JASC 5300
Service difficulty reports · 8,206
Reports filed under 5300 · Fuselage Structure (General), newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20011620Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK 6 AT STATION 215-216. INSTALLED NEW SECTION OF SEAT TRACK FROM STATION 215-304 IAW SRM 53-05. (M)SDR USAA010995Frame · dentedCLT - FOUND FRAME DENT .5 INCH IN DIAMETER, BS 1500 ABOVE S26L. DAMAGED REMOVED, REPAIR DOUBLER INSTALLED PER EA 69860. (M)SDR USAA010978Frame · corrodedCLT - FOUND FRAME CORRODED .5 INCH HOLE AND .5 INCH CORRODED AREA, STATION 1420 BETWEEN STRINGER 26L AND 27L. DOUBLER INSTALLED PER EA 69860. (M)SDR USAA010993Clip · corrodedCLT - FOUND FRAME CLIP CORRODED 1 INCH BY 2.5 INCHES, BS 1480 BETWEEN STRINGER 26R AND 27R. LOWER FRAME SECTION REPLACED AND BRACKETS ADDED PER SRM 51-40-02. (M)SDR USAA010984Frame · dentedCLT - FOUND FRAME DENTED APPROX .5 INCH BY .125 INCH DEEP, BS 560 AT S24L. INSTALLED DOUBLER PER EA 85030. (M)SDR USAA010985Frame · gougedCLT - FOUND FRAME GOUGED .125 INCH, BS 560 AT S22 LEFT. DOUBLER INSTALLED PER EA NR 85030. (M)SDR USAA010982Frame · dentedCLT - FOUND FRAME DENTED .5 INCH BY .125 INCH DEEP, BS 660 AT S23L. REPAIR DOUBLER INSTALLED PER EA 69873. (M)SDR USAA010981Frame · dentedCLT - FOUND FRAME DENTED .5 INCH IN DIAMETER, STATION 1620 BETWEEN SR 25L AND 26L. DOUBLER INSTALLED PER EA 69860. (M)SDR USAA010988Frame · crackedCLT - FOUND FRAME CRACKED .5 INCH, STATION 1580. DOUBLER INSTALLED PER EA 69860. (M)SDR USAA010983Frame · dentedCLT - FOUND FRAME DENTED 1 INCH DIAMETER, BS 1540 2 INCH BELOW STRINGER 25R. REPAIR DOUBLER INSTALLED PER EA NR 69860 AND TR 53-60-01A. (M)SDR USAA010986Frame · dentedCLT - FOUND FRAME DENTED .5 INCH, BS 1540 AT S26L. DOUBLER INSTALLED PER EA NR 69860. (M)SDR USAA010980Frame · dentedCLT - FOUND FRAME DENTED .5 INCH IN DIAMETER, STATION 1520 ABOVE STRINGER 26L. REPAIR DOUBLER INSTALLED PER EA 69860. (M)SDR GAIA01263STFitting · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED CARGO TIE DOWN FITTING CRACKED BS 720A, LBL 24, LBL 24, WL 156, FORWARD CARGO PIT. ACCOMPLISHED CARGO TIE DOWN FITTING REPLACEMENT IAW B727 SRM 51-30-2. (M)SDR GAIA01264STAngle · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED FLOOR SUPPORT ATTACH ANGLE CRACKED AT BS 304-312, LBL 20 PLUS 30. ACCOMPLISHED FLOOR SUPPORT ATTACH ANGLE REPLACEMENT IAW B727 SRM 51-20-1 AND 51-20-2. (M)SDR GAIA01269STFrame · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED BS 400 FRAME CRACKED AND DENTED BETWEEN STRINGER 7-8R. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 53-10-4, FIG 1. (M)SDR GAIA01270STFrame · dentedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED BS 380 FRAME DENTED BETWEEN STRINGER 5-6I. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 53-10-4, FIG 2. (M)SDR GAIA01273STFrame · dentedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED BS 580 FRAME DENTED BETWEEN STRINGER 15 AND 16. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 51-40-3, FIG 1 AND 53-10-2, FIG 3. (M)SDR GAIA01274STFrame · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED BS 640 IS CRACKED AND ENTERED BETWEEN STRINGER 16 AND 17R. