JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201109053705Skin · damagedL1 DOOR SKIN CUTOUT, AFT SKIN EDGE HAS MINOR MECHNICAL DAMAGE. DAMAGE OUT OF SRM LIMITS. BLENDED DAMAGE. MAX DEPTH 0.004" X 0.5" LENGTH. INSP IAW NTM 51-10-08, NO DAMAGE. MINOR REPAIR.SDR FDEA201109053704Failsafe · chafedR1 DOOR SKIN CUTOUT FAIL SAFE RING UPPER FWD CORNER REWORK IS OUT OF SRM LIMITS. BLENDED, ASSESSED AND INSP IAW SRM 53-73-10, NTM 51-10-04, 51-10-08, 51-90-00, & 51-10-01. FASTENER REMOVED , INSPECTED AND 1ST OVERSIZE FASTENER REPLACED IAW EA 6-5300-15431SDR QXEA2011090700795Beam · crackedACFT DOWN FOR C-CHECK. FWD BAGGAGE COMPARTMENT BEAM STOP NR 2 FOUND CRACKED. REMOVED BAG DOOR AND REPAIRED CRACK IAW RD 8/4-52-679.SDR FDEA201109033643Beam · corrodedBS 1183, RBL 17.8 VERTICAL BEAM IS CORRODED WITH EXFOLIATION AT LOWER ATTACHMENTS. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW EA 7-5310-152433SDR USAA2011090700022Door Frame · crackedQ5 CHECK - CRACK IN FORWARD LEFT ENTRANCE DOOR FORWARD CUTOUT FRAME WEB AT BS 303.9, S16L. REPLACED FORWARD CUTOUT FRAME WEB AT BS 303.9, S16L IAW EO 5311-01025.SDR DALA1151173712Crease Beam · corrodedFWD CABIN RT CREASE BEAM CORRODED FROM FS 294-360 UPPER SURFACE. REPLACED CREASE BEAM.SDR FDEA201109013623Floor Support · failedFLOOR SUPPORT MISREPAIRED. REPAIRED IAW SRM 51-72-10, PG 1TO3.SDR IPXA11M69267Door Frame · crackedINSPECTION TYPE:4C, L3 DOOR JAMB IS CRACKED AT FWD LOWER LIGHTNING HOLE. STOP DRILLED CRACK ON L3 DOOR JAMB LOWER FWD LIGHTNING HOLE. FABRICATED REPAIR DOUBLER AND INSTALLED REF SRM 53-40-15, REPAIR 3, FIG 2 01, REV 47.SDR SWAA116265Crease Beam · corrodedDURING SCHEDULED 22Y CHECK, FOUND LT CREASE BEAM WEB CORRODED BETWEEN BS 420 TO BS 440. REMOVED AND REPLACED WEB IAW SRM.SDR SWAA116244Crease Beam · crackedDURING SCHEDULED 26Y CHECK, FOUND CREASE BEAM INNER CHORD CRACKED AT BS 639, STR 17L. REPAIRED CHORD IAW EO.SDR SWAA116233Crease Beam · corrodedDURING SCHEDULED 12Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 72E+5, STR 17R. REPAIRED WEB IAW SRM AND DWG.SDR SWAA116232Crease Beam · corrodedDURING SCHEDULED 12Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 807, STR 17L. REPAIRED WEB IAW SRM AND DWG.SDR FDEA201108313598Crease Beam · gougedCREASEBEAM AT BS 1290-1370 HAS NUMEROUSE GOUGES AND SCRATCHES. FUTHER INVESTIGATION FOUND A PUNCTURE HOLE WAS FOUND, IAW SRM 53-60-15, FIG 101, DETAIL IV. NOTE C, PUNTURE HOLES ARE NOT PERMITED ADJACENT TO FASTENER HOLES LESS THAN 1" AWAY, R & R DAMAGESDR DALA1154779013Door Frame · damagedHIDDEN DAMAGE ELONGATED HOLES WERE FOUND AFTER REMOVED FITTINGS ON MID CARGO DOOR JAMB LOWER BEAM. DAMAGE REMOVED IAW DC9/MD80 SRM 