SDR SIMA2019060421006Crossbeam · crackedCROSSMEMBER ON THE AFT SIDE OF NLG UPLOCK BOX HAS A 1 1/2" CRACK.-C/A-REPLACED CROSSMEMBER ON AFT SIDE OF NLG UPLOCK BOX IAW SRM 51-40-02.SDR SWIA2019061445982Panel · damaged2 ADDITIONAL FASTENER HOLES ELONGATED (APPROX. .225") FOR RH KIDNEY PANEL (132AL). LOCATED ON FWD EDGE OF CUTOUT JUST BELOW STR20R. (C-CHECK) RO: 06/14/2019 REPAIRED 2 ADDITIONAL FASTENER HOLES IAW REO.SDR IPXA2019060742942Doubler · crackedINSPECTION TYPE:2CCENTER W/W L/G FWD. WALL AT PUSH ROD FEED THRU, THE DOUBLER IS CRACKED.REMOVED AND REPLACED DOUBLER IAW SRM 51-33-01. (MINOR)SDR AALA201905219023Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT SERVICE DOOR CUT OUT LOWER BEAM. REPLACED BEAM PER SRM 53-23-11AD.SDR SWAA2022030806797Support · corroded***CORROSION*** FWD CARGO BAY R/H FLOOR TO SIDE WALL SUPPORT HAS AREAS OF CORROSION STA 500A TO 500B / UPON INVESTIGATION FOUND FLOOR TO SIDEWALL SUPPORT TO BE OUT OF LIMITS BS 500A-500B 1'X0.75'X0.005 FROM ORIGINAL THICKNESS OF 0.040 PER SRM 53-00-53-1A-2. RESDR R61A201905190515Beam · corrodedDURING HEAVY CHECK - WHILE PERFORMING 2195:170EO-53-14-0002-170EO-53-14-0002 L1 DOOR LOWER BEAM REWORK FOUND CORROSION AROUND FWD AND AFT GIRT BAR FITTINGS AS MARKED. REPLACED BEAM.SDR RJEY2019052200001Window Frame · crackedCRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER ATTACHMENT INTERNAL SIDE INNER VERTICAL FACE RT/LT SIDE.SDR SWAA2022030846498Support · corroded***CORROSION*** ON LOWER BULKHEAD SUPPORT ANGLE BS500D LBL27-RBL27 WL156 FCB / NO LIMITS FOR CORROSION ON BULKHEAD SUPPORT REPAIR BY REPLACEMENT. REMOVED AND REPLACED DAMAGED BULKHEAD SUPPORT AT BS 500D IAW SRM CH 51-40-02 AND DRAWING #143A9481.SDR SWAA2022030846495Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT RBL27 BS400-BS420 WL156 FCB / DAMAGE TO SIDEWALL SUPPORT FOUND TO BE OUT OF LIMITS PER SRM CH 53-00-53-1A-2. REMOVED AND REPLACED SUPPORT IAW SRM CH 51-40-02 AND DRAWING #143A7501.SDR SWAA2022030877468Intercostal · elongatedREF: N/R X784577 1 EACH ELONGATED HOLE ON REAR PRESSURE BULKHEAD COMMON TO INTERCOSTAL P/N 65-54862-23 / REMOVED 1 EA ELONGATED HOLE FROM REAR PRESSURE BULKHEAD COMMON TO INTERCOSTAL P/N 65-5486-23 TO 247 AND INSTALLED REPAIR FASTENER IAW AAR EA 190359 IR AND SDR SWAA2022030872892Intercostal · corrodedFWD LAV FWD INBD FLOOR MOUNT FITTING HAS EVIDENCE OF CORROSION INSIDE MOUNT BOLT HOLE. / REMOVED AND REPLACED THE INTERCOSTAL BETWEEN FLOOR BEAMS STA 270 AND STA 294.5 AT LBL 11.16 PER SRM 51-10-02. ALSO REPLACED THE LAV TIE DOWN FITTING ON SAME INTERCOSTAL PESDR IPXA2019061072951Doubler · crackedINSPECTION TYPE:3C, CENTER W/W LEFT PUSH ROD FEED THRU CUT-OUT DOUBLER IS CRACKED.REMOVED AND REPLACED DOUBLER IN CTR. W/W IAW SRM 51-33-01. (MINOR)SDR IPXA2019060322736Retainer · deformedINSPECTION TYPE:1C APU COMPARTMENT,DOOR CUTOUT,AFT EDGE, MIDDLE SEAL RETAINER DAMAGEDREMOVED AND REPLACED DAMATGED RETAINER PER A300-600 SRM 51-40-21SDR SWAA2022030828233Gusset · crackedFWD CARGO GUSSET CRACKED