SDR USAA060796Plate · corrodedRIGHT TRANSITION ANGLE BETWEEN STA 500B AND 500C REMOVED SURFACE CORROSION IAW SRM 53-30-53 LEVEL 1 C53-208-01 DEFECT SIZE: .50"SDR USAA060792Plate · corrodedRIGHT TRANSITION ANGLE IN CARGO BIN BETWEEN STA 500A ABD 500B REMOVED SURFACE CORROSION, IAW SRM 53-30-53 LEVEL 1 C53-208-01 DEFECT SIZE: .50"SDR 06FDEA2239Doubler · corrodedACCESS DOOR CUTOUT DOUBLER DOOR 134AR BETWEEN FR 23 & 24 O/B RIGHT SIDE HAS CORROSION. REMOVED AND REPLACED DOUBLER IAW A310-200 SRM 51-74-10, 51-72-10 AND 51-40-21.SDR DU4R2006507Crease Beam · corrodedS/O 291018 NR 23878 CORROSION ON CABIN CREASE BEAM BS 660 TO 760 LT. REMOVED AND REPLACED L/H BS 660 - 760 CABIN CREASE BEAM P/N 143N8328U53 IAW B757 SRM 51-40-02.SDR QXEA200601478Structure · corrodedPDX: CORROSION FOUND UNDER NUTPLATE AT LT OUTBOARD NUTPLATE STA X782. MAINTENANCE REPAIRED IAW Q400 NDTM PART 6, 51-00-01, NDTM PART 1, 51-00-04, RD 8/4-53-1558 AND HORIZON EA 6-53-741.SDR COMA0670149Beam · corrodedFS 280 TRANSVERSE BEAM CORRODED BEYOND REPAIRABLE LIMITS. REPLACED THE TRANSVERSE BEAM AT FS 280 IAW BOMBARDIER REO 670-53-11-047, REV D.SDR USAA060754Door Frame · crackedFWD SERVICE DOOR CUTOUT FWD FRAME REVEAL AT UPPER DOOR STOP FITTING O/B LOWER CRACKED. REPLACED WITH IDENTICAL PART IAW SRM 51-10-02. DEFECT SIZE: .50 INCH.SDR USAA060752Crease Beam · corrodedCREASE BEAM WEB AT STRINGER 17R FROM STA 616 TO STA 639 CORRODED. INSTALLED WEB PER BOEING DWG 65-47973 LEVEL 1 C53-107-01. DEFECT SIZE: 2 INCHES.SDR USAA060751Web · corrodedAFT CARGO DOOR CUTOUT CORRODED. PART REPLACED WITH IDENTICAL PART IAW SRM 51-00-02 LEVEL 1 C53-100-01. DEFECT SIZE: 2 X 2 INCHES.SDR A6WA200640227Windshield · crackedCRACKED RIGHT WINDSHIELD, HAPPENED DURING TAXI OUT. REMOVED AND REPLACED WINDSHIELD, OPS CHECK GOOD IAW AMM 56-11-01. (M)SDR AT0700084Vent · crackedCRACK ON VENT BOX RIGHT HAND SECTION AFT CORNER. INSTALLED REPAIR OF AFT FUSELAGE RIGHT SIDE VENT BOX DRAIN PAN IAW T/C 17-5320-2023 FIG 1.SDR SIMA200615902Structure · vibrationDFW - FLT 3200 - NOTIFIED BY MAINTENANCE VIA GRD LINE. VIBRATION, SIMILAR TO LIGHT TURBULENCE, AT SPEEDS 235 KTS TO 250 KTS, POWER SETTING SEEMS IRRELEVANT. (M)SDR 2006UALA01069Door Frame · crackedFWD CARGO DOOR CUTOUT FWD FRAME WL 160 S-24R DOOR STOP HAS A CRACK VISIBLE FROM FWD SIDE OF FRAME.SDR TRAX200600322Structure · corrodedCORROSION AROUND CAMLOCK RECPTACLES IN FLT COMPT FS 260 JUST AFT AND BELOW CENTER PEDESTAL. BLENDED CORROSION FOUND IN FLT COMP FS 260 BELOW CENTER PEDESTAL. FOUND WITHIN LIMITS NEEDS ALODINE PRIME AND PAINT. CORROSION BLENDED IAW CRJ 200 SRM 51-21-06 DK 