53-05 FIG 123. REPAIR ACCOMPLISHED IAW DC9/MD80 SRM 51-30-2, 51-30-5 FIG 123.SDR ZZDA20110830001Door Frame · corrodedFORWARD CARGO DOOR FRAME CORRODED. ACCOMPLISHED DOOR FRAME SPLICE REPAIR PER SRM 53-20-15.SDR USAA2011090700009Door Frame · corrodedQ5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON AFT FRAME AT AFT CARGO DOOR CUTOUT AT BS 847, RBL 22. REPLACED AFT FRAME AT AFT CARGO DOOR CUTOUT AT BS 847, RBL 22 IAW B737-400 SRM 51-10-02.SDR CHQA201100363Stop Fitting · corrodedDURING INSPECTION, THE DOOR STOPS ON THE SERVICE DOOR STRUCTURE NEEDED TO BE BLENDED. MAINTENANCE BLENDED THE SERVICE DOOR STOPS IN ACCORDANCE WITH SRM 53-21-15. A HIGH FREQUENCY EDDY CURRENT INSPECTION WAS CARRIED OUT ON THE DOOR STOP FITTINGS IN ACCORDANCESDR CHQA201100362Stop Fitting · corrodedDURING INSPECTION, THE MAIN DOOR STOP NEEDED TO BE BLENDED. MAINTENANCE BLENDED THE MAIN DOOR STOP IN ACCORDANCE WITH SRM 53-21-15. A HIGH FREQUENCY EDDY CURRENT INSPECTION WAS CARRIED OUT ON THE DOOR STOP FITTINGS IN ACCORDANCE WITH NDI MANUAL, INTRODUCTIONSDR UALA2011083004661Crease Beam · corrodedCORROSION ON RT CREASE BEAM STA 324. MAJOR REPAIR ACCOMPLISHED. REPAIRED STA 324 CREASE BEAM PER THE INSTRUCTIONS ON PD 57-53-174 AND EVA 81240 WITHOUT DEVIATION.SDR CHQA201100356Door Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE SERVICE DOOR FORWARD BOTTOM FRAME AND THE AFT FRAME. PERFORMED A HIGH FREQUENCY EDDY CURRENT INSPECTION WITH NO CRACKS FOUND. SURFACE CORROSION AROUND ANCHOR NUT PLATE ON BOTTOM SERVICE DOOR FRAME BLENDED IN ACCOSDR CHQA201100361Door Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR SURROUND STRUCTURE LOWER BEAM. MAINTENANCE REPLACED THE CARGO DOOR SURROUND STRUCTURE LOWER BEAN. THE NEW PART WAS INSTALLED WITH A SOLID RIVET IN ACCORDANCE WITH SRM 51-40-02.SDR SWAA116167Crease Beam · corrodedDURING SCHEDULED SPV CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 500A, RBL 66. REMOVED AND REPLACED WEB IAW SRM AND DWG.SDR EE4Y1108003Beam · crackedUPPER FUSELAGE BS 578, RBL 65 STUB BEAM UPPER CHORD CRACKED. THE PART CRACKED WAS REPLACED.SDR AALA20110827TUL01Door Frame · gougedFWD ENTRY DOOR: DOOR JAMB HAS DAMAGE ON AFT FACE OF DOOR JAMB INTERNAL STATION 199 WATERLINE 72. DOUBLER INSTALLED AFT FACE OF DOOR JAMB STATION 199 WATERLINE 72 PER EA MD80-53-018868.SDR UALA2011082904590Crease Beam · corrodedCREASE BEAM RT SIDE AT STA 755-760 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION. FABRICATED REPAIR PARTS. INSTALLED REPAIR AT STA 755-760, RT SIDE.SDR DALA1155219013Door Frame · corrodedCORROSION ON LOWER BEAM OF AFT CARGO COMPARTMENT DOOR JAMB FROM STA Y=1171 TO Y=1212. REPAIR ANGLE AND BUSHINGS INSTALLED