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 51-40-3, FIG 1 AND 53-10-2, FIG 3. (M)SDR GAIA01275STStringer · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED STRINGER 15 RIGHT IS CRACKED AT BS 720B PLUS 15. ACCOMPLISHED STRINGER REPAIR IAW B727 SRM 53-10-3, FIG 5. (M)SDR GAIA01276STStringer · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED STRINGER 15 LEFT IS CRACKED AT BS 720B PLUS 15. ACCOMPLISHED STRINGER REPAIR IAW B727 SRM 53-10-3, FIG 5. (M)SDR GAIA01277STFrame · dentedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED IN LOWER AFT CARGO, FRAME BS 950C HAS A DENT AT STRINER 26L. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 51-40-3 FIG 1 AND 53-10-2, FIG 5. (M)SDR GAIA01278STFrame · dentedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED IN LOWER AFT CARGO, FRAME BS 1110 HAS A DENT IN THE RADIUS ABOVE STRINGER 26L. ACCOMPLISHED FRAME REPAIR IAW B727 SRM 51-40-3, FIG 1 AND 53-10-2 FIG 5. (M)SDR GAIA01282STIntercostal · crackedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED INTERCOSTAL BETWEEN BS 360 AND 380 AT STRINGER 5R IS CRACKED ON FORWARD INBOARD END. ACCOMPLISHED INTERCOSTAL REPAIR IAW B727 SRM 51-40-3, FIG 1 AND 53-10-2, FIG 3. (M)SDR GAIA01287STSeat Track · corrodedDURING AN LTC INSPECTION AT FLIGHTSTAR, IT WAS DISCOVERED CORROSION ON SEAT TRACK BS 620-640 AND CHAFED BS 610-620 UNDER PALLET LOCK LOCATION RBL 45.50. ACCOMPLISHED SEAT TRACK REPAIR IAW B727 SRM 53-10-5 FIG 3. (M)SDR AALA20011631Longeron · crackedTUL - FOUND LONGERON 17 LEFT CRACKED AT STATION 237 BEHIND FRAME. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR PER SRM 53-02 FIGURE 18. (M)SDR USAA011069Frame · corrodedPIT - FOUND FRAME CORRODED 4 INCHES BY .500 INCHES CORRODED, FORWARD FUSELAGE DOOR FRAME BS 794 ABOVE S25R. CORROSION LEVEL 1, TASK NR C53-100-01. INSTALLED DOUBLER PER SRM 53-60-15 AND EA 71737. (M)SDR USAA010962Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED APPROXIMATELY 4 SQUARE INCH AREA, BS 376.7 TO 440 AT LBL 24.75 AND LBL 45.5. CORROSION LEVEL 1, TASK NR C53-221-03. REMOVED AND ERPLACED SEAT TRACK SECTIONS PER SRM 51-10-02. (M)SDR 2001UALA01643Seat Track · crackedSTA 1840 TO 1856 24" RBL SEAT TRACK OTBD FLANG CRACK. SUPPLEMENTAL DATA UPDATE MRR ENTERED IN ERROR SEAT TRACKS ARE NOT PSE'S.SDR USAA010973Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 2 INCHES BY 2 INCHES, STATION 377.7 LBL 24.75. CORROSION LEVEL 1, TASK NR C53-221-03. REPLACED SEAT TRACK PER SRM 51-30-01. (M)SDR USAA010972Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 2 INCH BY 2 INCH AREA, STATION 377.7 LBL 45.5. CORROSON LEVEL 1, TASK NR C53-221-03. REMOVED AND REPLACED SEAT TRACK PER SRM 51-10-00 AND 51-40-02. (M)SDR USAA010968Skin · puncturedCLT - FOUND SKIN PUNCTURED 1 INCH, STATION 438, BETWEEN STRINGER 19R AND 20R. PREVIOUSLY INSTALLED DOUBLER PER RM 53-00-01 FIG 208. (M)SDR USAA010967SkinCLT - FOUND SKIN HAS HOLE WITH DENT .250 INCH, BS 686, BETWEEN S21R AND 22R. DAMAGED REMOVED, INSTALLED DOUBLER AND FILLER PER SRM 53-00-01 FIG 203, AND 51-40-02. (M)SDR AALA20011586Stringer · corrodedTUL - FOUND STRINGER 29R CORRODED ON LOWER FLANGE AT STATION 998. INSTALLED NEW STRINGER SECTION WITH SPLICE PER SRM 53-10-3. (M)SDR AALA20011585Skin · corrodedTUL - FOUND LIGHT CORROSION AROUND FLAPPER DRAIN BETWEEN 28R AND BLO STATION 685. INSTALLED DOUBLER PER SRM 53-30-3 050 7075 T-6 9 INCH BY 9 INCH FOUR ROWS EACH SIDE .1875 RIVETS. (M)SDR AALA20011577Skin · corrodedTUL - FOUND CORROSION ON INTERIOR OF SKIN BETWEEN STATION 1148 AND STATION 1166 BETWEEN STRINGER 22L AND 23L. INSTALLED