JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR COEA2013021503913Crease Beam · corrodedWO 119832 NR 100039 HEAVY CHECK COE/MINOR REPAIR: MISSING SURFACE PROTECTION AND POSSIBLE CORROSION ON RIGHT CREASE BEAM WEB INNER CHORD, FR23-25. REPLACE PART PER ATR42 SRM 53-51-50.SDR COEA2013021501913Crease Beam · corrodedWO 119832 NR 100023 HEAVY CHECK COE/MAJOR REPAIR: LEVEL 2 CORROSION ON UPPER SURFACE OF LEFT CREASE BEAM WEB, FR23-24. REPAIR PER SRI.SDR DALA1301361521Failsafe · crackedCRACK INDICATION FOUND ON RT BS 955. REAR SPAR BULKHEAD SIDE FITTING FAIL SAFE STRAP. REPAIRED CARRIED OUT IAW ERA 509691-14AD REV ORG.SDR DALA1301351521Failsafe · crackedCRACK INDICATION FOUND ON LT BS 955, REAR SPAR BULKHEAD SIDE FITTING FAIL SAFE STRAP. REPAIRED CARRIED OUT IAW ERA 509690-14AD, REV ORG.SDR CHQA20130120036Window Frame · damagedDURING INSPECTION, THE RIGHT EMERGENCY EXIT HATCH OUTSIDE FRAME WAS FOUND GAUGES AND SHEET METAL DIVIDERS WERE FOUND TO BE PEELED BACK AND BENT. DAMAGED AREA WAS REPAIRED IAW ETD 2013-145-001467-A.SDR QXEA2013012000095Structure · damagedON APPROACH, AT 200 FT, ACFT HAD A BIRD STRIKE, RECEIVING DAMAGE TO THE NOSE OF THE ACFT AND THE STABILIZERS. LANDING UNEVENTFUL. ACFT FERRIED FOR REPAIRS AND IS CURRENTLY DOWN FOR REPAIRS.SDR ASOA20130120241Web · corrodedACFT IS IN FOR A C-CHECK WHEN CORROSION WAS FOUND AT A SCREW HOLE IN CLOSEOUT WEB AT FRAME 65 AT CARGO DOOR CUTOUT. MX REMOVED CORROSION AND FABRICATED A NEW PART AND INSTALL IAW EC 5320-01479, REV A. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF SDR UHLA2013011900047Support Angle · damagedCOCKPIT WINDSHIELD UPPER CENTER POST SUPPORT ANGLES DAMAGED IN FWD RADIUS EDGE. SUPPORTS REPAIRED IAW ETD 2013-170-001113. MAJOR REPAIR.SDR UALA2013012100341Structure · corrodedINTERNAL TAIL AREA ABOVE CENTER HORIZONTAL STAB, BS 1787 BETWEEN S4-5R APU INLET FWD EDGE METAL ATTACH FLANGE HAS CORROSION AT A NUT PLATE. REMOVED CORROSION ON APU INLET ATTACH FLANGE FOUND TO BE OUT OF LIMITS IAW SRM 53-80-15. REPAIRED APU INLET. MAJOR RSDR R61A201301190067Retainer · gougedWHILE AIRCRAFT WAS IN HEAVY CHECK, MAINTENACE FOUND L1 DOOR AFT SEAL REST GOUGED. MAINTENANCE REMOVED AND REPLACED L1 DOOR AFT SEAL REST IAW SRM 51-40-02, 51-41-01, AND 51-43-01. MAJOR REPAIR.SDR R61A2013011900Seal Seat · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE L1 DOOR AFT SEAL REST GOUGED. MAINTENANCE REMOVED AND REPLACED THE L1 DOOR AFT SEAL REST IAW EMB 175 SRM 51-40-02, 51-41-01, AND 51-43-01. "MAJOR REPAIR" THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR ASOA20130119043Beam · corrodedDURING C-CHECK BAGGAGE DOOR CUT OUT LOWER BEAM CORRODED. MX PERFORMED INSTALLATION OF LWR BEAM CUT OUT ON BAGGAGE DOOR IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASAA2013011893762Fitting · corrodedAFT PIT/AFT DOOR STOP FITTING NR 5 HAS CORROSION AROUND STOP PAD. ACFT GROUNDED. LOCATED AND DRILLED NEW STOP FITTING IAW SRM 51-40-05.SDR ASAA2013011893761Fitting · corrodedAFT CARGO BAY FWD DOOR STOP NR 1 HAS CORROSION AROUND STOP PAD. NEW STOP FITTING, LOCATED, DRILLED AND TOPCOATED IAW SRM 51-40-05 AND MM 51-21-41-377-0320.SDR ASAA2013011893760Fitting · corrodedAFT CARGO FWD DOOR STOP NR 2 HAS CORROSION AROUND STOP PAD. LOCATED AND DRILLED NEW STOP FITTING IAW SRM 51-40-05.SDR ASAA2013011893759Fitting · corrodedAFT CARGO BAY AFT DOOR STOP FITTING NR 4 CORROSION AROUND STOP PAD. NEW STOP FITTING LOCATED, DRILLED AND TOPCOATED IAW SRM 51-40-05 AND MM 51-21-41-377-032.SDR ASOA20130118028Door Frame · corrodedDURING C-CHECK, MAIN DOOR LOWER FRAME HAS CORRODED SCREW HOLES. MX PERFORMED REPAIR ON MAIN DOOR LOWER FRAME SCREW HOLES IAW EC5210-01154, REV A. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR UALA2013011800316Pan · dentedAFT LAVATORY SERVICE PANEL PAN IS DENTED AT SERVICE CONNECTION AREA. HFEC INSPECTION ACCOMPLISHED PER NTM PART 6 51-00-21, NO DEFECTS NOTED. REPLACED PAN WITH NEW PER ECRA 5300-01457 AND DRAWING 146N3650. COMPLETED INSTALLATION REF DRAWING 146N3650.SDR SWAA2013012411771Crease Beam · corrodedSERVICE DOOR CORRODED ON CREASE BEAM AT STA 305. REMOVED AND REPLACED BEAM IAW SRM AND BOEING DWG.SDR ASOA2013020602964Beam · corrodedCORROSION FOUND ON END OF TRANSVERSE BEAM AT FS 349 RT SIDE. REPAIRED IAW REO 601R-53-21-2401.SDR DALA13002346307Failsafe · crackedDURING OPEN HOLE HFEC INSPECTION ON LT SIDE BS 1120 TENSION TIE, FOUND ONE CRACK AT FAILSAFE, UPPER ROW 1ST FASTENER HOLE FROM OTBD. FRAME SEGMENT REPAIR CARRIED OUT IAW SRM 53-40- 07, FIG 201, REPAIR 4. FAILSAFE REPAIR CARRIED OUT IAW SRM 51-70-11, FIG 1.SDR UHLA2013011500040Door Frame · damagedFWD PAX DOOR FRAME CUTOUT ABOVE DOOR HAS DAMAGE FROM CONTACT WITH DOOR LINING UPPER MOUNT BRACKET. L1 DOOR/PAX CUTOUT UPPER BEAM BETWEEN FRAMES 17L AND 19L REPAIRED IAW ETD 2013-170-000980. MAJOR REPAIRSDR DALA13005270941Door Frame · corrodedCORROSION ON AFT CARGO BAY LOWER DOOR FRAME BEAM. SPACER REPAIR DOUBLER WAS REPLACED IAW SRM 53-05, FIG 123.SDR ASOA20130113230Door Frame · corrodedFORWARD LOWER CORNER SERVICE DOOR CUT-OUT CORRODED BEYOND LIMITS AFTER BLEND-OUT. R & R SERVICE DOOR FRAME.SDR ASAA2013011293811Beam · corrodedCORROSION ON TRANSVERSE BEAM 344 LBL 10-BL0. ACFT GROUNDED. REPAIRED BS 344 .LBL 44-RBL 28 IAW SRM 53-10-51, REPAIR 10 AND SRM 53-10-51, REPAIR 9.SDR AALA20130112005Door Frame · crackedFORWARD SERVICE DOOR SURROUND SUBFRAME CRACKED IN FRONT CORNER AT FLOOR LEVEL STATION 294.5. INSTALLED REPAIR