JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2024020600231Flange · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION FOUND AO FR 68RH HORIZONTAL FLANGE RADIUS AT STR22RH. CRACK LENGTH 300 INCH, AT AFT GALLEY AREA; REF AEM WO: 2023 362/1, NR 2023-741035. ACCOMPLISHED REPAIR ON HORIZONTAL FLANGE FR 68RH AT STR 22RH. PER JB EC: A24-111SDR YENA2024020600229Stop Fitting · crackedDURING HEAVY MAINTENANCE: FUSELAGE / REAR FUSELAGE / FR 68 RH & STR 22 / DOOR STOP FITTING #1 / RADIAL FLANGE FILLET RADIUS / CRACK DAMAGE - PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)SDR YENA2024020600228Stop Fitting · crackedDURING HEAVY MAINTENANCE: FUSELAGE / REAR FUSELAGE / FR 68 LH & STR 22 / DOOR STOP FITTING #1 / RADIAL FLANGE FILLET RADIUS / CRACK DAMAGE - PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)SDR DALA2024020301506Door Frame · corrodedCORROSION ON DOOR JAMB STA 951 TO STA 994 AT AFT CARGO COMPARTMENT. C2. SUMMARY OF NRC 00071: CORROSION LEVEL 2. PREVIOUS REPAIR SECTION OF DOOR JAMB STA 951 TO STA 994 AT AFT CARGO COMPARTMENT WAS REPLACED PER B717-200 SRM 53-20-15-2R PROCEDURE 7 REPAIR 7. (LSDR JJBA20240207018Support Frame · crackedCF1, CRACK FOUND ON MIDDLE STEP FRAME FLOOR STRUCTURE BTW FR 18-20. CF1, MIDDLE STEP FRAME STRUCTURE BTW FR 18-20 REMOVED AND REPLACED BY NEW ONESDR DALA2024020601582Service Panel · delaminatedLAV SERVICE PANEL - PROTECTIVE SEALANT DELAMINATING INSIDE LAV SERVICE PANEL. EVIDENCE OF CORROSION NOTED. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0259:2021-2015/005 00005 REPAIRED PER PRI 614826-14 REV. 0, REVSDR AALA202402018982Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING OPEN HOLE 3 AT FR 16 RIGHT AND DOOR STOP FITTING #1. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.SDR AALA202402012493Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAMING RIGHT HAND CONTINUITY FITTING BETWEEN FR 1 AND FR 2 AT Y0. REPLACED CONTINUITY FITTING PER EO 5319Y017-002.SDR QXEA2024013100025Beam · corrodedAFT CARGO DOOR CUTOUT LOWER BEAM FORWARD FINGER PLATE HAS CORROSION BETWEEN FRAMES 77-78 AT STRINGER 26R. REMOVED AND REPLACED AFT CARGO CUTOUT LOWER BEAM PLATE PER SRM 51-40-08.SDR CALA2024013100268Door Frame · gouged(B737-52-3-0727) L-1 DOOR, DOORFRAME GOUGED AT THE UPPER HINGE C UTOUT. TRANSCRIBED FROM HAECO GSO NRC# 9286609. REMOVED GOUGED FWD FRAME IAW B737-700 SRM 51-40-02. LOCATED, DRI CMM 52-16-12. HAECO GSO MECH V896596 INSP QC002 LLED AND INSTALLED NEW 141A6110USDR YENA2024013000169Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN BOTH FRAME SEGMENT (1) OF THE EMERGENCY EXIT HATCH DOOR 844 CRACK L= 0.380 IN; REF: ARM W/O 2023 363/1 N/R 2023-749600 ACCOMPLISHED REINFORCEMENT DOOR STRUCTURE MODIFICATION IAW EC A320-52-1144, R&R SEGMSDR YENA2024013000168Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN BOTH FRAME SEGMENT (1) OF THE EMERGENCY EXIT HATCH DOOR 834 CRACK L=0.300IN; REF: ARM W/O 2023 363/1 N/R 2023-749598 ACCOMPLISHED REINFORCEMENT DOOR STRUCTURE MODIFICATION IAW EC A320-52-1144, R&R SEGMENSDR YENA2024013000167Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN BOTH FRAME SEGMENT (1) OF THE EMERGENCY EXIT HATCH DOOR 833 