STA 500D; S-19L / REMOVED AND REPLACED WITH NEW GUSSET FWD CARGO STA 500D; S-19L IAW SRM 51-40-02 SRM 51-40-05 AND DWG 143A7902 PO #73835-1SDR VNAA2019051699901Beam · corrodedFS280 BEAM TOP FLANGE (MPN CC670-34175-3) AND FWD J-ANGLE (MPN CC670-34095-1) AT COCKPIT THRESHOLD ARE CORRODED BEYOND LIMITS (EXFOLIATION). C/A: COMPLIED WITH SERVICE BULLETIN 670BA-53-041 REV.F, PART A - CENTER FUSELAGE FS 280 TO FS 477 - REINFORCEMENT OF THSDR AALA201905289023Door Frame · corrodedAIRCRAFT IN BASE VISIT: AFT MAIN CABIN AT AFT SERVICE DOOR, LOWER FRAME FOUND 3EA. AREA OF CORROSION (JG02), CORROSION L=1.1 X W=.550 X D=.024. REMOVED AND REPLACED SUPPORT-SEAL REST FROM AFT MAIN CABIN AT AFT SERVICE DOOR, LOWER P/N: 170-87556-502 BATCH#00034SDR SWAA2022030972833Intercostal · corrodedFWD LAV AFT OUTBD FLOOR MOUNT FITTING HAS EVIDENCE OF CORROSION INSIDE MOUNT BOLT HOLE / REMOVED AND REPLACED INTERCOSTAL AT F.S 294.5 TO F.S 312 LBL 45 PER SRM 51-40-02SDR SWAA2022030972839Intercostal · corrodedFWD LAV AFT INBD FLOOR MOUNT FITTING HAS EVIDENCE OF CORROSION INSIDE MOUNT BOLT HOLE / REMOVED AND REPLACED THE INTERCOSTAL BETWEEN FLOOR BEAMS STA 295.5 AND STA 312 AT LBL 11.16 PER SRM 51-10-02. ALSO REPLACED THE LAV TIE DOWN FITTING ON SAME INTERCOSTAL PERSDR SWAA2019060433278Pressure Deck · crackedHORIZONTAL PRESSURE DECK CRACKED BETWEEN BS. 663 TO BS. 675, BETWEEN LBL 30 TO LBL 60. / REPAIRED DECK PER SRM.SDR AALA201906039023Beam · corrodedAIRCRAFT IN BASE VISIT: BEAM AT FR 14, WL Z-500 HAS CORRODED AREA 1X .75 X .075IN. REMOVED AND REPLACED BEAM P/N D5311283020201 IAW SRM 51-42-11.SDR R61A2019060140561Beam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND L1 DOOR LOWER BEAM CORROSION AROUND GIRT BAR FITTINGS AS MARKED. REMOVED AND REPLACED L1 DOOR BEAM REF SRM
51-40-08. A/C REMAINS IN CHECK.SDR R61A2019060140559Crossbeam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION- RH CROSSBEAM AT FR 84 AS MARKED. PERFORMED PERMANENT REPAIR ON CROSSBEAM FR84 R/H SIDE BY L-ANGLE REPAIR AND RESTORED
SURFACE PROTECTION IN ACCORDANCE WITH, REF ETD2019-170-066925. A/C REMAINS IN CHECK.SDR R61A2019060140555Beam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION ON FWD AND AFT GIRT BAR CUTOUT EDGES. REMOVED AND REPLACED L2 DOOR LOWER BEAM. REF: SRM 51-40-08. A/C REMAINS IN CHECK.SDR SWAA2022030905140Stiffener · crackedVERTICAL STIFFENER IS CRACKED BS 663 LBL 27 WL 144 / REMOVED AND REPLACED VERTICAL STIFFENER B.S. 663 LBL27 WL144 PER SRM 51-40-02-0G-0 AND DWG 111A1000SDR SCNA20190513062Window Frame · crackedTHE R1 WINDOW FRAME HAS A CRACK ON THE UPPER OUTER CORNER, MARKED WITH STREAMER A5/046. REF W/O AND CUSTOMER CARD REPAIRED.SDR AALA201905149022Stop Fitting · wornAIRCRAFT IN BASE MAINTENANCE: FORWARD PASSENGER DOOR FRAME STOP FITTING NR 1 PAD IS WORN. REPLACED DOOR STOP PAD PER AMM 53-10-21.SDR AALA201906049039Door Frame · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON FRAME 16 L/H SIDE DOOR STOP FITTING 7 HOLE INBOARD UPPER AT FWD GALLEY AREA (1 