IAW DC9/MD80 SRM 53-05 FIG 123 AND ERA 495239-14 REV ORIG.SDR FDEA201108253474Doubler · crackedCENTER WHEEL WELL RT SIDE FWD SPOILER MIXER CONTROL ROD CUT-OUT DOUBLER FOUND CRACKED. DOUBLER REMOVED IAW SRM 51-31-01, REV 47. NEW DOUBLER FABRICATED IAW DWG AEA0526 AND INSTALLED IAW SRM 51-33-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 1SDR FDEA201108253473Doubler · crackedCENTER WHEEL WELL, LT SIDE FWD SPOILER MIXER CONTROL ROD CUT-OUT DOUBLER FOUND CRACKED. REMOVED DOUBLER IAW SRM 51-31-01, REV 47. NEW DOUBLER FABRICATED IAW DWG AEA0526 AND INSTALLED IAW SRM 51-33-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100,SDR FDEA201108243446Torque Box · crackedAFT AIRSTAIRS, LT LOWER TORQUE BOX, INBD WEB, UPPER ROW OF RIVETS HAVE CRACK AT BS 1233. CUT OUT DAMAGED AREA IAW SRM 51-10-1 REV 103. FABRICATED FILLER AND DOUBLER IAW SRM 53-10-2 FIG 6 AND 51-40-2 FIG 1. INSTALLED FILLER AND DOUBLER IAW SRM 51-40-2 FIG 1.SDR FDEA20110823341AWindow Frame · corrodedCOCKPIT- L2 SLIDING WINDOW CUT-OUT AT LOWER AFT FRAME SUPPORT FOUND CORRODED FOUND CORROSION EXCEEDED SRM LIMITS. COMPLIED WITH EA 1-5320-149869. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 113.SDR CA110822008Door Frame · cracked(CAN) DURING A MAJOR AIRFRAME INSPECTION, THE UPPER FORWARD AIRFRAME ASSY THAT RECEIVES THE LATCH FROM THE FWD UPPER AIRSTAIR DOOR WAS FOUND TO BE CRACKED. IT IS BELIEVED THE PART MAY BE ORIGINAL. (13000 HOURS). THE DEFECT IS VISIBLE FROM OUTSIDE THE ACFT.SDR ASOA201101561Crossbeam · corrodedLT FS280 CROSSBEAM CORRODED. CORROSION DAMAGE EXCEEDS ALLOWABLE LIMITS IAW SRM CH 53-00-00-101-001. REMOVED CROSSBEAM IAW SRM CH 51-42-06-001-001, 51-42-13-001-001, 51-42-21-001-001, 51-42-22-001-001. INSTALLED NEW CROSSBEAM IAW SRM 51-42-06, SRM 51-42-13SDR ASOA201101558Beam · crackedFS 280 TRANSVERSE BEAM CRACKED IN WEB OTBD OF RBL 9. THIS DISCREPANCY AND THE AFT J-ANGLES ON JOB 8784121, OP 159 IS BEING REPAIRED AS ONE IAW REO 601R-53-11-926.SDR C2XA11TY133Door Frame · corrodedTYS - A/C IN FOR A C-CHECK WHEN INSPECTION FOUND THE LOWER AFT CORNER OF THE SERVICE DOOR CUTOUT CORRODED. MAINTENANCE REPAIRED THE LOWER AFT CORNER OF THE SERVICE DOOR CUTOUT BY USING A PIECE OF FRAME 22 MATERIAL. ALL WORK WAS ACCOMPLISHED IAW EC5310-01562.SDR JR2R2011082100335Striker · corrodedSVC DOOR LWR SEAL STRICKER CORRODED. REMOVED AND REPLACED SVC DOOR LWR SEAL STRICKER IAW CRJ900 SRM 51-42-06, 51-42-13.SDR FDEA201108193374Failsafe · crackedBS 580 FRAME FAIL SAFE HAS CRACK INDICATION. REMOVED DOUBLER AND ANGLE IAW SRM 51-30-2, FABRICATED DOUBLER AND ANGLE IAW DWG 65-15932, INSTALLED DOUBLER AND ANGLE IAW SRM 51-30-2SDR