CRACK L=0.375 IN; REF: ARM W/O 2023 363/1 N/R 2023-749595 ACCOMPLISHED REINFORCEMENT DOOR STRUCTURE MODIFICATION IAW EC A320-52-11444, R&R SEGMSDR YENA2024013000166Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN BOTH FRAME SEGMENT (1) OF THE EMERGENCY EXIT HATCH DOOR 843 CRACK L=0.365; REF: W/O 2023 363/1 N/R 2023-749593 ACCOMPLISHED REINFORCEMENT DOOR STRUCTURE MODIFICATION IAW EC A320-52-1144, R&R SEGMENTS IAWSDR YENA2024013000165Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 AT AFT GALLEY AREA (FR 68 LH STOP DOOR 1, INBOARD/ LOWER HOLE , DIRECTION OF CRACK IS 6 OCLOCK, LENGTH OF CRAC K IS: 0.118 INCHES APPROX); (RESOLVED ON W/O: 1256626 TASKCARD: NR-00011) REF: ARM W/O 2023 36SDR YENA2024013000164Door Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 AT AFT GALLEY AREA FR 68 RH STOP DOOR 1 I/B LOWER HOLE CRACK INDICATION IS 5 O'CLOCK, NENGTH OF CRACK IS .127 INCHES; (RESOLVED ON W/O: 1256626 TASKCARD: NR-00009) REF: ARM W/O 2023 363/1 N/R 2023-749785 PSDR AALA202402235887Door Frame · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON APU ENCLOSURE, DOOR SURROUND STRUCTURE LOWER CHORD BETWEEN BS 1092 AND BS 1143, S23L. INSTALLED REPAIR STRAP PER 351640.SDR JJBA20240207014Crossbeam · crackedNLG W/WELL, CRACK FOUND ON NLG FWD TOP CROSSBEAM. NLG W/WELL, NLG FWD TOP CROSSBEAM REMOVED FOR REPLACEMENT. NLG W/WELL, NLG FWD NEW TOP CROSSBEAM INSTALLEDSDR IPXA2024020697266Drain · damagedFUSELAGE DRAIN HOLES INSPECTION AND INSTALLATION AFT OF BS 1725.5 BETWEEN S-36L AND S-36RSDR DALA2024013001393Box Beam · corrodedSHIP 696 IN REFRENCE TO NRC 00446: CORROSION ON BOX BEAM ( 1EAS) BTW STA 700 TO 720 LBL 62 AT CAB PAX FLOOR STRUCTURE. CORRECTIVE ACTION: SUPPORT WAS FABRICATED PER DWG 143N5410-3 REV F. SUPPORT BTW STA 700 TO 720 LBL 65 WAS REPLACED PER B757-200 SRM 51-40-02 SDR YENA2024012900133Beam · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING] CORROSION ON LOWER BEAM AT AFT CARGO DOOR CUTOUT BTW FR-77/78; (RESOLVED ON W/O: 1267464 TASKCARD: NR-00114) REF TOMX WO#2452NR# 00209 SUMMARY: CORROSION ON LOWER BEAM AT AFT CARGO DOOR CUTOUT BTW FSDR NACA2024012600005Retainer · corrodedOVERWING ENERGENCY HATCH SEAL RETAINER HAS BEEN CORRODED AROUND LOWER PORTION OF THE DOOR. RH FWD(2415R). 1. CORROSION REMOVED. THE SEAL RETAINER AND LOWER PORTION WERE OVER LIMIT 2. CUT-OUT THE DAMAGED AREA AND MADE REPAIR PARTS AND INSTALL WITH SEALANT. 3. SDR NACA2024012600004Retainer · corrodedOVERWING ENERGENCY HATCH SEAL RETAINER HAS BEEN CORRODED AROUND LOWER PORTION OF THE DOOR. LH FWD(2414L). 1. CORROSION REMOVED. THE DOOR LOWER PORTION & SEAL RETAINER WERE OVER LIMIT. 2. CUT OUT THE DAMAGED AREA & MADE REPAIR PARTS AND INSTALL WITH SEALANT. PSDR NACA2024012600003Retainer · corrodedOVERWING ENERGENCY HATCH SEAL RETAINER HAS BEEN CORRODED AROUND LOWER PORTION OF THE DOOR. LH AFT(2403L). OVERWING EMERGENCY HATCH SEAL RETAINER HAS BEEN CORRODED AROUND LOWER PORTION OF THE DOOR, RH AFT (2404R). 