702SDR TRAX200600325Structure · corrodedCORROSION FOUND BETWEEN AT FS409+128 TO FS 559.00 AND LBL36 AND TO FLOOR STR.17L ( FLOOR WEATHER STRIPPING IS REQUIRED TO BE REMOVED AND CLEANED AREA TO INSPECT FURTHER POSSIBLE CORRODED AREAS)SDR TRAX200600321Structure · corrodedCORROSION AROUND CAMLOCK RECEPTACLES AT FS 280 BETWEEN LBL 9 AND RBL 9 (MARKED). DRILLED OUT FASTENERS AND REMOVED CORRODED ANGE AT FS280,PICKED UP EXISTING FASTENER HOLES IN NEW ANGLE, ALODINED AND INSTALLED ANGEL WET WITH SEALANT AND SOLID RIVETS PER THE CRSDR ALGR109780Beam · crackedFOUND BOX BEAM ASSY CRACKED. REPLACED W/NEW PART.SDR ALGR109771Fuel Cell · separatedFOUND FUEL CELL PANEL ASSY SEPARATED. REPLACED W/NEW OR RECONDITIONED PART.SDR QXEA200601421Window Frame · tool damagePDX - C4 TOOLING MARKS IN THREE AREAS IN CO-PILOTS WINDSHIELD FRAME RADIUS, APPROXIMATELY 5, 7 AND 10 INCHES OUTBOARD OF CENTER POST. REPAIRED IAW DHC-8-200 SRM 51-40-11, HORIZON AIR EA 2-53-698, AND RD 8-53-9089.SDR SWAA061896Door Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND RT OVERWING EMERGENCY EXIT DOOR FRAME CUTOUT CRACKED AT BS 620, RBL 64, BOTTOM FASTENER. REPAIRED FRAME SECTION PER TYPICAL REPAIR MANUAL.SDR SWAA061895Door Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND LT OVERWING EMERGENCY EXIT DOOR FRAME CUTOUT CRACKED AT BS 620, LBL 64, BOTTOM FASTENER. REPAIRED FRAME SECTION PER TYPICAL REPAIR MANUAL.SDR QXEA200601422Window Frame · damagedPDX - C4 CO-PILOTS WINDSHIELD FRAME, UPPER INBOARD CORNER NUT PLATE HAS RIVET SET DAMAGE BELOW UPPER RIVET HOLE. REPAIRED IAW HORIZON AIR EA 2-53-698 AND RD 8-53-9089.SDR TRAX200600302Angle · crackedRT O/B 484 IS CRACKED. CUT AWAY DAMAGED FLANGE. MADE A NEW ANGLE. NDT CUTLINE ON W/C 237. FABRICATED ANGLES FLUORESCENT INSPECTION PERFORMED. NO CRACKS IAW CRJ NDTM 51-20-08. INSTALLED ANGLE IAW REO 601R-53-41-059. (CLOSED)SDR ASAA0640658Shear Tie · corrodedFOUND CORROSION ON SHEAR TIE. REPLACED FRAME PER SRM 51 40 02.SDR SWAA061875Crease Beam · crackedDURING SCHEDULED 1/2D CHECK, FOUND CREASE BEAM WEB CRACKED AT BS 620, RBL 64. REPAIRED WEB PER SWA EA AND SRM.SDR AT0700082Door Frame · corrodedFWD CARGO COMPARTMENT, LOWER JAMB, SURFACE CORROSION. INSTALLED NEW LOWER FWD JAMB SECTION ON FWD CARGO DOOR CUTOUT AREA IAW B717 SRM 53-20-15 FIG 201. MATERIAL USED .040" 2024.0, HEAT TREATED TO T-3 PER GPS 98PMS.247PS.01.SDR QXEA200602195Window Frame · damagedPDX: FUSE INTERIOR: LT CABIN WINDOW FRAME AT STA X595 LOWER FWD SCREW BORE HAS A WEAR MARK FROM THE WINDOW SEAL. MAINTENANCE REPAIRED IAW HORIZON EA 6-53-734 AND RD 8/4-53-1543.SDR DHL2006873528Door