JASC 5246
Service difficulty reports · 697
Reports filed under 5246 · Fluid Service Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201808170873Door · corrodedWASTE SERVICE DOOR AT THE REAR FUSELAGE AREA HAD CORROSION ON THE INSIDE OF THE DOOR WHERE BONDING WIRE ATTACHES. REMOVED AND REPLACED WASTE SERVICE DOOR IAW SRM 51-42-08.SDR SWAA2022021717614Door · corrodedCORROSION ON LAV SERVICE DOOR INTERIOR AND EXTERIOR SIDES / REMOVED CORROSION 1' X 4' X .040'; ORIGINAL THICKNESS .100'. REMAINING THICKNESS .060' FOUND TO BE OUT OF LIMITS PER SRM 52-40-01-1A-4. REMOVED AND REPLACED LAV SERVICE DOOR WITH NEW CFE 7523161-DOOR SDR R61A201808170880Door · corrodedCORROSION ALONG THE HINGE LINE TO WASTE WATER SERVICE DOOR. REMOVED AND REPLACED WASTE SERVICE DOOR IAW AMM 53-03-60, AND SRM 51-23-06.SDR SWAA2022022116338Door · corroded***CORROSION*** WASTE WATER SERVICE DOOR HAS CORROS ION / REMOVED WASTE WATER SERVICE DOOR IAW AMM 52-49-07-000-801 AND REPLACED WITH NEW SERVICE DOOR IAW AMM 52-49-07-400-801 ITEM # 7520429 PO # 697271 56844U 7/16/18 BONDING CHECK GOODSDR SWAA2022022117866Service Door · crackedPANEL 145AL; TOILET SERVICE PANEL; AFT HINGE BRACKET CRACKED AIRCRAFT SIDE. / REMOVED AND REPLACED WITH NEW FROM STOCK TOILET SERVICE PANEL PER AMM 52-49-07.SDR SWAA2022022117863Service Door · corrodedPANEL 145AL; TOILET SERVICE PANEL; FWD HINGE BRACKET CORRODED DOOR SIDE. / REMOVED AND REPLACED WITH NEW FROM STOCK TOILET SERVICE PANEL PER AMM 52-49-07.SDR SWAA2022022117864Service Door · corrodedPANEL 145AL; TOILET SERVICE PANEL; AFT HINGE BRACKET CORRODED DOOR SIDE. / REMOVED AND REPLACED WITH NEW FROM STOCK TOILET SERVICE PANEL PER AMM 52-49-07.SDR SWAA2022022117865Service Door · crackedPANEL 145AL; TOILET SERVICE PANEL; FWD HINGE BRACKET CRACKED AIRCRAFT SIDE. / REMOVED AND REPLACED WITH NEW FROM STOCK TOILET SERVICE PANEL PER AMM 52-49-07.SDR SWAA2022022117820Service Door · corrodedWASTE TANK SERVICE PANEL DOOR HAS CORROSION ON BOTH HINGES / REMOVED AND REPLACED WITH NEW FROM STOCK TOILET SERVICE PANEL PER AMM 52-49-07.SDR SWAA2022021716042Panel · corroded***CORROSION*** AT TOILET SERVICE DOOR PNL# 145AL GROUND ATTACH POINT AND FWD I/B CORNER / REMOVED PANEL 145AL PER AMM 52-49-07-000-801 INSTALLED PLACKARD ON REPLACEMENT 145AL PANEL PER SOPM 20-50-05 INSTALLED REPLACEMENT 145AL PANEL PER AMM 52-49-07-400-801 PSDR SWAA2022021462676Door · corroded***CORROSION*** LAVATORY SERVICE DOOR IS CORRODED AT BONDING JUMPER ATTACH LUG. / REMOVED CORROSION ON LAVATORY SERVICE DOOR AT BONDING JUMPER ATTACH POINT. FOUND TO BE OUT OF LIMITS DUE TO CORROSION COMMON TO FASTNER HOLE PER SRM 52-40-01-1A-4. REMOVED AND INSDR SWIA201844786Hinge · corrodedLAVATORY SERVICING DOOR HINGE HAD CORROSION. REMOVED AND