1. CORROSION REMOVED. THE DOOR LOWER PORTION SDR R61A2024021500072Seal Rest · corrodedFWD CARGO AFT LOWER SEAL RETAINER FOUND CORRODED. MX REPLACED SEAL REST IAW AMM 21-10-01 TABLE 201 AND 206SDR R61A2024021500071Seal Rest · corrodedFWD CARGO FWD LOWER SEAL RETAINER FOUND CORRODED. MX REPLACED SEAL REST IAW AMM 21-10-01 TABLE 201 AND 206SDR JJBA20240205007Nut Plate · crackedCRACKS FOUND ON TOP OVERHEAD MIDDLE FRAME AROUND NUTPLATE ON WINDSHIELD SURROUND STRUCTURE COCKPIT AREA. TOP OVERHEAD MIDDLE FR AROUND NUTPLATE ON WINDSHIELD SURROUND STRUCTURE REPAIREDSDR DALA2024020301509Door Frame · damagedRAMP REPORTS DAMAGE TO AFT CARGO DOOR CUTOUT. FOUND DAMAGE OUT OF LIMITS. REMOVED DAMAGE PER B717 SRM 53-20-15-2R REPAIR 10 OPTION 2. FABRICATED, TREATED, & PAINTED REPAIR PARTS PER B717 SRM 53-20-15-2R-10 OPTION 2. INSTALLED PARTS -11 & -13 PER B717 SRM 53-20SDR AALA202401307666Screw · unsecureAIRCRAFT WAS NOT GROUNDED: CHRONIC REPETITIVE REPORTS FOR FLIGHT DECK DOOR DIFFICULT OPERATION. MAINTENANCE FOUND 4 SCRWS PROTRUDING OUT OF THE DOOR FRAME AND TIGHTENED THE SCREWS. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR DALA2024012901275Window Frame · crackedSHIP 3124 CRACK WAS FOUND IN HOLE #3 AT THE LH LATERAL SLIDING WINDOW FRAME UPPER ATTACHMENT. CORRECTIVE ACTION: REPAIRED PER ER/A 614131-14. (0173458)SDR SWI202403110199Frame Angle · corrodedRH FS379.00 FRAME REINFORCING ANGLE (PN: SH670-32119-1) CORRODED AT STR 23R. (C-CHECK RO 3/10/2024) REMOVED AND REPLACED UNSERVICABLE RH FS379.00 FRAME REINFORCING ANGLE (PN: SH670-32119-1) WITH NEW REF. DRWG SH670-32050 REV. J AND CRJ 700 SRM 51-42-06-001SDR SWIA2024031100125Window Frame · crackedRH WINDSHIELD POST IS CRACKED. (C-CHECK RO 3/10/2024) REMOVED AND INSTALLED NEW R/H WINDSHIELD SIDE POST CRJ 700 SRM 51-42-21-001-001-A01 AND DWG CC670-33055 REV. -F. LEAK CHECK GOOD. COMPLIED WITH TASK 51-900-1002-SKY.SDR AALA202401259042Pressure Plate · crackedAIRCRAFT IN BASE MAINTENANCE: ROTO PROBE INSPECTION DETECTED CRACK IN BOX BEAM PRESSURE PLATE FORWARD FASTENER HOLE BETWEEN FR 42 AND FR 43, BETWEEN -Y1292 AND -Y1650. REPLACED PRESSURE PLATE PER EO 5315Y066-002.SDR AALA202404269735Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAMING LEFT HAND CONTINUITY FITTING BETWEEN FR 1 AND FR 4 AT Y0. REPLACED CONTINUITY FITTING PER EA 351108.SDR AALA202404268326Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK WINDSHIELD RIGHT CENTER POST LOWER ATTACHMENT AREA UPPER AND LOWER RADII ARE CRACKED BETWEEN FR 2 AND FR 6. REPLACED WINDSHIELD FRAME PER EA 351108.SDR SWAA2024022244597Stub Frame · crackedCRACK ON STUB FRAME LOCATED ON CUTOUT OF FWD SERVICE DOOR LOCATED BTW BS294.5 TO BS312 AND STR8R 2024-68197 CRACK ON STUD FRAME LOCATED ON CUTOUT OF FWD SERVICE DOOR LOCATED BTW BS294.5 TO BS312 AND STR8R PASSENGER CABIN<[01] REPLACED STUB FRAME LOCATED ON CUTSDR SWAA2024022144356Doubler · crackedCUT OUT DIMENTION EXCEEDS SRM ALLOWABLE LIMITS FOR EXTERNAL GROUND POWER RECEPTACLE DOOR SURROUND<[01] C/W EA24-153-00280 (EA EA-GENERAL);[02] REO-G24879 C/W;[03] C/W EA24-153-00280 (EA EA-GENERAL) HAECO REO-G24879;[04] C/W EA24-153-00280 (EA EA-GENERAL)SDR ASAA2024012447751Crease Beam · corrodedUPON CLEAN FOR PREP TO CLOSE CABIN FLOORS FOUND R/H SIDE CREASE BEAM INNER CHORD CORRODED STA 787 TO 887. GROUNDED - YES. REPAIRED CREASE BEAM INNER CHORD IAW EA 900ER-53EA-26548W=1" O=.050" R=.038" L=.3" D=.012".SDR