EA). PERFORMED ROTOTEST INSPECTION ON FR16 LH DOOR STOP FITTING 7 INBOARD UPPER AT FWD GALLEY AREA AND FOUND CRACK ON HOLE OF INTERCOSTALSDR DALA2019051302997Beam · corroded(LOG 1069894) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM STA 947+4 INCH AND RBL 47 AT AFT GALLEY AREA. REPLACED FLOOR STRUCTURE BEAM STA. 947+4 AND RBL 47 AFT GALLEY AREA AS PER SRM 51-10-02 ITEM 9 SRM 51-40-02 AND DWG #147A5650.SDR DALA2019051202994Beam · corroded(LOG 1069912) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM STA 947+4 INCH LBL 47 AT AFT GALLEY AREA. REPLACED FLOOR STRUCTURE BEAM STA 947+4" LBL 47 AFT GALLEY AREA AS PER SRM 51-10-02.SDR SWIA2019061445984Post · crackedFS409+128 VERTICAL POST @ BL0 RH SIDE HAS AN INDICATION .1" LONG BY 55% FSH IN THE UPPER AFT RADIUS AT WL69. (C-CHECK) RO: 06/14/2019 . REMOVED AND REPLACED 409 +128 BL0 POST IAW REO AND SRM.SDR SIMA20190510002Crease Beam · corrodedCORROSION ON RIGHT HAND CREASE BEAM BETWEEN FRAMES 19-20. C/A-REMOVED AND REPLACED RT CREASE BEAM BETWEEN FRAMES 19-20 IAW SRM 51-40-02.SDR DALA2019051102982Door Frame · corrodedCORROSION LOWER AREA OF AFT CARGO COMPARTMENT DOOR JAMB IN REF 5300-2007. (CCT). NRC 00230: CORROSION LEVEL 2, AFT CARGO COMPARTMENT DOOR JAMB PAN WAS REPLACED PER SRM 51-41-02-0G, 51-41-05-0G, 51-41-01-0G, AND 53-20-15-2R-7. (LP #1068577)SDR AALA201906269037Window Post · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON WINDSHIELD LATERAL POST RIGHT SIDE UPPER ATTACHMENT . REPLACED WINDOW POST PER EA 294111.SDR AALA201906269036Window Post · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON WINDSHIELD LATERAL POST RIGHT SIDE UPPER ATTACHMENT . REPLACED WINDOW POST PER EA 294113.SDR IPXA2019061243159Fork · crackedINSPECTION TYPE:12Y, FWD CARGO COMPARTMENT DOOR FRAME FORK AT FR 23A HOLE 2, HAS A CRACK INDICATION AT THE 6 O'CLOCK POSITION WITH A DEPTH OF 0.118 - 0.120 FROM OUTER SURFACE.REPAIRED IAW REO G22024 REV IR DATED 22 MAY 19 AND UPS EO A300-5230-57953-C APPX A.SDR SWIA2019061145971Post · cracked6EA FS409+128 VERT POSTS HAVE CRACK INDICATIONS NOTED IN THE AFT RADIUS AT WL69,. ALL 6 INDICATION FAILED NDT. (C-CHECK) REMOVED AND REPLACED 6EA FS409+128 VERT POSTS IAW REO.SDR C77A2019050800002Beam · corrodedDURING HEAVY MAINTENANCE CORROSION WAS FOUND ON BEAM (P/N 170-66280-001) AT S-28R BETWEEN FRAME 80 (X = 21192) AND FRAME 81 (X = 21617). THE CORROSION WAS BLENDED OUT RESULTING IN TWO BLEND OUTS. THE FIRST BLEND OUT IS 2.9" L X 1.0" W, X .05" D AND THE SECONSDR AALA201906269035Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION WERE NOTED ON THE CENTER WINDSHIELD FRAMING AT THE CENTER POST LOWER ATTACHMENT RIGHT HAND WINDOW FRAME. REPLACED WINDOW FRAME PER EA 294029.SDR AALA201906269034Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION WERE NOTED ON THE CENTER WINDSHIELD FRAMING AT THE CENTER POST LOWER ATTACHMENT LEFT HAND WINDOW FRAME. REPLACED WINDOW FRAME PER EA 294029.SDR SWAA2022030948152None · crackedBREAK PANEL IS CRACKED STA 540; RBL 25-45; WL 208. / REMOVED AND REPLACED DAMAGED BREECH PANEL WITH NEW ONE AT BS 540 RBL 25-45; WL 208 IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG # 143A0060 REV A; AMM 53-21-00-000-801 AND AMM 53-21-00-400-801. 