What was found
***CORROSION*** ON TOILET SERVICE DOOR 145AL AT BONDING JUMPER LOCATION / REMOVED CORROSION FROM TOILET SERVICE DOOR AT BONDING JUMPER FOUND OUT OF LIMITS; REMOVED AND INSTALLED NEW TOILET SERVICE DOOR; PERFORM BONDING TEST AND FIT CHECK WAS GOOD; APPLIED CIC; IAW SRM 52-40-01-1A-4; AMM 52-49-07-000-801; AMM 52-49-07-400-801 AMM 52-49-07-000-802; SOPM 20-41-05 88415U 14DEC19