JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A2022031300205Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND CORROSION FOUND ON RH BAGGAGE SUPPORT ON FR 20 STR 29R. MX REPLACED SHEAR CLIP PN 170-06272-004 IAW SRM 51-41-01. AC REMAINS IN YQG FOR COMPLETION.SDR REXA2022030300350Support · corrodedFWD JACK FITTING AT FS 278 L/H INTERCOSTAL IS CORRODED. - REMOVED & REPALCED INTERCOSTAL W/ NEW SERVICEABLE PART IAW CRJ 900 SRM 51-42-21-001-001-A01 & COMPLIED WITH ENDEAVOR EA NO CRJ 953-12928 REV IR DATED 2/16/2022.SDR REXA2022030200304Intercostal · corrodedFWD JACK FITTING AT FS 278, RH INTERCOSTAL IS CORRODED. - DISPLACED & REINSTALLED DRAIN TUBE & DISPLACED & REINSTALLED RH FLOOR FLIGHT DECK COOLING DUCT IAW CRJ 900 AMM 20-21-00-910-801-A01. NO DISCONNECTIONS. NO LEAK CHECK REQUIRED. REMOVED AND REPLACED RH FWSDR V0XD20220225002Intercostal · corrodedINTERCOSTAL AT F.S 364 AT STGR 27 IS CORRODED. CORRECTIVE ACTION: REMOVED AND REPLACED THE INTERCOSTAL AT F.S 364 AND STGR 27 IAW CRJ 700 SRM 51-42-06.SDR R61A2022031200202Shear Plate · corrodedCFIII, SHEAR CLIP AT FR 83 BTWN STR 28R-29R CORRODED. R&R IAW SRM 51-41-02.SDR R61A2022031200201Shear Plate · corrodedCFIII, SHEAR CLIP AT FR 84 BTWN STR 28R-29R CORRODED. R&R IAW SRM 51-41-02.SDR IPXA2022022479377Frame · crackedINSPECTION TYPE:SEGFUSELAGE FRAME FOOT FITTING AT LH SIDE FRAME 44 IS CRACKED AT AREA 1.ACCOMPLISHED REPAIR PER APPENDIC J OF EO A300-5310-46789-GSDR SWAA2022033177105None · crackedUPON INSPECTION OF CCN:753-201-00-02; FOUND 5 EA CRACKS AT BS 665 LBL 30 WL 201 AND BS 672.5 LBL 32 - 35 WL 201; COMMON TO THE HORIZONTAL PRESSURE DECK; AREAS MARKED. / [01] REMOVED FLOOR SUPPORT AT BS 663 LBL45-LBL 60 WL 208 PER SRM 51-40-02-0G-0;[02] INSTALLSDR SWAA2022032876815Web · crackedCRACK WEB LOCATED BETWEEN BS927 TO BS947 AT LEVEL STR25R AT AFT CARGO COMPARTMENT 2022-98596 / [01] REPLACED WEB LOCATED BETWEEN BS927 TO BS947.5 AT LEVEL STR 25R AFT CARGO COMPARTMENT IAW SRM B737-700 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DRAWING 147A7500 SHSDR SWAA2022032276513Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOC. BS 380 TO BS 400 RBL 6 AT FWD GALLEY AREA 2022-80406 / [01] REPLACED NEW ANGLE AND FASTENER EXACTLY LOCATION ON BS 380 TO BS 400 RBL 8 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 143A5400 REV A.SDR REXA2022032200475Crossbeam · corrodedFOUND LH FS 280 CROSSBEAM CORRODED AT MULTIPLE LOCATIONS. - REMOVED UNSERVICEABLE, LOCATED, DRILLED AND INSTALLED A NEW SERVICEABLE PN CC670-34094J P-18. INSTALLED NEW SERVICEABLE FS 280 LH CROSSBEAM IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, SDR REXA2022032200458Angle · corrodedFS 280.00 CROSS BEAM J ANGLE IS CORRODED BETWEEN LBL 9 AND RBL 9. - REMOVED UNSERVICEABLE, LOCATED, DRILLED AND INSTALLED A NEW SERVICEABLE FS 280 J ANGLE PN CC670-34095-1 IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-42-06-001-001-A01 AND 51-SDR SWAA2022030376905Doubler · crackedEXTERNAL POWER CONNECTION DOOR CUTOUT DUBLER SKIN LOWER SIDE TWO CRACKS AT RIVETS LOCATION. / [01] TRIMMED OUT THE LOWER DAMAGED AREA OF THE EGPR SURROUND DOUBLER PER