JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2022031700277Shear Tie · corrodedDURING HEAVY MAINTENANCE, INITIAL INSPECTION: [CPCP FINDING] CORROSION IN SHEAR CLIP AT FR 90 & STGR 24L-25L AT AFT CARGO COMPARTMENT; REF TOMX WO 1846 NR -00169 SHEAR CLIP WAS REPLACED PER EMB 190 SRM 51-41-01, SRM 51-41-02, AND SRM 51-75-16 PAR 4. TABLE 1 ANSDR YENA2022031700276Shear Tie · corrodedDURING HEAVY MAINTENANCE, INITIAL INSPECTION: [CPCP FINDING] CORROSION IN SHEAR CLIP OVER FR-- 76 BTW STGR-26L / STGR-27L AT AFT CARGO COMPARTMENT; REF TOMX WO 1846 NR -00114 SHEAR CLIP WAS REPLACED PER EMB-190 SRM 51-12-01 PAR 6 AND SRM 51-10-- 03 PAR 4 A ANDSDR SWIA202266226Structure · dentedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA53430-670-53-11-1549 MXCODEID49143-PR - DURING BIRD STRIKE INSPECTION FOUND DENT ON LEFT FUSELAGE BETWEEN FS 169.00 AND FS 173.00. COMPLIED TEMPORARY REPAIR PER REO 670-53-11-1549. PERMINANT REPAIR DUE IN 5100FH WITHSDR SWAA2022042084211Beam · corrodedCORROSION ON UPPER SURFACE OF B.S. 270 LATERAL BEAM AT L.B.L. 10 - R.B.L. 10; W.L 207.54. / [01] SRM 53-10-51-0I-2 FOR IDENTIFICATION AND SRM 53-10-51-1A-1 FOR ALLOWABLE DAMAGE ARE APPLICABLE;[02] REMOVED CORROSION AT DISCREPANCY AREA; L=20.' X W=.90' X D=0.02SDR SWAA2022041284251Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS328 TO BS344 AND LBL47 FWD GALLEY AND LAV 2022-131755 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS328 TO BS344 AND LBL47 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; 51-10-02 Ï¿SDR SWAA2022041284256Floorbeam · crackedCRACK FLOOR STRUCTURE BEAM LOCATED BS294.5 AND RBL55 AT FWD GALLEY AREA 2022-131749 / [01] TOOL USED EDDY CURRENT EQUIPMENT PN NORTEC 600D SN 60007161486 DUE DATE 06-DEC-22.;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE:SDR SWAA2022041284252Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV 2022-131745 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY I.A.W B737-700 SRM 51-10-02 ITEM 9 AND DWG # 1SDR SWAA2022041284254Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND LBL47 FWD GALLEY AND LAV 2022-131752 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND LBL47 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; 51-10-02 Ï¿SDR IPXA2022040280758None · corrodedINSPECTION TYPE:14-2MAIN CARGO FLOOR AT STA 1100 AFT OF PANEL 242GF AND 242 HF WL 180 HAS INTERGRANULAR CORROSIONREMOVED AND REPLACED FLOOR BEAM T CHORD PER UPS EO B757-5310-38292-ASDR ASAA2022031537778Bulkhead · crackedL/H AC BAY 663 BULKHEAD ATTACH ANGLE CRACKED IN VERTICAL LEG 2ND FASTNER OUT FROM KEEL BEAM. GROUNDED - YES. REPAIRED ATTACH ANGLE AT L/H AC B 663 IAW BOEING 737-900 SRM 57-10-10-2R-5.SDR IPXA2022032780557Channel · corrodedINSPECTION TYPE:CUPON GIVING AN OK TO INSTALL FOUND AFT CARGO PIT FWD BULKHEAD AT FS 1200 LOWER CHANNEL ASSY CORRODED AND DEEMED OUT OF LIMITS PER SRM 53-00-53-1A-1REMOVED AND INSTALLED REPLACEDMENT CHANNEL ASSY P/N 453N1626-1 PER SRM 51-40-02-0GSDR IPXA2022032780555Channel · corrodedINSPECTION TYPE:CUPON GIVING OK TO INSTALL FOUND AFT CARGO PIT FWD BULKHEAD AT FS 1200 LOWER CHANNEL ASSY CORRODED AND DEEMED OUT OF LIMITS PER SRM 53-00-53-1A-1REMOVED AND INSTALLED REPLACEMENT CHANNEL ASSY P/N 453N1626-6 