REPAIR DOUBLER PER ESO 11697 DATED JULY 27, 2001. (M)SDR ABXA010439Fitting · crackedFRAME TO HAT CHANNEL FITTING INBOARD VERTICAL LEG CRACKED AT STATION 600, LONGERON 29 LEFT. REPLACED FITTING IAW DC-9 SRM 51-30-5.SDR ABXA010438Fitting · crackedLOWER AFT INBOARD FITTING CRACKED AT 1041 BULKHEAD LEFT. REPLACED FITTING IAW DC-9 SRM 51-30-1 AND 51-30-5.SDR C2XA01BT146Intercostal · corrodedYUL---CO4372, DURING 1C INSPECTION YUL MAINTENANCE FOUNDINTERCOSTAL TO BE CORRODED BETWEEN FRAMES 27A AND 28A AT STRINGER(S) 19R AND 19L.....MAINTENANCE REMOVED AND REPLACED INTERCOSTAL WITH NEW PART IAW ATR42 SRM 51-25-01.SDR ABXA010597Finger Doubler · corrodedCOCKPIT FLOOR, STATION 10, THE RIGHT SIDE HAD CORROSION AROUND AND UNDER THE FINGER DOUBLER. INSTALLED NEW FINGER DOUBLER AND REPAIRED AREA IAW DC-8 SRM 51-1-8, 53-2-0, 51-1-21, 51-1-20D, DAC DWG. # 56I12298 AND REA D853-40886MR.SDR USAA010953Bulkhead · crackedPIT - FOUND BULKHEAD WITH THREE CRACKS 1 INCH EACH, BS 178 LBL/RBL 6 INCHES BELOW WL 207 AND BL0 WL 184. CUT OUT DAMAGED AREAS, INSTALLED DOUBLER AND FILLERS PER EO 5300V153. (M)SDR UIEA0192Frame · crackedDURIN HFEC INSPECTION PER AD 96-26-04 REFERENCE SB 747-53A2293 FOUND FRAME STATION 280 LEFT CRACKED AT TWO PLACES. EACH CRACK WAS APPROXIATELY .250 INCH LONG, ONE EMINATING FROM AN INSULATION BLANKET STUD MOUNTING HOLE, THE OTHER FROM A GUSSET FASTENER HOLE TSDR UIEA01093Frame · crackedDURING HFEC INSPECTION PER AD 96-26-04 REFERENCES SB 747-53A2293 FOUND FRAME STATION 320 RIGHT CRACKED AT AN INSULATION BLANKET STUD MOUNTING HOLE. REMOVED FRAME. REPLACED FRAME WITH P/N 65B07942-564 PER SB 747-53A2293 IAW SRM 51-30-02. (M)SDR RRXA11442Web · crackedDURING A MAINTENANCE VISIT FOUND WEB CRACKED AT STA 280 L21L TO L20L. *** CORRECTIVE ACTION *** FABRICATED AND INSTALLED REPLACEMENT PART PER DHSK 873948.SDR RRXA11441Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACKED FITTING AT STA 1200 L33R - L34R. *** CORRECTIVE ACTION *** REPLACED CRACKED FITTING AT STA 1200 L33R TO L34R PER DC8 SRM 53-2-0 FIG 20SDR RRXA11440Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON FRAME AT STA 70 BELOW CUSP FROM L21L TO L21R. *** CORRECTIVE ACTION *** REPLACED STA 70 FRAME BELOW CUSP FROM L21L TO L21R DUE TO CORROSION, REF DC8 SRM 51-1-21, 51-1-21D, 51-3-0, 51-9-0, 51-1-11, 53-2-5 AND SRO 8SDR RRXA11439Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON SEAT TRACK AT STA 46-330 LBL63. *** CORRECTIVE ACTION *** REPLACED CORRODED SEAT TRACK AT STA 160 LBL63 PER DC8 SRM 53-7-1 FIG 9 AND SRM 53-2-3 FIG 8A.SDR RRXA11438Frame · damagedDURING A MAINTENANCE VISIT FOUND FRAME AT STA 1140 L31L TO L34R WITH NUMEROUS MISDRILLED HOLES. *** CORRECTIVE ACTION *** REPLACED FRAME AT STA 1140 L31L TO L34R DUE TO MUMEROUS MISDRILLED HOLES PER DHSK 873-816SDR RRXA11436Web · damagedDURING A MAINTENANCE VISIT FOUND TORQUE BOX WEB IN C-PIT HAS LITE SURFACE CORROSION AND IS MIS DRILLED. *** CORRECTIVE ACTION *** FABRICATED REPLACEMENT PER DAC DWG 9754948 AND INSTALLED PER DC8 SRM 51-1-21 AND 51-1-20D STA 1180 L31RSDR COMA0160555Web · crackedCRACKS FOUND AT LEFT AND RIGHT LOWER SKIN ACCESS PANELS.REPAIRED CRACKS IN LEFT AND RIGHT LOWER ENGINE SUPPORT BEAM I/A/W REO 601R-53-61-366.SDR COMA0160528Web · crackedCRACK AT LOWER WEB OF ENGINE SUPPORT BEAM AT LEFT FWD INBD CORNER 2" IN LENGTH.REPAIRED DAMAGE I/A/W REO 601R-53-61-3666.
Back to JASC 5300