Frame · crackedAFT PASSENGER DOOR JAMB AFT UPPER CORNER 0.750 INCH CRACK (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW AD2000-20-08, S/B DC8 53-075, DOUGLAS DWG SR08530021, 5750776. REMOVED FASTENERS IAW SRM 51-1-21, SRM 51-1-20D. CUT OUT DAMAGED SECTION AND FABRICATED REPAISDR DU4R2006483Door Frame · corrodedCORROSION R-1 DOOR JAMB LOWER AT FS 198 BELOW AFT CORNER PLATE. FABRICATED AND INSTALLED WEB REPAIR DOUBLER 15 IN X 21.6 IN FROM 7075-T6 .025 IAW DC-9/MD-80 SRM 51-10-3D AND 51-70-4 FIG 4.SDR SIMA200615702Structure · vibrationPILOT WROTE CONSTANT VIBRATION THROUGH THE COCKPIT FLOOR DURING CLIMB AND FLIGHT. PERFORMED ALL TASK ON THE VIBRATIONS W/C AND NO DEFECTS NOTED. PERFORMED FCF AND ALL PARAMETERS WERE OPS CHECK GOOD. TRIAD RELEASED THE A/C AND RETURNED TO SERVICE. (M)SDR 2006UALA01038Door Frame · crackedFWD PIT AFT DOOR OPENING AFT FRAME STA 492.4 CRACKED AT STA 24R.SDR 06FDEA2022Door Frame · damagedFWD CARGO DOOR JAMB AFT LOWER SKIN DOUBLER FOUND DAMAGED. FWD CARGO DOOR JAMB AFT LOWER SKIN DOUBLER REMOVED AND REPLACED AS PER SRM 51-33-01 VOLUME II. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.SDR 2006UALA01032Door Frame · crackedAFT ENTRY DOOR ENTRYWAY FWD LOWER CORNER IS CRACKED.SDR AWXA200600979Stop Fitting · corrodedNR 5910755 - DURING BC-4 CHECK, DISCOVERED LEVEL 2 GALVANIC CORROSION ON STOP FITTING LOCATED AT LOWER SILL SURROUNDING STRUCTURE FR 27+11 INCH, STR 38R, FWD CARGO COMPARTMENT. MAINTENANCE REPLACED STOP FITTING LOCATED ON LOWER SILL SURROUNDING STRUCTURE FR 2SDR AWXA200600978Stop Fitting · corrodedNR 5910746 - DURING BC-4 CHECK, DISCOVERED LEVEL 2 GALVANIC CORROSION ON STOP FITTING LOCATED AT LOWER SILL SURROUNDING STRUCTURE FR 24A+9 INCH, STR 38R, FWD CARGO COMPARTMENT. MAINTENANCE REPLACED STOP FITTING LOCATED AT LOWER SILL SURROUNDING STRUCTURE FR 2SDR AWXA200600977Stop Fitting · corrodedNR 5910747 - DURING BC-4 CHECK, DISCOVERED LEVEL 2 GALVANIC CORROSION ON STOP FITTING LOCATED AT LOWER SILL SURROUNDING STRUCTURE FR 25+1 INCH, STR 38R, FWD CARGO COMPARTMENT IAW SRM A319-51-72-11.SDR AWXA200600975Stop Fitting · corrodedNR 5910754 - DURING BC-4 CHECK, DISCOVERED LEVEL 2 GALVANIC CORROSION ON STOP FITTING LOCATED AT LOWER SILL SURROUNDING STRUCTURE FR 27+8 INCH, STR 38R FWD CARGO COMPARTMENT. MAINTENANCE REPLACED STOP FITTING LOCATED LOWER SILL SURROUNDING STRUCTURE FR 27+8 ISDR VNAA0605013Structure · lightning strikeAFTER LANDING THE CREW REPORTED THE CAPTAIN'S HEADING INFO WAS UNRELIABLE. MAINTENANCE DISCOVERED EVIDENCE OF LIGHTNING STRIKE DAMAGE ON THE LT WINGLET. EN ROUTE AND DETAILED LIGHTNING STRIKE