PER SRM 51-40-02-0GSDR IPXA2022032680515None · crackedINSPECTION TYPE:C3CRACK WAS FOUND ON EXISTING REPAIR CHORD ON STA 1140, S-9RREPAIR I.A.W BOEING SR:4-5465517685 AND UPS EO B747-5340-83249-ASDR IPXA2022032680514Tension Tie · crackedINSPECTION TYPE:C3CRACK ON TENSION TIE FWD CHANNEL NEAR RBL 70 , STA 1180REPAIR I.A.W 747-400SF SRM 53-40-2R-1 REV.53.00SDR SWAA2022032183876Receptacle · crackedEXTERNAL POWER RECEPTACLE AFT EDGE APPROXIMATELY 5 INCHES ABOVE LOWER CORNER HAS A .5 INCH CRACK. / [01] ACCOMPLISHED REPAIR IN ZONE 1 REF SRM 53-10-15-2R-4 REPAIR 4.SDR JR2R20220315759Beam · corrodedRH CENTER FLOOR BEAM CAP CORRODED AT FR88 - FR89SDR JR2R20220315756Gusset · corrodedRH O/B FLOOR BEAM GUSSET AT FR90 CORRODEDSDR JR2R20220315757Gusset · corrodedRH I/B FLOOR BEAM GUSSET AT FR90 CORRODEDSDR JR2R20220315805Gusset · corrodedGUSSET AT FR89 LBL9 FOUND TO BE CORRODEDSDR JR2R20220315799Angle · corrodedINTERCOSTAL ANGLE AT RBL9 FWD OF FR90 CORRODEDSDR JR2R20220315755None · corrodedRH FLOOR SILL FR88-90 CORRODEDSDR JR2R20220315758Gusset · corrodedCENTER FLOORBEAM GUSSET AT FR90 CORRODEDSDR SWAA2022041883766Shear Web · corrodedCORROSION ON SHEAR WEB AT B.S. 1016+6 - 1016+14; L.B.L. 12 - L.B.L. 19; W.L. 208.1. / [01] NOT ALLOWABLE DAMAGE FOUND ON SRM FOR THIS PART;REPAIRABLE BY REPLACEMENT SHEAR WEB. IAW. SRM 51-10-02-0G-0; PARAGRAPH 9.;[02] VERIFIED CORRECTIVE ACTION #1;[03] REMOVEDSDR SWAA2022041283781Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT RBL 1 BS 277+7; BS 277+14. / [01] EVALUATED CRACK ON PASSENGER CABIN INTERCOSTAL RBL 1 BS277+7'' BS277+14'' AND NO FOUND ALLOWABLE DAMAGE ON SRM DATA; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C.;[02] RESDR SWAA2022041283778Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT RBL 30 BS 312+5. / [01] EVALUATED CRACK ON PASSENGER CABIN INTERCOSTAL RBL 30 BS312+5'' AND NO FOUND ALLOWABLE DAMAGE ON SRM DATA; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C.;[02] REMOVED PASSENGER CABISDR SWAA2022041283783Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT LBL 45 BS 312+9. / [01] EVALUATED CRACK ON PASSENGER CABIN INTERCOSTAL LBL 45 BS312+9'' AND NO FOUND ALLOWABLE DAMAGE ON SRM DATA; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C.;[02] REMOVED PASSENGER CABISDR SWAA2022041283782Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT LBL 11 BS 344+5; BS 344+9. / [01] EVALUATED CRACK ON PASSENGER CABIN INTERCOSTAL LBL 11 BS344+5'' BS344+9'' AND NO FOUND ALLOWABLE DAMAGE ON SRM DATA; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C.;[02] RESDR SWAA2022041283784Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT LBL 45 BS 328+7. / [01] EVALUATED CRACK ON PASSENGER CABIN INTERCOSTAL LBL 45 BS328+7'' AND NO FOUND ALLOWABLE DAMAGE ON SRM DATA; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C.;[02] REMOVED PASSENGER CABISDR SWAA2022041283817Tie Clip · crackedCRACK TIE CLIP LOCATED BS 277 AND STRINGER 10R AT PASSENGER CABIN (1 EA) 2022-131714 / [01] REPLACED TIE CLIP LOCATED BS 277 AND STRINGER 10R AT PASSENGER CABIN (1 EA) IAW B737-700 SRM 51-40-02 DWG 141A1110; SHEET 18; REV -<BR>SEE INDIVIDUAL SIGNOFF BELOW;[02]SDR SWAA2022041183741Web · corrodedCORROSION ON BS 348 