B-737-700 SRM 53-10-15-2R-4 STEP 4.C.;[02] AFTER TRIM; CUT WAS SMOOTHENED OUT TO A 63 MICROINSDR EE4Y2022022315198None · none1. DURING STRUCTURE INSPECTION IT WAS FOUND AT Y=273.0MM FLOOR TRACK SUPPORT WITH UPPER FLANGE CORRODED BETWEEN FR12/14.WAS REPAIRED FOLLOWING EMBRAER REPAIR INSTRUCTIONS UNDER ETD2022-190-004221 AND COOPESA EO # COO-EO-2022-15109-R00 AND APPROVED ON ANAC F-20SDR EE4Y2022022315197Skin · dented1) DURING STRUCTURE INSPECTION WAS FOUND AN EXISTING REPAIR DOUBLER LOCATED BETWEEN FR18 AND FR19 BETWEEN STRG-12R AND STRG-14R, THE DOUBLER WAS REMOVED BECAUSE THE REPAIR DOES NOT MEET THE SRM REQUIREMENTS. WAS REPAIRED FOLLOWING EMBRAER REPAIR INSTRUCTIONS USDR EE4Y2022022315195Skin · dented1) DURING STRUCTURE INSPECTION WAS FOUND AN EXISTING REPAIR DOUBLER LOCATED BETWEEN FR10 AND FR12 BETWEEN STRG-13R AND STRG-17R, THE DOUBLER WAS REMOVED BECAUSE THE REPAIR DOES NOT MEET THE REF./B/ SRM REQUIREMENTS. WAS REPAIRED FOLLOWING EMBRAER REPAIR INSTRUSDR FDEA202202230350Frame · dentedMAIN DECK CARGO MAIN FRAME FOUND DEFORM AT STA 1727 S-19R. DEFORMED FRAME REPAIRED AS PER B777 SRM 53-00-07- 2R REPAIR 1 REV 40.0 AND EA G-5310-T0367399 P1, TITLE: FUSELAGE - MAINFRAME - REPAIR OF DENT ON STA1727 FRAME INNER FLANGE AT S-18R. REFER TO WRI:5SDR SWAA2022032876813Panel · erodedEROSION ACCESS PANEL 193AR AT FUSELAGE EXTERIOR 2022-98591 / [01] TOOL USED CALIPER P/N: 500-464 S/N: 15331932 DUE DATE: 26-OCT-22.;[02] REPAIRED ACCESS PANEL 193AR AT FUSELAGE EXTERIOR AS PER B737-700 SRM 51-70-05-2R-2 REP.2; B737-700 SRM 51-70-05-2R-2 REP. 2SDR SWAA2022031176373Web · crackedCRACK ON LOWER SILL LOCATED BS 792 TO BS 847 AT LEVEL S-25R AFT CARGO COMPARTMENT 2022-95123 / [01] REPLACED LOWER SILL WEB AND FASTENERS LOCATED BS 792 TO BS 847 AT LEVEL S-25R AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 AND B737-700 SRM 51-40-02 AND DRAWSDR REXA2022031000399Seat Track · corrodedFWD FUSELAGE L/H FLOOR SEAT TRACK #2 FS477-581 RBL9 CORRODED. - REMOVED SEAT RAIL AT RBL 9 BETWEEN FS 477 AND 581 IAW CRJ900 AMM53-00-49-000-801-A01. FABBED, LOCATED, DRILLED AND INSTALLED SEAT RAIL AT RBL 9 FS 477-581 IAW CRJ900 SRM 53-00-49-201-002-A01, 51-SDR IPXA2022030279611None · noneINSPECTION TYPE:C4MAIN CARGO DECK AT LONGERON 15L TEE-ANGLE IS CRACK AT STA 1341.REMOVED, FAB, REPLACED CRACK TEE-ANGLE IAW MD11 DWG AEA7568 AND MD11 SRM 51-31-01 AND 51-33-01. (MINOR)SDR REXA2022030200306Angle · corrodedFS 264 LOWER FRAME SEGMENT CORRODED BETWEEN STGR 25L AND STGR 25R. TCI: 53-10-303 - REMOVED INTERCOSTAL BETWEEN FS 265 TO 280, STR 26L TO 27 IAW CRJ 900 SRM 51-42-06/21-001-001-A01. REFER TO JOB: 81522361, OP: 562 FOR INSTALL. REMOVED CORROSION FROM FS 264 BETSDR IPXA2022022279309Frame · crackedINSPECTION TYPE:SEGFUSELAGE FRAME FOOT FITTING AT LH SIDE FRAME 45, IS CRACKEDACCOMPLISHED REPAIR PER APPENDIX J OF EO A300-5310-46789-GSDR IPXA2022022279308Frame · crackedINSPECTION TYPE:SEGFUSELAGE FRAME FOOT FITTING AT LH SIDE FRAME 46, IS CRACKED AT AREA 1ACCOMPLISHED REPAIR PER APPENDIX J OF EO A300-5310-46789-GSDR FDEA202202210343None · noneMAIN CABIN AFT DECK PLATE UPPER SURFACE STA 1681 LBL 20 TO 55 