REPLACED THE HINGES IAW SRM.SDR SWAA2022021615094Door · corroded***CORROSION*** TOILET SERVICE DOOR HAS CORROSION (PITTING) AROUND GROUND STUD FASTENER HOLE / TOILET SERVICE DOOR WILL BE REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0. REMOVED AND REPLACED TOILET SERVICE DOOR IAW AMM 52-49-07-000-801 AND AMM 52-49-07-400-801SDR SWAA2022021614587Service Door · corroded145AL TOILET SERVICE DOOR HAS CORROSION ON INTERNAL SIDE / REMOVED AND REPLACED 145AL TOILET SERVICE DOOR ASSY PER IPC 52-49-07-01 SRM 51-40-02-0G-0 AMM 20-10-14 AND AMM 52-49-400-801. RESISTANCE CHECK GOODSDR SWAA2022021587673Service Door · corrodedCORROSION ON LAV SERVICE DOOR INTERIOR AND EXTERIOR SIDE / CORROSION ON LAV SERVICE DOOR SKIN FOUND TO BE OUT OF LIMITS; CAN'T MAINTAIN 20X MINIMUM DAMAGE FROM HOLES PER SRM 52-40-01-1A-4. 4.B (1). REMOVED AND INSTALLED NEW DOOR ASSEMBLY PER AIPC 52-49-07-01; SDR R61A2018050100548Door · corrodedMAINTENANCE FOUND CORROSION ON WASTE SERVICE DOOR. THE DOOR WAS REMOVED AND REPLACED IAW SRM 53-03-60.SDR SWAA2022021043433Door · corroded***CORROSION*** WHILE WORKING; NOTED LAVATORY SERVICE DOOR; CORROSION COMMON TO JUMPER ATTACH POINT. / REMOVED CORROSION AROUND LOADING JUMPER HOLE ON LAV SERVICE DOOR 1'X 1' X .050'; FOUND TO BE OUT OF LIMITS; ORIGINAL THICKNESS. .060'; PER SRM 52-40-01-1A-4.SDR O2MA180314 45551Door · damagedON LANDING, DISCOVERED FUELING DOOR OPENED IN FLIGHT AND DAMAGED THE DOOR AND HINGE.SDR SWAA2022021114833Door · corroded***CORROSION*** LAV SERVICE DOOR HINGES ARE CORRODED / REMOVED AND REPLACED LAV SERVICE DOOR ASSY PER AIPC 52-49-07-01 & SOPM - 20-50-01; BONDING CHECK IS GOOD PER SWPM 20-20-00. FUNTION DOOR IS GOOD. 43046U 17MAR18 56090C 17MAR18SDR DALA2018030901539Doubler · damagedE/E BAY FWD LAVATORY SERVICING PANEL , CORROSION AROUND TUBE UNDER HEATING GASKET. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE SUPPORT & DOUBLER IAW SRM 51-40-02, PARA 4 & 9, AND DWG 141N8631, REV A.SDR SWAA2022021032180Service Door · crackedBOTH DOOR MOUNTED SECTIONS OF THE WASTE SERVICE PANEL-145AL HINGES ARE CORRODED AND DISINTEGRATING. / RAR TOILET SERVICE DOOR PER MM 52-49-07SDR DALA2018021700967Service Door · crackedAFT LAV SERVICE DOOR CRACK IN FUSELAGE. TRACKING FOR ACCOMPLISHMENT OF SECTION III: PERMANENT REPAIR PER ER/A 538941-14 REV B. FUSELAGE SKIN BELOW AFT LAVATIRY SERVICE PANEL WAS PERMANENT REPAIRED PER ER/A 538941-14 REV.C AND ETI 88-18-008 REV.2. (LP0226265)SDR SWAA2022021010850Door · corroded***CORROSION*** AT LAV SERVICE DOOR EXTERIOR SURFACE AROUND LATCHES / REPLACED LAV SERVICE DOOR IAW AMM 52-49-07-400-801 AND AMM 52-49-07-000-802SDR QXEA2018021300055Access Panel · missingHYDRAULIC SERVICE PANEL, ON LEFT SIDE OF THE LEFT NACELLE WAS FOUND MISSING. REMOVED