FRAME CLOSE OUT WEB LBL 62 WL 209. / [01] REMOVED CORROSION ON 348 FRAME CLOSEOUT WEB; LBL 62; WL 209. MAX MATERIAL REMOVED WAS .019' 1' BY 2' FROM .071'. OUT OF LIMITS PER SRM 53-10-15-1A-1; SRM 51-10-02-0G-0.;[02] VERIFIED CORRECTIVE ACTISDR JR2R202203141769Beam · corrodedFWD RH SEAT TRACK BEAM CORRODEDSDR IPXA2022040280757None · dentedINSPECTION TYPE:14/2AFT LOWER CARGO PIT AT FS 1360 FRAME SEGMENT HAD TWO DENTS ON UPPER FLANGEREPAIRED FRAME PER SRM T3-00-07-2R-5 DETAIL 2SDR IPXA2022040280756None · dentedINSPECTION TYPE:14/2AFT LOWER PIT AT FS 1320 FRAME SEGMENT HAD A DENT ON UPPER FLANGEREPAIRED FRAME PER SRM 53-00-07-2R-5 DETAIL 2SDR FDEA202203130493Frame · noneAGING AIRCRAFT - EXISTING REPAIR FOUND ON FRAME AT MAIN DECK CARGO COMPARTMENT STATION 535 LONGERON 24 LEFT HAND. EXISTING REPAIR ON FRAME AT MAIN DECK CARGO COMPARTMENT STATION 535 LONGERON 24 LEFT HAND EVALUATED AND FOUND EXISTING REPAIR ANGLES WITH DEEPSDR FDEA202203130492Frame · noneAGING AIRCRAFT - EXISTING REPAIR FOUND ON FRAME AT MAIN DECK CARGO COMPARTMENT STATION 535 LONGERON 19 LEFT HAND. EXISTING REPAIR ON FRAME AT MAIN DECK CARGO COMPARTMENT STATION 535 LONGERON 19 LEFT HAND EVALUATED AND FOUND EXISTING REPAIR ANGLES WITH DEEPSDR IPXA2022033180705Crossbeam · bentINSPECTION TYPE:A300CROSSBEAM AT FR 49 BETWEEN Y=-450 AND Y=-953 BENTREMOVED AND REPLACED IAW SRM 51-40-21SDR IPXA2022032880588Support Angle · corrodedINSPECTION TYPE:1CAFT CARGO FLOOR BEAM SUPPORT ANGLE CORRODED AT X=3,Y=1841.REPAIRED CORRODED AFT CARGO FLOOR BEAM SUPPORT ANGLE IAW VT-SAA EA 011-5310-01-A9512 REV I/R AND UPS EO MD11-5310-83234-A BY P.LAU (AR-830967) DATED 03/25/2022 (MAJOR).SDR F3LA2022032200009None · corrodedDISCREPANCY: REFERENCE PEMCO N/R#12006.0066 R2 DOOR SILL AFT FASTENER HOLE CORRODED FR68
CORRECTIVE ACTION: EVALUATED & REPAIRED R2 DOOR SILL AFT CORNER AT FR 68 IAW A320 SRM 53-41-14-283-002, SRM 53-41-14-300-001, SRM 51-21-11, 51-75-12-911-002SDR IPXA2022031380047None · noneINSPECTION TYPE:A300FWD CARGO PANEL 131GE CORNERS DAMAGED.REPAIR IAW SREO A300-5320-42722-F.SDR IPXA2022031380046None · brokenINSPECTION TYPE:A300FWD CARGO PANEL 131DE BROKEN.REPAIR IAW SREO A300-5320-42722-F.SDR CALA2022031400645None · corrodedAFT CABIN RIGHT AFT SHEAR WEB HAS CORROSION ON HAECO LCQ REF 929 2269/34269 SPEC A3NB-53-3-6222. NR GENERATED BY V077956 REMOVED & REPLACED AFT SHEAR WEB AT R/H FR70 IAW A319 SRM 51-72- 11-911-001 AT HAECO LCQ ON HANGAR NR 9292269/34269 PERFORMED BY MECH V9132SDR JR2R20220312744Angle · crackedLH WHEEL WELL STUB ANGLE CRACKED AT FR52SDR JR2R20220312743Frame · crackedLH WHEEL WELL FAIRING SUPPORT IS CRACKED AT FR52SDR JR2R20220312762Shear Panel · corrodedCENTER SHEAR PANEL AT FR87-FR88 CORRODEDSDR JR2R20220312785Doubler · corrodedRH FLOOR SILL PLATE CORRODED FR12-FR14SDR JR2R20220312764Shear Panel · corrodedLH SHEAR PANEL AT FR87-FR88 CORRODEDSDR JR2R20220312754Shear Panel · corrodedRH SHEAR PANEL FR87-FR88 CORRODEDSDR JR2R20220312777Angle · corrodedINTERCOSTAL ANGLE AT RBL9 BETWEEN FR90 AND FR100 CORRODEDSDR JR2R20220312791Intercostal · corrodedINTERCOSTAL AT RBL9 BETWEEN FR90 AND FR100 CORRODEDSDR IXXA2022061312Strap · corrodedFLC FWD DOOR FRAME UPPERSTRAP CORRODED
Back to JASC 5310