What was found
UPON CLEAN FOR PREP TO CLOSE CABIN FLOORS FOUND R/H SIDE CREASE BEAM INNER CHORD CORRODED STA 787 TO 887. GROUNDED - YES. REPAIRED CREASE BEAM INNER CHORD IAW EA 900ER-53EA-26548W=1" O=.050" R=.038" L=.3" D=.012".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON CLEAN FOR PREP TO CLOSE CABIN FLOORS FOUND R/H SIDE CREASE BEAM INNER CHORD CORRODED STA 787 TO 887. GROUNDED - YES. REPAIRED CREASE BEAM INNER CHORD IAW EA 900ER-53EA-26548W=1" O=.050" R=.038" L=.3" D=.012".