FROM SERVICE. INSTALLED A NEW DOOR AND RETURNED TO SERVICE.SDR SWAA2022020991359Service Door · corroded***CORROSION*** LAV SERVICE DOOR CORRODED AT BONDING JUMPER / REPLACED LAVATORY SERVICE DOOR WITH SWA CFE SI # 7520429 PRE SWA IPC 52-49-07-01 AND SOPM 50-50-01 AND SRM 52-40-01-1A-4 92907U 21FEB18 CORROSION MEASURED 2' X 2' X 0.032' ORIGINAL THICKNESS 0.060' SDR R61A201802090137Door · corrodedDURING A HEAVY CHECK, MAINTENANCE FOUND CORROSION ON THE WASTE SERVICE DOOR. REMOVED AND REPLACED THE WASTE SERVICE DOOR.SDR R61A201801300124Hinge · corrodedMAINTENANCE FOUND CORROSION ON THE WASTE SERVICE PANEL DOOR HINGE. REMOVED AND REPLACED WASTE SERVICE DOOR HINGE IAW SRM 51-40-02.SDR R61A201801300123Access Door · corrodedMAINTENANCE FOUND CORROSION AT THE WASTE SERVICE PANEL DOOR. REMOVED AND REPLACED THE WASTE SERVICE PANEL DOOR.SDR SWAA2022020742511Door · corroded***CORROSION*** NOTED ON LAV SERVICE DOOR (145AL) INTERIOR SURFACE LOCAL TO BONDING JUMPER. / REMOVED AND REPLACED LAV SERVICE DOOR (145AL) IAW AMM 52-49-07-000-801 AND 52-49-07-400-801 BOND CHECK GOOD.SDR SWAA2022020828685Service Door · corrodedSUPPLEMENTAL INFORMATION: AFT LAV SERVICE DOOR HAS INTERGRANULAR CORROSION ON INNER SKIN. / REMOVED AND REPLACED DOOR ASSY PER SRM 51-40-02.SDR SWAA2022020710059Door · corroded***CORROSION*** LAVATORY SERVICE DOOR BONDING JUMPER ATTACH POINT CORRODED / LAVATORY SERVICE DOOR BONDING JUMPER ATTACH PAINT CORRODED. REMOVED 1'X3'X.025 AT GROUND HOLE LOCATION; FOUND TO BE OUT OF LIMITS. DAMAGE LESS THAN 20X FROM HOLE REMOVED AND INSTALLEDSDR DALA2017122008764Door · corrodedLAVATORY G WASTE SERVICE PANEL DOOR IS CORRODED. REMOVED AND REPLACED THE DOOR IAW SRM 51-40-02.SDR R61A201711290972Door · corrodedMAINTENANCE REPORTED LEVEL 2 CORROSION ON THE WASTE SERVICE DOOR. MAINTENANCE REMOVED AND REPLACED THE WASTE SERVICE DOOR IAW AMM 20-10-01, 11-21-03 & 51-24-06.SDR SWAA2022020453421Door · corrodedEXTERIOR LAV SERVICE DOOR HAS CORROSION ON INSIDE SURFACE / R&R LAV DOOR ASSY PER AMM 52-49-07SDR R61A201711280892Hinge · corrodedWASTE AND WATER ACCESS DOOR INTERNAL SIDE HAS CORROSION NEAR ATTACHMENT AREA, REMOVED AND REPLACED HINGE AND BONDING STRAP REF SRM 51-41-02, AND 51-43-04, AND AMM 20-10-01.SDR AALA20171111002Door · missingDECLARED EMERGENCY, DUE TO A TIRE PRESSURE INDICATION. UNEVENTFUL LANDING AND TAXIED TO GATE. MAINTENANCE EVALUATED INDICATION ISSUE, NO PHYSICAL DAMAGE TO TIRE. MAINTENANCE INSPECTED AND FOUND SPEED TAPE COVERING MISSING FUEL PANEL. REPLACED FUEL DOOR ON RIGHSDR DALA2017102707849Door · corrodedLOWER FUSELAGE MID LAVATORY SERVICE DOOR 121AL OUTER SURFACE HAS CORROSION. REMOVED & REPLACED THE LAV SERVICE DOOR IAW SRM 51-40-02.SDR DALA2017101807619Door · corrodedLOWER FUSELAGE