INSPECTIONS WERE PERFORMED. ADDITIONAL LIGHTNING STRIKE DAMAGE WASDR 2006UALA01016Crease Beam · corrodedCABIN FLOOR RT CREASE BEAM IS CORRODED BEYOND REPAIR BS 289-341 RBL 52-61, WL 208.SDR SWAA061789Crease Beam · corrodedDURING SCHEDULED 10Y CHECK, FOUND CREASE BEAM WEB CORRODED AT RT BS 943 TO RT BS 986. REMOVED AND REPLACED CREASE BEAM WEB PER SRM.SDR DHL2006873522Door Frame · crackedD-CARGO DOOR JAMB FWD LWR CORNER 0.500 INCH CRACK STA 1400.000 L-32R (MAJOR REPAIR) AND CORROSION DAMAGE ON LWR FUS SKIN. PERFORMED MAJOR REPAIR IAW SRM 53-4-1 FIG 17A, DWG DACO 5779936. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRMSDR DHL2006873512Door Frame · crackedFWD SVC DOOR JAMB AFT LWR CORNER 0.250" CRACK. PERFORMED MAJOR REPAIR IAW AD2000-20-08, S/B DC8 53-075, DOUGLAS DWG NR`S SR08530021, 5750776. REMOVED FASTENERS IAW SRM 51-1-21, SRM 51-1-20D. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR DOUBLER (AL7075T6 0.SDR TRAX200600256Frame · crackedRT 718 FRAME CRACKED AT STRINGER 12. REPAIRED RT 718 FRAME CRACK AT STRINGER 12 IAW REO 601R-53-61-193. (CLOSED)SDR TRAX200600255Beam · crackedTRANSVERSE BEAM CRACKED JUST O/B OF RBL 9 AT FS 280. CLEANED AREA NEED NDT TO CONFIRM CRACK. PERFORMED ET INSPECTION OF THE FLOOR SUPPORT BEAM BETWEEN AT FS280.00 RBL9 AND 27 IAW CRJ 200 NDT MANUAL PART 1 CHAPTER 51-20-06. BEAM CRACKED AT LOWER RADIUS JUST OSDR UPS06846955Structure · missingPILOT'S SIDE WINDOW BOLT POSITION NR 58 PER MM 56-10-02-2 HAS NO FRAME STRUCTURE BEHIND IT. BOLT ALSO WAS LEFT OUT OF TORQUE SEQUENCE STEP 10 AND 11 DUE TO NO STRUCTURE. DEFERRED CAPTS SIDE WINDSHIELD UPPER OUTBOARD DEFLECTOR AS MISSING PER EO DC8-5610-24395SDR SWAA061782Door Frame · crackedDURING SCHEDULED 1/4D CHECK, FOUND FUSELAGE FRAME AT FWD CARGO DOOR CUTOUT AFT WEB CRACKED AT RADIUS ABOVE LOWER STOP FITTING. REPAIRED FRAME WEB PER SWA EA.SDR SWAA061780Door Frame · crackedDURING SCHEDULED 1/4D CHECK, FOUND FUSELAGE FRAME AT FWD CARGO DOOR CUTOUT FWD WEB CRACKED AT RADIUS BELOW LOWER STOP FITTING. REPAIRED WEB PER SWA EA.SDR SWAA061774Door Frame · crackedDURING SCHEDULED SPV CHECK, FOUND FUSELAGE FRAME AT FWD CARGO DOOR CUTOUT FWD WEB CRACKED, UPPER CORNER NR 5 DOOR STOP. REPAIRED FRAME WEB PER ER.SDR SWAA061772Door Frame · crackedDURING SCHEDULED 10Y CHECK, FOUND FUSELAGE FRAME AT FWD CARGO DOOR CUTOUT FWD WEB CRACKED, LOWER CORNER NR 5 DOOR STOP. REPAIRED FRAME WEB PER ER.SDR SWAA061773Door Frame · crackedDURING SCHEDULED 10Y CHECK, FOUND FUSELAGE FRAME AT AFT CARGO DOOR CUTOUT AFT WEB CRACKED, LOWER CORNER NR 5 DOOR STOP. REPAIRED FRAME WEB PER ER.
Back to JASC 5310