ANGLE AND SHIMS PER SRM 51-70-11-2R.SDR EE4Y2013021200006Window Frame · crackedUPPER FUSELAGE FLIGHT CONTROL COMPARTMENT AT BS 219.75, RBL 33 NR 1 WINDOW FRAME ASSY WITH CRACK. THE NR 1 WINDOW FRAME WAS RELPACED IAW SB 737-53-1316, COO-AMX-13-0003-02 (R1), UNDER THE NON ROUTINE WO A1B038, SUB JOB: 2, ITEM: 92.SDR IPXA3M76766Fitting · crackedINSPECTION TYPE: 4C, FITTING CRACKED ON CENTER, LOWER AUXILARY TANK AT 3:00 POS RT SIDE 4TH FRAME FROM REAR. FABRICATED AND REPLACED FITTING IAW SRM 51-33-01 PG 45, PARA 9 AND PG 30, PARA 8.SDR SIMA20130109035Splice · corrodedLONGITUDINAL SPLICE PLATE BETWEEN FRAMES 13/14 AND STRINGERS 17R/18R IS CORRODED. EVALUATED AND FOUND TO BE IN LIMITS IAW EO EM-53MR-2074, STEP D.SDR SWAA2013020112242Window Frame · crackedRIGHT NR 1 WINDOW FRAME CORNER (UPPER OUTBOARD) IS CRACKED. REMOVED AND REPLACED FIRST OFFICERS NR 1 RIGHT WINDOW FRAME. ACCOMPLISHED ON ACO 8339-53.SDR ASOA2013012902915Bracket · corrodedSERVICE DOOR CUTOUT TEE BRACKET IS SEVERELY CORRODED AT FS 319.70, WL 70.60. REMOVED FITTING IAW SRM 51-42-21 FOR REPLACEMENT. LOCATED & DRILLED NEW SERVICEABLE SERVICE DOOR FITTING IAW SRM 51-40-11 & INSTALLED NEW SERVICEABLE FITTING IAW SRM 51-42-21.SDR ASOA2013012902909Fitting · crackedCO-PILOTS WINDSHIELD SIDE POST LOWER AFT, OTBD FITTING IS CRACKED. REMOVED CRACKED LOWER AFT OTBD FITTING FROM CO-PILOTS WINDSHIELD SIDE POST IAW SRM 51-42-21. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE LOWER AFT OTBD FITTING, ON CP-PILOTS WINDSHIELD SIDSDR ASOA2013012902908Fitting · crackedPILOTS WINDSHIELD SIDE POST LOWER AFT OTBD FITTING IS CRACKED. REMOVED CRACKED LOWER AFT OTBD FITTING FROM PILOTS WINDSHIELD SIDE POST IAW SRM CH 51-42-21. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE LOWER AFT OTBD FITTING, PN 601R33235-3S ON PILOTS WINDSSDR UALA2013010900160Crease Beam · corrodedBS 1681.8 CREASE BEAM HAS UPPER SURFACE CORROSION AROUND FASTENER HOLE. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION FROM PASSENGER CABIN CREASE BEAM UPPER SURFACE STA 1681.8 -14 RBL 56. REPAIRED CREASE BEAM.SDR UALA2013010900167Crease Beam · corrodedPASSENGER COMPARTMENT BS 1681.8 -14 CREASE BEAM AT RBL 56 HAS UPPER SURFACE CORROSION AROUND FASTENER HOLE. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION FROM PASSENGER CABIN CREASE BEAM UPPER SURFACE STA 1681.8 -14 RBL 56. REPAIRED CREASE BEAM IAW EA 121412SDR LR7A2013010800432Ring Assembly · crackedDURING SCHEDULED B-2 CHECK, FOUND RT AFT FUSELAGE INTERIOR FS 957 RING SEGMENT HAD 2.5" LONG CRACK AT WL 260, RBL 66. REPAIR ACCOMPLISHED IAW SMP583 FIG 53-50-07.SDR LR7A2013010800430Former · crackedDURING SCHEDULED B-2, , LT AFT FUSELAGE INTERIOR FORMER AT FS 834, LBL 66, WL 180 FOUND