FWD LAVATORY SERVICE DOOR 119AL OUTER SURFACE HAS CORROSION. REMOVED THE CORROSION WITH 100% MATERIAL LOSS. OUT OF LIMITS IAW SRM 52-40-01, FIG 101, DETAIL V. REMOVED AND REPLACED THE DOOR IAW SRM 51-40-02.SDR SWAA2022020221595Angle · corroded***CORROSION*** NOTED ON WATER SERVICE DOOR (146AR) FWD ANGLE / GUARD ASSY. / REMOVED CORROSION ON WATER SERVICE DOOR (146AR) FWD ANGLE/GUARD ASSY AREA OF .05 X .05 X .008 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE PER SRM REPAIRABLE BY REPLACEMENT RSDR JR2R20171006092Skin · corrodedFORWARD LAVATORY SERVICE DOOR EXTERNAL SKIN CORRODED BETWEEN SKIN AND INTERNAL DOUBLER. REPAIRED FWD LAV SERVICE DOOR FWD LOWER CORNER FUSELAGE CUTOUT IAW EA 25-2017-110.SDR SWAA2022020163767Service Door · corrodedLAVATORY SERVICE DOOR IS CORRODED AT BONDING JUMPER AND AFT LATCH / REMOVED LAVATORY SERVICE DOOR PER SRM 51-40-02 LEAD45 18SEP17 56708U INSTALLED A 7523161 NEW DOOR REPLACED AFT LATCH & BONDING JUMPER PER SRM 51-40-02 AMM 52-49-07-400-801 OHMS CHECK IS GOOD 5SDR DALA2017090806748Service Panel · corrodedCORROSION ON FWD, LOWER LATCH SETTLEMENT AREA ON CUT OUT AT THE AFT LAVATORY SERVICE PANEL. THE LAVATORY SERVICE PANEL WAS REPAIRED IAW ER/A 397822-14, MA REV B. (LP# 0203427)SDR AALA201708179018Service Door · departedDURING POST FLIGHT, OBSERVED THE NR 1 ENGINE OIL SERVICE DOOR MISSING FROM AIRCRAFT. AIRCRAFT WAS GROUNDED.SDR DALA2017081206163Door · corrodedBS 1315, STRINGER 20L, AFT LAV SERVICE DOOR CORRODED. REPAIRED IAW ERA 560718-14.SDR JGVR20170811001Door · corrodedFOUND CORROSION ON THE TOILET SERVICING DOOR. REPLACED DOOR IAW SRM 51-40-03.SDR SWAA2022012741226Service Door · corroded***CORROSION*** WASTE WATER SERVICE DOOR CORROSION ON SURFACE / CORROSION FOUND OUT OF LIMITS PER SRM 52-40-01-1A-4 REMOVED AND REPLACED NEW WASTE WATER SERVICE DOOR I-A-W 52-49-07-400-801; BOND CHECK FOUND OK. REFINISH TOP SURFACE PER AMM 51-21-99-300-801 PO SDR SWAA2022013197142Door · corrodedTOILET SERVICE DOOR HAS CORRODED HINGES. / REMOVED AND REPLACED TOILER SERVICE DOOR ASSY PER AMM 52-49-09.SDR SWAA2022013184254Door · corrodedLAV WASTE DOOR HAS CORROSION ON TOP EDGE AND INSIDE / REMOVED CORROSION AND VERIFIED LIMITS AT LAV WASTE DOOR (ORIGINAL T .100') (LOSS = .033') (REMAINING .067') OUT OF LIMITS IAW SRM 52-40-01-1A-4 STEP 4B FIG 103 DETAIL 1 ) REMOVED AND REPLACED LAV WASTE DOORSDR SWAA2022012664971Service Door · corrodedWATER SERVICE DOOR HAS CORROSION ON INNER SURFACE / REMOVED DAMAGED WATER SERVICE DOOR AND INSTALLED NEW SERVICEABLE WATER SERVICE DOOR IAW AMM 52-49-09.SDR FDEA201707051853Door · corrodedLAVATORY SERVICE DOOR, AFT RIGHT CORNER DELAMINATED AND HAS CORRODED. REMOVED AND REPLACED THE FWD LAVATORY SERVICE DOOR IAW SRM 51-40-02.
Back to JASC 5246