What was found
RT INDB CHORD CREASE BEAM AT STA 1405-1630 HAS SCRATCHES AND AREAS W/ CORROSION, TOP & UNDERSIDE, AROUND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 53-60-13, DETAIL II, FIG 101. FABRICATED NEW CREASE BEAM IAW DWG 146N5590. INSTALLED CREASE BEAM IAW SRM 51-40-02 AND DWG 146N5590, STA 1405-1630 RT. MAJOR REPAIR.