FLOORBOARD ATTACHMENT HOLES DAMAGED. ACCOMPLISHED FEDEX EA# F-5310-T0367139 FUSELAGE - MAINFRAME- FLOOR BEAM AND DECK PLATE - STA 1681 - LBL 32 - 47, ELONGATED HOLESSDR SWAA2022032876153None · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS344 TO BS360 AND RBL12 FWD GALLEY AND LAV 2022-98530 / [01] REPLACED WEB-INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN BS344 TO BS360 AND RBL12 FWD GALLEY AND LAV. IAW SRM B737-700 51-40-02; SRM 51-10-02 SDR SWAA2022032876154Web · crackedCRACK WEB LOCATED BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA 2022-98532 / [01] REPLACED WEB AND FASTENERS ON BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 85 REV-.;[02] REPLACED WEB AND FASTENERS ON BS277 TO BS29SDR FDEA202202190323None · noneM AIN CARGO SEAT TRACK SURFACE WORN BS 700 RBL 24 REMOVED AND REPLACED SEAT TRACK IAW B757-2 SRM 51-40-02-0G AND DWG 143N5080 REV B, ACCOMPLISHED FEDEX EA # F-5310-T0367159-P1, FUSELAGE - MAINFRAME - SEAT TRACK, STA 700-780 RBL 24, ALTERNATE FINISHSDR SWAA2022040475294None · crackedTYPICAL CRACK FOUND EMANATING FROM FWD GALLEY DOOR (R1) BEARTRAP FASTENER LOCATION ADJACENT TO FITTING LATCH AT BS 290-296; BETWEEN S-8R AND S-9R. (CRACK LENGTH :0.433') TYPICAL CRACK FOUND EMANATING FROM FWD GALLEY DOOR (R1) BEARTRAP FASTENER LOCATION ADJACENSDR SWAA2022033075405Beam · crackedCRACK EXISTING REPAIR ON STUD BEAM LOCATED BS 294.5 AND STRINGER 17R AT PASSENGER CABIN 2022-109286 / [01] REPLACED STUD BEAM(FRAME) AND FASTENERS LOCATED BS 294.5 AND STRINGER 17R AT PASSENGER CABIN IAW B737-700 SRM 51-40-02 AND 51-10-02 DWG: 141A8370 REV.D;[SDR SIMA20220218012None · noneSSI 53-10-027: RH FLOOR SILL CORRODED BETWEEN FR12-14.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH FLOOR SILL BETWEEN FR 12-14 IAW EMB 175 SRM 51-40-08, 51-40-02, AND 51-43-04.SDR IPXA2022030779799Longeron · corrodedINSPECTION TYPE:4CCENTER CARGO LONGERON 49 L/H IS CORRODED BETWEEN STA. 5-113 TO 5-123/1531.REPAIRED CORRODED LONGERON 49L BETWEEN STA. 5-103 TO 5-123/1531 IAW VT-SAA EA 011-5310-01-A9496 REV. I/R AND UPS EO MD11-5310-83065-A. (MAJOR)SDR SIMA20220218011Not Reported · not reportedSSI 53-23-005: RH FLOOR BEAM AT FR85 CORRODED. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH FLOOR BEAM UPPER DOUBLER AT FR 85 IAW EMB-175 SRM 51-40-08, SRM 51-41-01, AND SRM 51-43-03SDR SIMA20220218009Not Reported · not reportedSSI 53-23-005: RH FLOOR SPLICE CORRODED AT FR 90.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH FLOOR SPLICE AT FR 90 IAW EMB 175 SRM 51-40-08.SDR SIMA20220218008Not Reported · not reportedSSI 53-23-005: RH SHEAR PANEL CORRODED AT FR 87. (LEVEL 2 CORROSION)-C/A- INSTALLED RH SHEAR PANEL AT FR 87 IAW EMB 175 SRM 51-40-08 51-42-01 51-43-03SDR SIMA20220218010Not Reported · not reportedSSI 53-23-005: RH PANEL SUPPORT CORRODED AT FR 89. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH PANEL SUPPORT AT FR 89 IAW EMB 175 SRM 51-40-08.SDR ASAA2022021837551Intercostal · corrodedAFT WET AREA R/H G4 GALLEY MOUNT SUPPORT INTERCOSTAL RBL 33 STA 986 TO 1006 IS CORRODED. GROUNDED - YES. LOCATED AND DRILLED NEW INTERCOSTAL IAW 737-800 SRM 51-40-05-0G-0 REMOVAL AND INSTALLATION TO BE C/W ON CARD S/N OK298249W=1 O=.100 R=0 L=1 D=.100.SDR IPXA2022022779458Longeron · noneINSPECTION TYPE:C4CTR CARGO BILGE AREA AT STA 1541 HAS CORROSION ON LONGERON 52.REMOVED,FAB AND REPLACED CORRODED LONGERON 52 IAW DWG AFA7762 AND SRM 51-33-01. (MINOR)SDR CALA2022022100452Skin · damagedEVIDENCE OF EXTERNAL AND INTERNAL LIGHTNING STRIKE DAMAGE AT STA 95.5 APPROX AT S-25L REMOVED PAINT REF SRM B787-A-51-23-03-00A-010A-A . ACP''D UT INSPECTION PER AVO9399 ITEM B1, 2 AND 3 AFTER REWORK. ADDITIONAL DAMAGED AREA AWAITING ENGINEERING DISPOSITION. ISDR CALA2022022100451Frame · dentedAFT CARGO COMPARTMENT FRAME 727G @ STR23R FOUND DENTED AND REPAI RED ON FLEETCYCLE NR 9801935 PER ECRA 5311-02757. REQUIRES DIP TO ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF EC/RA 5311- 0275 ON OR BEFORE 75,000 TOTAL FLIGHT CYCLES. PLACE ON DIP TO ACCOMPSDR SWAA2022040473912Depressor · crackedFWD ENTRY DOOR CUTOUT PRESSURE SEAL DEPRESSOR CRACKED NEAR UPPER HINGE (UPPER SIDE OF HINGE) / [01] REMOVED PRESSURE SEAL DEPRESSOR AT L1-DOOR. REF. B737-7.SRM-51-40-02-0G-0;[02] VERIFIED STEP 1;[03] LOCATED AND DRILL NEW PRESSURE SEAL DEPRESSOR IAW B737-700 SSDR SCNA20220322010None · noneDEFECT: CRACK DAMAGE AT THE RH #3 WINDOW FRAME WAS BEYOND ALLOWABLES. RESOLUTION: REPAIRED PER SCA SCA TC 737-53-1345-02-PART1-4-RH-1.SDR SWAA2022031673890None · crackedEXTERNAL POWER CUTOUT LOWER DOOR LATCH BLOCK ATTACH POINT CRACKED / [01] PREFORMED CUTOUT AT POWER CUTOUT LOWER DOOR LATCH BLOCK ATTACH POINT IAW SRM 53-10-15-2R-4;[02] VERIFIED STEP 1.;[03] VERIFIED NEW MATERIAL AS P/N 2024-T3-050/ 2024-T3-040 ATAG# A12631/A5SDR IPXA2022030279653Web · damagedINSPECTION TYPE:A300STA 1885.20 WEB P/N 148N8402-59 IS DEFLECTED/DAMAGED 12"I/B AND 12"O/B OF BL 0REPAIRED PER EA 757-5388-27-A2840 AND UPS EO B757-5310-82905-ASDR SIMA20220217004Not Reported · not reportedSSI 53-23-005 RH CENTER SEAT TRACK IS CORRODED/GOUGED BTW FR 83-84. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH CENTER SEAT TRACK BTW FR 83-84 IAW EMB 175 SRM 51-40-08.SDR ASAA2022021737554Intercostal · corrodedAFT WET L/H G4 GALLEY MOUNT SUPPORT LBL 32 STA 986 TO 1006 IS CORRODED ON TOP CAP UNDER WHERE MOUNT FITTING SITS. GROUNDED - YES. LOCATED AND DRILLED NEW INTERCOSTAL IAW 737-800 SRM 51-40-05-0G-0 REMOVAL AND INSTALLATION TO BE ACCOMPLISHED ON CARD OK298249W=1 SDR SWAA2022022173872Web · elongated3 EA. AFT FASTENER HOLES ELONGATED ON L/H SUPPORT STRUCTURE WEB / [01] FABRICATED AND TRIMMED NEW STRUCTURE WEB OUT OF 2024-T3 0.040'<BR>DILLED AND INSTALLED PER SRM 51-40-05 AND 51-40-02SDR AALA202202215080None · noneAIRCRAFT WAS GROUNDED: CORROSION OF WASTE TANK EXHAUST VENT. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR IPXA2022021779119Frame · crackedINSPECTION TYPE:SEGFUSELAGE FRAME FOOT FITTING AT RH SIDE FRAME 45, IS CRACKED AT AREA 1ACCOMPLISHED REPAIR PER APPENDIX K OF EO A300-5310-46789-GSDR IPXA2022021779118Frame · crackedINSPECTION TYPE:SEGFUSELAGE FRAME FOOT FITTING AT RH SIDE FRAME 46, IS CRACKED AT AREA 1.ACCOMPLISHED REPAIR PER APPENDIX K OF EO A300-5310-46789-G
Back to JASC 5310