ 900 SRM 51-42-06. REMOVED CORROSION IAW CRJ 900 SRM 51-21-06. APPLIED FINISH IAW CRJ 900 SRM 51-25-16 Dec 9, 2018 · N901XJ · Cndair CL6002D24SDR QXEA2018120300443Latch · unsecureFULING ON CAUTION ILLUMINATED ON TAKEOFF ROLL. REJECTED TAKEOFF AND RETURNED TO GATE. REMOVED FROM SERVICE. PERFORMED GVI OF REFUEL/DEFUEL PANEL DOOR FOUND DOOR NOT FULLY LATCHED. LATHCED DOOR PROPERLY. FUELING CATION NO LONGER ILLUMINATED NO FURTHER DEFECTS NDec 2, 2018 · N400QX · Bombdr DHC8402SDR HNAA2018120500302Switch · malfunctionedPDIS 640 52-40 1720451 30NOV18 CLT CLOSE FUEL DOOR OPEN EICAS IN FLT DOOR FOUND TO BE CLOSED FACT 30NOV18 05:01 ROA R/R'D FUELING DOOR MICRO SWITCH PER MM 52-78-01, OPS CK GOOD.Nov 30, 2018 · N640AE · Emb EMB145LRSDR SWAA2022022896289Panel · corroded***CORROSION*** PANEL 146AR (WATER SERVICE PANEL) INNER SURFACE LEADING EDGE CORRODED / REMOVED & REPLACED PANEL #146AR (WATER SERVICE PANEL) PER SRM 51-40-02-0G AND BOEING DRAWING 147A7221. PERFORMED BOND CHECK; CHECK GOOD IAW BOEING DRAWING 147A7221Nov 29, 2018 · N7741C · Boeing 7377BDSDR SWAA2022022520517Door · corrodedTOILET SERVICE DOOR 145AL HAS CORROSION BELOW BONDING WIRE END. / REMOVED AND REPLACED TOILET SERVICE DOOR 145AL PER AMM 52-49-07. FIT CHECK GOOD.Nov 23, 2018 · N263WN · Boeing 7377H4SDR AALA201811219001Access Panel · missingAIRCRAFT ARRIVED AT GATE WITH THE LAV ACCESS PANEL DOOR MISSING AND THE LAV FLAPPER VALVE HANGING OPEN. CLOSED FLAPPER VALVE AND INSTALLED NEW ACCES PANEL DOOR IAW AMM 52-49-07.Nov 19, 2018 · N933AN · Boeing 737823SDR DALA2018111706702Door · corroded(LOG 0829332) DURING INSPECTION FOUND CORROSION ON TOILET SERVICE DOOR (INTERNAL) AT FUSELAGE. CORROSION LEVEL 2.- TOILET SERVICE DOOR WAS REPLACED PER B737-800 SRM 51-40-02.Nov 16, 2018 · N3734B · Boeing 737832SDR R61A2018111641146Service Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND AFT FUSELAGE WASTE SERVICE PANEL CORRODED AROUND GROUNDING STRAP ATTACH POINT. REMOVED AND INSTALLED WASTE SERVICE PANEL 170-86668-403 IAW EMB AMM 53-03-60.Oct 30, 2018 · N638RW · Emb ERJ170100SESDR SWAA2022022421204Door · corrodedLAV SERVICE DOOR HAS CORROSION AT BONDING WIRE ATTACH FASTENER / CORROSION AT BONDING WIRE ATTATCH FASTENER OUT OF LIMITS; DAMAGE OVER FASTENER HOLE PER SRM 52-40-01-1A-4. REMOVED AND REPLACED LAV DOOR PER AMM 52-49-07-000-801 AND AMM 52-49-07-400-801. BONDINGOct 23, 2018 · N265WN · Boeing 7377H4SDR SWAA2022022318660Service Door · corroded***CORROSION*** ON LAV SERVICE DOOR PANEL 145AL ALONG INBOARD EDGE AND AFT EDGE AND AROUND AFT LATCH / CORROSION ON LAVATORY SERVICE DOOR PANEL 145AL OUT OF LIMITS DUE TO CORROSION NOT MAINTAINING 20X DISTANCE AWAY FROM HOLES PER AMM 52-40-01-1N-4. REMOVED ANDSep 8, 2018 · N259WN · Boeing 7377H4SDR SWAA2022022318661Service Door · corroded***CORROSION*** ON WATER SERVICE DOOR PANEL 146AR AROUND LATCHES / REMOVED CORROSION; FOUND OUT OF LIMITS IAW SRM 52-40-01-1A-5. REMOVED & REPLACED WATER SERVICE DOOR PANEL & CHECKED BONDING IAW AMM 52-49-09-400-801 59191U 02OCT18. BOND CHECK GOOD IAW AMM 52-4Sep 8, 2018 · N259WN · Boeing 7377H4SDR SWAA2022022220808Door · corroded***CORROSION*** TRANSFERRED FROM LOGBOOK PAGE #0743907 'AFT LAV SERVICE DOOR EVIDENCE OF CORROSION' / REMOVED CORRODED AFT LAV SERVICE DOOR + REPLACED WITH NEW AFT LAV SERVICE DOOR MPN 52410001-01 IAW AMM 52-49-07-400-801 + 52-49-07-000-802Aug 29, 2018 · N264LV · Boeing 7377H4SDR SWAA2022022251368Door · crackedPOTABLE WATER EXTERNAL DOOR AFT MOUNTING BRACKET BROKEN -( DOOR REMOVED ) ( WATER SVC DR RMVD- POTABLE WATER COMPRESSOR INOP MEL 38-1 ) / CLOSING ACTION #0149707 INSTALLED NEW POTABLE WATER ACCESS DOOR PER AMM 52-49-09. SEE LOG PAGE #0149708 FOR MEL 38-1-02 CLAug 5, 2018 · N8656B · Boeing 7378H4
Back to JASC 5246