57193U 16MAY1SDR SWAA2022030978316Intercostal · crackedAFT CARGO INTERCOSTAL BETWEEN BS. 927-947 AND S-26R CRACK FOUND. / REPLACED AFT CARGO INTERCOASTAL BETWEEN BS 927-947 AND 3-26R AFTER THE FABRICATION ON N/R . W101959-2014926-1000-0116. INSTALLATION ACCOMPLISHED IAW B737 SRM 51-40-02-0G-0 AND DWG 147A7580SDR SWAA2019052933055Crease Beam · corrodedUNDERSIDE OF CREASE BEAM WEB CORRODED BETWEEN BS. 695 TO BS. 706, LBL 65. R&R CREASE BEAM WEB IAW DWG & SRM.SDR DALA2019050602877Beam · corroded(LOG 1060915) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM LOC AT LEVEL BS967 AND BTW LBL 5 TO RBL 5 AT AFT GALLEY AREA DUE TO FABRICATED REPAIR. PERFORMED PERMANENT REPAIR ON FLOOR STRUCTURE BEAM BS 967 AND BTW LBL 10 RBL 10 AT AFT GALLEY AREA AS PESDR CALA2019050700705Window Post · crackedCRACK INDICATION ON LT WINDSHIELD AT SIDE POST FR4 REPAIRED LT WINDSHIELD SIDE POST AT FR4 LOWER WEB IAW ECRA 5311-02139 REV A, ACCOMPLISH THE INITIAL INSP REQUIREMENTS AT LT WINDSHIELD SIDE POST PER PART 2 OF ECRA 5311-02139 REVA ON OR BEFORE THE A/C REACHES SDR DALA2019050602812Door Frame · crackedCRACK INDICATION IN OPEN HOLE LOWER INBOARD FRAME 20 RT SIDE AT LEVEL DOOR STOP FITTING 7. PERFORMED PERMANENT REPAIR IN FR20 RT SIDE AT LEVEL DOOR STOP FITTING 7 (OPEN HOLE) AS PER PRI 577234-14 REV.0, 577234-14 REV.1 AND ER/A 577234-14AD REV.ORIGINAL. SEE LOSDR CALA2019050700695Door Frame · crackedRT FR68 DOOR STOP FITTING NR 1 BOTTOM FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION ACCOMPLISHED REPAIR OF CRACKED LOWER I/B HOLE AT LOWEREST STOP FITTING ON FR68 RT IAW SRM 53-41-12 -300-010, INSP THRESHOLDS FROM TIME OF REPAIR EMBODIMENT FC41900/FH NOSDR DALA2019050402834Door Frame · cracked(LOG 1058962) DURING INSPECTION FOUND CRACKED SERVICE DOOR CUT OUT STUB FRAME BS 296.4 AND STR 17R AT FWD GALLEY AREA. FRAME BS 296.4 AND STR 17R AT FWD GALLEY AREA ASPER PRI 577466-14 REVISION 0,1,2 AND ER/A 577466-14AD REVISION ORIGINAL.SDR SWAA2022030978313Intercostal · corrodedSTA 1016 AFT PRESSURE WEB AT FLOOR LEVEL INTERCOSTAL P/N: 65-54862-17 HAS CORROSION AND IT REQUIRES TO BE FABRICATED / AFTER EVALUATION OF CORRISION AT THE AFT PRESSURE BULKHEAD LOWER LOBE INTERCOASTAL P/N 65-54862-17 BETWEEN LB-0 TO LB2-28 FOUND TO BE OUT OF SDR CA190503025Doubler · cracked(CAN) DURING AN HMV INSPECTION (425-ZL-115GVI-10000-1), A CRACK WAS FOUND ON THE R/H TEAR STRAP DOUBLER AT FR 7 AT THE AFT NLG TO WEB AREA AT STA 20R. REFERENCE WO 33421433 NR 95. PART TO BE REPLACED. PN S53172101205 (TC# 20190503025)SDR CA190503027Doubler · cracked(CAN) DURING HMV INSPECTION, (425-ZL-115GVI-10000-1) A CRACK WAS FOUND ON THE LEFT HAND TEAR STRAP DOUBLER AT FR 7 AT THE AFT NLG TO WEB AREA AT STA 20L. REFER WO 34421433 NR 94. PART TO BE REPLACED. PN S53172101204 (TC# 20190503027)