CRACKED. REPAIRED IAW SMP583 FIG 53-50-10.SDR ASOA20130108210Beam · corrodedACFT IN FOR A C-CHECK, CHECK WHEN THE CARGO DOOR CUTOUT WAS FOUND. CORRODED ON THE THRESHOLD BETWEEN FRAMES 65 AND 68. MX BLENDED THE CORROSION IAW SRM 51-10-03. R & R THE AREAS OUT OF LIMITS WITH FABRICATED PARTS IAW SRM 51-40-02. ALL WORK WAS ACCOMPLISHED ASDR FDEA201301080052Skin · misrepairedEXTERNAL SKIN MISREPAIRED BS 535.5 BETWEEN S22 AND 23R ACCOMPLISHED EA F-5330-165118. CAT "B" MAJOR REPAIR.SDR UALA2013010900163Crease Beam · corrodedCREASE BEAM INBOARD ANGLE IS CORRODED BS 688-732. REMOVED CORROSION FROM CREASE BEAM IAW SRM 53-30-13 ORG. OUT OF LIMITS IAW SRM 53-30-13. REMOVED & REPLACED BEAM IAW SRM 51-40-02. MAJOR REPAIR.SDR SWAA2013011411409Door Frame · crackedFWD SERVICE DOOR FWD FRAME STA 294.5 HAS 1.5 IN CRACK AT LOWER CORNER. REPAIRED FRAME PER EA.SDR SWAA2013011411390Crease Beam · corrodedCORROSION I/N CREASE BEAM WEB CHORD RBL 55 AT C-1 STA 294-334. REMOVED AND REPLACED CHORD IAW SRM.SDR ASOA20130106004VBeam · corrodedDURING C-CHECK BAGGAGE DOOR CUTOUT CENTER SILL CORRODED. MX R & R BAGGAGE DOOR CUT OUT CENTER SILL LOWER BEAM FOR CARGO DOOR IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR FDEA201301050026Crease Beam · crackedRT CREASE BEAM BS 598, HAS CRACKED AND CORRODED FASTENER HOLE VIEWED UNDERSIDE. REMOVED CORROSION IAW-SRM-53-30-13, FOUND TO BE OUT OF LIMITS IAW SRM-53-30-13, FIG 101, DETAIL V. R & R WEB IAW SRM-51-40-02, AND DWG NR 143N5520, CAT."A" MAJOR REPAIR.SDR DALA1302760684Crease Beam · corrodedCREASE BEAM CORRODED IN MAIN CABIN STA 960-984 RBL 20.5. REPLACED CREASE BEAM IAW SRM 51-40-02, PG 4 AND 39.SDR SWAA2013020112223Crease Beam · crackedCRACK (2EA) ON S-17L BETWEEN BS 440+5" TO BS 440+9" FWD PAX CABIN. REPAIRED CREASE BEAM ON STR 17L OUTER CHORD REPAIR BETWEEN BS 439 AND BS 455 FWD PAX CABIN IAW EO AEM -HC53-003/13 R0 AND EA 1-353-21562 R0.SDR FDEA201301040018Crease Beam · damagedRIGHT INBD CREASE BEAM AT BS450-665 HAS NICKS, SCRATCHES AND CORROSION. REMOVED DAMAGE ON INBD CREASE BEAM AT BS 450 - 665, ORIGINAL MATERIAL .070, .056. REMAINING REWORK, FOUND TO BE OUT OF LIMITS IAW SRM 53-30-13, DETAIL VIII. R & R CREASE BEAM IAW SRM SDR R5KB2013031150569Door Frame · damagedOTBD STRUCTURE AT DOOR FRAME, BS 950E DAMAGED AT STR 27R.SDR DALA1303610684Failsafe · corrodedMAIN CABIN LT SIDE STA 1540 AT STR 14L FRAME HAS SURFACE CORROSION. ACCOMPLISHED ERA 508331-14, REV A.SDR FDEA201301020007Crease Beam · corrodedRT INDB CHORD CREASE BEAM AT STA 1405-1630 HAS SCRATCHES AND AREAS W/ CORROSION, TOP & UNDERSIDE, AROUND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 53-60-13, DETAIL II, FIG 101. FABRICATED NEW CREASE BEAM IAW DWG 146N559
Back to JASC 5310