DALA2024012901289Door Frame · corroded(LOG 0169611) CORROSION AT R1 DOOR HAS CORROSION AT LOWER FWD AND AFT STOP FITTING HOLES. CORROSION ON R1 DOOR LOWER GATE FWD AND AFT STOP FITTING HOLES FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN SRM. REMOVED AND REPLACED R1 DOOR LOWER GATE ASSY PER BOEING SDR CALA2024012900236Window Frame · crackedFR4 WINDSHIELD CTR POST LOWER NODE LH IB HOLE HAS CRACK INDICA TION AT LOWER FACE EXTENDING FWD .020 PER HAECO LCQ N/R 9290577/ 42577 GEN BY V892444 SH INITIAL INSPECTION PER PART 2 OF THE LATEST REVISION OF ECRA REPEAT INSPECTION AT INTERVALS NOT TO EXCEED 61SDR AALA202401266292Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED DOOR STOP #7 UPPER INBOARD HOLE AT FR 16 RIGHT. REPLACED DOOR STOP #7 PER EA 349100SDR DALA2024032503746Access Door · missingSHIP 3319 FOUND GROUND YELLOW HYDRAULIC CONNECTION ACCESS DOOR MISSING. CORRECTIVE ACTION: REPLACED PANEL PER A330 AMM 52-42. (5602014)SDR DALA2024012200908Door Frame · crackedSHIP 3243 DISC: CRACK INDICATION FOUND OPEN HOLE ON DOOR STOP 7 FR66LH HOLE 2, CRACK L ENGTH 0.100 INCH, CRACK DIRECTION 12 0'CLOCK. (VIEW AFT FACE TO FWD FAC E). AA 5311-01216, AD RELATED, ACTIONS REQUIRED PRIOR TO FURTHER FLIGH T. HOLE DIAMETER IS SMALLER THSDR SWAA2024021343373Pressure Deck · crackedRH HORIZONTAL PRESSURE DECK WEB CRACKED; BS 663 + 2; RBL 41<[01] NDT HFEC SURFACE INSPECTED AREAS IAW 737 NDTM PART 6 51-00-00 PROC 23. .400' LONG CRACK NOTED. MARKED ENDS AND DIRECTION.<BR>EQUIP USED: NORTEC 600 IS0000680 DUE 05/24;[02] REPAIRED RH HORIZONTALSDR SWIA202403110020Door Frame · corrodedFORWARD WATER-WASTE DOOR SURROUND STRUCTURE LOWER DIAPHRAGM PN: SH670-32284-3 CORRODED. (C-CHECK RO 3/10/2024) INSTALLED NEW FORWARD WATER-WASTE DOOR SURROUND STRUCTURE LOWER DIAPHRAGM REF. DRWG SH670-32280 REV. H AND CRJ 700 SRM 51-42-06-001-001-A01. LOCASDR JJBA20240207015Crossbeam · crackedNLG W/WELL, CRACK FOUND ON NLG AFT TOP CROSSBEAM. NLG W/WELL, NLG AFT TOP CROSSBEAM REMOVED FOR REPLACEMENT. NLG W/WELL, NEW CROSSBEAM DRILLED AND INSTALLEDSDR SWIA202401290019Windshield · crackedCRACK FOUND ON LH WINDSHIELD SIDE POST AT THE UPPERMOST CENTER BOLT HOLE. (FILED CLOSED)PERFORMED REMOVAL AND REPLACEMENT OF LH WINDSHIELD SIDE POST IN REFERENCE TO TASK CARD 51-900-1002-SKY AND COMPLETED M-337. MHIRH MOBILE REPAIR TECH PERFORMED THE WORK IN RSDR CALA2024012400207Door Frame · crackedL1 DOOR STOP #1 AT FR16 LOWER INBD BOLT HOLE PRODUCED CRACK INDICATIONS AT THE 3:00 AND 8:00 POSITION PER NR9290267/42267 GEN BY V061690 NITIAL INSP ON THE LH FR16 DOORSTOP FITTING #1 HOLES 3 AND 4 PER FT REACHES 37,546 TOTAL ACFT FC. PERFORM REPEAT INSP AT INSDR AALA202401223386Pressure Deck · crackedAIRCRAFT WAS NOT GROUNDED: 0.375 INCH CRACK IN VERTICAL PRESSURE DECK WEB BETWEEN RBL 40 TO 45.64. PERFORMED REPAIR PER SRM 57-10-10-2R-3 REPAIR 3 TABLE 205/REPAIR 3.SDR CALA2024012200173Door Frame · crackedR1 FR16 DOOR STOP #1 LOWER INBD BOLT PRODUCED CRACK INDICATIONS IN THE FRAME AT THE 12:00 POSITION AND AT 6:00 POSITION, PER NR9 290271/42271 PERFORMED REPAIR IAW A319 R-DWG R53113118 REV F CAT A REPAIR NO FURTHER RE-INSPECT REQUIRED.
Back to JASC 5310