IPXA11568892Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 396 TO 404 RBL 48. REMOVER CORROSION WITHIN ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR IPXA11568891Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 365.25 TO 418 LBL 27 TO LBL 43. REMOVER CORROSION WITHIN ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR IPXA11568890Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 341 TO 365.25 LBL 48 TO LBL 59. REMOVED CORROSION WITHIN ALLOWABLE LIMITS EO B757-5310-38276-D.SDR IPXA11568889Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 362 TO 377 LBL 22. REMOVED CORROSION WITHIN ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR IPXA11568888Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 365.25 TO 395 LBL 49 TO LBL 55. REMOVER CORROSION WITHIN ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR IPXA11568887Shear Web · corrodedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 418 TO 440 LBL 49 TO LBL 57. REMOVED CORROSION WITHIN ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR IPXA11568886Shear Web · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR SHEAR WEB ON UPPER SURFACE HAS CORROSION AROUND FASTENER HOLES FROM BS 405 TO 418 RBL 25 TO RBL 38. REMOVER CORROSION WITH ALLOWABLE LIMITS OF EO B757-5310-38276-D.SDR EIAA2011166Doubler · crackedHFEC INSPECTION FOUND CRACK ON WEB DOUBLER ON L1 DOOR CUTOUT FRAME ST STA 488 FWD SIDE OF DOUBLER AT LWR EDGE OF DOOR STOP NR 1. DAMAGED FRAME REMOVED. NEW WEB DOUBLER FABRICATED PER DRAWING 65B01838-11 AND INSTALLED PER B747SRM 51-30-02.SDR SWAA115904Crease Beam · corrodedDURING SCHEDULED 12Y CHECK, FOUND RT CREASE BEAM WEB CORRODED BETWEEN BS 709 TO BS 720. REMOVED AND REPLACED WEB PER SRM.SDR SWAA115862Crease Beam · corrodedDURING SCHEDULED 22Y CHECK, FOUND CREASE BEAM INNER CHORD CORRODED BETWEEN BS 954 TO BS 986, RBL 50. REMOVED AND REPLACED CHORD PER SRM AND DWG.SDR FDEA201108133266Structure · misrepairedLOCK FASTENERS WITH NO SPACING ON FWD SIDE OF STA 1183, LBL 12.0, WL 190. ACCOMPLISHED REPAIR IAW EA 7-5310-150074.SDR ASOA201101510Structure · corrodedFOUND CORROSION AT FS 661.00 AND STR 27. REPAIRED IAW SRM 51-21-06-001-001-A01.SDR USAA2011081500008Door Frame · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON L2 DOOR SHAPE BETWEEN FR66 TO FR68, Y1589. REPLACED L2 DOOR SHAPE BETWEEN FR66 TO FR68, Y1589 IAW AIRBUS DRAWING D53480505.SDR CHQA201100347Stop Fitting · damagedDURING INSPECTION, THE PASSENGER DOOR STOP WAS FOUND TO BE DAMAGED. MAINTENANCE BLENDED THE PASSENGER DOOR STOPS IN ACCORDANCE WITH SRM 53-21-15. A HIGH FREQUENCY EDDY CURRENT INSPECTION WAS PERFORMED IN ACCORDANCE WITH NDI MANUAL, INTRODUCTION PAGE 17E, WIT
Back to JASC 5310